Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 9 of 10

SCANTEAM 5700 Decoded Output User's Guide, pages 81 to 90

Pages 81 to 90 of 98

The original document is the PDF (913 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP ST5700

Page 81

RS–232 5700–X1, 5700–X2 (TTL) and 5700–X3 (True) Decoded output data format is provided at the modular connector in the scanner handle. Interface cables normally supplied with scanner model 5700–X1, 5700–X2 (TTL), and 5700–X3 (True) are terminated with an 10 pin modular plug (P1) and a 9 pin Type D connector (P2) that is compatible with all Welch Allyn terminals. See chart below.

P3 4 Pin Type Mini–DIN P3 connects to the external power supply.

P1

4

3

2

P2 10 Pin Modular Plug P1 connects to the scanner handle.

9 Pin Type D Female

5

Pin 10

1

9

6 View A–A

P1

Signal

Function

2 3 4 5 6 7 8 9

Braid

Cord Shield

DTR

Data Terminal Ready

Ground

Supply Ground

RXD

470Ω

View B–B

P2 connects to your terminal.

Pin 1

Receive Data – Serial Data to Scanner

TXD

Transmit Data – Serial Data from Scanner

+5VDC

5 Volt Power Connection

RTS

Request to Send Data

CTS

470Ω

1

P3

2 1 SH

P2 SH

6 5 3 2

Clear to Send Data

8 7

SCANTEAM 5700 User’s Guide

7–5

Page 82

Laser Output 5700–X1, 5700–X2 (Laser Compatible Bar Image, Low Power/Dual Interface) Conventional laser data format is provided at the modular connector in the scanner handle. Interface cables normally supplied with scanner model 5700–X1 and 5700–X2 are terminated with an 10 pin modular plug (P1) and a 9 pin Type D (Squeeze–to–release) connector (P2) that is compatible with all Welch Allyn terminals. See chart below.

P1

P2

10 Pin Modular Plug

9 Pin Type D Female

P1 connects to the scanner handle.

P2 connects to your terminal.

Pin 1

5

Pin 10

9

1 6 View A–A

P1

Signal

Function

P2

9 6 5 7 2 3 4 8 10 1

SOS

Start of Scan

Data

Digital Bar Code Data Output

Good Read

Turn on Good Read LED or Beeper

+5VDC

5 Volt Power Connection

Trigger

Trigger Signal to Decoder

Enable

Laser Enable

Ground

Supply Ground

N/C

Cord Shield

1 2 3 9 5 6 7 8

7–6

N/C N/C

SCANTEAM 5700 User’s Guide

Braid

Page 83

Section 7

Maintenance and Troubleshooting

Maintenance The Hand-Held Decoded Output Laser Scanner provides reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks insure dependable scanner operation: Cleaning the Scan Window Scanning performance may degrade if the scan window is not clean. If the window is visibly dirty, or if the scanner isn’t scanning well, clean the scan window with a soft cloth or facial tissue dampened with water (or a mild detergent– water solution). If a detergent solution is used, rinse with a clean tissue dampened with water only. The scanner housing may also be cleaned the same way.

!

Warning:

Do not submerge the scanner in water. The scanner’s housing is not water–tight. Do not use abrasive wipers or tissues on the scan window: abrasive wipers may scratch the window. Never use solvents (alcohol or acetone) on the housing or window: solvents may damage the finish or the window. Do not open the scanner. There are no serviceable parts inside.

Inspecting Cords and Connectors Inspect the scanner’s interface cable and connector for wear or other signs of damage. A badly worn cable or damaged connector may interfere with scanner operation. Contact your Welch Allyn distributor for information about cable replacement. Cable replacement instructions on page 8–2.

Examining the Scanner Housing Routinely examine the scanner housing for signs of damage. A damaged housing may cause the internal components to move and may result in a malfunctioning scanner.

SCANTEAM 5700 User’s Guide

8–1

Page 84

Replacing the Interface Cable The standard interface cable is attached to the scanner with an 8–pin modular connector. When properly seated, the connector is held in the scanner handle by a flexible retention tab. The cable’s designed to be field replaceable. Notes: •

Order replacement cables from Welch Allyn or from an authorized distributor. When ordering a replacement cable, specify the cable part number of the original interface cable.

