Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 5 of 12

Cordless System Manual: SCANTEAM 2070 Base, SCANTEAM 3470 CCD, SCANTEAM 5770 Laser, pages 41 to 50

Pages 41 to 50 of 112

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP ST3470

Page 41

Parity Selection This selection provides a means of checking character bit patterns for validity. The Auxiliary Port can be configured to operate under Even, Odd, Mark, None, or Space parity options. The device connected to the Auxiliary Port must be set up for the same parity as the Aux Port to ensure reliable communication.

✱ None

Space

Mark

Even

Odd

Word Length Data Bits Selection This selection sets the Word Length at seven or eight bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications requiring use of the full ASCII set, select 8 data bits per character.

✱ 8 Data Bits

7 Data Bits

Cordless System Manual

3–7

Page 42

Word Length Stop Bits Selection This selection sets the Word Length at one or two stop bits.

✱ 1 Stop Bit

2 Stop Bits

Protocol Selection This selection programs the Auxiliary Port for the protocol required by the input device to the Auxiliary Port. The protocol is a set of rules concerning the exchange of data between serially communicating devices. The Auxiliary Port supports Record, Burst, and Ack / Nak protocols when receiving data from an RS-232 device.

✱ Record

Burst

Record Ack / Nak

Block Ack / Nak

Aux Port I.D. Transmit Selection This will attach the Aux Port identifier (which is the letter “r”) to the incoming data at the Auxiliary Port and will send it along with the data to the host device.

✱ Off

On

3–8

Cordless System Manual

Page 43

Hardware Flow Control Selection This selection turns on hardware flow control that checks for a CTS signal before sending data. This option is useful when your application supports the CTS signal.

✱ Off

On

Note: The Auxiliary Port receive function will only work properly if RTS/CTS or ACK/NAK flow control is used. If your host system does not support RTS/CTS or ACK/NAK handshaking, some or all of your data will be lost.

Data Character Selection This selection selects the serial output data characters that may be sent from the RS-232 device connected to the Auxiliary Port. Default SOR Character = none (NUL: 00). Default EOR Character = Carriage Return (CR: 0D). Default SOB Character = none (NUL: 00). Default EOB Character = End of Text (EOT: 04).

SOR (Start of Record) ]

EOR (End of Record) ]

SOB (Start of Block) ]

EOB (End of Block) ]

] A two-digit number and Save are required after scanning this programming bar code. Refer to the Programming Chart (inside back cover).

Cordless System Manual

3–9

Page 44

Aux Prefix and Suffix Aux Prefix and Suffix characters are data characters you may assign to incoming Auxiliary Port data. Data frame –>

Prefix

Message

Suffix

Characters for the Prefix and Suffix are selected by their hexadecimal ASCII value, up to 12 characters each. Prefix and Suffix characters may be assigned to all incoming data. Default Prefix (incoming data) = none. Default Suffix (incoming data) = none. Default Prefix (outgoing data) = none. Default Suffix (outgoing data) = Carriage Return (CR). Programming Steps to Add an Aux Prefix / Suffix to Incoming Data: ➊

To add a Prefix, scan the Add Aux Prefix programming bar code. To add a Suffix, scan the Add Aux Suffix programming bar code.

➋

Scan two bar codes for the Hex Value “72” (“r,” which represents the identifier for the Aux Port). Scan the two digits on the Programming Chart (on the inside back cover of this manual).

➌

Refer to the Hex ASCII Chart (page 3–12) to find the Hex value that represents the ASCII characters you wish to attach to the data. Use the Programming Chart (inside back cover) to scan the alphanumeric combination that represents the ASCII characters.

➍

To complete Aux Prefix / Suffix programming, scan either: H Save Current Changes programming bar code. This exits, saving the Prefix / Suffix selections you just assigned. H Discard Current Changes programming bar code. This exits without changing the Prefix / Suffix.

Other Programming Selections: Scanning the Default Prefix or Default Suffix bar code sets the default Prefix or Suffix (shown above). Other Programming Selections: Scanning the Clear All Prefixes or Clear All Suffixes bar code deletes all Prefix or Suffix selections.

Note: Aux Prefix / Suffix programming examples may be found on page 3–12.

