The text of a spec sheet · part 16 of 26
Implementing Asset ID: Chapter 5. Integrating with IBM Director, pages 123 to 130
Pages 123 to 130 of 206, from Implementing Asset ID
The original document is the PDF (3.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HID AMH100
Page 123
Chapter 5. Integrating with IBM Director IBM Director (formerly Netfinity Director) is a centralized management tool using industry standard specifications that facilitates the remote management of both servers and clients. Its list of functions is very comprehensive and includes: • Event monitoring • Event action plans • Process management • Remote control • Hardware inventory • Remote hardware configuration • Dynamic and static grouping We will be using IBM Director to remotely configure Asset ID and demonstrate how some of the fields in Asset ID can be used. IBM Director and Netfinity Director
While this chapter refers to IBM Director 2.2, it equally applies to Netfinity Director 2.12. When there are any differences, they are noted.
5.1 Installing IBM Director For detailed instructions on the installation of IBM Director, refer to Chapter 4 and Chapter 6 of the redbook Migrating from Netfinity Manager to Netfinity Director, SG24-6155. In our environment we have the following setup: Domain: ITSO PDC: • Netfinity 5000 • Computer name: ITSOPDC • IP address 9.9.9.9 • Microsoft DHCP services • IBM Director Agent 2.2 (UM Services 2.2) Member server: • Netfinity 3000 • Computer name: ITSOSA4 • IP address 9.9.9.10
© Copyright IBM Corp. 2001
111
Page 124
• Netfinity Director Server 2.12 Member server: • Netfinity 3000 • Computer name: ITSOSA8 • IP Address 9.9.9.11 • IBM Director Server 2.2 Various clients: • Installed with the Netfinity Director 2.12 and IBM Director 2.2 (UM Services) clients Note: For this section we are using Netfinity Director 2.12 and pre-release of IBM Director 2.2. The changes in the interface between 2.12 and 2.2 are minimal.
5.2 Netfinity Director 2.12 patch Netfinity Director 2.12 and earlier have a defect where they do not properly calculate the amount of actual free space available in the Asset ID area. As a result, you are limited to the amount of information you can actually write to the Asset ID EEPROM using Netfinity Director. The patch, IC28527, is available from: http://www.pc.ibm.com/qtechinfo/MIGR-4R4PZ7.html You can also go to http://www.pc.ibm.com/support and search on “IC28527”. Note: This patch should be installed on all Netfinity Director 2.12 clients, servers and consoles. If you do not install the patch, you will be limited as to how much data you can enter via Netfinity Director.
112
Implementing Asset ID
Page 125
Without the patch, Netfinity Director 2.12 incorrectly reports that too many characters have been entered.
Figure 86. Netfinity Director 2.12 incorrectly reports the amount of free space available
In the Netfinity Director Asset ID window, Figure 86, each time an additional character is typed into a field, the counter at the bottom will indicate the amount of total free space that is available for all the fields. The defect is that the calculation for the value of data space remaining is wrong. The result is that much less data can be entered than should be. If too much data is entered, this value will turn to red and display a negative sign, as shown in Figure 86. When this occurs, you will be unable to apply any changes you have made, because the Apply button will be greyed out. If the Asset ID EEPROM has been previously populated by other tools such as an RFID solution from QueTel or using AIAWRITE from LCCM, Netfinity Director will show that information in the dialog box. If Netfinity Director calculates that the space has been overcommitted, you will only be able to read the data but you cannot change it unless you delete enough data to make the free space counter positive again.
5.2.1 Installing the patch on Netfinity Director clients To install the patch on a Netfinity Director 2.12 client, do the following: 1. Log on to the client as a local administrator. 2. Run IC28527.EXE.
