Page 19

OUTPUT

8300 Series Programming Menu

PARAMETERS continued selections scan

OUTPUT PARAMETERS ENTER scan

PREFIX

SUFFIX

OUTPUT MODES scan

DEFAULT variables Symbology or 99 Universal (ALL)

scan scan

(See Chart Pg. 15)

Prefix(s) (2,3,4,5,6)

*00–FE

Symbology or 99 Universal (ALL)

(See Chart Pg. 15)

Suffix(s) (2,3,4,5,6)

*00–FE

FF

Buffer Scans

A

Yes/No*

Drivers License ID MSR

B

Yes/No*

Code ID Transmit RS232 Delay

C D

Yes/No* Yes/No*

Track 1 Preferred

E

Yes/No*

IBM 4680/4690 Dual Track MSR Track 1 & 2

F

Yes/No*

IBM 4680/4690 Dual Track MSR Track 2 & 3

G

Yes/No*

Magnetic Sniffer

H

Yes/No*

Ignore Error in Amount Field

I

Yes/No*

Retry exception table parse error

J

*Yes/No

FF scan

EXIT END PROGRAMMING

Notes:

(1) * Designates DEFAULT selections. (2) Scan FF to terminate a prefix or suffix. (3) To clear a prefix or suffix of a particular symbology, scan the symbology and FF. (4) Default clears all prefixes and suffixes of all symbologies. (5) To program Code ID scan the ASCII representation of Code ID on the Symbology and Hex ASCII charts on page 15 of this menu. (6) See Keyboard Layouts on pages 44 through 45 for function code diagrams for various keyboards.

17

Page 20

OUTPUT

8300 Series Information and Examples

PARAMETERS continued OUTPUT MODES WAND/LASER PORT MODES Hand Held Laser Timeout: This programs a timeout for a hand-held laser compatible scanner. The scanner turns off after the trigger is depressed for 4 seconds. Laser Redundancy: If programmed ‘’Yes,” the 8300 requires three identical scans before data will be accepted. If disabled, the 8300 accepts data after a single valid scan. MICR ERROR/STATUS CODES Use this option to output either a single or double character when there is a MICR Error/Status code to report. This selection also allows you to dump out any MICR data read on an error condition. Note: For Error Conditions When the MICR code on the check is in error and a triple beep occurs, the error code will only be output when this selection is set to single or double character. Note: For Status Conditions When the MICR code on the check is not in error but does have some other status condition to report (i.e., serial number in range 151–300), this status code will only be output when this selection is set to single or double character AND the placement of the status code is set by either a prefix/suffix or data formatter command. Note: For Placement and programmable MICR Error/Status Codes All MICR error/status code values can be programmed – see the MICR Data Formatter (page 39) to do this. To place the error/status code at the beginning or end of a MICR output string, use EC as the ASCII value when programming in a prefix/suffix. To place the error/status code in the middle of a MICR output string, use the EC Data Formatter Command. TRANSMISSION RATE CONTROLS The Transmission Rate Controls can be used to speed up or slow down transmission when the check reader is interfacing keyboard wedge with a termial ID 03. Use these selections to control how much delay there is between make/break sequences when wedging in keyboard data. Interrupt Time: Use this selection to control the amount of interrupt time between characters output. Delay time Shift/CTRL Sequence: Use this selection to control the amount of delay time between make/break codes when outputting a shifted or CTRL key character. Delay Time Normal Sequence: Use this selection to control the amount of delay time between make/break codes when outputting a normal data key character.

18

Page 21

OUTPUT

8300 Series Programming Menu

PARAMETERS continued selections scan variables

WAND/LASER PORT MODES

Hand Held Laser Timeout

MICR ERROR/STATUS CODES

TRANSMISSION RATE CONTROLS scan

OUTPUT PARAMETERS ENTER scan

DEFAULT scan scan

A

*Yes/No

Laser Redundancy

B

Yes/No*

None

A*

Single Character

B

Double Character

C

Dump Data on Error

D

Yes/No*

Interrupt Time

A

01–05 (x1ms) (*05)

Delay Time Shift/CTRL Sequence

B

01–10 (x1ms) (*10)

Delay Time Normal Sequence

C

01–10 (x1ms) (*05)

Notes:

(1) * Designates DEFAULT selections.

scan

EXIT END PROGRAMMING

19

Page 22

Notes: The space below may be used for notes. ...

