Page 37

DATA FORMATTER continued

8300 Series Programming Menu scan selections scan variables scan scan

MSR DATA

Start/Stop Char. Transmit

A

*Yes/No

LRC Char. Transmit

B

*Yes/No

Start of MSR Data

C

00–7F

End of MSR Data

D

00–7F

Track 1 Enable

A

*Yes/No

Track 2 Enable

B

*Yes/No

Track 3 Enable Clear Pre–edited Data Format Acct # + Key–Code 1

C

*Yes/No

DATA FORMATTER ENTER MSR TRACK SELECTION

MSR TRACK 2 PRE–EDITED DATA FORMATS

Acct # + Key–Code 1 + YYMM + Key–Code 2 Acct # + Key–Code 1 + MMYY + Key–Code 2 scan

DEFAULT

MSR TRACK 1 PRE–EDITED DATA FORMATS

KEY–CODE 1–4 ASSIGNMENT

DELETE TERMINAL/CODE SPECIFIC

DELETE ALL FORMATS

Clear Pre–edited Data Format Acct # + Key–Code 1 + YYMM + Key–Code 2 + Name + Key–Code 3 Acct # + Key–Code 1 + MMYY + Key–Code 2 + Name + Key–Code 3

A B C D

A B

C

Key–Code 1 (E0H)

A

Key–Code 2 (E1H)

B

Key–Code 3 (E2H)

C

Key–Code 4 (E3H)

D Terminal Type (*)

Are You Sure?

00–FE *0D 00–FE *0D 00–FE *0D 00–FE *0D Code ID (*) Yes/No

* Designates default selections.

scan

EXIT END PROGRAMMING

35

Page 38

DATA FORMATTER continued

8300 Series Information and Examples

Formatting MICR Output Example Scenario: You have the following data on a check: You have set the MICR Data Formatter output format to 02, which is <TRANSIT#>T<ACCOUNT#>A<CHECK SERIAL #> The output you would like is: 021300381<CR> 324036091<CR> 4973 Solution: Go to page 33 (Data Formatter). Step 1.

Scan ENTER.

Step 2.

Scan XX, then Yes to clear previous formats (this choice is from page 35).

Step 3.

Scan II to enter Data Formatting parameters Scan 99 for universal terminal type Scan 74 for MICR symbology Scan 99 for variable length

Step 4. Scan your format parameters (scan each character in order): FB 20 64 FB F3 54 0D F5 01 F3 41 0D F5 01 F1 0D FF Why: FB 20 64 FB F3 54 0D F5 01 F3 41 0D F5 01 F1 0D FF Step 5.

36

FB suppresses characters, and you want to suppress spaces and dashes. Sends everything up to a T (hex 54), followed by a <CR> (hex 0D). Moves the cursor past the T. Sends everything up to an A (hex 41), followed by a <CR> (hex 0D). Moves the cursor past the A. Sends the rest of the code, followed by a <CR> (hex 0D). Termination character for end of format.

Scan EXIT END PROGRAMMING.

Page 39

DATA FORMATTER

8300 Series Information and Examples

Bar Code Example (Commercial) Scenario: You need to read a 6–digit bar code printed in Interleaved 2 of 5. Only the first five digits of the code will be transmitted. You want the transmitted code terminated with a vertical tab and a horizontal tab. Solution: Go to page 33 (Data Formatter): Step 1. Scan ENTER. Step 2.

Scan XX and Yes to clear previous formats.

Step 3.

Scan II to enter Data Formatting parameters. Scan 03 for terminal type (PC) Scan 65 for Code I 2 of 5 Symbology (see the Symbology chart on page 15). Scan 06 for fixed length code.

Step 4.

Scan your format parameters (scan each character in order): F2 05 0B F4 09 01 FF Why: F2 05 0B: F2 sends XX number of characters followed by a function code. Sends the first five characters of the label followed by a vertical tab. (Hex 0B) F4 09 01: Appends one hex 09 (a horizontal tab) at the end of the label. FF: Termination character for end of format.

Step 5.

Scan EXIT END PROGRAMMING.

Scan the bar code labels below to check your data formatting.