•

To Replace the Interface Cable:

➊ Turn the power to the host system OFF. ➋ Disconnect the scanner cable from the terminal or computer. ➌ Locate the small hole on the side of the scanner handle near the base (see Figure below).

➍ Straighten one end of a paper clip. ➎ Insert the end of the paper clip into the small hole and press in. This depresses the retention tab, releasing the connector. Pull the connector out of the scanner handle while maintaining pressure on the paper clip.

Cable Release

➏ Replace with the new cable. Insert the connector into the opening at the base of the scanner handle. Press firmly. The connector is “keyed” to go in only one way, and will click into place.

To Reset Factory Settings If you aren’t sure what programming options have been set up in your scanner, or you’ve changed some options and now want the factory settings restored, refer to Main Menu Selections in Section 1 and scan the Factory Default Settings bar code.

8–2

SCANTEAM 5700 User’s Guide

Page 85

Troubleshooting The Hand-Held Decoded Output Laser scanner automatically performs self-tests whenever you turn it on. If your scanner is not functioning properly, review the following Troubleshooting Guide to try to isolate the problem.

Troubleshooting Guide Is the power on? Is the red illuminated beam on? If the red scan beam on the scanner isn’t illuminated, check that:

➊ the cable is connected properly. ➋ the host system power is on (if external power isn’t used).

Is the scanner having trouble reading your bar codes? If the scanner isn’t reading bar codes well, check that the bar codes:

➊ aren’t smeared, rough, scratched, or exhibiting voids. ➋ aren’t coated with frost or water droplets on the surface. ➌ are enabled in the scanner or the decoder the scanner is connected to.

Is the bar code displayed but not “entered”? The bar code is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return key or the Tab key, for example). You need to program a suffix. Programming a suffix enables the scanner to output the scanned bar code plus the key you need (such as a “CR,” carriage return) to enter the bar code into your application. (See Suffix Selection in Section 3, Output Parameters Menu.)

SCANTEAM 5700 User’s Guide

8–3

Page 86

Does the scanner read your bar code incorrectly? If the scanner reads a bar code (one beep for a good read), but the bar code is not displayed correctly on the host screen:

➊ The scanner may not be programmed for the appropriate terminal interface. Example: You scan “12345” and the host displays “@es%.” Reprogram the scanner with the correct “Plug and Play” or Terminal Selection bar code (see Section 1).

➋ The scanner may not be programmed to output your bar code properly. Example: You scan “12345” and the host displays “A12345B.” Reprogram the scanner with the proper Symbology selections (see Section 4, Symbology Menu).

The scanner won’t read your bar code at all? If the scanner will not read your bar code:

➊ Try scanning the Sample Bar Codes (found on the back cover of the User’s Guide). If the scanner reads the Sample Bar Codes, check that your bar code is readable. (See “Is the scanner having trouble reading your bar codes” on the previous page.) Verify that your bar code symbology is enabled. (See Sections 4, Symbology Menu.) If the scanner does not read the Sample Bar Codes either, continue to #2, below...

➋ If the scanner won’t read the Sample Bar Codes either: Verify that the bar code symbologies are enabled. (See Sections 4, Symbology Menu.) Scan the “Default All... ” bar code on each symbology menu page in Section 4 to enable most symbologies. (MSI and Plessey will have to be enabled individually, as they are defaulted Off.)

