Page 71

Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the Hand-Held Decoded Output Laser scanner. Function Code NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

HEX/ASCII Value 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

Full ASCII “CTRL” + 2 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] 6 -

The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to US only. The following chart indicates the equivalents of these five characters for different countries. Country Codes ] United States 6 [ \ ] Belgium 6 [ < 9 Scandinavia 6 8 < $ France 6 ^ = 8 + Germany 6 Ã + Italy 6 \ .. Swiss 6 < ] United Kingdom 6 [ i 9 Denmark 6 8 \ 9 Norway 6 8 \ ] Spain 6 [ \

SCANTEAM 5700 User’s Guide

6–1

Page 72

Supported Interface Keys Supported Interface Keys

IBM AT/XT and PS/2 Compatibles, IBM XTs and Compatibles WYSE PC/AT

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

Reserved Enter (KP) Cap Lock ALT make ALT break CTRL make CTRL break CR/Enter Reserved Tab Reserved Tab Delete CR/Enter Insert Escape F11 Home Print Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

Reserved CR/Enter Caps Lock Reserved Reserved Reserved Reserved CR/Enter Reserved Tab Reserved Tab Delete CR/Enter Insert Escape Reserved Home Print Back Space Back Tab Reserved F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

IBM, DDC, Memorex Telex, Harris* Reserved Enter F11 F12 F13 F14 F15 New Line F16 F17 F18 Tab/Field Forward Delete Field Exit/New Line Insert F19 Error Reset Home F20 Back Space Backfield/Back Tab F21 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

* IBM 3191/92, 3471/72, 3196/97, 3476/77, DDC 3596, Telex (all models), Harris H180/190 with 122 key keyboards

6–2

SCANTEAM 5700 User’s Guide

Page 73

Supported Interface Keys Supported Interface Keys

IBM, Memorex Telex (102)*

Memorex Telex (88)**

DEC VT, HDS, WYSE***

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

Reserved Enter F11 F12 F13 F14 F15 New Line F16 F17 F18 Tab/Field Forward Delete Field Exit Insert Clear Error Reset Home Print Back Space Back Tab F19 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

Reserved Enter PF10 PF11 PF12 Reserved Reserved New Line Field Forward Field Forward Reserved Field Forward Delete New Line Insert Erase Error Reset Reserved Print Back Space Back Field Reserved PF1 PF2 PF3 PF4 PF5 PF6 PF7 PF8 PF9 Home

Reserved Enter PF1 PF2 PF3 PF11 PF12 New Line PF4 TAB F13 F14 Remove New Line Insert Here Cursor Up Cursor Left Cursor Down Cursor Right Delete Print F15 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

* IBM 3196/97, 3476/77, 3191/92, 3471/72, Memorex Telex (all models) with 102 key keyboards ** Memorex Telex with 88 key keyboards *** DEC VT 220/320/340/420 (only available on SCANTEAM 5700–X3), HDS–3200, WYSE WY–85/185

SCANTEAM 5700 User’s Guide

6–3

Page 74

Supported Interface Keys Esprit 200, 400 Supported Interface Keys ANSI NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

6–4

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab N/A New Line N/A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

Esprit 200, 400 ASCII

Esprit 200, 400 PC

Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab N/A New Line N/A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab Delete New Line Insert Escape F11 Home Print Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

SCANTEAM 5700 User’s Guide

Page 75

Supported Interface Keys Supported Interface Keys

Bull BDS–7 (Honeywell HDS–7)

HP 700/92

WYSE WY–60/150 (ASCII/ANSI keyboards)

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

Reserved Transmit Reserved Reserved Reserved Backtab Reserved Carriage Return Back Space Tab F11 F12 Delete Character Carriage Return Insert Clear Error Reset Home Delete Line Erase EOP Erase EOF Insert Line F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

Reserved Enter Caps Reserved Reserved Reserved Reserved Reserved Back Space Tab Reserved Reserved Reserved Return Reserved Reserved Home Reserved Reserved Reserved Reserved Clear Screen F1 F2 F3 F4 F5 Escape F6 F7 F8 Reserved

Reserved Enter PF1 PF2 PF3 PF11 PF12 New Line PF4 TAB F13 F14 Remove New Line Insert Here Cursor Up Cursor Left Cursor Down Cursor Right Delete Print F15 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

SCANTEAM 5700 User’s Guide

6–5

Page 76

Supported Interface Keys Supported Interface Keys

WYSE WY–30

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

Reserved Enter Reserved Reserved Reserved Reserved Reserved Return Reserved Tab Line Feed Reserved Reserved Return Reserved Cursor Up Cursor Left Cursor Down Cursor Right Back Space Reserved Reserved F1 F2 F3 F4 F5 (CTRL F1) F6 (CTRL F2) F7 (CTRL F3) F8 (CTRL F4) F9 (SHIFT F2) F10 (SHIFT F3)

6–6

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

SCANTEAM 5700 User’s Guide

Page 77

Sectio 7

Product Specifications

SCANTEAM 5700 Product Specifications Parameter

Specification

Dimensions Weight Length Height Width

7 ounces (198 g) 5.8 inches (14.8 cm) 5.8 inches (14.8 cm) 3.0 inches (7.6 cm)

