Page 28

MAIN PORT CONFIGURATION

8300 Series Information and Examples

Output

BAUD RATE The baud rate is programmable from 300 bits per second to 38,400 bits per second.

PARITY Parity provides a means of checking data bit patterns for validity. The parity should be programmed to match the parity of the terminal being used. If the parity is not set correctly, the resulting data may be incorrect.

DATA BITS The data bits selection must match the requirements of the terminal being used.

PROTOCOL A set of rules governing the exchange of data between communications devices. See Chapter 4 of the SCANTEAM 8300 Technical Manual for complete descriptions of supported protocols.

END OF RECORD Marks the end of an incoming data record from the Auxiliary Port. Use the HEX ASCII chart on page 15 to find the alpha–numeric codes used for programming a particular End of Record. The 8300 does not send End of Record characters to the terminal.

MAIN PORT CTS CHECK If programmed “Yes,” the 8300 will not transmit data until the CTS input is positive.

HOST TO AUX PREFIX Data messages received from the host must have a prefix to identify the message destination as either Aux port 1 or Aux port 2. This selection allows you to program up to a 2 character prefix which will identify each Aux port. (See Chapter 4 of the SCANTEAM 8300 Technical Manual for a complete description of Communication Protocols.) A selection of 00 disables the transmission of data to that aux port.

TRANSMIT HOST TO AUX PREFIX When using the Host to Aux Prefix (see above), you can program whether or not to transmit the Host to Aux prefix character(s).

NAK HOST RECEIVE ERROR This selection programs the 8300 to transmit or not transmit a Hex 15 (NAK) character to the host if a communication error occurs.

26

Page 29

MAIN PORT CONFIGURATION

8300 Series Programming Menu selections scan MAIN PORT CONFIGURATION scan

MAIN PORT CONFIGURATION ENTER MAIN PORT BAUD RATE scan MAIN PORT PARITY

DEFAULT

MAIN PORT DATA BITS

MAIN PORT PROTOCOL scan

EXIT END PROGRAMMING

MAIN PORT END OF RECORD

MAIN PORT CTS CHECK

HOST TO AUX PREFIX variables scan scan

(4 Wire Wedge) to host/terminal

A

(4 Wire Wedge) to host

B

(4 Wire Wedge) to terminal

C

PC Com port

D*

300

A

600

B

1200

C

2400

D

4800

E

9600

F*

19200

G

38400 None

H A

Mark

B

Space

C

Odd

D

Even

E*

Seven

A*

Eight

B

1 stop bit

C*

2 stop bits

D

End of Record

A

60 mS Timeout

B*

TRANZ 330 Protocol

C

ZON JR Protocol

D

Host Command Protocol

E

00–7F

0D*

Yes/No*

Aux 1

A

00–7F (r)*

Aux 2

B

00–7F (s)*

TRANSMIT HOST TO AUX PREFIX

Yes/No*

NAK HOST RECEIVE ERROR

Yes/No*

* Designates default selections.

27

Page 30

AUXILIARY

8300 Series Information and Examples

PORTS 1 and 2

AUX PORT(S) CONFIGURATION The 8300 Auxiliary port menu is used to program the 8300’s auxiliary port communication parameters and protocols.

AUX PORT BAUD RATE The baud rate is programmable from 300 bits per second to 38,400 bits per second.

AUX PORT PARITY Parity provides a means of checking data bit patterns for validity. The parity should be programmed to match the parity of the terminal being used. If the parity is not set correctly, the resulting data may be incorrect.

AUX PORT DATA BITS The data bits selection must match the requirements of the terminal being used.

AUX PORT PROTOCOL This is a set of rules governing the exchange of data between communications devices. See Chapter 4 of the SCANTEAM 8300 Technical Manual for complete descriptions of supported protocols.

AUX PORT END OF RECORD This selection allows you to program a mark for the end of each data record coming in from the aux port. Use the HEX ASCII chart on page 15 to find the alpha–numeric codes used for end-of-record marks. The 8300 does not send end-of-record characters to the terminal.

28

Page 31

AUX PORT(S) CONFIGURATION

8300 Series Programming Menu scan

AUX PORT(S) CONFIGURATION ENTER selections scan

AUX PORT #1 BAUD RATE

AUX PORT #1 PARITY

AUX PORT #1 DATA BITS scan

AUX PORT #1 PROTOCOL

DEFAULT

AUX PORT #1 END OF RECORD AUX PORT #2 BAUD RATE

AUX PORT #2 PARITY

AUX PORT #2 DATA BITS scan scan

300

A

600

B

1200

C

2400

D

4800

E

9600

F*

19200

G

38400 None

H A

Mark

B

Space

C

Odd

D

Even

E*

Seven

A*

Eight

B

1 stop bit

C*

2 stop bits

D

End of Record

A

60 mS Timeout

B*

00–7F

0D*

300

A

600

B

1200

C

2400

D

4800

E

9600

F*

19200

G

38400

H

None

A

Mark

B

Space

C

Odd

D

Even

E*

Seven Eight

A* B

1 stop bit

C*

2 stop bits

D

AUX PORT #2 PROTOCOL

AUX PORT #2 END OF RECORD 4683 ASYNC ADDRESS (AUX PORT # 1 ONLY)

Async Port Disable

A*

$64 Socket 25

B

(2A left)

$65 Socket 25

C

(2B right)

$68 Socket 23

D

(2A left)

$69 Socket 23

E

(2B right)

scan

EXIT END PROGRAMMING variables

End of Record

A

60 mS Timeout

B*

Disable Aux Port #2

C

00–7F

0D*

* Designates default selections.

29

Page 32

Notes: The space below may be used for notes. ...