20

✍

Page 23

8300 Series Information and Examples

CODES

INDUSTRIAL INDUSTRIAL CODE OUTPUT FORMATS Code 39 bSXX . . XXCS Code 128 jXX . . . . XX Interleaved 2 of 5 eXX . . . XXC Where: b = Code 39 ID j = Code 128 ID e = Interleaved 2 or 5 ID S = Start/Stop Character X = Data Character C = Check Character Note:

Appropriate code identification must be programmed in a prefix. For maximum data security, disable the codes not used.

MIN/MAX LENGTH FOR ALL SYMBOLOGIES This selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the 8300 will issue an error code. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9–20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15

CODE 39 Start/Stop Transmit Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Check Character Required When this feature is set to “Yes,” the 8300 will not read a Code 39 bar code printed without the check character. Transmit Check Character When this feature is set to “Yes,” the 8300 transmits the bar code check character at the end of the scanned data.

21

Page 24

CODES

8300 Series Information and Examples

INDUSTRIAL continued

FULL ASCII CODE 39 CHARACTERS If full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. FULL ASCII Code 39 CHART NUL %U SOH $A STX $B ETX $C EOT $D ENQ $E ACK $F BEL $G BS $H HT $I LF $J VT $K FF $L CR $M SO $N SI $O

DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

$P $Q $R $S $T $U $V $W $X $Y $Z %A %B %C %D %E

SP ! ” # $ % & ’ ( ) * + , – . /

SPACE /A /B /C /D /E /F /G /H /I /J /K /L – . /O

0 1 2 3 4 5 6 7 8 9 : ; < = > ?

0 1 2 3 4 5 6 7 8 9 /Z %F %G %H %I %J

@ A B C D E F G H I J K L M N O

%V A B C D E F G H I J K L M N O

P Q R S T U V W X Y Z [ \ ] ^ _

P Q R S T U V W X Y Z %K %L %M %N %0

‘ a b c d e f g h i j k l m n o

%W +A +B +C +D +E +F +G +H +I +J +K +L +M +N +O p +P q +Q r +R s +S t +T u +U v +V w +W x +X y +Y z +Z { %P | %Q } %R ~ %S DEL %T

Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9. APPEND OPTION This function allows the 8300 to append the data from several Code 39 bar codes together before transmitting them to the host computer. When this function is enabled, the scanner stores those Code 39 bar codes that start with a space (excluding the start and stop symbols), and doesn’t immediately transmit the data. The scanner stores the data in the order in which the bar codes are read, deleting the first space from each. The scanner transmits the appended data when it reads a Code 39 bar code that starts with a character other than a space, or when it reads a bar code which is not Code 39. INTERLEAVED 2 OF 5 6, 14, & 16 Only: When this function is set to “Yes,” the 8300 sets the minimum length to 5 and the maximum length to 16. Check Digit Required: When Check Digit Required is set to “Yes,” the 8300 will not read an Interleaved 2 of 5 bar code printed without the check character. Transmit Check Character: When set to “Yes,” the 8300 transmits the bar code check character at the end of the scanned data. DECODING ALGORITHM This selection sets the decoding aggressiveness of the 8300. Adaptive decoding allows the 8300 to decode bar codes which are out of tolerance, and which do not conform to symbology specifications. Traditional decoding ensures correct decoding, and does not allow variances from bar code specifications.

