Page 11
About the Battery Pack Power is supplied to the Cordless Scanner by a rechargeable battery pack that snaps onto the bottom of the scanner. Each scanner is shipped with a battery pack [. Battery packs are offered in a choice of Nickel Cadmium (NiCad) cells, as an entry level solution, or a premium battery pack based on Nickel Metal Hydride (NiMH) cells. (See Battery Specifications, page 7–4, for the differences between the two types of battery packs, as well as storage information.) [ Order backup battery pack(s) or replacement batteries from your distributor. North American Charging Information The battery pack is designed to plug into any two prong North American AC power outlet (110/120 Volt) for direct charging. You need no additional equipment and you can recharge the pack virtually anywhere. If you want surge protection, a charge strip (described below) affords extra protection. Worldwide Charging Information: Charge Strips Since the battery pack is rated for both 110/120 60 Hz and 230/240 volt 50 Hz applications it may be recharged worldwide. For international charging, to accommodate the wide variety of electrical outlets, a custom charge strip is required to charge the batteries. The charge strip supports both versions of battery packs and is offered for two or six battery pack configurations.
Contact your distributor for more information or to order Charge Strips. Battery Pack Recommendations • Charge the battery pack immediately before use or at least within a couple of days of use. • Remove the battery pack from the power outlet or charge strip within 24 hours after charging is completed. Avoid extended overcharging. • Periodically fully discharge the battery pack. • Avoid using the battery pack in extreme temperatures. Do not use or place the charge strip in locations that are extremely hot or cold, dusty or dirty, very humid, or subject to vibration. •
Do not disassemble the battery pack or the charge strip. There are no user-serviceable parts in the battery pack or in the charge strip.
Proper Disposal of the Battery Pack When the battery pack has reached the end of its useful life, the batteries should be disposed of by a qualified recycler or hazardous materials handler. Do not incinerate the battery pack or dispose of the battery pack with general waste materials. Contact the Product Service Department (see page 9–1) for recycling or disposal information.
Cordless System Manual
1–3
Page 12
Charging Your Battery Pack Charge the Battery Pack by following the steps shown below:
➊
Plug the battery pack directly into any common 120 Volt AC outlet.[ To charge more than one battery pack (or to charge the pack for all other countries), use the Charge Strip.
➋
Cordless Scanner
The LED on the bottom of the battery pack will light red when the unit is charging; it shows green when it is fully charged and ready to use.
Charge Time: NiCad Battery Pack 8 hours at 120 VAC, 60 hz 4 hours at 220 VAC, 60 hz 5 hours at 220 VAC, 50 hz NiHM Battery Pack 4 hours at any voltage and frequency
➌
After the battery pack is fully charged, attach it to the Cordless Scanner by pressing the pack firmly (align the prongs on the pack with the mating receptacles) in the base of the scanner until the release buttons click, holding the pack firmly in place. (When you attach a charged battery pack to the Cordless Scanner, you will hear a single beep.)
Rechargeable Battery Pack
➍ If you haven’t set up your Cordless System, turn to the next page for instructions. When the battery pack needs recharging, the yellow LED on top of the scanner pulses in short, continuous blinks and the scanner won’t beep when you pull the trigger. If the LED stops flashing when the temperature lowers or you do not use the battery pack for some time, you still need to charge the battery pack to avoid damaging the battery pack or causing scanner memory loss.
[ Plug the battery pack into a wall socket in North America only. Failure to comply could result in equipment failure.
1–4
Cordless System Manual
Page 13
Setting Up and Connecting the Cordless System Install the Base and Cordless Scanner by following the steps shown below:
Important: Make sure the Cordless Scanner’s battery pack has been fully charged. See page 1–4 for charging instructions.
➊
Turn off the power to the host system.
➋
Connect the interface cable to the Base and to the terminal/computer (steps 1–3, shown in the illustration below). Depending on your application, the interface cable you need may be different than the one shown below.
Keyboard Wedge Interface Example Terminal (host system)
3
Cordless Base
Disconnect
2 1
(Cable, Keyboard, and Terminal may vary.) Note: For optimal coverage, place the Base and its antenna as far away from other sources of RF interference, with a clear transmitting path to the scanner(s). The Base can be mounted on a wall or a ceiling. Try to place the Base so that the antenna is in a vertical (straight up and down) position whenever possible. An extra Base Association Bar Code is provided in case the Base is mounted where the label might be difficult to scan (step 4 on the next page describes the Association process). In an RS-232 configuration (see the illustration on the next page), connect your interface cable between the Base unit (step 1 in the illustration) and the host system (2). You also need to use an external power supply (3). Contact your distributor for more information on ordering power supplies or RS-232 cables, including a “Y” extension power cable to mount the base for best RF coverage.
Cordless System Manual
1–5
Page 14
Setting Up and Connecting the Cordless System, continued
RS-232 Interface Example Terminal (host system)
2
Cordless Base
1
3
Power Supply
(Cable, Keyboard, and Terminal may vary.) ➌
Turn on the power to the host system. Verify that the Base is on; the green LED on top of the unit should blink. (The Base does not have a beeper.)
