Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 8

SCANTEAM 3700 CCD Technical Manual, pages 11 to 20

Pages 11 to 20 of 76

The original document is the PDF (454 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP ST3700

Page 11

SCANTEAM 3700 DESCRIPTION

1.1

1

Introduction The Hand Held Products SCANTEAM 3700 is a fixed mount CCD bar code scanner with integral decoder for easy integration into host equipment. Typical host equipment with bar code requirements satisfied by the 3700 include automated clinical chemistry analyzers, pharmaceutical label verification systems, industrial automation equipment, robotic systems, materials handling equipment, library systems, point of sale terminals and office equipment. The 3700 features Hand Held Products’ time–proven decoding algorithms in a microprocessor–controlled bar code scanner/decoder and offers configurable operating parameters, providing you with the capability to tailor the 3700 to your present requirements and the flexibility to meet your future application requirements. The following features are available with every SCANTEAM 3700: • Economical, reliable, safe CCD scanning technology • Audible indicator configurable for good read or no read • True RS–232 data communications with RTS/CTS, XON/XOFF, ACK/NAK • Autodiscrimination of 6 bar code symbologies • 100 scans per second (standard); other scan rates available • Flexible scan trigger configurations • Decoder configurable for high security • Scan voting to ensure bar code data integrity • Automatic read timeout • Ease of configuration through RS–232 interface

1.2

SCANTEAM 3700 Hardware Description The SCANTEAM 3700 housing is molded ABS formed to enclose the optics platform and electronics. Standard housing width is 3.5 inches (88.9mm). The housing length is 2.9 inches (73.7mm) and the height is fixed at 1.05 inches (26.7mm). The scanner uses red (660 nm wavelength) LED’s to illuminate the bar code label. A high resolution CCD (charge coupled device) is used as an image or reading sensor. A trigger signal can direct the 3700 to read the bar code. The trigger signal may originate from the scanner itself, from a host serial communications program, or from a hardware object sensor. The scanned code is converted to a digital signal in the scanner, then decoded and sent to the host computer or system. Scan width and focal point of the optics may be customized to the particular requirements of your application.

SCANTEAM 3700 Description

1–1

Page 12

Communication is achieved using full duplex, asynchronous serial ASCII through a bidirectional RS–232 connection to the host system. The host defines or sets the configurable features and controls the operation of the 3700. The 3700’s configuration may be stored in non–volatile memory.

1.3

Note:

In this manual, the term “host” refers to any computer that communicates with the SCANTEAM 3700 through its RS–232 port. During the configuration procedure, the host can be the main computer which controls the entire application, or can be a PC which has been connected to the 3700 for just that purpose. The terms “host instrument,” “host equipment,” and “host device” all refer to the system in which the 3700 has been integrated and which communicates with, controls and configures the operating features.

1.2.1

Interface Port The SCANTEAM 3700 has one port for I/O and Power. The port is a 10 pin RJ11 modular female connector. Hardwire connection to the scanner motherboard is available for additional features Pin assignments and function descriptions are presented in Appendix B. Cables are available from Hand Held Products for evaluation of the 3700. Hand Held Products can provide custom cables for host integration. A modular connector was chosen as the standard configuration for ease in servicing the scanner once installed..

1.2.2

Nonvolatile Memory The 3700 contains nonvolatile FLASH memory which is used to store operating parameters configured by means of host serial commands. This memory is easily reconfigurable to modify or add symbologies, as well as to modify or add serial commands to emulate a currently installed scanner.

SCANTEAM 3700 Software Description SCANTEAM 3700 software employs Hand Held Products’ time–proven decoding algorithms, controls the microprocessor functions, selects the scanner ports, decodes the bar codes, and formats the serial output messages. The 3700 standard default parameters can be easily reconfigured to meet most scanning requirements. Application–specific features and options are configurable through the RS–232 communications link to the host system. The 3700 can be configured to autodiscriminate among the following bar code symbologies and their variations: Codabar, Code 39, Code 128, Interleaved 2 of 5, UPC and EAN. Most common bar code options, such as validating symbol length and optional check character, are supported and easily selected. Symbologies can be added from Hand Held Products’ library of decoding algorithms. In addition to decoding selections; data output formats, such as preamble and postamble strings, and operating parameters are also configurable through the host RS–232 serial communications connection.

