IDAutomation SC4USB scanner Programming Manual www.idautomation.com

|IDAutomation.com provides barcode fonts, components, label printing software and barcode readers, such as scanners and wands. To obtain support for this product, please visit www.idautomation.com/support/

Q XS)

\Y

Page 2

CONTENTS Getting Started ----------------------------------------------------------- 2 Setup Procedures -------------------------------------------------------- 3 Setup Menu----------------------------------------------------------------4 Setup flow Chart ---------------------------------------------------------4 Group 0 : Interface Selection ----------------------------------------- 5 Group 1 : Device Selection for keyboard interface-----------------6-7 Group 2 : Inter-character Delay -------------------------------------- 8 Group 3 : Language for Keyboard Interface ------------------------9-10 Group 4 : Terminator---------------------------------------------------11-12 Group 5 : Scan Mode -------------------------------------------------- 13-14 Group 6 : Preamble and Postamble ----------------------------------15 Group 7 : Reserved ----------------------------------------------------15 Group 8 : RS-232 Parameters ---------------------------------------- 16-18 Group 9 : Code 39 / Code 32 ----------------------------------------- 19-20 Group 10-1: Interleaved 2 of 5 -----------------------------------------21 Group 10-2: Industrial 2 of 5 / IATA----------------------------------22 Group 10-3: Matrix 2 of 5-----------------------------------------------23 Group 10-4: China Postage--------------------------------------------- 24 Group 11 : Code 128/ Code 93/ Code 11/ MSI-PLESSEY-------- 25-26 Group 12 : ISBN/ISSN------------------------------------------------- 27 Group 13 : Codabar / NW7---------------------------------------------28 Group 14 : Code 4------------------------------------------------------- 29 Group 15-1 : EAN 13 / JAN 13---------------------------------------- 30 Group 15-2 : UPC-A-----------------------------------------------------31 Group 15-3 : EAN-8 / JAN-8-------------------------------------------32 Group 15-4 : UPC-E / UCC EAN-128-------------------------------- 33 Group 16 : General Parameters---------------------------------------- 34 Group 17 : Code ID Settings-------------------------------------------35 Group 18 : Wand Type Parameters----------------------------------- 36 Group 19 : Magnetic Parameters-------------------------------------- 37-39 Group 20 : Function Key Emulation----------------------------------40 Function Code for PC XT/AT-----------------------------------------------41-42 Table-Hex : Hexadecimal----------------------------------------------------43 ASCII Table--------------------------------------------------------------------44 Hexadecimal-Decimal Conversion Table ---------------------------------45 Pin Assignments of Scanners------------------------------------------------46-47

1

Page 3

Getting Started Installing Keyboard Wedge Scanner To install a keyboard wedge scanner, follow the steps listed below: 1) Make sure that the scanner has the correct Y (U)- cable for the system (a PC or terminal) 2) Turn off the power of the system 3) Unplug the keyboard from the system 4) Connect the Y (U)- cable to the system and keyboard 5) Turn on the power of the system 6) If the indicator LED lights up and the buzzer sounds, the scanner is ready for reading Installing a RS-232 Interface Scanner To install a RS-232 interface scanner, the host device should have a RS-232 port to receive data from the scanner, follow the steps listed below: 1) Make sure that the scanner has the right connector for the RS-232 port of the host device 2) Make sure that there is a power supply to the scanner (if necessary) 3) Connect the cable to the RS-232 port of the device 4) If the indicator LED lights up and the buzzer sounds, the scanner is ready for reading

2

Page 4

Setup Procedures 1) Locate a group that contains the parameters to be changed. 2) Scan the “Enter Group #” label. The scanner will sound beeps indicate that setup is in progress 3) Scan the label representing the parameter to be changed 4) Scan the “Exit” to end the group currently selected, the scanner will sound beeps. 5) Repeat the procedure for other groups including the parameters to be changed

Example 1: Set the operating mode to “Continuous mode” 1) Scan “Enter Group 5” 2) Scan “Continuous/Trigger off” 3) Scan “Exit” Example 2 Assign Preamble string as “#”, and postamble string as “END” 1) Scan “Enter Group 6” 2) Scan Preamble” 3) Scan “#” from “Full ASCII Table and Table-Hex.” 4) Scan “Confirm” Label in Table-Hex 5) Scan “Postamble” 6) Scan “E”, “N”, “D” from “Full ASCII Table and Table Hex” consecutively 7) Scan “Confirm” Label in Table-Hex. 8) Scan Exit

3

Page 5

Setup Flow Chart ENTER GROUP

SELECT ITEMS

EXIT

Set All Defaults

Show Version

4

Page 6

Group 0: Interface Selection

ENTER GROUP

EXIT

KEYBOARD RS-232

WAND OCIA

RS-232 Reserved 2

DTMF Reserved 4

5

Page 7

Group 1: Device Selection for Keyboard Interface

ENTER GROUP

EXIT

PC/AT, PS/2 50,60,70,80(*) PC/XT

PS/2 25, 30 (NEC 9801)

(IBM 5550) (PS 55)

(NEC N5520) (ACER 7300)

(KW1050D/CT-700A/WANG 5120)

(WANG 5425)

(MAC_SE) (LC-6533)

6

Page 8

Group 1: Device Selection for Keyboard Interface

ENTER GROUP

EXIT

(IBM3196,3197,3476,3477) Reserved Q

Reserved R Reserved T

IBM3197 IBM 3476

IBM3477 RESERVED 5

Reserved 6 RESERVED 7

Reserved 8 RESERVED 9

7

Page 9

Group 2: Intercharacter Delay

ENTER GROUP

EXIT

Start Keyboard Setting Scan Enter Group 2 Label -- > Scan Start Keyboard (or RS-232) Setting Label --> Scan two digits labels in "Table-Hex" --> Scan Exit Label

Start RS-232 Setting Keyboard Default Value: 05 RS-232 Default Value : 00

8

Page 10

Group 3: Language for Keyboard Interface

ENTER GROUP

EXIT

U.S. (*) ENGLAND

FRANCE GERMANY

ITALY BELGIUM

SWEDEN/FINLAND SPANISH

DENMARK PORTUGAL

SWISS NORWAY