➍
Using the Cordless Scanner, scan the Association Bar Code (the bar code label on the top of the Base) to link that scanner to the Base (see the illustration shown below).
Cordless CCD or Laser Scanner Association Bar Code
Cordless Base Two quick beeps followed by a single beep (with a short delay in between) from the scanner indicates a “good” association. The scanner is in communication with the Base.
1–6
Cordless System Manual
Page 15
Setting Up and Connecting the Cordless System, continued
Note: After association, if the battery pack is removed from the scanner and replaced, the scanner will automatically re-associate to the base if the base has remained powered up. In this case, the scanner will beep when a charged battery pack is installed and will beep a second time after full association, about five to ten seconds later. After your Cordless Scanner has been associated with its base unit:
➎
Program your Cordless System to work with your terminal or computer by scanning the Terminal Setup Codes. Use the Supported Terminal list (Pages 2–4 to 2–5) to scan your terminal’s Terminal ID.
With Plug and Play programming, you scan only one bar code to program the Cordless System to work with a designated interface, including any required prefixes and suffixes.
➏
To determine if your Cordless System is set up correctly, scan one of the sample bar codes on the back cover of this manual.
Connecting More Scanners to the System Up to nine Cordless Scanners may be associated with one Base unit [. Add more Cordless Scanners to a Base unit by following the steps shown below:
➊
Make sure the Cordless Scanner’s battery pack has been fully charged.
➋
Scan the Association Bar Code (the bar code label on the top of the Base) to link each scanner to the Base.
The Base stores a unique I.D. for each scanner (up to nine) to identify the scanner during data communication. Two beeps followed by a single beep from the scanner indicates a “good” association. The Base rejects a tenth Cordless Scanner trying to link to its network, sending the scanner an error command. (A rejected scanner beeps three times, indicating an unsuccessful association.)
Note: When you associate more scanners with the Base, you don’t have to program your Cordless System to communicate with your terminal or computer if you’ve already completed step 5, above.
[ within a 50 foot (15.24 meter) radius of the base, in an open air environment
Cordless System Manual
1–7
Page 16
Beeper and LED Sequences and Meaning The Base contains a green LED that indicates the status of the unit and verification of its communication with the host system. The Cordless Scanner contains a beeper and two LEDs on the top of the unit (green and yellow) to indicate its power up, communication, and battery pack status. The tables below list the indication and meaning of the beeps and LED illumination for the Base and Cordless Scanner. Base LED Indication Sequence
Meaning
LED on continuously
Power on, system idle
LED blinks, long duration
Power on, diagnostic error
LED blinks, short duration
Receiving data from Scanner, Host or Aux Port
LED blinks, four long pulses
Communication error detected
Scanner LED Indication Sequence
Meaning
Green LED on
Trigger pulled, out of range
Green LED on, two seconds
Successful decode and communication
Green LED blinks, two seconds
Successful decode with unsuccessful communication or unsuccessful clear to scanner
Green LED on, five seconds
Enter/exit programming mode, successful parameter change in programming mode
Green LED blinks, five seconds
Unsuccessful parameter change in programming mode
Yellow LED on
Scanning, trigger pulled (in or out of range)
Yellow LED blinks
Low battery (trigger pulled)
Scanner Beep Indication Sequence
Meaning
No beep
No scanning, scanning or low battery (trigger pulled)
One beep
Successful decode and communication
Three beeps, same tone
Successful decode with unsuccessful communication or unsuccessful clear to scanner, unsuccessful association to Base (10th scanner), out of range
Three beeps, two high and one low tone
Enter/exit programming mode or successful association to Base, Successful or unsuccessful parameter change in programming mode
1–8
Cordless System Manual
Page 17
Basic Operation of the Cordless System The following system block diagrams (on this and the following page) illustrate the basic operating components of the Cordless System. Cordless Base The Cordless Base provides the link between the Cordless Scanner and the host system. The Base contains a control/interface assembly and an RF communication module. The RF communication module performs the data exchange between the Cordless Scanner and the control/interface assembly. The control assembly coordinates the central interface activities including: transmitting/receiving commands and data to/from the host system, performing software activities (parameter menuing, visual indicator support, power-on diagnostics), and data translation required for the host system.
Cordless Base
RF Module
Control/Interface Assembly (Base Circuit Board)
Base Housing
Control
Antenna
User I/O
Menu I/O
Host I/O
Multipoint
LED I/O Ports RF
Host
Power
Aux
RF (Radio Frequency) Module Operation The Cordless System uses a state of the art radio to transmit and receive data between the scanner and the Base. Designed for point-to-point and multipoint to single point applications, the radio transmits data at a rate of 1 megabit per second (MBPS) in a half duplex (2 way) communications mode. The radio operates using a license free, low power, 2.4 GHz spread spectrum (frequency hopping) technique. This transmission technique, which sends relatively small data packets at a fast data rate over a radio signal with randomly changing frequencies, makes the Cordless System highly responsive to a wide variety of data collection applications and resistant to noisy RF environments. The RF radio used in the Cordless System has been tested and approved as complying with the two leading standards-setting organizations that serve as regulatory models for compliance in most countries. In North America, the radio is approved under the standards in FCC B Part 15.249 regulations and, in Europe, under the standards in ETS 300 328 regulations. (See page 7–5 for a chart of regulatory and safety agency approvals.)