1–2

SCANTEAM 3700 Description

Page 13

2

SYSTEM HARDWARE DESCRIPTION

2.1

Introduction The major components of the system are the SCANTEAM 3700 Machine Mount CCD and the host instrument or equipment. Electrical power is generally supplied to the 3700 Machine Mount CCD by the host system. Figure 2.1 shows the functional relationships between the components of the basic system.

SCANTEAM 3700 Machine Mount CCD

Host System Asynchronous Communication

Auxiliary Trigger Device (Optional)

Power Supply

Bar Code

Scanning Circuitry ✺

Host Application

Provides Data Input

Scans Bar Code

Supplies Power to 3700 (typically) Sends Configuration Commands

Aux Trigger

Decoder

Triggers Decoder

Enables Scanning Circuitry

Sends Operational Commands

Reads Bar Code

Sends Configuration Status Query Commands

Sends Decoded Bar Code to Host

Sends Software Trigger Signal (Optional)

✺ Scanning circuitry is internal to 3700.

Figure 2.1 Basic System Operation

System Hardware Description

2–1

Page 14

2.2

General Characteristics of the 3700 2.2.1

Mechanical Layout of the 3700 Figure 2.2 shows several views of the SCANTEAM 3700 Machine Mount CCD, including general dimensions, the location of connectors, and the scanner window.

3.5” [88.9]

Top View

2.9” [73.7]

Side View 1.05” [26.7]

Mounting Surface

Back View Interface Port (I/O Communications and Power)

Mounting Surface

Front View millimeters in brackets [mm]

Scanner Window

Figure 2.2 3700 Fixed Mount CCD Dimensions 2–2

System Hardware Description

Page 15

2.3

2.2.2

Single Modular Input / Output / Power Port The interface port is an 8–pin female modular connector used for attaching the Asynchronous Serial Communications Interface Cable. Allows triggering capability (at pin 2) for an external triggering device, such as an object sensor or a switch. Power and ground connections are also on this port.

2.2.3

Audible Indicator The beeper can be disabled by using a configuration command. Refer to Chapter 4 for information on setting configuration commands. The beeper also sounds on power–up or reconfiguration as an audible self–check of software configuration.

2.2.4

Mounting Inserts Inserts are molded into the housing to retain mounting screws. Inserts are available for metric (3.5) or SAE (#6–32) screws.

Operating Theory Figure 2.3 presents a block diagram of the basic SCANTEAM 3700 Machine Mount CCD operation. The SCANTEAM 3700 Machine Mount CCD looks for data input from the scanning circuitry, which includes the LED reflector (illuminates the bar code target), the CCD sensor and imaging lens (focuses the scattered optical energy from the bar code symbol), and the peak detectors and comparator (generates a digital representation of the bar code symbol to send to the microprocessor). Refer to Appendix A, CCD Operation and Bar Code Scanning, for a detailed explanation of 3700 scanning circuitry operation. When the 3700 sees a trigger, a read cycle is started. The read cycle is completed when a bar code is read or the read timeout expires.

LED Reflector

LED Pulse Generator

CCD Sensor

Peak Detectors and Comparator

Auxiliary Trigger (Optional)

Second Scanner Digital Input (Optional)

Decode

RS–232 Communications

Figure 2.3 Basic Scanner/Decoder Operation Note:

A trigger can be a hardware trigger, such as an object sensor, or a software command, such as a serial trigger command or continuous read trigger mode command, from the host. Refer to chapter 4 for description of serial trigger and trigger mode commands..

During a read cycle, the 3700 evaluates scanner data for a valid bar code symbol. If a valid bar code symbol is seen, data is placed into the output queue where it may be transmitted to the host through the RS–232 communications port. The 3700 can optionally be configured to send a “No Read” message when a read cycle times out.

