Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 12

Cordless System Manual: SCANTEAM 2070 Base, SCANTEAM 3470 CCD, SCANTEAM 5770 Laser, pages 51 to 60

Pages 51 to 60 of 112

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP ST3470

Page 51

Section 4

Application Work Groups Menu

Introduction Use this section to program parameters for application work groups for the Cordless System. This programming section contains the following menu selections: • Output Selections (User Feedback) • Prefix and Suffix • Data Formatter When you set up and connect the Cordless System to your host system, you associate the Cordless Scanner to its Base unit. If you are using more than one Cordless Scanner, you may also set up application work groups. (Instructions for associating more scanners – up to nine – to the Base are on page 1–7.) Application work groups may be set up in different configurations using the programming selections found in this section of the manual. For example, one group may need the beeper turned off, will only scan Code 39 bar codes, and needs a carriage return suffix added to the data being sent to the host system via the Base. Another group may require that scanner voting be turned on, will scan UPC A, and needs a space added to the transmitted data, between the main UPC bar code data and the five digit addenda. The Application Work Groups Selection (on the next page) sets up the application work group(s). After you’ve scanned the association bar code on the Base, scan one of the work group numbers to assign the Cordless Scanner to a specific group. You may then program whatever parameters your application requires from the Output (User Feedback), Prefix and Suffix, and Data Formatter Selections menu pages. To add a new Cordless Scanner to an established group, associate the scanner to the Base and scan the application work group number. The scanner will operate and send data to the host system according to that group’s programmed selections. Any programming selections you change or make with one Cordless Scanner will affect all the scanners in a work group.

Note: To program a group’s parameters, you must first scan the group number and then the programming selections (prefix, suffix, data formatter, etc.). The parameters can’t be programmed first and then “made” a group by scanning an application work group number. To remove a scanner associated with a Base unit, use the Remove Scanner Selection on page 4–3. For instance, if nine scanners are associated with a Base (the maximum number) and you want to add a new scanner, you will need to remove one scanner from the established work groups. After removing one scanner by using the Remove Scanner programming bar code, add the new scanner by scanning the association bar code on the Base unit.

Cordless System Manual

4–1

Page 52

Application Work Group Selection This programming selection sets up application work groups sharing specific programming settings (such as Beeper Volume, Scanner Voting, Prefix / Suffix, and Data Formatter). Scan the group number and then program the selections your application requires. (Refer to the introduction, page 4–1, for more information on application work groups.)

✱ Group 0 Group 1

Group 2 Group 3

Group 4 Group 5

Group 6 Group 7

Group 8

4–2

Cordless System Manual

Page 53

Remove Scanner Selection This programming selection removes a scanner from an associated Base unit.

Remove Scanner

Beeper Volume Selection

Low

Off

✱ High

Medium

Decode Beep Selection Note: Decode Beep mode is active only when the programming selections Host ACK(page 3–5) or Require Data Format (page 4–11) are turned on. When Host Ack Selection is on, the scanner will only beep/blink in response to the Escape commands generated by the host. Should you also want the scanner to beep when a bar code has been successfully read and sent to the host from the base, turn on the Decode Beep Selection. When Data Format Required is on, the scanner will only beep if the input data conforms to the edited format or triple beep if it does not meet the format requirements. Should you also want the scanner to beep when a bar code has been successfully read and sent to the host from the base, turn on the Decode Beep Selection.

✱ Off

On

Cordless System Manual

4–3

Page 54

Scanner Voting Selection When Scanner Voting is turned on, the Cordless System requires three (3) identical, consecutive scans before the bar code data will be accepted and transmitted to the terminal. When this selection is turned off, the bar code data will be transmitted following one (1) valid scan.

✱ Off

On

Laser Marker Beam When this selection is turned on (short or long duration), the Cordless Scanner shows a marker or locator beam before the red scan line opens across a bar code and the scanning process begins. The marker beam, emitted by centering the optical scan mirror, appears as a bright spot of illumination that serves as an aiming guide when bar code targets are at a distance from the scanner.

Note: Applies only to the 5770LR product. If this selection is turned on in non-5770LR products, the scan rate is diminished.

✱ Off

Short Duration (.5 seconds)

Long Duration (1.2 seconds)

4–4

Cordless System Manual

Page 55

AIM I.D. Transmit Selection This selection allows you to turn on or turn off the transmission of an AIM I.D. before the decoded bar code symbology. (The Symbology Chart below shows the single AIM[ character code that identifies each symbology. For more information, see AIM Guidelines on Symbology Identifiers.)

✱ Off

On

[ Automatic Identification Manufacturers Inc., a trade association, located at 634 Alpha Drive, Pittsburg, PA 15238–2802.