Chapter 5. Integrating with IBM Director
113
Page 126
3. Specify the directory where you want the fix unpacked to. 4. After unpacking the fix, the text file LC28527.FIX will be displayed using Notepad. This file contains the instructions on how to install the patch. However, at the time of publication, there were errors in the file. 5. Issue the following command to stop the Windows CIM interface: winmgmt /kill 6. Copy the following two files from the fix installation directory: - Copy ASSETCI.DLL to C:\Program Files\IBM\UMS\CI - Copy IBMASSTW.DLL to C:\Program Files\IBM\UMS 7. Restart the system. The patch is designed to be run on each machine with the Netfinity Director 2.12 already installed and running. If, however, you are deploying 2.12 clients as per the procedures in section 6.2 “Unattended installation of UMS” in the redbook Migrating from Netfinity Manager to Netfinity Director, SG24-6155, we suggest you take the following steps: 1. Create an unattended install file for the Netfinity Director client using the provided SETUP.ISS file. Ensure that the auto reboot option is not enabled. For more information refer to the SETUP.ISS file and README files. 2. Copy the assetci.dll and ibmasstw.dll file to your share. Copy these files from the share to the local system to replace the old files. 3. Create a batch file that will automatically install Netfinity Director client as per step 1 and then run the batch file in step 2. For Windows 2000 Professional it may look something like the following: net use z: \\server\212clnt z:\en\setup -s -sms copy z:\en\assetci.dll C:\Program Files\IBM\UMS\CI /Y copy z:\en\ibmasstw.dll to C:\Program Files\IBM\UMS /Y C: net use z: /delete 4. Use the batch file to run the installation. Note: You will need local administrative rights for the install and first reboot.
5.2.2 Installing the patch on the Netfinity Director server To install the patch on your Netfinity Director 2.12 server, do the following: 1. Log on to the server as a local administrator.
114
Implementing Asset ID
Page 127
2. Run IC28527.EXE. 3. Specify the directory where you want the fix unpacked to. 4. After unpacking the fix, the text file LC28527.FIX will be displayed using Notepad. This file contains the instructions on how to install the patch. However, at the time of publication, there were errors in the file. 5. Copy the following two files from the fix installation directory: – Copy ASSET.JAR to C:\Program Files\IBM\Director\clases\nfdjar – Copy ASSET.SCRIPT.4 to C:\Program Files\IBM\Director\classes\ cimqueryscripts\asset.script (Note: You need to rename the file to ASSET.SCRIPT) – Copy ASSETCI.DLL to C:\Program Files\IBM\Director\UMS\CI – Copy IBMASSTW.DLL to C:\WINNT\System32 6. Restart the server.
5.3 Asset ID support in IBM Director IBM Director, like LCCM, writes to and reads from the Asset ID subsystem via the EEPROM’s system interface (that is, not via the RF interface). Because of this, IBM Director works with systems that have the full Asset ID tag (that is, both the EEPROM and the antenna) plus those systems that just have the Asset ID EEPROM but not the antenna (for example, some ThinkPad models normally do not have the antenna installed as standard). In addition, IBM Director can simulate the functionality of the EEPROM on those systems that do not have Asset ID hardware at all, by reading and writing to a file, ASSETCI.DAT, which is stored in the %WINDIR% directory. On Windows NT and Windows 2000 systems, this is C:\WINNT by default. On Windows 98 systems, this is C:\Windows by default. Note: Unlike the Asset ID EEPROM, the ASSETCI.DAT file can be erased or the C: drive can be formatted, resulting in all Asset ID data lost from those systems. You should take the necessary backup steps to ensure this data is not lost. Asset ID is a task in the IBM Director main window:
Chapter 5. Integrating with IBM Director
115
Page 128
Figure 87. IBM Director/Netfinity Director main window with the Asset ID task
Like other tasks in IBM Director, you can activate Asset ID on a client, in one of two ways: • Drag the Asset ID task onto the client in the Group Contents panel or vice versa. • Right-click the client in the Group Contents panel and click Asset ID from the drop down menu. Note: You cannot drag the task onto multiple systems or a group of systems. The Asset ID task only works on one system at a time. Figure 88 appears:
116
Implementing Asset ID
Page 129
Figure 88. Asset ID task
The tabs in this window correspond to the groups in the User area in the EEPROM as described in 2.1.3, “User area” on page 5. The remaining tabs in the window are as follows:
Figure 89. IBM Director Asset ID interface (System and User)
Chapter 5. Integrating with IBM Director
117
Page 130
Figure 90. IBM Director Asset ID interface (Lease, Asset, Personalization, and Warranty)
118
Implementing Asset ID