System Hardware Description

2–3

Page 16

2.4

Scanner/Host Communication The RS–232 communications interface of the 3700 is used for entering configuration commands from a PC or host instrument for specific application requirements. The communications I/O port also sends decoded bar code data to the host. 2.4.1

Communications Port The communications port connector for the 3700 is an 8–pin female modular socket for interfacing to the host system or other communications device. Communications between the host system and the 3700 occur using an Asynchronous ASCII protocol. Refer to Appendix B for a complete description of pin assignments of the RS–232 communications port.

Caution:

Do not use a host communications cable with more wires connected than are required for the application. Damage to equipment within the system may result if the communications connection is improperly wired.

2.4.2

Asynchronous Serial ASCII Interface The Asynchronous serial ASCII Interface operates in Full Duplex Mode. Software configuration parameters (see Chapter 4) control Baud Rate, Parity, Data Bits, Stop Bits, Xon/Xoff, ACK/NAK, RTS/CTS, and Pre/Postambles. Baud rate is a means of expressing data transmission speed, where “baud” equals the number of signal events per second (roughly equivalent to bits per second). Parity is a means of checking character bit patterns for validity by confirming if they contain an Even or Odd number of “1”s. The communications port can be configured to operate at baud rates of 600, 1200, 2400, 4800, 9600, 19200, and 38400, with even, odd, or no parity. Data bits refers to the number of bits used to encode each ASCII character in a data message. Stop bits refers to the number of stop bits appended to each character. The communications port can be configured to send 7 or 8 data bits, with 1 or 2 stop bits.

Note:

For proper operation the 3700 must be configured for the same baud rate, parity, number of data bits, and number of stop bits as the connected RS–232 host device.

Xon/Xoff are control characters that refer to ASCII characters “DC1” and “DC3,” respectively. If enabled, Xon/Xoff is a method to control data flow in the following manner. Whenever its buffers approaches full, the device receiving communications data sends an “Xoff” to stop data transmission. The transmitting device stops data transmission. When its buffer approaches empty, the receiving device sends “Xon” and the transmitting device starts sending data again. The receiving device refers to the host instrument. Likewise, the transmitting device refers to the 3700. Note:

2–4

The SCANTEAM 3700 will respond to XON and XOFF characters from the host, but will not send these characters.

System Hardware Description

Page 17

ACK/NAK are ASCII characters that allow the receiving device to tell the sending device to repeat a data message that contains errors. If enabled, the 3700 expects to receive an ACK (positive acknowledgement of data transmission) or a NAK (negative acknowledgement of data transmission) from the host after each message is sent. If a NAK is received, the 3700 repeats the message. After three attempts to transmit have been made, with successive NAK from the host, the 3700 will discard the message. The 3700 responds to communication from the host with an ACK or NAK. Pins are available at the I/O Port to support RTS/CTS handshaking. The RTS/CTS feature may be enabled or disabled in the scanner software configuration. During communications, the 3700 will raise RTS and wait for CTS before each transmission. In applications where the host system does not support “handshaking,” the CTS line may be left unconnected and the 3700 will pull it to the active state. Alternately, if CTS is left unconnected, RTS/CTS can be disabled by configuration command. Preambles and postambles are optional ASCII strings that precede and are appended to each data message sent by the 3700. Typical preamble and postamble strings would include the ASCII control characters STX (start of text), ETX (end of text), CR (carriage return) and LF (line feed). An identification character to indicate the type of bar code read and source scanner port is included in the standard scanner software configuration. 2.4.3

Hardwire Pinouts The following signals not related to communications are available by hardwiring to the motherboard (factory ordered with all cable requirements). See Appendix B for the full lising of available pinouts. • Pin 1 Boot Strap • Pin 2 Dig In – Auxiliary • Pin 3 Reset • Pin 4 IND – Good Read Auxiliary Trigger The scanned data input can be controlled by an external triggering device connected to the Trigger/Enable line (pin 2 of the Communications port). The actual trigger can be as simple as a foot actuated relay switch and as sophisticated as an optical sensor. The Trigger/Enable line action depends on output mode, as follows: • Bar/Space Output Mode – continuous scan while active • ASCII Output Mode – read while active – transmit on timeout.

