Page 21

3.3.2

Set–up Procedure This procedure will verify that bar code scanning and communications between the host and the 3700 has been established. To setup serial communications to the scanner 1) Connect the RS–232 communications (I/O) cable between the 3700 and the PC serial port. (You may require a 25 pin to 9 pin converter and Null Modem adapter. Contact your Hand Held Products sales representative or distributor for assistance.) 2) Connect power to the 3700. The scanner should beep once. 3) Start serial communications software program, such as PCTools Desktop (Central Point Software), on the PC. 4) On the PC, set up the serial communications program to match the 3700 default values: • Baud rate = 9600 • Parity = Even • Stop Bits = One • Data Bits = Seven 5) The default factory scanner configuration for the SCANTEAM 3700 requires a serial command from a host to trigger a scan. Change the trigger mode to “Continuous Read, Send Once, Clear on Timeout” by typing <Kg , 1>. The elapsed time between the typing of each character should not exceed 5 seconds. The illumination LEDs should light in response to the command. 6) Confirm communications to the 3700 with the test label below. Observe that the LED reflector is illuminated. Scan the test label“ABC123” below. The default scanner configuration for preamble is Port ID and Code ID. Default postamble is CR (carriage return) and LF (line feed). Observe within 3 seconds the message “1bABC123” on the PC. • “1” = Port ID • “b ” = Code ID (Code 39 code ID is “b”) • “ABC123” = The bar code label

ABC123 This completes set–up of the SCANTEAM 3700 Machine Mount CCD for evaluation. You are now ready to configure the 3700 to explore the functions and features. Instructions for configuring the 3700 using configuration and operational commands are provided in Chapter 4, Configuring the SCANTEAM 3700.

Set–Up and Installation

3–3

Page 22

3.4

Installation in the Host Instrument

Caution:

The 3700 contains static sensitive components. Precautions must be taken to eliminate potential static discharge to the 3700.

Installation in the host instrument includes the following activities: 1) Power down the host system or instrument. 2) Mount the SCANTEAM 3700 in the host instrument. The 3700 has four mounting holes (threaded inserts). Be sure to allow access to all cable connections. Figures 3.2 and 3.3 show the general dimensions for mounting the 3700. 3) Connect the 3700 RS–232 Communication Port to the host system I/O. 4) If applicable, connect your object sensor or hardware triggering device to the 3700. 5) Power up the host system or instrument.

3–4

Set–Up and Installation

Page 23

.375” [9.5]

Focal Plane 1.75” [44.5]

REF 1.95” [49.5]

Top View 2.75” [69.9]

3.5” [88.9]

Mounting Screw Location #6–32 UNC–2B or M3.5 (4 Places)

2.73” [69.3]

2.9” [73.7] .31” [7.9] ✺ Nominal Optics Center Line

1.05” [26.7]

Side View ✺ Installation should provide adjustment to align the optical center line on the intended target. This adjustment should account for tolerance variation in the 3700 scanner, as well as the host equipment.

3.1” [78.7]

.2” [5.1]

Front View

.42” [10.7]

Mounting Surface

Scanner Window millimeters in brackets [mm]

Figure 3.2 Mounting Dimensions for the 3700

Set–Up and Installation

3–5

Page 24

The 3700 Machine Mount CCD may be oriented in any way so that the beam scanning path moves across the bar code as shown in Figure 3.3. Bar code presentation to the scanner is important for successful scanning of the label. The first requirement is that the beam scan path cross all bars on the label, as well a 0.25 inch quiet zone before and after the code. The Automatic Identification Manufacturers (AIM), the industry association, has defined orientation of the bar code label according to Figure 3.4.

Bar Code Target Moving Perpendicular to Scan Beam Optical Light Center Line

Mounting Surface

Optical Light Center Line

Mounting Surface

Bar Code Target Moving Parallel to Scan Beam

Front View Indicates relative direction of bar code target movement

Mounting Surface

Figure 3.3 Examples of SCANTEAM 3700 Barcode Orientation

3–6

Set–Up and Installation

Page 25

PITCH OR ROLL Rotation about the Y–axis ±7°

R

SKEW OR YAW

Bar Code Label

Rotation about the X–axis ±30° (0 to –10° specular reflection interference ✺) ✺ See Figure 3.5

R

Bar Code Label

TILT Rotation about the Z–axis controlled by bar code length and height R

Bar Code Label

Rear View R = Rotation THE ABOVE DEFINITIONS ARE FROM AIM SPECIFICATIONS

Figure 3.4 SCANTEAM 3700 Pitch, Skew and Tilt Tolerance

–30°

Mounting Surface

–10° Bar Code Target

0°

.31” [7.9]

ÇÇÇÇÇÇÇ

Nominal Optics Center Line

SCANTEAM 3700 +30°

Specular Zone (Operation in the Specular Zone must be avoided) Figure 3.5 Specular Reflection Interference

Set–Up and Installation

3–7

Page 26

– NOM – Focal Plane

15°

1.55” [39.4]

27° 2.4” [61]

Top View

3.5” 3.1” [88.9] [78.7] clearance required for = Minimum scanner illumination of target. [

= Receive path/area. [ .61” [15.5] .2” [5.1]

2°

Side View 2°

[ Illumination area is larger than receive area.

millimeters in brackets [mm]

Figure 3.6 Scanner Illumination Clearance This completes installation of the SCANTEAM 3700 Machine Mount CCD in a host instrument. You are now ready to configure the 3700 for your particular application. Instructions for configuring the 3700 using configuration and operational commands are provided in Chapter 4, Configuring the SCANTEAM 3700.