Welch Allyn Code I.D. Transmit Selection This selection allows you to turn on or turn off the transmission of a Welch Allyn Code I.D. before the decoded bar code symbology. (See the Symbology Chart below for the single character code that identifies each symbology.)

✱ Off

On

Symbology Chart Symbology

AIM ID

Code ID

Symbology

AIM ID

Codabar

]F0 a

Code 2 of 5

]S0 f

Code 39

]A0 b

Code 11

]H0 h

UPC

]E0 c

Code 93

]G0 i

EAN Interleaved 2 of 5

]E0 ]I0 d e

Code 128 Matrix 2 of 5

]C0 ]X0 j m

Cordless System Manual

Code ID

4–5

Page 56

Prefix and Suffix The Cordless System transmits a decoded message after every successful bar code read. Prefix and Suffix characters are data characters you may assign to be sent before and after the transmitted bar code data. Transmitted data frame –>

Prefix

Bar Code Message

Suffix

Characters for the Prefix and Suffix are selected by their hexadecimal ASCII value, up to 12 characters each. Prefix and Suffix characters may be sent for a specific symbology, or may be sent with all bar code scans. Default Prefix = none. Default Suffix = Carriage Return (CR: 0D). Programming Steps to Add a Prefix / Suffix: ➊

To add a Prefix, scan the Add Prefix programming bar code. To add a Suffix, scan the Add Suffix programming bar code.

➋

Refer to the Symbology Chart (page 4–9) to find the Hex value that represents the symbology(s) you want transmitted with one or more Prefixes or Suffixes. Scan the two digits on the Programming Chart (on the inside of the back cover of this manual).

➌

Refer to the Hex ASCII Chart (page 4–9) to find the Hex value that represents the ASCII characters you wish to transmit with the bar code data. Use the Programming Chart (inside back cover) to scan the alphanumeric combination that represents the ASCII characters.

➍

To complete Prefix / Suffix programming, scan either: H Save Current Changes programming bar code. This exits, saving the Prefix / Suffix selections you just assigned. H Discard Current Changes programming bar code. This exits without changing the Prefix / Suffix.

Programming Steps to Clear (or Delete) One or All Prefix / Suffix Entry: ➊

➋

➌

To clear all the Prefix entries for a specific symbology, scan the Clear One Prefix programming bar code. To clear all the Suffix entries for a specific symbology, scan the Clear One Suffix programming bar code. Refer to the Symbology Chart to find the Hex value representing the symbology’s entry you want cleared. Scan the two digits on the Programming Chart (on the inside of the back cover of this menu). Scan Save Current Changes or Discard Current Changes programming bar codes to complete programming.

Other Programming Selections: Scanning the Default Prefix or Default Suffix bar code sets the default Prefix or Suffix (shown above). Other Programming Selections: Scanning the Clear All Prefixes or Clear All Suffixes bar code deletes all Prefix or Suffix selections.

Note: Prefix / Suffix programming examples may be found on page 4–8.

4–6

Cordless System Manual

Page 57

Prefix Selection

Add Prefix ]

Default Prefix (none)

Clear One Prefix ]

Clear All Prefixes

Suffix Selection

Add Suffix ]

Default Suffix (CR)

Clear One Suffix ]

Clear All Suffixes

Exit Selection for Prefix / Suffix

Save Current Changes

Discard Current Changes

] One or more two-digit numbers and Save are required after scanning this programming bar code. Refer to the Programming Chart (inside back cover).

Cordless System Manual

4–7

Page 58

Prefix and Suffix Examples Example 1: Add Suffix for Specific Symbology To send a CR (carriage return) Suffix for UPC only. H Scan the Add Suffix Suffix Selection bar code. H The Symbology Chart indicates that the Hex value of UPC is “63”. Scan 6 and 3 on the Programming Chart (inside back cover). H A “CR” is equivalent to “0D” (see the Hex ASCII Chart). Scan 0 and D on the Programming Chart. H Scan the Save Current Changes Exit Selection bar code.

Example 2: Add Suffix for ALL Symbologies To send a CR (carriage return) Suffix for all symbologies. H Scan the Add Suffix Suffix Selection bar code. H The Symbology Chart indicates that the Hex value for All Symbologies is “99”. Scan 9 and 9 on the Programming Chart. H A “CR” is equivalent to “0D”. Scan 0 and D on the Programming Chart. H Scan the Save Current Changes Exit Selection bar code.

Example 3: Add Prefix for Specific Symbology / Suffix for ALL Symbologies To send an HT (tab) Prefix for UPC only and a CR / LF (carriage return / line feed) Suffix for all symbologies. H Scan the Add Prefix Prefix Selection bar code. H The Symbology Chart indicates that the Hex value of UPC is “63”. Scan 6 and 3 on the Programming Chart. H An “HT” is equivalent to “09”. Scan 0 and 9 on the Programming Chart. H Scan the Add Suffix Suffix Selection bar code. H The Symbology Chart indicates that the Hex value for All Symbologies is “99”. Scan 9 and 9 on the Programming Chart. H A “CR” is equivalent to “0D” and an “LF” is “0A”. Scan 0, D, 0, and A on the Programming Chart. H Scan the Save Current Changes Exit Selection bar code.