I2/5 056876

I2/5 087987 To set minimum required default parameters for IBM 4683 interface, set your Output Parameters to IV (on page 11), then scan DATA FORMATTER ENTER, DEFAULT and EXIT END PROGRAMMING from page 35 .

37

Page 40

MICR DATA FORMATTER

8300 Series Information and Examples

MINIMUM AND MAXIMUM MICR SIGNAL LEVEL These selections allow you to set the range for acceptable MICR signals. SELECT MICR OUTPUT FORMAT Use the following selections with the programming choices on page 39 to program a custom MICR Data Format. MICR Field Name

MICR ID #

Entire MICR Line Auxiliary On Us External Processing Code (EPC) Routing ONUS Amount Check # Account # Process Control Code

00 01 02 03 04 05 06 07 08

MICR Field Length

Selection

Zero (Field Disabled) Fixed Length Variable Length

00 XX (where XX is the HEX ASCII Representation 00–7F) 99

MICR Field Fill

Selection

Any character

XX (where XX is the HEX ASCII Representation 00–7F)

Note: MICR field length must be programmed for fixed length when using Field Fill.

MICR Field Justify

Selection

Left Justify Right Justify

00 01

Note: MICR field length must be programmed for fixed length when using Field Justify.

MICR PROGRAMMING CHECKS - EQUIVALENTS TO BAR CODES Roman Numerals

Roman Numerals

Letters

I t1

XI o1

A a1

0 (YES)

d0

ESCAPE tt0

II t2

XII o2

B a2

1 (NO)

d1

DEFAULT tt1

III t3

XIII o3

C a3

2 d2

EXIT tt2

IV t4

XIV o4

D a4

3 d3

END PROG tt3

V t5

XV o5

E a5

4 d4

VI t6

XVI o6

F a6

5 d5

VII t7

XVII o7

G a7

6 d6

VIII t8

XVIII o8

H a8

7 d7

IX t9

XIX o9

I a9

8 d8

X t0

XX o0

J a0

9 d9

38

Digits

Others where: t =

(transit symbol)

a =

(amount symbol)

o =

(On Us symbol)

d =

(dash symbol)

Page 41

MICR DATA FORMATTER

8300 Series Programming Menu selections scan

MICR DECODING variables Auto Discrimination

A

E13–B Only

B*

CMC–7 Only scan

MICR DATA FORMATTER ENTER scan

DEFAULT

MINIMUM MICR SIGNAL LEVEL MAXIMUM MICR SIGNAL LEVEL SELECT MICR OUTPUT FORMAT

Note: ASCII characters transmitted in place of E13–B symbols: t = Transit symbol o = On Us symbol a = amount symbol d = dash symbol scan

C

*$00–$FE

$00–$FE*

<ENTIRE MICR LINE UN–EDITED (RAW MICR)> NO EXCEPTIONS Includes spaces and symbols Field format rules not verified

00*

Custom Format (See V, VI, VII)

01

<TRANSIT #>T<ACCOUNT #>A <CHECK SERIAL #> Account #: no space, dash, or On Us

02

<TRANSIT #>T<14 DIGIT ACCOUNT #>A<6 DIGIT CHECK SERIAL #> Account #: No spaces or dashes, zero filled, right justified Check #: zero filled, right justified

03

<TRANSIT #>T<ACCOUNT #>A <CHECK SERIAL #> Account #: includes spaces and dashes, but no On Us.

04

<ENTIRE MICR LINE UN–EDITED (RAW MICR)> Includes spaces and symbols Field format rules verified

98

<ENTIRE MICR LINE UN–EDITED (RAW MICR)> includes spaces and symbols Field format rules not verified A question mark (?) will be sent for unreadable characters

99 Test Mode

* Designates default selections.

scan

EXIT END PROGRAMMING

39

Page 42

MICR DATA FORMATTER

8300 Series Examples continued MICR Data Example #1 Custom Format Scenario: Output a known check format where 0001 is the check number. Check Data: t123456789t987–654321o–0001 Desired custom output: <transit #>T<check #>S<account #>A Solution: Scan the following series: MICR DATA FORMATTER ENTER IV V V V VI VI VI VII

