Page 31

Keyboard Style Modifiers Keyboard Style Modifiers This programming selection allows you to program special keyboard features, such as CTRL+ codes and Turbo Mode. Control + ASCII Mode On – If you scan this selection, the Cordless System sends key combinations for ASCII control characters for values 00–1F. Refer to page 6–1 for CTRL+ Values. Turbo Mode – Selecting Turbo Mode On, (for the IBM AT only), programs the Cordless System to send characters to the terminal faster. Numeric Keypad Mode – Selecting Numeric Keypad Mode On sends numeric characters as if entered from a numeric keypad. Automatic Direct Connect – When Emulate External Keyboard has been selected (above), Automatic Direct Connect Mode keeps the integrated keyboard from becoming permanently disabled. (This selection disables the keyboard for the duration of the bar code transmission.)

Control + ASCII Mode On

✱ Control + ASCII Mode Off

Turbo Mode On

✱ Turbo Mode Off

Numeric Keypad Mode On

✱ Numeric Keypad Mode Off

Automatic Direct Connect Mode On

✱ Automatic Direct Connect Mode Off

Cordless System Manual

2–9

Page 32

Output Delays Selection This selection provides control of the time delays between data output by the Cordless System to the host terminal. The actual delay is 5 milliseconds multiplied by the programmed value (00 – 99). Default = 00.

Intercharacter Delay is the time delay between data characters output by the Cordless System to the host terminal. Interfunction Delay is the time delay between function (key) codes output by the Cordless System to the host terminal. Intermessage Delay is the time delay between data messages or records output by the Cordless System to the host terminal. Example: You need a 45 millisecond delay. Scan the Intercharacter Delay bar code. Scan “0,” “9,” and Save on the Programming Chart (09 x 5ms = 45ms).

Intercharacter Delay (x5mS) ]

Interfunction Delay (x5mS) ]

Intermessage Delay (x5mS) ]

] A two-digit number and Save are required after scanning this programming bar code. Refer to the Programming Chart (inside back cover).

2–10

Cordless System Manual

Page 33

Transmission Rate Selection This programming selection sets the transmission rate from 10 ips (inches per second) to 300 ips if the Cordless System is in Wand Emulation mode. Programming the transmission rate causes the data to be sent at the specified rate. The programmed transmission rate must be compatible with the device receiving the bar code data.

10

✱ 25

40

80

120

150

200

300

Output Polarity Selection This selection allows you to set the output logic convention for the digital output. The choices are White High (“Laser” output) and Black High.

✱ Black High

White High

Cordless System Manual

2–11

Page 34

Reset Factory Settings Scanning the Factory Default Settings bar code resets the Cordless System to the original factory settings, clearing any programming changes you may have made. You may reset the factory default settings for the current application group or for all application groups. Both selections will set the terminal ID to 03. Scan the correct programming below.

Factory Default Settings: Current Application Group

Factory Default Settings: ALL Application Groups

Status Check Scan the Show Base Software Revision bar code to transmit the Cordless Base software revision level to the host terminal. The Base software revision will be printed out as “Base software revision: X.XX, Radio: K.KK.” (The “X’s” and “K’s” will vary according to the firmware revision.)

Show Base Software Revision

Scan the Show Scanner Software Revision bar code to transmit the Cordless Scanner software revision level to the host terminal. The scanner software revision will be printed out as “Scanner software revision: Y.YY, Radio: K.KK.” (The “Y’s” and “K’s” will vary according to the firmware revision.)

Show Scanner Software Revision

2–12

Cordless System Manual

Page 35

Section 3

Communications Menu

Introduction Use this section to program the communications parameters for the Cordless System. This programming section contains the following menu selections: • Host Port Communications (RS-232) • Auxiliary Port Communications (RS-232)

Cordless System Manual

3–1

Page 36

✱ Default All Host Port Communications ✱

Baud Rate Selection This selection sets the baud rate from 300 bits per second to 38,400 bits per second. Programming baud rate causes the data to be sent at the specified rate. The host terminal must be set up for the same baud rate as the Cordless System to ensure reliable communication.

3–2

300

600

1200

2400

4800

9600

19200

✱ 38400

Cordless System Manual

Page 37

Parity Selection This selection provides a means of checking character bit patterns for validity. The Cordless System can be configured to operate under Even, Odd, Mark, None, or Space parity options. The host terminal must be set up for the same parity as the Cordless System to ensure reliable communication.

✱ None

Space

Mark

Even

Odd

Word Length Data Bits Selection This selection sets the Word Length at seven or eight bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications requiring use of the full ASCII set, select 8 data bits per character.

✱ 8 Data Bits

7 Data Bits

Cordless System Manual

3–3

Page 38

Word Length Stop Bits Selection This selection sets the Word Length at one or two stop bits.

✱ 1 Stop Bit

2 Stop Bits

Serial Wedge Output Selection This selection selects the serial output direction required by your application. P1 and P2 are serial wedge designations printed on the serial wedge cable. Usually, one goes to the host and one goes to the terminal, depending on your specific application and the serial wedge cable.

To P1

To P1 and P2

To P2

✱ None (Host Port RS-232)

Hardware Flow Control Selection This selection turns on hardware flow control that checks for a CTS signal before sending data. This option is useful when your application supports the CTS This selection cannot be used with Serial Wedge Output signal. Note: Selection.

✱ Off

On

3–4

Cordless System Manual

Page 39

Host ACK Selection This selection programs the Cordless System to wait for a confirmation signal (ACK) from the host after bar code data has been sent. When Host ACK is turned on, the host system must be programmed to generate Escape Commands (see section below) for user feedback. Page 1–13 in the Getting Started Section explains how Host ACK works and provides an illustration of the feature. Host ACK mode is designed to respond to a specific Application Work Group (see Section 4 for more information on Work Groups); the host system issues an Escape sequence to all scanners in the Work Group. Up to twenty Escape commands may be strung together to create custom beep/blink sequences. An example of an Escape string to create a “low, medium, high” beep sequence for scanners in Application Work Group 2 would be: “2esc4esc5esc6,”. The first character indicates the Work Group and the comma is used as the delimiter.

Note: Host ACK mode will only work with a host system that supports RTS/CTS flow control. If your host system does not support RTS/CTS handshaking, turning on Host ACK selection will cause some or all of your data to be lost.

✱ Off

On

Escape Commands The Cordless System will respond to beep and blink commands from the host system. The format for these commands is: Esc x (where “x” is one of the Escape commands listed below) The table below lists the Escape commands that must be generated from the host system and the resulting action(s). Command

Action

Esc a

Beep (two high tones), illuminate green LED for two seconds

Esc b

Beep (three low tones), illuminate green LED nine times

Esc 1

Illuminate green LED for 135 milliseconds

Esc 2

Illuminate green LED for two seconds

Esc 3

Illuminate green LED for five seconds

Esc 4

One beep at low volume

Esc 5

One beep at medium volume

Esc 6

One beep at high volume

Esc 7

Beep (one medium tone), illuminate green LED two seconds

Esc 8

Beep (three low tones), illuminate green LED nine times

Note: Host ACK may be used with Decode Beep Selection (see page 4–3).

Cordless System Manual

3–5

Page 40

✱ Default All Auxiliary Port Communications ✱

Baud Rate Selection This selection sets the baud rate from 300 bits per second to 38,400 bits per second. Programming baud rate causes the data to be sent at the specified rate. The device connected to the Auxiliary Port must be set up for the same baud rate as the Aux Port to ensure reliable communication.

3–6

300

600

1200

2400

4800

9600

19200

✱ 38400

Cordless System Manual