Light Source

670 nm visible laser diode (VLD); 5700ALR = 650nm VLD

Scan Rate

36 ±3 scans per second

Print Contrast

Minimum Reflective Difference = 25% (5700/A); MRD = 40% (5700ALR, 5700/HD)

Skew Angle

±65 degrees (from perpendicular) – 5700/A ±60 degrees (from perpendicular) – 5700/HD, 5700ALR

Pitch Angle

±55 degrees (left/right from perpendicular) – 5700/A ±65 degrees (left/right from perpendicular) – 5700/HD, 5700ALR

Operating Voltage Non-Decoded Decoded

+4.5 to 5.5 VDC (57–04 model only supports +12VDC input with unique cable) Either +5 VDC or +12 VDC, depending on interface

Power Consumption Non-Decoded +5VDC 0.060 mA Idle, 110 mA Scanning; (135mA – 5700ALR) Non-Decoded +12VDC 10 mA Idle, 110 mA Scanning; (145mA – 5700ALR) Decoded +5VDC 60 to 90 mA Idle],, 165 to 200 mA Scanning Decoded +12VDC 105 mA Idle], 210 mA Scanning Temperature Ranges

Operating 32° F to +104° F (–0° C to +40° C) Storage –40° F to +140° F (–40° C to +60° C)

Humidity

5 to 95% non-condensing

Mechanical Shock

5 drops from 5 (5700/A/HD/ALR)

ESD Sensitivity

15 kV to any external surface

Agency Compliance

FCC Class B, CE, LVD, CDRH Class II (Class IIIa for 5700ALR)

feet

(1.5m)

to concrete

] When operated in switched power mode, idle current is less than 0.06 mA.

SCANTEAM 5700 User’s Guide

7–1

Page 78

Laser Output only 5700–X0 (Laser Compatible Bar Image) Conventional laser data format is provided at the modular connector in the scanner handle. Interface cables normally supplied with scanner model 5700–X0 are terminated with an 10 pin modular plug (P1) and a 9 pin Type D (Squeeze–to–release) connector (P2) that is compatible with all Welch Allyn terminals. See chart below.

P1

P2

10 Pin Modular Plug

9 Pin Type D Female

P1 connects to the scanner handle.

P2 connects to your terminal.

Pin 1

5

Pin 10

9

1 6 View A–A

P1

Signal

Function

P2

9 6 5 7 8 3 4 2

SOS

Start of Scan

Data

Digital Bar Code Data Output

Good Read

Turn on Good Read LED or Beeper

+5VDC

5 Volt Power Connection

Trigger

Trigger Signal to Decoder

Enable

Laser Enable

Ground

Supply Ground

Braid

Cord Shield

1 2 3 9 5 6 7 8 4

N/C

♦

♦

♦ Pins 4 and 9 are populated depending on power supply voltage option.

Note: Some decoders may have +12V on pins 4 or 9. Connect to +5VDC ONLY!

7–2

SCANTEAM 5700 User’s Guide

Page 79

Laser Output only 5700–X4 (Laser Compatible Bar Image +12VDC Input*) Conventional laser data format is provided at the modular connector in the scanner handle. Interface cables normally supplied with scanner model 5700–X0 are terminated with an 10 pin modular plug (P1) and a 9 pin Type D (Squeeze–to–release) connector (P2) that is compatible with all Welch Allyn terminals. See chart below.

P1

P2

10 Pin Modular Plug

9 Pin Type D Female

P1 connects to the scanner handle.

P1

Signal

P2 connects to your terminal.

Pin 1

5

Pin 10

9

1 6 View A–A

Function

SOS Start of Scan 9 Good Read Turn on Good Read LED or Beeper 5 Ground Supply Ground 4 Digital Bar Code Data Output Data 6 Trigger Trigger Signal to Decoder 8 Enable Laser Enable 3 +12VDC Power Connection 1 N/C 10 VCC (Connected for AutoTrigger**)

P2

1 3 7 2 5 6 9 8

* Note: Cable supports decoders which supply +12V on pin 9 ONLY. ** Note: Reference the Cable Matrix for correct AutoTrigger cable.

SCANTEAM 5700 User’s Guide

7–3

Page 80

Wand Emulation 5700–X1, 5700–X2 Conventional wand data format is provided at the modular connector in the scanner handle. Interface cables normally supplied with scanner model 5700–X1 and 5700–X2 are terminated with an 10 pin modular plug (P1) and a 9 pin Type D (Squeeze–to–release) connector (P2) that is compatible with all Welch Allyn terminals. See chart below.

P1

P2

10 Pin Modular Plug

9 Pin Type D Female

P1 connects to the scanner handle.

P2 connects to your terminal.

Pin 1

5

Pin 10

9

1 6 View A–A

P1

Signal

Function

P2

2 3 4 6 7

Braid

Cord Shield

8

Prog 1

Tied to 5 Volt Power

Ground

Supply Ground

Barcode

Bar Code Data Output

+5VDC

5 Volt Power Connection

7–4

SCANTEAM 5700 User’s Guide

7 2 4