Page 11
Group 3: Language for Keyboard Interface
ENTER GROUP
EXIT
CANADA
HOLLAND
POLAND
LATIN
JAPAN RESERVED 1
RESERVED 2 RESERVED 3
(IBM THINK-PAD FOR JAPAN) (PANASONIC CF-II FOR JAPAN)
10
Page 12
Group 4: Terminator
ENTER GROUP
EXIT
KEYBOARD
NONE
CR
SPACE
TAB
ESC
CTRL-C
ESC
11
Page 13
Group 4: Terminator
ENTER GROUP
EXIT
RS-232
NONE
CR
CR/LF
LF
SPACE
TAB
ESC
CTRL-C
STX..ETX
XON.. XOFF
EOT
12
Page 14
Group 5: Scan Mode
ENTER GROUP
EXIT
1: Trigger On/Off 2: Trigger On/Good Read Off (*)
3: Trigger On/Good Read Off/ Delay Timeout = ? 4: Continuous/Trigger Off
5: Continuous/LED Always on 6: Continuous/No Trigger
7: Continuous/Testing 8: Continuous/Trigger Off/ Delay Timeout = ?
13
Page 15
Group 5: Scan Mode
ENTER GROUP
EXIT
FLASH OFF(*) FLASH ON SHORT ZONE LONG ZONE LASER DELAY For Laser Scanner Mode Default Laser Delay Timeout = 60 sec. Scan Enter Group 5 Label Scan Laser Delay --> Refer to the Table-Hex at page 41 and select a value --> Scan Confirm in Table Hex. Scan Exit Label
LAG-960TR - Auto Trigger mode
AUTO TRIGGER Scan Enter Group 5 Label --> Scan 8: Continuous/Trigger off/Delay timeout=? (Page 13) -->
Scan two digit label and "confirm" label in Page 43 --> Scan Above "Auto Trigger Label) Switch on the LAG-960 bottom switch Note: Scan mode setting is only available for CCD/Laser type scanner. 14
Page 16
Group 6: Preamble and Postamble
ENTER GROUP
EXIT
Preamble
Postamble
Preamble & Postamble Setting: Scan Enter Group 6 Label --> Scan Preamble or Postamble Label --> Refer to ASCII Table(page 44), scan two digits in Table-Hex (Page 43) Representing one character, maximum 10 characters can be accepted. --> Scan Confirm Label in Table-Hex (Page 43) Scan Exit Label
Clear Clear Preamble & Postamble : Scan Enter Group 6 Label --> Scan Preamble or Postamble Label --> Scan "Clear" Label--> Scan "Exit" Label
15
Page 17
Group 8: RS-232 Parameters
ENTER GROUP
EXIT
Baud Rate
300 600
1200 2400
4800 9600(*)
19200 38400
Data Bit
BIT 7 BIT 8
16
Page 18
Group 8: RS-232 Parameters
ENTER GROUP
EXIT
Parity :
NONE (*) ODD
EVEN
Handshaking:
NONE (*) XON/OFF
Scanner Ready Data Ready
ACK/NAK
17
Page 19
Group 8: RS-232 Parameters
ENTER GROUP
EXIT
(CK/NAK Response Time CTS Observation Time:)
100 ms 300 ms
500 ms 1 sec.
3 sec (*) 5 sec.
10 sec. 00
18
Page 20
Group 9: CODE 39 / (CODE 32)
ENTER GROUP
EXIT
Enable (*) Disable
Standard (*) Full ASCII Transmit Start/End Character
Disable (*) Enable Transmit Check Character Enable (*) Disable Verify Checksum Enable Disable (*)
Enable CODE 32
19