The text of a spec sheet · part 17 of 26

Implementing Asset ID: Chapter 5. Integrating with IBM Director, pages 131 to 138

Pages 131 to 138 of 206, from Implementing Asset ID

The original document is the PDF (3.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HID AMH100

Page 131

As described at the beginning of 5.3, “Asset ID support in IBM Director” on page 115, a client can support Asset ID in one of three ways: • Complete, with both the EEPROM and antenna installed • Partial, with just the EEPROM installed • Simulated, with neither the EEPROM nor the antenna installed, but IBM Director uses the file ASSETCI.DAT to store the asset data. To determine what type of Asset ID support a client has, do the following: • Review the Asset tab in the Asset ID window. If the RFID field has a value (264T1U78NLN49 in Figure 90), then the client has both the Asset ID EEPROM and the Asset ID antenna installed. • If the Data space remaining field (see Figure 88 on page 117) is less than 200, but there is no RFID value in the Asset tab, then there is only partial Asset ID support (the EEPROM is installed, but not the antenna) • If the Data space remaining field is greater than 200 (usually close to 1000), then Asset ID support is simulated by IBM Director.

5.4 Reading and writing to Asset ID The process of reading and writing the Asset ID information to a client using IBM Director is very simple: 1. Open the Asset ID task on the client (right-click the system or drag the task onto the system). Note: You can access the Asset ID information only on one client system at a time. You cannot update data to multiple systems at the same time. 2. Click the tab corresponding to the data that you want to read or update. For example, click the User tab.

Chapter 5. Integrating with IBM Director

119

Page 132

Figure 91. User tab

3. If data was already stored in Asset ID, that data will be displayed. Make any changes you required. 4. While the Data space remaining field remains positive, you can enter more data in other fields and in other tabs. However once you’ve exceeded the space available, the Apply button will be greyed out until you remove some characters. 5. To save the changes on all tabs, click Apply. The information is now written to the EEPROM (or the ASSETCI.DAT file on systems where Asset ID is simulated by Netfinity Director). Note: If you close the window without first clicking the Apply button, your changes will not be saved. Ensure you click Apply before closing. 6. Close the Asset ID window.

5.5 Building a query using Asset ID information The information stored in Asset ID can be used for various functions. As we have seen in 4.1, “LANClient Control Manager” on page 50 we used Asset ID to rapidly deploy and redeploy Windows 2000 Professional. As the name indicates, Asset ID is used for identifying assets. Many organizations are now finding leasing beneficial in their environment. However, if you cannot locate your machines or determine when the lease is

120

Implementing Asset ID

Page 133

due, the benefits of leasing are negated and in fact leasing may become detrimental. Asset ID enhances the process of locating machines and determining when machines leases are due. In this section, we use the built-in query functions in IBM Director to determine where our PCs are located and when their leases are up. Note: It is essential that these fields be populated prior to running the query. It doesn’t matter whether these fields get populated through LCCM, IBM Director, or an RFID application such as the Asset ID Starter Kit. In our environment we are using the default database (Microsoft Jet) that ships with IBM Director. 1. Ensure that the IBM Director database has the latest Asset ID information by performing an inventory collection. This should be done before the query is run. Updating the inventory can be done in one of two ways: – Manually, by right-clicking the group All Systems and Devices and clicking Perform Inventory Collection. Click Execute Now to perform the collection immediately, or Schedule to program the collection to occur at a later time. A status window will appear showing the progress of the collection. Notes: a. If you have many systems, requesting inventory on all of them may cause a heavy load on your network. Consider using the schedule option to run the inventory overnight. b. If you have some systems offline, they will return an error in their status in this window.

Chapter 5. Integrating with IBM Director

121

Page 134

Figure 92. Successful inventory collection

– Automatically, by configuring an interval to perform regular inventory collections. Click Options > Server Preferences then in the Inventory Collection Preferences tab, specify how often (in days) you want inventory collected.

Figure 93. Inventory collection preferences

2. Double-click Inventory from the Tasks panel on the main window of the console.

122

Implementing Asset ID

Page 135

Figure 94. Netfinity Director Inventory Query Browser

3. Right-click Custom from the tree view in the left pane and click Build Custom Query. The Inventory Query Builder window appears:

Figure 95. Inventory Query Builder

4. From the Inventory Query Builder window, add the contents from the Lease Information and User Details folders under Available Criteria to the Selected Criteria. To do this, highlight Lease Information and click Add, then highlight User Details and click Add.

Chapter 5. Integrating with IBM Director

123

Page 136

Tip

The information stored in Asset ID is actually stored in multiple queries under the standard folder namely: - Asset ID - Lease information - Personalized Data - Serial Number Information - User Details - Warranty Information

The Query Builder window should now look as follows:

Figure 96. User Details and Lease Information added

5. If you wish, you can change the order of the fields in the Selected Criteria list box. The order you select when the query is saved is the order in which the columns appear when the query is run. – To change the order, drag entries to the new location. Dragging item X on top of item Y will make item X appear below item Y. – An item can be removed by highlighting it and clicking Remove. We reordered our example as shown below:

124

Implementing Asset ID

Page 137

Figure 97. Reordered query

6. Click File > Save from the menu or click

.

7. You will be prompted for a query name. Enter Lease data from Asset ID.

Figure 98. Naming the custom query

8. Click OK. 9. Close the Query Builder. 10.Expand the Custom folder in the Inventory Query Browser window. Click the entry named Lease data from Asset ID. You custom query will now appears:

Chapter 5. Integrating with IBM Director

125

Page 138

Figure 99. Custom Query Browser

11.With this query view, you can sort the information in ascending or descending order by right-clicking the column and selecting the sort method you want. You can sort the data on any column. In addition, you can process the report with other tools: – Export this data to a CSV file using File > Export > Spreadsheet (.CSV) and use a spreadsheet application. – Use the database itself to perform the sorting operations. Since we are using the default Netfinity Director database, Microsoft Jet, we could use Microsoft Access to perform the appropriate sorting and reporting functions. Similarly, if the database is stored in Microsoft SQL Server or IBM DB2, we could use those DBMS applications to analyze the data. With this report, we can see the following: • The second column shows the expiration dates for each of the systems. You can sort on this column to show which systems will have leases that expire soon. • The third column is the system location, which you can use to find where the client PC is located.

126

Implementing Asset ID