System Hardware Description

2–5

Page 18

2.5

Power Requirements DC operating voltage is +5 volts and consumes approximately 200 milliamps when scanning. Refer to Appendix B for a complete description of voltage range, current consumption levels, and pin assignments.

2–6

System Hardware Description

Page 19

3

SET–UP AND INSTALLATION

3.1

Introduction This chapter explains the SCANTEAM 3700 Machine Mount CCD set–up for use in the design lab and a brief description of installation in a host instrument. The set–up procedures are intended for a technician or design engineer to explore the functions and features of the 3700 Machine Mount CCD in a hands–on setting, before the 3700 is embedded in host equipment. The section on installation in a host instrument includes the general mounting dimensions of the 3700. Set–up and installation includes unpacking the unit, checking for possible damage during shipment, and connecting the Machine Mount CCD to the host system. The host system in the design lab will typically be a PC/DOS microcomputer with an RS–232 communications port and a serial communications program. Otherwise, the host system is the instrument or equipment the 3700 is intended to be embedded in. A Hand Held Products representative will provide application support if needed. Refer to Chapter 5 for Hand Held Products’ service and technical assistance phone number(s).

3.2

General Preparation for Use Upon receipt, open the carton. Keep the shipping carton since this should be used in the event the scanner ever needs to be returned to the factory for service or repair. Check the part numbers and confirm that each item on the packing list has been supplied. Check that the scanner model number and any other companion products are the ones ordered for your application. The scanner model and serial numbers are on the identification label attached to the scanner enclosure. Refer to Figure 3.1. You may want to record these numbers for easy reference when communicating with Hand Held Products or your Sales Representative. Thoroughly inspect the 3700 to determine if any damage has occurred during shipment. Any damage should be reported immediately to the carrier that delivered the 3700. Damage claims due to handling during shipping should be placed directly with the carrier. Hand Held Products will quote for repair of shipment damage (refer to Chapter 5), but the final claim and negotiations with the carrier are the responsibility of the purchaser. When all the components of your order have been identified and checked, prepare the 3700 for service using the procedures provided in the following sections (for set–up in a design lab or for installation in host equipment). To assure proper operation and prevent possible damage to the 3700 or your host system, perform the following set–up procedures in the sequence in which they are presented. Note:

Before starting the set–up or installation procedure, set the host system or computer power switch to the “OFF” position. Set–Up and Installation

3–1

Page 20

Enlarged View of Label

ST3700 NEAR CONTACT DECODED OUTPUT ITEM# 3700-XYZ SOFTWARE# 31203795-XYZ DATE - S/N H-04-1234 www.welchallyn.com

MADE IN USA

PATENT 5,294,783

Figure 3.1 SCANTEAM 3700 Identification Label

3.3

Set–up Procedure for Evaluation of the 3700

Caution:

3.3.1

The 3700 contains static sensitive components. The 3700 has been designed for internal protection against damage due to discharge. Precautions should be taken to protect against static discharge to the 3700.

Preparation Interface cables for evaluating the 3700 are available from Hand Held Products. Hand Held Products also offers 110VAC and 220VAC to 5VDC power supplies for the 3700. If you wish to construct your own cables, Appendix B lists the 3700 port pin assignments. Set–up Checklist • SCANTEAM 3700 CCD Scanner • SCANTEAM 3700 Input/Output/Power Cable • 5 VDC Power Supply • Computer with Serial I/O Port • For I/O: may need a 25 pin to 9 pin convertor (Refers to step 4 in 3.3.2 Set–up Procedure.) • For I/O: may need a Null Modem adapter (Refers to step 4 in 3.3.2 Set–up Procedure.) • Terminal Emulation Software (Refers to step 6 in 3.3.2 Set–up Procedure.)

3–2

Set–Up and Installation