3–10

Cordless System Manual

Page 45

Aux Prefix Selection

Add Aux Prefix ]

✱ Clear All Prefixes (default)

Aux Suffix Selection

Add Aux Suffix ]

✱ Clear All Suffixes (default)

Exit Selection for Aux Prefix / Suffix

Save Current Changes

Discard Current Changes

] One or more two-digit numbers and Save are required after scanning this programming bar code. Refer to the Programming Chart (inside back cover).

Cordless System Manual

3–11

Page 46

Aux Prefix and Suffix Examples Example 1: Add a Prefix To add an HT (tab) Prefix to incoming data: H Scan the Add Aux Prefix Prefix Selection bar code. H Scan 7 and 2 on the Programming Chart (inside back cover). H An “HT” is equivalent to “09” (see the Hex ASCII Chart). Scan 0 and 9 on the Programming Chart. H Scan the Save Current Changes Exit Selection bar code. Example 2: Add a Suffix To add a CR (carriage return) Suffix to incoming data: H Scan the Add Aux Suffix Suffix Selection bar code. H Scan 7 and 2 on the Programming Chart (inside back cover). H A “CR” is equivalent to “0D” (see the Hex ASCII Chart). Scan 0 and D on the Programming Chart. H Scan the Save Current Changes Exit Selection bar code.

Hex to ASCII Conversion Chart ASCII

Hex

ASCII

Hex

ASCII Hex ASCII Hex ASCII Hex ASCII Hex ASCII Hex ASCII

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F

DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

SP 20 ! 21 ” 22 # 23 $ 24 % 25 & 26 ’ 27 ( 28 ) 29 * 2A + 2B , 2C – 2D . 2E / 2F

3–12

0 1 2 3 4 5 6 7 8 9 : ; < = > ?

30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F

@ 40 A 41 B 42 C 43 D 44 E 45 F 46 G 47 H 48 I 49 J 4A K 4B L 4C M 4D N 4E O 4F

P 50 Q 51 R 52 S 53 T 54 U 55 V 56 W 57 X 58 Y 59 Z 5A [ 5B \ 5C ] 5D ^ 5E _ 5F

Cordless System Manual

‘ 60 a 61 b 62 c 63 d 64 e 65 f 66 g 67 h 68 i 69 j 6A k 6B l 6C m 6D n 6E o 6F

Hex p 70 q 71 r 72 s 73 t 74 u 75 v 76 w 77 x 78 y 79 z 7A { 7B | 7C } 7D ~ 7E DEL 7F

Page 47

Aux Data Format Editor This selection provides editing of all incoming data to the Auxiliary Port. Scanning the Default Data Format bar code will program the Cordless System to the default Data Format, which is none. Be certain you want to delete or clear all formats before you scan the Default Data Format bar code. Default Data Format = none. To make Data Format Editor selections, you must know the terminal type, code length, and editor commands your application requires. Use the Alphanumeric bar codes (inside back cover) to scan these options. Use the Aux Data Format Editor by following the steps below: ➊ ➋

➌

Scan the Enter Aux Data Format bar code to start Format Editor selection. Terminal Type Scan two bar codes that represent the terminal type of the data’s destination (00-99[, see page 2–4 for Terminal I.D. list.) Code I.D. Scan two bar codes for the Hex Value “72” (“r,” which represents the I.D. for the Aux Port).

➍

Length Scan four numeric bar codes (inside back cover) for the bar code length you require (0000-9999]). Be sure to include spaces.

➎

Editor Command Sequences Refer to the Format Editor Commands chart (page 3–15). Scan two bar codes that represent the command you need.

➏

End Data Format Editor Scan Save Current Changes to end Data Format Editor programming.

[ 99 is the universal terminal type, indicating all terminal types. ] 9999 is the universal length, indicating all bar code lengths. Other Programming Selections: You may also save or discard your Data Format changes, by scanning either: H

Clear One Data Format programming bar code. This deletes Data Format selections. Scan the Terminal I.D., 7 and 2, and the length of the format you want to delete. All other formats are unaffected.

H

Save Current Changes programming bar code. This exits, saving the Data Format selections you just assigned.