30

✍

Page 33

8300 Series Information and Examples

DATA FORMATTER

COMMANDS

Note:

For function code mapping, refer to pages 44 through 45.

COMMAND

ACTION

F1

Send all characters followed by “XX” key or function code, starting from current cursor position. ** Syntax = F1XX where XX = HEX ASCII character or function code 00–FE HEX Send “NN” characters followed by “XX” key or function code, starting from current cursor position, leaving cursor pointing to character “NN” + 1. ** Syntax = F2NNXX NN = No. of Characters 00–99 DEC. where XX = HEX ASCII character or function code 00–FE HEX Send up to but not including “SS” character, (** Search and Send**) Starting from current cursor position, leaving cursor pointing to “SS” Char. followed by “XX” key or function code. ** Syntax = F3SSXX SS = HEX ASCII Character 00–FE HEX. where XX = HEX ASCII character 00–FE HEX. Send “XX” character “NN” times, (***INSERT***) Leaving cursor in current cursor position. ** Syntax = F4XXNN where XX = HEX ASCII character 00–FE HEX NN = No. of characters 00–99 DEC. Move cursor ahead “NN” characters from current cursor position. ** Syntax = F5NN NN = No. of characters 00–99 DEC.

F2

F3

F4

F5 F6

Move cursor back “NN” characters from current cursor position. ** Syntax = F6NN NN = No. of characters 00–99 DEC.

F7

Move cursor to the beginning of the data string. ** Syntax = F7

F8

Search ahead for “XX” character from current cursor position, leaving cursor pointing to “XX” char. ** Syntax = F8XX where XX = HEX ASCII character 00–FE.

F9

Search back for “XX” character from current cursor position, leaving cursor pointing to “XX” char. ** Syntax = F9XX where XX = HEX ASCII character 00–FE.

FA

Leading zero suppress on Suppress leading zeroes from current cursor position until 1st non–zero character, leaving cursor pointing to first non-zero character. ** Syntax = FA Suppress “XX” character(s) up to 4 starting from current cursor position until suppress disable command “FC” or end of format. ** Syntax = FBXXFB, FBXXXXFB, FBXXXXXXFB where XX = HEX ASCII character 00–FE.

FB

FC

Disable suppress filter and clear all suppressed characters. ** Syntax = FC

FD

DCA mode ON/OFF (Toggle) Convert characters to DCA starting from current cursor position until next “FD” command or end of format. ** Syntax = FD

FE

Compare character in current cursor position to the character “XX.” If characters are equal, increment cursor. If characters are not equal, no format match. ** Syntax = FEXX where XX = HEX ASCII Character 00 –FE

31

Page 34

DATA FORMATTER

8300 Series Information and Examples

COMMANDS continued

Note:

For function code mapping, refer to pages 44 through 45.

COMMAND

ACTION

E7

Replace up to 5 characters with 5 different characters. **Syntax = E7XXRRXXRRXXRRXXRRXXRRE7 Where XX = character to be replaced RR = replacement character XX and RR = HEX ACSII character 00–FE

E8

Find last (rightmost) occurrence of character and replace with RR, leaving the cursor pointing to RR. **Syntax = E8XXRR

E9

Replace up to 4 characters with RR. **Syntax = E9XXXXXXXXE9RR where XX = HEX ASCII Character 00–FE

EA

Clear – Replace Table.

EB

Sends selected portions of the data string out Aux port #1. This feature toggles off and on. EB signals the 8300 to start sending data out aux port #1; when EB appears again, the rest of the data is sent to the terminal.

EC

Sends 1 or 2 character MICR error/status code. This feature lets you designate where the MICR error/status code should be placed in the data string. The setting of output parameters – MICR error/status codes will determine whether 1 or 2 characters will be output. **Syntax=EC

EE

Leading space suppress on. Suppress leading spaces from current cursor position until first non–space character, leaving cursor pointing to first non-space character. ** Syntax = EE

EF

Delay function. **Syntax = EFXXXX where XXXX = 0000–FFFF x 5ms delay.

32

Page 35

DATA FORMATTER

8300 Series Programming Menu selections scan scan

DATA FORMATTER ENTER scan

Yes/No* scan scan scan

Terminal Code Type (2) ID

Length

(

(

* scan

FORMAT REQUIRED? scan variables

) (

)

*

)

scan

Editor End Command Format Sequences ( ) (FF)

* You may use Universal Number of 99.

Notes: scan

(1) * Designates default selections. (2) For terminal selection, see page 9.

DEFAULT scan

EXIT END PROGRAMMING

33

Page 36

DATA FORMATTER

8300 Series Information and Examples

COMMANDS continued MSR DATA Start/Stop Character Transmit: Start/Stop characters identify the leading and trailing ends of the MSR data. You may either transmit, or not transmit Start/Stop characters. LRC Character Transmit: This setting will enable or disable the transmission of a check digit for mag stripe data. Start and End of MSR Data: Use these selections to program the start/stop characters you wish to use for MSR data. The start and end of MSR data is assigned a special symbology of “FD.” MSR TRACK SELECTION Use this selection if you wish to enable or disable tracks 1, 2, and/or 3. MSR PRE–EDITED DATA FORMATS These selections allow you to program the 8300 to transmit magnetic stripe data in a variety of formats which can include the account number, date, customer name, and any of the key code variables. Note:

Choosing a pre-edited MSR Data Format results in default selections for MSR Data (III). Therefore, Start/Stop Character Transmit and LRC Character Transmit will default to Yes.

KEY CODE ASSIGNMENT Key Codes are variables used to represent values in MSR data formats. Use this selection to assign values to the key codes. Note:

Assignable delimiter or function codes all default to “0D.”

DELETE TERMINAL/CODE SPECIFIC Use this selection to delete any formats which are specific to certain terminal and code ID combinations.

34