8–4

SCANTEAM 5700 User’s Guide

Page 87

Section 8

Customer Service

Obtaining Factory Service Welch Allyn provides service for all its products through a service center located at its manufacturing facilities in Skaneateles, New York. To obtain warranty or non–warranty service, return the unit to Welch Allyn (postage paid) with a copy of the dated purchase record attached. In the United States, please contact the Welch Allyn Product Service Department at the address/telephone number listed below to obtain a Return Material Authorization number (RMA #). Main Office Welch Allyn, Inc. Data Collection Division 4619 Jordan Road P.O. Box 187 Skaneateles Falls, New York 13153–0187 Product Service Department Telephone: (315) 685–4278 or 685–4360 Fax: (315) 685–4156 For service in Europe, please contact your Welch Allyn representative (at appropriate address below) or your local distributor. European Office Welch Allyn, Ltd. Hondsruglaan 87 D 5628 DB Eindhoven The Netherlands Telephone: Int+ 31 40 242 4486 Fax: Int+ 31 40 2425672 United Kingdom Office Welch Allyn U.K., Ltd. Dallam Court Dallam Lane Warrington Cheshire WA2 7LT United Kingdom Telephone: Int+44–1925–240055 Fax: Int+44–1925–631280 For service in Asia, please contact your Welch Allyn representative (at address below) or your local distributor.

SCANTEAM 5700 User’s Guide

9–1

Page 88

For service in Asia, please contact your Welch Allyn representative (at address below) or your local distributor. Asia / Pacific Office Welch Allyn 10/F Tung Sun Commercial Centre 194–200 Lockhart Road Wanchai, Hong Kong Telephone: Int+852–2511–3050 or 2511–3132 Fax: Int+852–251–1355 For service in Japan, please contact your Welch Allyn representative (at address below) or your local distributor. Japan Office Welch Allyn, Ltd. Bon Marusan 8F 3-5-1 Kanda-Jinbocho Chiyoda-ku Tokyo 101, Japan Telephone: Int+81–3–5212–7392 Fax: Int+81–3–3261–7372 For service in Latin America, please contact your Welch Allyn representative (at address below) or your local distributor. Latin America Office Welch Allyn, Ltd. 5150 North Tamiami Trail Suite 302 Naples, FL 34103-2821 Telephone: (941) 263–7600 Fax: (941) 263–9689

Help Desk If, after reviewing the Troubleshooting Section, you still need assistance installing or troubleshooting your Cordless System, please call your Distributor or the nearest Welch Allyn technical support office. North America: Telephone: (315) 685–2476 (8 a.m. to 6 p.m. EST) Fax number: (315) 685–4960 Email: dcd_techsupt@welchallyn.com Europe: European Office Telephone: Int+31 40 242 4486 United Kingdom Telephone: Int+44 1925 240055 Email: dcd_techsupt@welchallyn.com

Asia: Telephone: Email:

9–2

Int+852–2511–3050 or 2511–3132 dcd_techsupt@welchallyn.com

SCANTEAM 5700 User’s Guide

Page 89

Limited Warranty Welch Allyn, Inc., hereby warrants its products to be functional and free from manufacturing defects at the time of delivery. Welch Allyn, Inc. further warrants that it will replace or repair, at its option, any unit that fails to perform according to Welch Allyn’s published specifications during a period of two (2) years from the time of shipment by Welch Allyn, Inc. to the user at the time it is purchased from any of Welch Allyn Inc.’s Authorized Distributors. Any attempt on the part of the user to disassemble or service the equipment shall void the warranty. The warranty does not apply to product which have been damaged by improper handling, shipping, or misuse. The warranty does not apply, if, in the sole opinion of Welch Allyn, Inc., the unit has been damaged by accident, misuse, neglect, improper shipping and handling. Since the unit is sensitive to static, the responsibility to protect it from static damage is solely that of the user. The warranty is valid only if the unit or scanner has not been tampered with or serviced by any party unauthorized by Welch Allyn, Inc. as a repair facility. THE WARRANTIES SET FORTH HEREIN ARE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE BUYER ACKNOWLEDGES THAT NO OTHER REPRESENTATIONS WERE MADE OR RELIED UPON WITH RESPECT TO THE QUALITY AND FUNCTION OF THE BOARD AND SCANNER HEREIN SOLD. In no event shall Welch Allyn, Inc. or its resellers be liable for any loss, inconvenience or damage whether direct, incidental, consequential or otherwise, and whether caused by negligence or other fault resulting from the breach of any express warranty except as set forth herein. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state or country to country.

SCANTEAM 5700 User’s Guide

9–3

Page 90

9–4

SCANTEAM 5700 User’s Guide