Page 1 of IDAutomation SC4USB Scanner Programming Manual

Manual · ID Automation

IDAutomation SC4USB Scanner Programming Manual

Manual48 pagesPDF 542 KB

Programming manual for the IDAutomation SC4USB barcode scanner: installation and the setup barcodes for each parameter group.

Download the PDF542 KB

Covers · 1 model

The models it covers

Summary

What is in it

IDAutomation's programming manual for the SC4USB hand-held barcode scanner. After short steps for installing a keyboard wedge or RS-232 scanner, it explains the setup method (scan Enter Group, the setting, then Exit) and gives the programming barcodes for each group: interface, keyboard device and language, delays, terminator, scan mode, preamble and postamble, RS-232 parameters, each symbology, code IDs, wand and magnetic settings and function keys. ASCII and hex tables and scanner pin assignments close the manual.

Its parts

  1. Getting Started
  2. Setup Procedures
  3. Setup Menu
  4. Setup flow Chart
  5. Group 0 : Interface Selection
  6. Group 1 : Device Selection for keyboard interface
  7. Group 2 : Inter-character Delay
  8. Group 3 : Language for Keyboard Interface
  9. Group 4 : Terminator
  10. Group 5 : Scan Mode
  11. Group 6 : Preamble and Postamble
  12. Group 7 : Reserved
  13. Group 8 : RS-232 Parameters
  14. Group 9 : Code 39 / Code 32
  15. Group 10-1: Interleaved 2 of 5

From the manual · read page by page

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

The IDAutomation programming manual for the SC4USB scanner, a book of setup barcodes. It explains how to install a keyboard wedge or RS-232 scanner and how to change interface, keyboard, RS-232, scan mode, symbology and output settings by scanning labels. It ends with hex and ASCII tables and cable pin assignments.

Setup method
Scan Enter Group, then the parameter label, then Exit p. 4
Symbologies
Code 39/Code 32, Interleaved, Industrial/IATA and Matrix 2 of 5, China Postage, Code 128, Code 93, Code 11, MSI-Plessey, ISBN/ISSN, Codabar/NW7, Code 4, EAN-13/JAN-13, UPC-A, EAN-8/JAN-8, UPC-E, UCC EAN-128 p. 2
Interface menu
Keyboard, RS-232, Wand, OCIA, DTMF p. 6
Scan modes
Eight trigger and continuous modes; default Trigger On/Good Read Off p. 14
RS-232 settings
300 to 38400 baud (default 9600); 7 or 8 data bits; none, odd or even parity; none, XON/OFF, Scanner Ready, Data Ready or ACK/NAK handshaking p. 17, 18
Keyboard languages
U.S. (default), England, France, Germany, Italy, Belgium, Sweden/Finland, Spanish, Denmark, Portugal, Swiss, Norway, Canada, Holland, Poland, Latin, Japan p. 10, 11
Keyboard hosts
PC/AT, PS/2 50, 60, 70, 80 (default), PC/XT, PS/2 25, 30, IBM 3196, 3197, 3476, 3477, MAC_SE and others p. 7, 8
Terminators
Keyboard: none, CR, space, tab, ESC, CTRL-C; RS-232 adds CR/LF, LF, STX..ETX, XON..XOFF, EOT p. 12, 13
Preamble and postamble
Up to 10 characters each p. 16
RS-232 pinout
9-pin DSUB female: TX 2, RX 3, GND 5, CTS 7, RTS 8, VCC+5V 9 p. 48
Wand output
Wand emulation in normal, Code 39 or Code 128 format p. 37
Function keys
Function key emulation (off by default) adds F1 to F12 and other keys to scanned data p. 41

What this manual walks you through

  • Installing a keyboard wedge scanner with a Y cable p. 3
  • Installing an RS-232 interface scanner p. 3
  • Changing a setting by scanning setup labels p. 4
  • Adding a preamble or postamble to scanned data p. 4, 16
  • Choosing the keyboard host and language p. 7, 8, 9, 10, 11
  • Setting RS-232 baud rate, parity and handshaking p. 17, 18, 19
  • Enabling barcode types and setting their lengths and check characters p. 20, 21, 22, 23, 24, 25
  • Cable pin assignments for wand, RS-232 and keyboard outputs p. 47, 48

Good to know

  • Scan mode settings work only on CCD or laser type scanners. p. 15
  • Options shown in parentheses are only available on request. p. 26
  • For PC use over RS-232, a cable with a DC power jack is needed for external power. p. 48
  • Only three user-defined barcode lengths can be set per symbology group. p. 22

Questions this manual answers

How do I program the IDAutomation SC4 scanner?

Scan the Enter Group label for the setting group, scan the label for the setting you want, then scan Exit. p. 4

How do I make the scanner send a carriage return after each scan?

Use Group 4, Terminator, and scan CR under the keyboard or RS-232 section. p. 12, 13

What baud rates can the scanner use over RS-232?

300, 600, 1200, 2400, 4800, 9600 (default), 19200 and 38400. p. 17

How do I connect the scanner to a PC keyboard port?

Turn off the computer, unplug the keyboard, connect the Y cable to the computer and keyboard, then turn the computer on. p. 3

The whole text · 5 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 4841-48

The file

Size and text

PublisherIDAutomation.com
Pages48
PDF542 KB
TextText from the PDF itself; pages 1, 44, 45 and 46 are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 48

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 48
Page 2
Page 2of 48
Page 3
Page 3of 48