Page 11

Group 3: Language for Keyboard Interface

ENTER GROUP

EXIT

CANADA

HOLLAND

POLAND

LATIN

JAPAN RESERVED 1

RESERVED 2 RESERVED 3

(IBM THINK-PAD FOR JAPAN) (PANASONIC CF-II FOR JAPAN)

10

Page 12

Group 4: Terminator

ENTER GROUP

EXIT

KEYBOARD

NONE

CR

SPACE

TAB

ESC

CTRL-C

ESC

11

Page 13

Group 4: Terminator

ENTER GROUP

EXIT

RS-232

NONE

CR

CR/LF

LF

SPACE

TAB

ESC

CTRL-C

STX..ETX

XON.. XOFF

EOT

12

Page 14

Group 5: Scan Mode

ENTER GROUP

EXIT

1: Trigger On/Off 2: Trigger On/Good Read Off (*)

3: Trigger On/Good Read Off/ Delay Timeout = ? 4: Continuous/Trigger Off

5: Continuous/LED Always on 6: Continuous/No Trigger

7: Continuous/Testing 8: Continuous/Trigger Off/ Delay Timeout = ?

13

Page 15

Group 5: Scan Mode

ENTER GROUP

EXIT

FLASH OFF(*) FLASH ON SHORT ZONE LONG ZONE LASER DELAY For Laser Scanner Mode Default Laser Delay Timeout = 60 sec. Scan Enter Group 5 Label Scan Laser Delay --> Refer to the Table-Hex at page 41 and select a value --> Scan Confirm in Table Hex. Scan Exit Label

LAG-960TR - Auto Trigger mode

AUTO TRIGGER Scan Enter Group 5 Label --> Scan 8: Continuous/Trigger off/Delay timeout=? (Page 13) -->

Scan two digit label and "confirm" label in Page 43 --> Scan Above "Auto Trigger Label) Switch on the LAG-960 bottom switch Note: Scan mode setting is only available for CCD/Laser type scanner. 14

Page 16

Group 6: Preamble and Postamble

ENTER GROUP

EXIT

Preamble

Postamble

Preamble & Postamble Setting: Scan Enter Group 6 Label --> Scan Preamble or Postamble Label --> Refer to ASCII Table(page 44), scan two digits in Table-Hex (Page 43) Representing one character, maximum 10 characters can be accepted. --> Scan Confirm Label in Table-Hex (Page 43) Scan Exit Label

Clear Clear Preamble & Postamble : Scan Enter Group 6 Label --> Scan Preamble or Postamble Label --> Scan "Clear" Label--> Scan "Exit" Label

15

Page 17

Group 8: RS-232 Parameters

ENTER GROUP

EXIT

Baud Rate

300 600

1200 2400

4800 9600(*)

19200 38400

Data Bit

BIT 7 BIT 8

16

Page 18

Group 8: RS-232 Parameters

ENTER GROUP

EXIT

Parity :

NONE (*) ODD

EVEN

Handshaking:

NONE (*) XON/OFF

Scanner Ready Data Ready

ACK/NAK

17

Page 19

Group 8: RS-232 Parameters

ENTER GROUP

EXIT

(CK/NAK Response Time CTS Observation Time:)

100 ms 300 ms

500 ms 1 sec.

3 sec (*) 5 sec.

10 sec. 00

18

Page 20

Group 9: CODE 39 / (CODE 32)

ENTER GROUP

EXIT

Enable (*) Disable

Standard (*) Full ASCII Transmit Start/End Character

Disable (*) Enable Transmit Check Character Enable (*) Disable Verify Checksum Enable Disable (*)

Enable CODE 32

19