3–8

Set–Up and Installation

Page 27

CONFIGURING THE SCANTEAM 3700

4.1

4

Preparation This chapter provides instructions for configuring the software in the SCANTEAM 3700 Machine Mount CCD. The configuration process allows you to change the operating parameters of the scanner software to explore the functions of the 3700. The user–defined configuration is stored in volatile RAM memory and can be changed by the user. All communication between the host system and the 3700 Machine Mount CCD is through the RS–232 communications interface using an Asynchronous ASCII protocol. The host system sends commands one at a time to the 3700. During the configuration process, there is no acknowledgement or other response from the 3700. It is important to enter commands accurately. If a command is sent erroneously to the 3700, you may terminate that command and send the command again. You may send configuration status query commands to obtain a status listing of the configuration selections. For detailed instructions on preparing the SCANTEAM 3700 for configuration, refer to section 3.3, Set–up Procedure for Use in the Design Lab, or section 3.4, Installation in the Host Instrument. The application–specific features that can be modified using the RS–232 communication line include the following: • Auditory feedback for operator • Bar code symbology may be disabled for security reasons • Communications parameters • Data message options • Decoding enabled or disabled • Fully configurable bar code symbologies and their options • Triggering options.

Configuring the SCANTEAM 3700

4–1

Page 28

4.2

Command Conventions The following conventions apply when entering configuration commands: • Actual serial configuration command entries are highlighted in bold to distinguish them from descriptive text. • Spaces shown within command strings must not be included in the actual string; they are for clarity only. • Commas shown in command strings are used as item separators and are required as place holders; except for trailing commas in abbreviated strings, which are not required. • Where a selection in a command string is indicated to be more than one character (for example, the time value in the Read Timeout command) commas are never used to separate the characters within that item. Command Format The command format contains the following, with the exception of two commands ✺: • < data string > The data string is the serial command. Send the hexadecimal equivalent of each ASCII value when programming the 3700 from the host. An ASCII conversion chart is provided in Appendix D. The following three sections, 4.3, 4.4 and 4.5, explain the operational, configuration and configuration status query commands, providing the ASCII and equivalent hex characters for command definitions. Note:

In order to provide compatibility with drivers already written for the SCANTEAM 7300, configuration commands that deal with multiple scanner ports in the SCANTEAM 7300 are also recognized by the SCANTEAM 3700 Machine Mount CCD. These commands may contain port–specific data not relevant to the 3700. This extra data will be accepted, but ignored. These items are identified in the command descriptions by a pound sign (#).

✺

4–2

The two commands, DC2 and DC4 for enabling and disabling decoding, do not follow the above command format. They are single character commands which do not need the “<” before or the “>” after the data byte.

Configuring the SCANTEAM 3700

Page 29

4.3

Operational Commands Five operational commands recognized by the SCANTEAM 3700 are: <A> – resets the 3700 DC4 – disables bar code scanning DC2 – enables bar code scanning <1> – serial trigger <Z> – saves current configuration in non–volatile memory. Explanations, ASCII and hex characters for the operational commands follow. Reset Command <A> COMMAND

ASCII

Hex Characters

Reset

<A>

3C 41 3E

Sending the operational command <A> causes the 3700 to reset. After reset the 3700 will operate according to the last configuration saved in non–volatile memory. If a valid configuration cannot be retrieved from memory, the 3700 will operate according to the default configuration. Disable Decoding Command DC4 COMMAND

ASCII

Hex Characters

Disable Decoding

DC4

14

This is a single character command. Sending the operational command DC4 will cause the 3700 to stop looking at bar code data. Enable Decoding Command DC2 COMMAND

ASCII

Hex Characters

Enable Decoding

DC2

12

This is a single character command. Sending the operational command DC2 will allow the 3700 to decode according to its current configuration. Note:

DC4 and DC2 are ASCII control characters. With a terminal emulation program running on a PC, send a DC4 by holding down the CTRL key while pressing the “T” key. Send a DC2 by holding down the CTRL key while pressing the “R” key.

Configuring the SCANTEAM 3700

4–3

Page 30

Serial Trigger Command <1> COMMAND

ASCII

Hex Characters

Serial Trigger

<1>

3C 31 3E

Sending the operational command <1> sends a serial trigger to scanner port “1.” If the Trigger Mode for Port “1” is set to allow serial triggers, the 3700 enables the Machine Mount CCD and attempts to read a bar code. Trigger Mode, a configuration command, is described in section 4.4. Serial Trigger Command <2> COMMAND

ASCII

Hex Characters

Serial Trigger

<2>

3C 32 3E

Sending the operational command <2> sends a serial trigger to scanner port “2.” If the Trigger Mode for Port “2” is set to allow serial triggers, the 3700 enables the auxilliary wand input port. The hardware configuration to support this port is optional. Save Configuration Command <Z> COMMAND

ASCII

Hex Characters

Save Configuration

<Z>

3C 5A 3E

Sending the operational command <Z> causes the current configuration to be saved in non–volatile memory.

4–4