Page 21

Communication Between the Cordless System and the Host The Cordless Scanner provides immediate feedback in the form of a “good read” indication (a green LED on the scanner and an audible beep) after a bar code is scanned correctly and the base has acknowledged receiving the data. The Cordless System also provides two way communication between the Scanner and the Base or host system. When data is scanned, the data must be accurately sent to the host system via the Base unit. Confirmation from the host system or the Base tells you that the data sent was received by the host. The Cordless Scanner recognizes two forms of host confirmation: data acknowledgement (ACK) from the base unit or an “ACK” from the host system. Acknowledgement from the Base If the Cordless System is configured for a keyboard wedge host interface, a signal (ACK) is sent from the Base confirming that the data was received and is being sent on to the host system. (Since keyboard wedge interfaces cannot provide bi-directional communications, they do not permit host confirmation.) 1) Good Read

2) ACK from Base 3) *

* Base sends data to Host after ACK is sent to Scanner Acknowledgement from the Host System Host system confirmation may be implemented with a bi-directional interface like Host RS-232. In this configuration, when the base unit receives the scanned data from the scanner and forwards it to the host, the Cordless System waits for a signal from the host that it received the data. (For information on enabling this feature and using Host Escape commands, see Host Ack Selection, page 3–5). 1) Good Read 2) Data to Host 4) ACK from Host (via Base) 3) ACK

Cordless System Manual

1–13

Page 22

Accessories for the Cordless System Several accessories are available for the Cordless System. Contact your distributor for more information or to order accessories. Battery Packs Two types of battery packs are available. Each permanently sealed battery pack contains four rechargeable “AA” cells, plus circuitry to allow recharging via standard AC power outlets (eliminating cumbersome and expensive custom charging stations). The entry level battery pack contains NiCad battery cells, while the NiMH battery pack is the premium battery choice with its longer operating and shorter charging time. Each scanner is shipped with one battery pack. Order back up batteries or replacement batteries separately. Charge Strips To recharge more than one Battery Pack at one time, Charge Strips are available. The charge strips recharge either type of battery pack (NiCad or NiMH), are offered in two or six outlet configurations, and may be conveniently wall mounted or set on flat surfaces. The charge strip uses a standard PC (IEC 320) grounded power cord between the charge strip and the electrical AC outlet.

Note: International versions of the power cords are provided by Welch Allyn’s country partners. Welch Allyn does not supply these power cords. Belt Holster The belt holster holds the Cordless Scanner when not in use. The belt holster consists of a foam covered wire frame clasped to an adjustable nylon web belt designed to be worn around the waist. Wall Mount Kit (Standard) The standard wall mount holder stores the Cordless Scanner on a vertical surface for convenient access. The scanner easily slides between two rubberized fingers that hold the scanner when it is not in use. Wall Mount Kit (Industrial) Similar to the standard wall mount holder, the rubberized fingers on the industrial wall mount holder are smaller to maintain a firm grasp on the scanner under jolting and jarring conditions, such as those expected in fork lift applications. Visual Menu Visual Menu is a software configuration tool that provides the ability to configure the Cordless System by connecting the Base unit to the COM port of a PC. Visual Menu allows you to download firmware upgrades, change programmed parameters, and create and print programming bar codes.

1–14

Cordless System Manual

Page 23

Section 2

Quick Start & Interface Menu

Introduction Use this section to program the Cordless System to work with your terminal or computer (host system). This programming section contains the following menu selections: • Plug and Play • Terminal Interface • Country Code • Keyboard • Output Delays • Wand Emulation • Reset Factory Settings and Status Check All operating parameters are stored in non-volatile memory resident in the Cordless System, where they are permanently retained in the event of a power interruption. When you receive your Cordless System, certain operating parameters have already been set. These are the factory defaults, indicated by the symbol “✱” on the programming pages (beneath the default programming bar code). Default Charts that list all the factory settings may be found near the end of this System Manual. A Programming Chart (found on the inside back cover of this manual) contains alphanumeric bar codes for setting additional programming options, such as the digits representing Symbology Message Length. The chart explains how and when to use the alphanumeric bar codes.

Note: After scanning the following menu selections, there will be a pause (up to 20 seconds) while the Base unit processes and uploads the new menuing information to its parameter tables: Plug and Play Selections (on the next two pages) Factory Default Settings: ALL Application Groups (last page, Section 2) Application Work Group Selections (Section 4) A Sample Bar Codes page (located on the back cover of this manual) provides bar code symbols you may scan to verify that your Cordless System has been programmed correctly and is communicating with your host system.

Cordless System Manual

2–1

Page 24

Industrial Interface: IBM PC

IBM PC AT and Compatibles Interface (also PS/2 30-286, 50, 55SX, 60, 70, 70-061, 70-121, 80)

(Factory Default) The bar code above also programs a carriage return (CR) suffix.

Industrial Interface, Aux Port: RS-232

RS-232 Interface

The bar code above also programs the following parameters:

Programmable Option Baud Rate Parity Data Format Prefix Suffix

Setting 38,400 bits per second None 8 data bits, 1 stop bit None Carriage Return (CR)

Note: Plug and Play menu codes will default all settings before programming the interface.

