Page 37
DATA FORMATTER continued
8300 Series Programming Menu scan selections scan variables scan scan
MSR DATA
Start/Stop Char. Transmit
A
*Yes/No
LRC Char. Transmit
B
*Yes/No
Start of MSR Data
C
00–7F
End of MSR Data
D
00–7F
Track 1 Enable
A
*Yes/No
Track 2 Enable
B
*Yes/No
Track 3 Enable Clear Pre–edited Data Format Acct # + Key–Code 1
C
*Yes/No
DATA FORMATTER ENTER MSR TRACK SELECTION
MSR TRACK 2 PRE–EDITED DATA FORMATS
Acct # + Key–Code 1 + YYMM + Key–Code 2 Acct # + Key–Code 1 + MMYY + Key–Code 2 scan
DEFAULT
MSR TRACK 1 PRE–EDITED DATA FORMATS
KEY–CODE 1–4 ASSIGNMENT
DELETE TERMINAL/CODE SPECIFIC
DELETE ALL FORMATS
Clear Pre–edited Data Format Acct # + Key–Code 1 + YYMM + Key–Code 2 + Name + Key–Code 3 Acct # + Key–Code 1 + MMYY + Key–Code 2 + Name + Key–Code 3
A B C D
A B
C
Key–Code 1 (E0H)
A
Key–Code 2 (E1H)
B
Key–Code 3 (E2H)
C
Key–Code 4 (E3H)
D Terminal Type (*)
Are You Sure?
00–FE *0D 00–FE *0D 00–FE *0D 00–FE *0D Code ID (*) Yes/No
* Designates default selections.
scan
EXIT END PROGRAMMING
35
Page 38
DATA FORMATTER continued
8300 Series Information and Examples
Formatting MICR Output Example Scenario: You have the following data on a check: You have set the MICR Data Formatter output format to 02, which is <TRANSIT#>T<ACCOUNT#>A<CHECK SERIAL #> The output you would like is: 021300381<CR> 324036091<CR> 4973 Solution: Go to page 33 (Data Formatter). Step 1.
Scan ENTER.
Step 2.
Scan XX, then Yes to clear previous formats (this choice is from page 35).
Step 3.
Scan II to enter Data Formatting parameters Scan 99 for universal terminal type Scan 74 for MICR symbology Scan 99 for variable length
Step 4. Scan your format parameters (scan each character in order): FB 20 64 FB F3 54 0D F5 01 F3 41 0D F5 01 F1 0D FF Why: FB 20 64 FB F3 54 0D F5 01 F3 41 0D F5 01 F1 0D FF Step 5.
36
FB suppresses characters, and you want to suppress spaces and dashes. Sends everything up to a T (hex 54), followed by a <CR> (hex 0D). Moves the cursor past the T. Sends everything up to an A (hex 41), followed by a <CR> (hex 0D). Moves the cursor past the A. Sends the rest of the code, followed by a <CR> (hex 0D). Termination character for end of format.
Scan EXIT END PROGRAMMING.
Page 39
DATA FORMATTER
8300 Series Information and Examples
Bar Code Example (Commercial) Scenario: You need to read a 6–digit bar code printed in Interleaved 2 of 5. Only the first five digits of the code will be transmitted. You want the transmitted code terminated with a vertical tab and a horizontal tab. Solution: Go to page 33 (Data Formatter): Step 1. Scan ENTER. Step 2.
Scan XX and Yes to clear previous formats.
Step 3.
Scan II to enter Data Formatting parameters. Scan 03 for terminal type (PC) Scan 65 for Code I 2 of 5 Symbology (see the Symbology chart on page 15). Scan 06 for fixed length code.
Step 4.
Scan your format parameters (scan each character in order): F2 05 0B F4 09 01 FF Why: F2 05 0B: F2 sends XX number of characters followed by a function code. Sends the first five characters of the label followed by a vertical tab. (Hex 0B) F4 09 01: Appends one hex 09 (a horizontal tab) at the end of the label. FF: Termination character for end of format.
Step 5.
Scan EXIT END PROGRAMMING.
Scan the bar code labels below to check your data formatting.
