The text of a manual · part 8 of 10
SCANTEAM 5700 Decoded Output User's Guide, pages 71 to 80
Pages 71 to 80 of 98
The original document is the PDF (913 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST5700
Page 71
Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the Hand-Held Decoded Output Laser scanner. Function Code NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
HEX/ASCII Value 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
Full ASCII “CTRL” + 2 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] 6 -
The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to US only. The following chart indicates the equivalents of these five characters for different countries. Country Codes ] United States 6 [ \ ] Belgium 6 [ < 9 Scandinavia 6 8 < $ France 6 ^ = 8 + Germany 6 Ã + Italy 6 \ .. Swiss 6 < ] United Kingdom 6 [ i 9 Denmark 6 8 \ 9 Norway 6 8 \ ] Spain 6 [ \
SCANTEAM 5700 User’s Guide
6–1
Page 72
Supported Interface Keys Supported Interface Keys
IBM AT/XT and PS/2 Compatibles, IBM XTs and Compatibles WYSE PC/AT
NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
Reserved Enter (KP) Cap Lock ALT make ALT break CTRL make CTRL break CR/Enter Reserved Tab Reserved Tab Delete CR/Enter Insert Escape F11 Home Print Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
Reserved CR/Enter Caps Lock Reserved Reserved Reserved Reserved CR/Enter Reserved Tab Reserved Tab Delete CR/Enter Insert Escape Reserved Home Print Back Space Back Tab Reserved F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
IBM, DDC, Memorex Telex, Harris* Reserved Enter F11 F12 F13 F14 F15 New Line F16 F17 F18 Tab/Field Forward Delete Field Exit/New Line Insert F19 Error Reset Home F20 Back Space Backfield/Back Tab F21 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
* IBM 3191/92, 3471/72, 3196/97, 3476/77, DDC 3596, Telex (all models), Harris H180/190 with 122 key keyboards
6–2
SCANTEAM 5700 User’s Guide
Page 73
Supported Interface Keys Supported Interface Keys
IBM, Memorex Telex (102)*
Memorex Telex (88)**
DEC VT, HDS, WYSE***
NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
Reserved Enter F11 F12 F13 F14 F15 New Line F16 F17 F18 Tab/Field Forward Delete Field Exit Insert Clear Error Reset Home Print Back Space Back Tab F19 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
Reserved Enter PF10 PF11 PF12 Reserved Reserved New Line Field Forward Field Forward Reserved Field Forward Delete New Line Insert Erase Error Reset Reserved Print Back Space Back Field Reserved PF1 PF2 PF3 PF4 PF5 PF6 PF7 PF8 PF9 Home
Reserved Enter PF1 PF2 PF3 PF11 PF12 New Line PF4 TAB F13 F14 Remove New Line Insert Here Cursor Up Cursor Left Cursor Down Cursor Right Delete Print F15 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
* IBM 3196/97, 3476/77, 3191/92, 3471/72, Memorex Telex (all models) with 102 key keyboards ** Memorex Telex with 88 key keyboards *** DEC VT 220/320/340/420 (only available on SCANTEAM 5700–X3), HDS–3200, WYSE WY–85/185
SCANTEAM 5700 User’s Guide
6–3
Page 74
Supported Interface Keys Esprit 200, 400 Supported Interface Keys ANSI NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
6–4
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab N/A New Line N/A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
Esprit 200, 400 ASCII
Esprit 200, 400 PC
Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab N/A New Line N/A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab Delete New Line Insert Escape F11 Home Print Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
SCANTEAM 5700 User’s Guide
Page 75
Supported Interface Keys Supported Interface Keys
Bull BDS–7 (Honeywell HDS–7)
HP 700/92
WYSE WY–60/150 (ASCII/ANSI keyboards)
NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
Reserved Transmit Reserved Reserved Reserved Backtab Reserved Carriage Return Back Space Tab F11 F12 Delete Character Carriage Return Insert Clear Error Reset Home Delete Line Erase EOP Erase EOF Insert Line F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
Reserved Enter Caps Reserved Reserved Reserved Reserved Reserved Back Space Tab Reserved Reserved Reserved Return Reserved Reserved Home Reserved Reserved Reserved Reserved Clear Screen F1 F2 F3 F4 F5 Escape F6 F7 F8 Reserved
Reserved Enter PF1 PF2 PF3 PF11 PF12 New Line PF4 TAB F13 F14 Remove New Line Insert Here Cursor Up Cursor Left Cursor Down Cursor Right Delete Print F15 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
SCANTEAM 5700 User’s Guide
6–5
Page 76
Supported Interface Keys Supported Interface Keys
WYSE WY–30
NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
Reserved Enter Reserved Reserved Reserved Reserved Reserved Return Reserved Tab Line Feed Reserved Reserved Return Reserved Cursor Up Cursor Left Cursor Down Cursor Right Back Space Reserved Reserved F1 F2 F3 F4 F5 (CTRL F1) F6 (CTRL F2) F7 (CTRL F3) F8 (CTRL F4) F9 (SHIFT F2) F10 (SHIFT F3)
6–6
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
SCANTEAM 5700 User’s Guide
Page 77
Sectio 7
Product Specifications
SCANTEAM 5700 Product Specifications Parameter
Specification
Dimensions Weight Length Height Width
7 ounces (198 g) 5.8 inches (14.8 cm) 5.8 inches (14.8 cm) 3.0 inches (7.6 cm)
Light Source
670 nm visible laser diode (VLD); 5700ALR = 650nm VLD
Scan Rate
36 ±3 scans per second
Print Contrast
Minimum Reflective Difference = 25% (5700/A); MRD = 40% (5700ALR, 5700/HD)
Skew Angle
±65 degrees (from perpendicular) – 5700/A ±60 degrees (from perpendicular) – 5700/HD, 5700ALR
Pitch Angle
±55 degrees (left/right from perpendicular) – 5700/A ±65 degrees (left/right from perpendicular) – 5700/HD, 5700ALR
Operating Voltage Non-Decoded Decoded
+4.5 to 5.5 VDC (57–04 model only supports +12VDC input with unique cable) Either +5 VDC or +12 VDC, depending on interface
Power Consumption Non-Decoded +5VDC 0.060 mA Idle, 110 mA Scanning; (135mA – 5700ALR) Non-Decoded +12VDC 10 mA Idle, 110 mA Scanning; (145mA – 5700ALR) Decoded +5VDC 60 to 90 mA Idle],, 165 to 200 mA Scanning Decoded +12VDC 105 mA Idle], 210 mA Scanning Temperature Ranges
Operating 32° F to +104° F (–0° C to +40° C) Storage –40° F to +140° F (–40° C to +60° C)
Humidity
5 to 95% non-condensing
Mechanical Shock
5 drops from 5 (5700/A/HD/ALR)
ESD Sensitivity
15 kV to any external surface
Agency Compliance
FCC Class B, CE, LVD, CDRH Class II (Class IIIa for 5700ALR)
feet
(1.5m)
to concrete
] When operated in switched power mode, idle current is less than 0.06 mA.
SCANTEAM 5700 User’s Guide
7–1
Page 78
Laser Output only 5700–X0 (Laser Compatible Bar Image) Conventional laser data format is provided at the modular connector in the scanner handle. Interface cables normally supplied with scanner model 5700–X0 are terminated with an 10 pin modular plug (P1) and a 9 pin Type D (Squeeze–to–release) connector (P2) that is compatible with all Welch Allyn terminals. See chart below.
P1
P2
10 Pin Modular Plug
9 Pin Type D Female
P1 connects to the scanner handle.
P2 connects to your terminal.
Pin 1
5
Pin 10
9
1 6 View A–A
P1
Signal
Function
P2
9 6 5 7 8 3 4 2
SOS
Start of Scan
Data
Digital Bar Code Data Output
Good Read
Turn on Good Read LED or Beeper
+5VDC
5 Volt Power Connection
Trigger
Trigger Signal to Decoder
Enable
Laser Enable
Ground
Supply Ground
Braid
Cord Shield
1 2 3 9 5 6 7 8 4
N/C
♦
♦
♦ Pins 4 and 9 are populated depending on power supply voltage option.
Note: Some decoders may have +12V on pins 4 or 9. Connect to +5VDC ONLY!
7–2
SCANTEAM 5700 User’s Guide
Page 79
Laser Output only 5700–X4 (Laser Compatible Bar Image +12VDC Input*) Conventional laser data format is provided at the modular connector in the scanner handle. Interface cables normally supplied with scanner model 5700–X0 are terminated with an 10 pin modular plug (P1) and a 9 pin Type D (Squeeze–to–release) connector (P2) that is compatible with all Welch Allyn terminals. See chart below.
P1
P2
10 Pin Modular Plug
9 Pin Type D Female
P1 connects to the scanner handle.
P1
Signal
P2 connects to your terminal.
Pin 1
5
Pin 10
9
1 6 View A–A
Function
SOS Start of Scan 9 Good Read Turn on Good Read LED or Beeper 5 Ground Supply Ground 4 Digital Bar Code Data Output Data 6 Trigger Trigger Signal to Decoder 8 Enable Laser Enable 3 +12VDC Power Connection 1 N/C 10 VCC (Connected for AutoTrigger**)
P2
1 3 7 2 5 6 9 8
* Note: Cable supports decoders which supply +12V on pin 9 ONLY. ** Note: Reference the Cable Matrix for correct AutoTrigger cable.
SCANTEAM 5700 User’s Guide
7–3
Page 80
Wand Emulation 5700–X1, 5700–X2 Conventional wand data format is provided at the modular connector in the scanner handle. Interface cables normally supplied with scanner model 5700–X1 and 5700–X2 are terminated with an 10 pin modular plug (P1) and a 9 pin Type D (Squeeze–to–release) connector (P2) that is compatible with all Welch Allyn terminals. See chart below.
P1
P2
10 Pin Modular Plug
9 Pin Type D Female
P1 connects to the scanner handle.
P2 connects to your terminal.
Pin 1
5
Pin 10
9
1 6 View A–A
P1
Signal
Function
P2
2 3 4 6 7
Braid
Cord Shield
8
Prog 1
Tied to 5 Volt Power
Ground
Supply Ground
Barcode
Bar Code Data Output
+5VDC
5 Volt Power Connection
7–4
SCANTEAM 5700 User’s Guide
7 2 4