2–2

Cordless System Manual

Page 25

Industrial Interface, Aux Port: Wand Emulation Black High

Wand Emulation (Code 39 Format) Interface

Wand Emulation (Same Code Format) Interface [ These bar codes also program the following parameters:

Programmable Option Transmission Rate Output Polarity

Setting 25 inches per second Black High

Industrial Interface, Aux Port: Wand Emulation White High

Wand Emulation (Code 39 Format) Interface

Wand Emulation (Same Code Format) Interface [ These bar codes also program the following parameters:

Programmable Option Transmission Rate Output Polarity

Setting 25 inches per second White High

[ Supports Code 39, UPC, EAN, Code 128, Interleaved 2 of 5, and Codabar. All other codes output as Code 39.

Cordless System Manual

2–3

Page 26

If your terminal is not one of the Plug and Play options, you must program one of the terminals listed below. To program the terminal interface, scan the Program Terminal Interface bar code below, then scan the appropriate two digit Terminal I.D. code and Save from the Programming Chart on the inside back cover of this manual.

Program Terminal Interface

(Factory Default = ID 03)

Supported Terminals Terminal

Model(s)

Bull DEC DEC DELL DTK

BDS–7 Honeywell (HDS–7) PC433 SE (Portable PC) VT–220, 320, 330, 340, 420 Latitude (Portable PC) 486 SLC (Portable PC)

35 03 04 03 03

Fujitsu IBM IBM IBM

Stylistic (Portable PC) PC XT PS/2 25, 30, 77DX2 AT, PS/2 30–286, 50, 55SX, 60, 70, 70–061, 70–121, 80 AT Compatibles Keyboard Emulation (Non-wedge)

03 01 02 03

Thinkpad 365, 755 CV (Portable PC) 3151, 3161, 3162, 3163, 3179, 3191, 3192, 3194, 3196, 3197, 3471, 3472, 3476, 3477, 3482, 3486, 3488 3179–1, 3191, 3192, 3471, 3472, 3194 3196, 3197, 3476, 3477, 3482, 3486, 3488

03 06

IIS MC–3+, MC–5 MC–3+, MC–5 MC–3+, MC–5 Micro Elite TS 30 PS (Portable PC)

07 15 14 18 03

IBM

IBM IBM 102 Key

IBM 122 Key IBM 122 Key

Lee Data Link ANSI Link ASCII Link Enhanced PC Midwest

2–4

Cordless System Manual

Terminal I.D.

03

07 08

Page 27

Supported Terminals (Factory Default = ID 03) Terminal

Model(s)

Mitak Olivetti Olivetti Relisys RS-232 Host Port

4022 (Portable PC) M19, M24, M28, M200 M240, M250, M290, M380, P500 TR 175

RS-232 Aux Port Serial Wedge Televideo Texas Instruments Toshiba

Terminal I.D.

990, 995, 9060 Extensa 560CD (Portable PC) 2600 (Portable PC)

03 01 03 03 50 00 50 02 03 03

Toshiba Satelite T1960, T2130, CS (Portable PC) Wand Emulation Code 39 output (via Aux Port) Wand Emulation Same Code output (via Aux Port) WYSE WY–30 WYSE WY–85/185

03 [ [ 13 16

WYSE ANSI WYSE ASCII WYSE Enhanced PC Zenith

15 14 18 03

WY 60, 120, 150, 160, 325, 370, 99GT WY 60, 120, 150, 160, 325, 370, 99GT WY 60, 120, 150, 160 Z–note (Portable PC)

[ Use Plug and Play Selections on page 2–3.

Cordless System Manual

2–5

Page 28

Keyboard Country Selection This programming selection allows you to re-map the keyboard layout for the selected country. As a general rule, the following characters are not supported by the Cordless System for countries other than the United States: @ | $ # { } [ ] = / ‘ \ < > ~

✱ United States

Belgium

Denmark, Finland, Norway, Sweden

2–6

France

Germany, Austria

United Kingdom

Switzerland

Italy

Cordless System Manual

Page 29

Keyboard Layout Selection This selection allows you to program the Cordless System to transmit the proper keycodes when interfacing with a “Normal” (PC AT type), telephone, calculator, Alpha, or Numeric keyboard layout. Choose the keyboard layout that defines your keyboard.

✱ Layout 1 (Telephone)

Layout 2 (Calculator)

Layout 3 (PC AT)

Layout 4 (Alpha)

Layout 5 (Numeric)

Cordless System Manual

2–7

Page 30

Keyboard Style Selections Keyboard Style Selections This programming selection allows you to program special keyboard features, such as Caps Lock and Shift Lock. Regular is used when you normally have the Caps Lock key off. Caps Lock is used when you normally have the Caps Lock key on. Shift Lock is used when you normally have the Shift Lock key on. (Not common to U.S. keyboards.) Automatic Caps Lock is used if you change the Caps Lock key on and off. The software tracks and reflects if you have Caps Lock on or off (AT and PS/2 only). This selection can only be used with systems that have an LED that notes the Caps Lock status. Emulate External Keyboard should be scanned if you do not have an external keyboard (IBM AT or equivalent).

✱ Regular

Caps Lock

Shift Lock

Automatic Caps Lock

Emulate External Keyboard

2–8