I2/5 056876
I2/5 087987 To set minimum required default parameters for IBM 4683 interface, set your Output Parameters to IV (on page 11), then scan DATA FORMATTER ENTER, DEFAULT and EXIT END PROGRAMMING from page 35 .
37
Page 40
MICR DATA FORMATTER
8300 Series Information and Examples
MINIMUM AND MAXIMUM MICR SIGNAL LEVEL These selections allow you to set the range for acceptable MICR signals. SELECT MICR OUTPUT FORMAT Use the following selections with the programming choices on page 39 to program a custom MICR Data Format. MICR Field Name
MICR ID #
Entire MICR Line Auxiliary On Us External Processing Code (EPC) Routing ONUS Amount Check # Account # Process Control Code
00 01 02 03 04 05 06 07 08
MICR Field Length
Selection
Zero (Field Disabled) Fixed Length Variable Length
00 XX (where XX is the HEX ASCII Representation 00–7F) 99
MICR Field Fill
Selection
Any character
XX (where XX is the HEX ASCII Representation 00–7F)
Note: MICR field length must be programmed for fixed length when using Field Fill.
MICR Field Justify
Selection
Left Justify Right Justify
00 01
Note: MICR field length must be programmed for fixed length when using Field Justify.
MICR PROGRAMMING CHECKS - EQUIVALENTS TO BAR CODES Roman Numerals
Roman Numerals
Letters
I t1
XI o1
A a1
0 (YES)
d0
ESCAPE tt0
II t2
XII o2
B a2
1 (NO)
d1
DEFAULT tt1
III t3
XIII o3
C a3
2 d2
EXIT tt2
IV t4
XIV o4
D a4
3 d3
END PROG tt3
V t5
XV o5
E a5
4 d4
VI t6
XVI o6
F a6
5 d5
VII t7
XVII o7
G a7
6 d6
VIII t8
XVIII o8
H a8
7 d7
IX t9
XIX o9
I a9
8 d8
X t0
XX o0
J a0
9 d9
38
Digits
Others where: t =
(transit symbol)
a =
(amount symbol)
o =
(On Us symbol)
d =
(dash symbol)
Page 41
MICR DATA FORMATTER
8300 Series Programming Menu selections scan
MICR DECODING variables Auto Discrimination
A
E13–B Only
B*
CMC–7 Only scan
MICR DATA FORMATTER ENTER scan
DEFAULT
MINIMUM MICR SIGNAL LEVEL MAXIMUM MICR SIGNAL LEVEL SELECT MICR OUTPUT FORMAT
Note: ASCII characters transmitted in place of E13–B symbols: t = Transit symbol o = On Us symbol a = amount symbol d = dash symbol scan
C
*$00–$FE
$00–$FE*
<ENTIRE MICR LINE UN–EDITED (RAW MICR)> NO EXCEPTIONS Includes spaces and symbols Field format rules not verified
00*
Custom Format (See V, VI, VII)
01
<TRANSIT #>T<ACCOUNT #>A <CHECK SERIAL #> Account #: no space, dash, or On Us
02
<TRANSIT #>T<14 DIGIT ACCOUNT #>A<6 DIGIT CHECK SERIAL #> Account #: No spaces or dashes, zero filled, right justified Check #: zero filled, right justified
03
<TRANSIT #>T<ACCOUNT #>A <CHECK SERIAL #> Account #: includes spaces and dashes, but no On Us.
04
<ENTIRE MICR LINE UN–EDITED (RAW MICR)> Includes spaces and symbols Field format rules verified
98
<ENTIRE MICR LINE UN–EDITED (RAW MICR)> includes spaces and symbols Field format rules not verified A question mark (?) will be sent for unreadable characters
99 Test Mode
* Designates default selections.