22

Page 25

CODE

8300 Series Programming Menu

SELECTION I

(INDUSTRIAL)

selections scan scan CODE 39

ID = b (HEX 62)

CODE SELECTION I ENTER scan variables scan scan

A B C D

*Yes/No *00–Max Min–48* Yes/No* Yes/No*

E

Yes/No*

Full ASCII

F

*Yes/No

Append Option

G

Yes/No*

A

*02–Max

Maximum Length

B

Min–80*

6, 14, & 16 Only

C

Yes/No*

Check Digit Required

D

Yes/No*

Xmit Check Digit

E

Yes/No*

Minimum Length

A

*00–Max

Maximum Length

B

Min–80*

Enable Minimum Length Maximum Length Start/Stop Transmit Check Character Required Transmit Check Character

INTERLEAVED 2 OF 5

ID =e (HEX 65)

DEFAULT CODE 128

ID = j (HEX 6A)

DISABLE ALL CODES (Including Retail) DECODING ALGORITHM

Enable

*Yes/No

Minimum Length

Enable

*Yes/No

Yes/No* Code 39

B

Adaptive *Y/N

* Designates default selections.

scan

EXIT END PROGRAMMING

23

Page 26

CODES

8300 Series Information and Examples

RETAIL

RETAIL CODE OUTPUT FORMATS Note:

Appropriate code identification must be programmed in a prefix. For maximum data security, disable the Codes not used.

UPC Version A: UPC–A is a 12 digit UPC code. Either a 2 digit or a 5 digit addenda may be added if your application needs to decode a 2 or 5 digit addenda to the UPC–A code. If your application does require addenda, you must also program it for UPC & EAN Addenda Required, selection III. Version E: UPC–E is an 8 digit UPC code. Either a 2 digit or a 5 digit addenda may be added if your application needs to decode a 2 or 5 digit addenda to the UPC–E code. If your application does require addenda, you must also program it for UPC & EAN Addenda Required, selection III. Most UPC bar codes lead with the 0 number system. For these codes, use the Version E0 selection. If you need to read codes which lead with the 1 number system, use the Version E1 selection. You may also wish to enable Version E Expand, if you need to expand the UPC–E code to the 12 digit, UPC–A format. (This selection is only available with Version E0.) CHECK DIGIT TRANSMIT This feature enables or disables check digit transmission. NUMBER SYSTEM TRANSMIT The numeric system digit of a UPC symbol is normally transmitted, but the 8300 can be programmed to disable it. EAN/JAN Use this selection to program the 8300 to decode EAN/JAN, either 8 digit or 13 digit code. Either a 2 digit or a 5 digit addenda may be added if your application needs to decode a 2 or 5 digit addenda to the EAN/JAN code. If your application does require addenda, you must also program it for UPC & EAN Addenda Required, selection III. Note:

If you have programmed the 8300 to decode EAN/JAN 13, but not UPC–A, UPC–A bar codes will be read as EAN/JAN–13 codes.

SPACE BETWEEN UPC/EAN ADDENDA This selection allows you to specify if you wish to transmit a space between the UPC or EAN bar code and the addenda characters.

24

Page 27

CODE

8300 Series Programming Menu

SELECTION II (RETAIL)

scan selections scan variables scan scan

ID = c (HEX 63)

Version A

A

*Yes/No

Version E0 Version E1 Check Digit Xmit Number System Xmit Version E Expand 2–Digit Addenda 5–Digit Addenda

C D E F G H I

*Yes/No *Yes/No Yes/No Yes/No Yes/No* *Yes/No *Yes/No

ID = d (HEX 64)

EAN/JAN 13 EAN/JAN 8 Check Digit Xmit 2–Digit Addenda 5–Digit Addenda

A B C D E

*Yes/No *Yes/No Yes/No *Yes/No *Yes/No

UPC & EAN ADDENDA REQ’D.

Enable

Yes/No*

SPACE BETWEEN UPC / EAN ADDENDA REQ’D.

Enable

*Yes/No

UPC CODE SELECTION II ENTER

EAN scan

DEFAULT

* Designates default selections.

scan

EXIT END PROGRAMMING

25