01 03 FB 74 FB F1 54 FF 07 F1 41 FF 06 F1 53 FF 03 99 00 00 FF 07 99 00 00 FF 06 99 00 00 FF 03 06 07 FF

(custom format) (format routing buffer) (format account # buffer) (format check # buffer) (routing buffer variable length) (account # buffer variable length) (check # buffer variable length) (order of buffer output)

EXIT END PROGRAMMING

MICR Data Example #2 Exception Table Parsing Scenario: Output a check with exception table entry where 0001 is the check number. Check Data: t123456789t987–654321o2220001 Desired output: <transit #>T<account #>A<check #> Solution: Scan the following series: MICR DATA FORMATTER ENTER IX 1 2 3 4 5 6 7 8 F2 14 5A F2 04 5A F1 00 FF EXIT END PROGRAMMING

MICR Data Example #3 Custom Format plus Data Formatter Scenario: Output only the account number from a check, followed by a carriage return. Solution: Scan the following series: MICR DATA FORMATTER ENTER IV 02 (Transit t, Account a) EXIT END PROGRAMMING DATA FORMATTER ENTER II 99 (terminal) 74 (code ID – MICR) 99 (variable length) F8 54 F5 01 F3 41 0D FF EXIT END PROGRAMMING

40

Page 43

MICR DATA FORMATTER continued

8300 Series Programming Menu selections scan

CUSTOM MICR FORMAT FIELD EDIT

V

CUSTOM MICR FORMAT FIELD ATTRIBUTE(S)

VI variables scan scan scan scan

Field ID

Editor Command Sequence

$FF scan scan scan

Field ID

Field Length (HEX Value)

Field Fill scan scan

None* scan

MICR DATA FORMATTER ENTER scan

DEFAULT

None*

Field Justify $FF

CUSTOM MICR FORMAT FIELD OUTPUT ORDER

VII

ACTIVATE EXCEPTION TABLE PARSING

VIII

EXCEPTION TABLE PARSING (2, 3)

IX scan scan

Order of Output 00–08

$FF

None*

*Yes/No scan Transit Number scan scan

Editor Command Sequence

$FF

None* scan

EXIT END PROGRAMMING

(1) * Designates DEFAULT selections. (2) Exception table parsing is activated in the event that the canned format or custom MICR format does not correctly parse a particular bank’s On Us field. (3) Refer to MICR example #2 on page 40. Exception Table Parsing will be invoked only on those checks where the routing (transit) numbers match the transit number in the format.

41

Page 44

MICR DATA FORMATTER

8300 Series Examples continued MICR ERROR/STATUS CODES Use the MICR/ERROR status codes to control the values for all possible MICR error/status codes. Each character must be from the HEX–ASCII table. For example, to program No MICR to a value of “XY”: MICR DATA FORMATTER ENTER, XI, B, 58, 59, EXIT When the OUTPUT PARAMETERS MICR ERROR/STATUS CODE is programmed to single character, only the second character for that particular error/status code will be output. In the above example, only “Y” will be output.

42

Page 45

MICR DATA FORMATTER continued

8300 Series Programming Menu scan

MICR DATA FORMATTER ENTER scan selections scan variables

DELETE SPECIFIC EXCEPTION TABLE

IX scan

DELETE ALL EXCEPTION TABLE PARSING ENTRIES

X

MICR ERROR/STATUS CODES

XI

Transit Number scan scan

D0 scan

None*

$FF

Yes/No

Are you sure?

No Errors (Good Read)

A

No MICR

B

00–7F (00)* 00–7F (01)*

Low Signal

C

00–7F (02)*

Serial # not present

D

00–7F (03)*

Invalid ABA #

E

00–7F (04)*

Parser Error

F

00–7F (05)*

Acct. # Error

G

00–7F (06)*

Canadian Check

H

00–7F (07)*

Mexican Check

I

00–7F (08)*

Bad Data

J

00–7F (09)*

SN Range 1–150

XV

00–7F (10)*

SN Range 151–300

XVI

00–7F (11)*

SN Range 301–500

XVII

00–7F (12)*

Business Check

XVIII

00–7F (13)*

Old U. S.

XIX

00–7F (14)*

Traveler’s Check

XX

00–7F (15)*

DEFAULT

(1) * Designates DEFAULT selections.

scan

EXIT END PROGRAMMING

43