scan
EXIT END PROGRAMMING
39
Page 42
MICR DATA FORMATTER
8300 Series Examples continued MICR Data Example #1 Custom Format Scenario: Output a known check format where 0001 is the check number. Check Data: t123456789t987–654321o–0001 Desired custom output: <transit #>T<check #>S<account #>A Solution: Scan the following series: MICR DATA FORMATTER ENTER IV V V V VI VI VI VII
01 03 FB 74 FB F1 54 FF 07 F1 41 FF 06 F1 53 FF 03 99 00 00 FF 07 99 00 00 FF 06 99 00 00 FF 03 06 07 FF
(custom format) (format routing buffer) (format account # buffer) (format check # buffer) (routing buffer variable length) (account # buffer variable length) (check # buffer variable length) (order of buffer output)
EXIT END PROGRAMMING
MICR Data Example #2 Exception Table Parsing Scenario: Output a check with exception table entry where 0001 is the check number. Check Data: t123456789t987–654321o2220001 Desired output: <transit #>T<account #>A<check #> Solution: Scan the following series: MICR DATA FORMATTER ENTER IX 1 2 3 4 5 6 7 8 F2 14 5A F2 04 5A F1 00 FF EXIT END PROGRAMMING
MICR Data Example #3 Custom Format plus Data Formatter Scenario: Output only the account number from a check, followed by a carriage return. Solution: Scan the following series: MICR DATA FORMATTER ENTER IV 02 (Transit t, Account a) EXIT END PROGRAMMING DATA FORMATTER ENTER II 99 (terminal) 74 (code ID – MICR) 99 (variable length) F8 54 F5 01 F3 41 0D FF EXIT END PROGRAMMING
40
Page 43
MICR DATA FORMATTER continued
8300 Series Programming Menu selections scan
CUSTOM MICR FORMAT FIELD EDIT
V
CUSTOM MICR FORMAT FIELD ATTRIBUTE(S)
VI variables scan scan scan scan
Field ID
Editor Command Sequence
$FF scan scan scan
Field ID
Field Length (HEX Value)
Field Fill scan scan
None* scan
MICR DATA FORMATTER ENTER scan
DEFAULT
None*
Field Justify $FF
CUSTOM MICR FORMAT FIELD OUTPUT ORDER
VII
ACTIVATE EXCEPTION TABLE PARSING
VIII
EXCEPTION TABLE PARSING (2, 3)
IX scan scan
Order of Output 00–08
$FF
None*
*Yes/No scan Transit Number scan scan
Editor Command Sequence
$FF
None* scan
EXIT END PROGRAMMING
(1) * Designates DEFAULT selections. (2) Exception table parsing is activated in the event that the canned format or custom MICR format does not correctly parse a particular bank’s On Us field. (3) Refer to MICR example #2 on page 40. Exception Table Parsing will be invoked only on those checks where the routing (transit) numbers match the transit number in the format.
41
Page 44
MICR DATA FORMATTER
8300 Series Examples continued MICR ERROR/STATUS CODES Use the MICR/ERROR status codes to control the values for all possible MICR error/status codes. Each character must be from the HEX–ASCII table. For example, to program No MICR to a value of “XY”: MICR DATA FORMATTER ENTER, XI, B, 58, 59, EXIT When the OUTPUT PARAMETERS MICR ERROR/STATUS CODE is programmed to single character, only the second character for that particular error/status code will be output. In the above example, only “Y” will be output.
42
Page 45
MICR DATA FORMATTER continued
8300 Series Programming Menu scan
MICR DATA FORMATTER ENTER scan selections scan variables
DELETE SPECIFIC EXCEPTION TABLE
IX scan
DELETE ALL EXCEPTION TABLE PARSING ENTRIES
X
MICR ERROR/STATUS CODES
XI
Transit Number scan scan
D0 scan
None*
$FF
Yes/No
Are you sure?
No Errors (Good Read)
A
No MICR
B
00–7F (00)* 00–7F (01)*
Low Signal
C
00–7F (02)*
Serial # not present
D
00–7F (03)*
Invalid ABA #
E
00–7F (04)*
Parser Error
F
00–7F (05)*
Acct. # Error
G
00–7F (06)*
Canadian Check
H
00–7F (07)*
Mexican Check
I
00–7F (08)*
Bad Data
J
00–7F (09)*
SN Range 1–150
XV
00–7F (10)*
SN Range 151–300
XVI
00–7F (11)*
SN Range 301–500
XVII
00–7F (12)*
Business Check
XVIII
00–7F (13)*
Old U. S.
XIX
00–7F (14)*
Traveler’s Check
XX
00–7F (15)*
DEFAULT
(1) * Designates DEFAULT selections.
scan
EXIT END PROGRAMMING
43