Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 5

IDAutomation SC4USB Scanner Programming Manual, pages 31 to 40

Pages 31 to 40 of 48

The original document is the PDF (542 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the ID Automation SC4

Page 31

Group 15-1: EAN-13/JAN-13

ENTER GROUP EXIT

Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character

Disable Enable (*) Truncate Leading Digit

Disable (*) Enable Truncate Leading Zero

Disable (*) Enable

Check-Digit On (*) Check-Digit Off

30

Page 32

Group 15-2: UPC-A

ENTER GROUP EXIT

Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character

Disable Enable (*) Truncate Leading Digit

Disable (*) Enable Truncate Leading Zero

Disable (*) Enable

31

Page 33

Group 15-3: EAN-8/JAN-8

ENTER GROUP EXIT

Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character

Disable Enable (*) Truncate Leading

Disable (*) Enable EAN Convert to EAN-13

Disable (*) Enable

32

Page 34

Group 15-4: UPC-E / UCC EAN/128

ENTER GROUP EXIT

Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character

Disable Enable (*) Truncate Leading Digit

Disable (*) Enable UCC/EAN/128

Disable (*) Enable UPC-E Convert to UPC-A Disable Enable

33

Page 35

Group 16: General Parameters

ENTER GROUP EXIT

Upper Case Lower Case Universal ALT Mode Buzzer Pitch (Default : 16) Buzzer Duration (Default: 04) Buzzer Pitch & Buzzer Duration Setting: Scan Enter Group 16 Label --> Scan Buzzer Pitch or Buzzer Duration Label --> Scan Two Digit Labels in Table-Hex --> Scan Confirm Label in Table-Hex --> Scan Exit Label Power Up Beeping

Disable Enable (*)

Turbo (*) Normal

34

Page 36

Group 17: Code ID Setting

ENTER GROUP EXIT

CODE 39 INTERLEAVED 2 OF 5

INDUSTRIAL 2 OF 5 MATRIX 2 OF 5

CHINA POSTAGE CODE 128

CODE 93 CODE 11

MSI/PLESSEY CODABAR/NW7

EAN-13/UPC-A EAN-8

UPC-E UPC-A Note: Refer to ASCII Table, scan two hexadecimal labels in Table Hex to represent one character

35

Page 37

Group 18: WAND Type Parameters

ENTER GROUP EXIT

BAR=LOW BAR=HIGH(*) Scan Speed Lowest Low (*) High Highest Data Format

Transmit in Normal Format (*) Transmit in Code 39 Format Transmit in Code 128 Format

36

Page 38

Group 19-1: (Magnetic Parameters)

ENTER GROUP EXIT

Disable Enable (*)

Track Order

Track 1/2/3 (*) Track 1/3/2 Track 2/1/3 Track 2/3/1 Track 3/2/1 Track 3/1/2

Note: Options marked by ( ) are only available upon request

37

Page 39

Group 19-1: (Magnetic Parameters)

ENTER GROUP EXIT

Track Selection Track 1&2&3 any (*) Track 1 only Track 2 only Track 3 only Track 1 and 2 Track 2 and 3 Track 1 and 2 and 3

ISO (*) (JIS-2)

Note: Options marked by ( ) are only available upon request

38

Page 40

Group 19-2: (Magnetic Parameters)

ENTER GROUP EXIT

Start Sentinel: (SS) Tk1 Default : %

Tk2 Default Tk3 Default: ; ?

End Sentinel: (ES) Tk1&2&3 Default: ? DLE: Tk1 Default : Null

Tk2 Default: Null Tk3 Default: Null STX: Tk1&2&3 Default: Null

Magnetic Output Data Format: STX - Tk1 Start Sentinel - Tk1 Data - End Sentinel - Tk1 - DLE STX - Tk2 Start Sentinel - Tk2 Data - End Sentinel - Tk2 - DLE STX - Tk3 Start Sentinel - Tk3 Data - End Sentinel - Tk3 - DLE

Note: Options marked by ( ) are only available upon request

39