H

Discard Current Changes programming bar code. This exits without changing the Data Format selections.

Cordless System Manual

3–13

Page 48

Aux Data Formatter When Data Formatter is turned off, the incoming data will be output to the host as received (including prefixes and suffixes).

✱ On

Off

Aux Require Data Format? When Data Formatter is required, all input data must conform to an edited format or the Cordless System will not transmit the input data to the host device.

✱ Don’t Require

Require

Aux Data Format Editor See pages 3–13 and 3–15 through 3–16 for a description of this selection, commands, and examples. ✱ Default Data Format (none)

Enter Aux Data Format ]

Clear One Data Format ]

Save Current Changes

Discard Current Changes

] One or more two-digit numbers and Save are required after scanning this programming bar code. Refer to the Programming Chart (inside back cover).

3–14

Cordless System Manual

Page 49

Aux Format Editor Commands Chart Key:

NN = number of characters 00–99 DEC SS = HEX ASCII character 00–7F HEX XX = HEX ASCII character (or function code: F1, F2 only) 00–7F HEX XXXX = 0000 – FFFF x5ms delay

Send Commands F1

Send all characters followed by “XX” key or function code, starting from current cursor position. Syntax = F1XX

F2

Send “NN” characters followed by “XX” key or function code, starting from current cursor position. Syntax = F2NNXX

F3

Send up to but not including “SS” character (Search and Send) starting from current cursor position, leaving cursor pointing to “SS” character followed by “XX” key or function code. Syntax = F3SSXX

F4

Send “XX” character “NN” times (Insert) leaving cursor in current cursor position. Syntax = F4XXNN

E9

Send all but the last “NN” characters from the current position. Syntax = E9NN

Move Commands F5

Move cursor ahead “NN” characters from current cursor position. Syntax = F5NN

F6

Move cursor back “NN” characters from current cursor position. Syntax = F6NN

F7

Move cursor to the beginning of the data string. Syntax = F7

EA Move cursor to the last valid character of the data string. Syntax = EA

Search Commands F8

Search ahead for “XX” character from current cursor position, leaving cursor pointing to “XX” character. Syntax = F8XX

F9

Search back for “XX” character from current cursor position, leaving cursor pointing to “XX” character. Syntax = F9XX

Miscellaneous Commands FA

Leading zero suppress on. Suppress leading zeroes from current cursor position until first non–zero character. Syntax = FA

FB Suppress “XX” character(s) (up to twenty) starting from current cursor position until suppress disable command “FC” or end of format. Syntax = FBXXFB, FBXXXXFB, FBXXXXXXFB, etc. FC Disable suppress filter and clear all suppressed characters. Syntax = FC FE Compare character in current cursor position to the character “XX.” If characters are equal, increment cursor. If characters are not equal, no format match. Syntax = FEXX EC Check for numeric character at current cursor position. If true, then continue format. If false, then no format. ED Check for non-numeric character at current cursor position. If true, then continue format. If false, then no format. EE Leading space suppress on. Suppress leading spaces from current cursor position until first non-space character. Syntax = EE EF Delay function. Syntax = EFXXXX

Cordless System Manual

3–15

Page 50

Aux Data Formatter Example You are sending five digit data into the Auxiliary Port; however, your host system can only accept data which has eight digits. You must add three zeroes to the beginning of the Aux Port data. Received 12345

Must send 00012345

Refer to the Aux Format Editor Commands Chart on page 3–15 to format the following example. The programming bar codes on page 3–14, and the alphanumeric bar codes on the inside back cover are used to program the data formatter. H H H H

Scan the Enter Aux Data Format bar code (page 3–14). Scan the 99 bar codes for Universal Terminal Type. Scan the 72 bar codes, the Hex value for the Auxiliary Port. Scan the 0005 bar codes for the data length.

The following are the Aux Editor Command Sequences: H H H

Scan the F4 (send XX character NN times command) bar codes, scan 30 bar codes (the Hex value for a zero), scan 03 bar codes (send three times). Scan the F1 and 00 bar codes to send all data followed by a NUL (NUL= 00 in Hex value). Scan the Save bar code to end Aux Format Editor selection.

3–16

Cordless System Manual