The text of a manual · part 10 of 10
SCANTEAM 5700 Decoded Output User's Guide, pages 91 to 98
Pages 91 to 98 of 98
The original document is the PDF (913 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST5700
Page 91
Serial Interface Menu Defaults The following chart lists the factory default Serial Interface Menu settings (indicated by a “✱” on the programming menu pages).
Default Setting
Page Reference
Primary Prefix
None
Page 2–3
Primary Suffix
None
Page 2–3
Secondary Prefix
None
Page 2–5
Secondary Suffix
None
Page 2–5
Beeper Volume
High
Page 2–8
Output Delays Intercharacter Delay
00 (x5mS)
Page 2–8
Interfunction Delay
00 (x5mS)
Page 2–8
Parameter Name Prefix / Suffix Selections
Output Selections
Intermessage Delay
00 (x5mS)
Page 2–8
Reread Delay
Low (175mS)
Page 2–9
Good Read Delay
None
Page 2–9
Laser Voting
Disable
Page 2–9
Buffered Scans
Enable
Page 2–10
Code I.D. Transmit
Disable
Page 2–10
AIM I.D. Transmit
Disable
Page 2–10
Function Code Transmit
Enable
Page 2–10
Serial Communication Selections CTS Check
Disable
Page 2–11
Baud Rate
9600
Page 2–11
RS-232 Word Length
7 Data Bits, 1 Stop Bit
Page 2–12
Parity
Even
Page 2–12
Protocol
Record
Page 2–13
Serial Wedge
To P1
Page 2–13
Disable
Page 2–15
Data Formatter Selections Require Data Format
SCANTEAM 5700 User’s Guide
Page 92
General Operating Menu Defaults The following chart lists the factory default General Operating Menu settings (indicated by a “✱” on the programming menu pages).
Default Setting
Page Reference
Marker Beam (5700ALR only)
Off
Page 3–2
AutoTrigger
Enable
Page 3–2
Transmission Rate
25 ips
Page 3–3
Wake Up Pulse
Disable
Page 3–3
Output Polarity
Black High
Page 3–3
United States
Page 3–4
AT Direct Connect
Disable
Page 3–5
NCR 7052 Keypad
Layout 1 (Telephone)
Page 3–5
Keyboard Style
Prior to Software 2.0–Style A
Parameter Name Laser Options
Wand Emulation Selections
Country Code Selections Foreign Keyboards
Keyboard Selections
Keyboard Style Modifiers
Rev
Page 3–6
Software Rev 2.0–Regular
Page 3–7
Numeric Keypad Mode Off
Page 3–8
SCANTEAM 5700 User’s Guide
Page 93
Symbology Menu Defaults – Industrial The following chart lists the factory default Industrial Symbology Menu settings (indicated by a “✱” on the programming menu pages).
Default Setting
Page Reference
Codabar
On
Page 4–2
Start / Stop Characters
Don’t Transmit
Page 4–2
Decoding
Adaptive
Page 4–2
Message Length
Min = 4, Max = 60
Page 4–2
Check Character
No Check Character
Page 4–3
Concatenation
Allow
Page 4–3
On
Page 4–4
Parameter Name Codabar Selections
Code 39 Selections Code 39 Start / Stop Characters
Don’t Transmit
Page 4–4
Full ASCII Append
Enable Disable
Page 4–4 Page 4–4
Decoding
Adaptive
Page 4–5
Message Length
Min = 0, Max = 48
Page 4–5
Check Character
No Check Character
Page 4–5
Code 93
On
Page 4–6
Message Length
Min = 0, Max = 64
Page 4–6
Interleaved 2 of 5
On
Page 4–7
Decoding
Adaptive
Page 4–7
Message Length
Min = 4, Max = 80
Page 4–7
Check Digit
No Check Digit
Page 4–7
Code 2 of 5
On
Page 4–8
Message Length
Min = 4, Max = 48
Page 4–8
Matrix 2 of 5
On
Page 4–8
Message Length
Min = 4, Max = 80
Page 4–8
Code 93 Selections
Interleaved 2 of 5 Selections
Code 2 of 5 Selections
Matrix 2 of 5 Selections
SCANTEAM 5700 User’s Guide
Page 94
Symbology Menu Defaults – Industrial The following chart lists the factory default Industrial Symbology Menu settings (indicated by a “✱” on the programming menu pages).
Default Setting
Page Reference
Code 11
On
Page 4–9
Check Digits Required
2 Check Digits
Page 4–9
Message Length
Min = 4, Max = 80
Page 4–9
Code 128
On
Page 4–9
Message Length
Min = 0, Max = 80
Page 4–9
Parameter Name Code 11 Selections
Code 128 Selections
Code 128 Function Character Selection Code 128 Function Character
Off
Page 4–10
<GS> Substitution
Off
Page 4–10
Code 16K
Off
Page 4–11
Message Length
Min = 0, Max = 154
Page 4–11
Code 49
Off
Page 4–11
Message Length
Min = 1, Max = 80
Page 4–11
Code 16K Selections [
Code 49 Selections [
[ Not in standard product. Contact your Welch Allyn Sales Coordinator.
SCANTEAM 5700 User’s Guide
Page 95
Symbology Menu Defaults – Retail The following chart lists the factory default Retail Symbology Menu settings (indicated by a “✱” on the programming menu pages).
Default Setting
Page Reference
EAN / JAN 13
On
Page 4–12
EAN / JAN 8
On
Page 4–12
Parameter Name EAN Selections
Check Digit
Transmit
Page 4–12
ISBN
Disable
Page 4–12
On
Page 4–13
UPC Selections UPC A UPC E0
On
Page 4–13
UPC E1
Off
Page 4–13
Check Digit
Transmit
Page 4–13
Number System
Transmit
Page 4–13
Version E Expand
Don’t Expand
Page 4–13
EAN / UPC Addenda Selections EAN / UPC Addenda
Don’t Require
Page 4–14
EAN / UPC Addenda Format
Space
Page 4–14
EAN Addenda Two Digit Addenda
Disable
Page 4–14
Five Digit Addenda
Disable
Page 4–14
UPC Addenda Two Digit Addenda
Disable
Page 4–14
Five Digit Addenda
Disable
Page 4–14
MSI
Off
Page 4–15
Message Length
Min = 4, Max = 48
Page 4–15
Plessey
Off
Page 4–15
Message Length
Min = 4, Max = 48
Page 4–15
MSI Selections
Plessey Selections
SCANTEAM 5700 User’s Guide
Page 96
Default Chart
SCANTEAM 5700 User’s Guide
Page 97
Programming Chart
Hl 0 IA 2 Hl} 4 Hl 6 AM 8 IIA A IMI C VAM E
Mi 1 qi 3 IMI 5 ih 7 Hl 9 ih B HM D Hil F
Page 98
Code 39
Matrix 2 of 5
TEST–SHEET
Code 128
6543210
Code 93
CODE 128
EAN 13
123456–9$
9 780330 290951
Interleaved 2 of 5
1234567890
Code 2 of 5
123456
UPC A with 5 digit addenda 56098
0 12345 67890 5
5700/DO/UG
Rev K
4619 Jordan Road P.O. Box 187 Skaneateles Falls, New York 13153–0187