Example 4: To Clear a Specific Prefix Entry The Cordless System is programmed to send a CR / LF (carriage return / line feed) Prefix for all symbologies (Hex value, 99). This is one Prefix entry. You’ve also programmed a “#” Prefix for UPC (Hex, 63). To clear the UPC entry, but not the Prefix entry for all symbologies. H Scan the Clear Specific Prefix Prefix Selection bar code. H The Symbology Chart indicates that the Hex value for UPC is “63”. Scan 6 and 3 on the Programming Chart. H Scan the Save Current Changes Exit Selection bar code.

4–8

Cordless System Manual

Page 59

Symbology Chart Symbology

AIM Code Hex Symbology ID ID Value

Codabar

]F0 a

61

Code 11

]H0 h

68

Code 39

]A0 b

62

Code 93

]G0 i

69

UPC

]E0 c

63

Code 128

]C0 j

6A

EAN Interleaved 2 of 5

]E0 ]I0 d e

64 65

Matrix 2 of 5 ]X0 All Symbologies m

6D 99

Code 2 of 5

]S0 f

66

(Prefix/Suffix Programming only.)

AIM ID

Code Hex Value ID

Hex to ASCII Conversion Chart ASCII

Hex

ASCII

Hex

ASCII Hex ASCII Hex ASCII Hex ASCII Hex ASCII Hex ASCII

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F

DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

SP 20 ! 21 ” 22 # 23 $ 24 % 25 & 26 ’ 27 ( 28 ) 29 * 2A + 2B , 2C – 2D . 2E / 2F

0 1 2 3 4 5 6 7 8 9 : ; < = > ?

30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F

@ 40 A 41 B 42 C 43 D 44 E 45 F 46 G 47 H 48 I 49 J 4A K 4B L 4C M 4D N 4E O 4F

P 50 Q 51 R 52 S 53 T 54 U 55 V 56 W 57 X 58 Y 59 Z 5A [ 5B \ 5C ] 5D ^ 5E _ 5F

‘ 60 a 61 b 62 c 63 d 64 e 65 f 66 g 67 h 68 i 69 j 6A k 6B l 6C m 6D n 6E o 6F

Hex p 70 q 71 r 72 s 73 t 74 u 75 v 76 w 77 x 78 y 79 z 7A { 7B | 7C } 7D ~ 7E DEL 7F

Note: Prefix / Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry.

Cordless System Manual

4–9

Page 60

Data Format Editor This selection provides editing of all input (scanned) data. All Industrial and Retail symbologies can be formatted. Scanning the Default Data Format bar code will program the Cordless System to the default Data Format, which is none. Be certain you want to delete or clear all formats before you scan the Default Data Format bar code. Default Data Format = none. To make Data Format Editor selections, you must know the terminal type, code I.D., code length, and editor commands your application requires. Use the Alphanumeric bar codes (inside back cover) to scan these options. Use the Data Format Editor by following the steps below: ➊ ➋

➌

Scan the Enter Data Format bar code to start Format Editor selection. Terminal Type Scan two bar codes that represent the terminal type (00-99[, see page 2–4 for Terminal I.D. list.) Code I.D. Refer to the Symbology chart (page 4–9), then scan two bar codes from the “Hex Value” column that represent the Code I.D. of the symbology you want formatted. (“All Symbologies” – hex value 99 – is not supported by Data Formatter.)

➍

Length Scan four numeric bar codes (inside back cover) for the bar code length you require (0000-9999]). Be sure to include spaces.

➎

Editor Command Sequences Refer to the Format Editor Commands chart (page 4–12). Scan two bar codes that represent the command you need.

➏

End Data Format Editor Scan Save Current Changes to end Data Format Editor programming.

[ 99 is the universal terminal type, indicating all terminal types. ] 9999 is the universal length, indicating all bar code lengths. Other Programming Selections: You may also clear, save or discard your Data Format changes, by scanning either:

4–10

H

Clear One Data Format programming bar code. This deletes Data Format selections. Scan the Terminal I.D., Code I.D. and the length of the format you want to delete. All other formats are unaffected.

H

Clear All Data Formats programming bar code. This deletes all Data Format selections.

H

Save Current Changes programming bar code. This exits, saving the Data Format selections you just assigned.

H

Discard Current Changes programming bar code, found on the Programming Chart (inside back cover). This exits without changing the Data Format selections.

Cordless System Manual