Cordless System Manual
1–9
Page 18
Cordless Scanner The Cordless Scanner enables bar code scanning with non-contact CCD or Laser input devices, real time decoding, and host connectivity within a 50 foot (15.24 meter)[ radius of the Base unit. It provides the initial bar code data acquisition function and communicates to the Base. The scanner is comprised of a CCD or laser scan engine, a decode/control assembly, and an RF communication module. The scan engine performs the bar code image illumination and detection. The decode/control assembly coordinates the central communication activities including: capturing and decoding the bar code image data, performing software activities (parameter menuing, visual indicator support, low battery indication), and data translation required for the host system. The RF communication module performs the data exchange between the scanner and the Base.
Cordless Scanner Scanner Assembly Engine Assembly Scan Engine (CCD or Laser)
Decode/Control Assembly (Handle Board) HHLC I/O
Engine Port Control Menu I/O Trig/Decode
Beeper Antenna Engine Hsg Window/Lt Pipe
Trigger Handle Housing
Power Mgmt
Beeper Port RF Module
RF Port Download Port Battery Port
Battery Pack (600 or 1.2 mAh)
[ A 50 foot (minimum) radius is maintained in most environments. For optimal performance, signals between the Base and its scanners need a clear path to communicate, free from RF interference.
1–10
Cordless System Manual
Page 19
System Conditions The components of the Cordless System interact in specific ways as you associate one or more scanners to a Base, as you move a scanner out of range, bring a scanner back in range, replace a scanner battery pack, or swap scanners between two Cordless Systems. The following information explains the Cordless System operating conditions. Association Process After you scan the association label, the Base synchronizes radio parameters and the work group parameter table in the scanner. The work group table is uploaded after the scanner emits two high pitched beeps and before a third beep (with a short delay in between). The Base blinks while it is sending the table to the scanner. Until the table is uploaded, scanning and data transmission will be interrupted. If the Base is off or not working properly, the scanner will give an error (triple) beep after trying for 30 seconds to associate to the Base. The work group table is also uploaded any time the Base believes a previously associated scanner wishes to join the network. A scanner always tries to join the last Base it was associated to, even if the scanner has been without power for several days. The Base allows a scanner to associate as long as there are fewer than nine scanners actively associated to the Base. When the uploading process is complete, the re-associated scanner will beep. Scanner is Out of Range The Cordless Scanner is always in communication with its Base, even when it is not transmitting bar code data. Whenever the scanner can’t communicate with the Base for a three second interval, it is out of range. If the trigger is pulled while the scanner is out of range, the green and yellow LEDs illuminate. When you scan a bar code, the scanner tries to send its data to the Base. A second later, if there is still no acknowledgement from the Base, the scanner triple beeps indicating that the data did not transmit and the green LED will flash for five seconds or until the next trigger pull.
Note: While the scanner is out of range, it consumes more power searching for the Base continuously. To conserve battery power, store the scanner with the battery pack removed. Scanner is Moved Back Into Range The scanner will silently rejoin (no beep after connecting and synchronizing with the Base) if the scanner has not been reset (battery pack disconnected and reconnected), no menu codes have been scanned by other scanners in the work group, or the Base has not been reset (see Base Reset Conditions, next page). Any one of these three conditions can cause the scanner to go through a re-association process (definition on the next page) when it is moved back in range. If the scanner re-associates, you will hear a single beep when the re-association process (uploading of the parameter table) is complete. If you believe you are in range and are still hearing a triple (error) beep, you may have been removed from off the Base’s network. Try scanning the association label or reset scanner by removing and reinserting the battery.
Cordless System Manual
1–11
Page 20
Replacing Battery Pack While Associated When you insert the battery pack, the scanner will beep followed by a pause. During this pause, the work group parameter table is uploaded to the scanner from the Base. Scanning and data transmission will be interrupted. When the scanner emits a second beep, you may scan again. If you don’t receive a second beep, the table was not transferred successfully either because the scanner was out of range or all of the data was not received. Scan the association label again. Moving Scanners From One Base to Another You may transfer a scanner between Base networks by scanning a new Base association label. Scanners can only be associated to one Base at a time. Once a scanner has been associated to a Base, it will try to stay associated to that Base until a new Base association label has been scanned. The new Base will add a scanner to its association list as long as fewer than nine scanners are in its network. If a Base has nine scanners in its network, you will need to disassociate one scanner before adding another (see next section). Swapping Scanners Between Two Systems with Nine Scanners on Each You may use the Remove Scanner Selection (page 4–3) to disassociate any scanner and then add a new scanner by scanning the association label with the new scanner. If you cannot scan the disassociation label because the scanner you are trying to disassociate was damaged, remove power from that scanner and it will automatically disassociate in approximately three seconds.
Glossary Base Reset Conditions The Base will reset when Base power is lost or when a diagnostic problem is sensed. In either case, the scanners will automatically re-associate, if they are within range. Re-association The process of uploading the work group parameter table from the Base and having the scanner give a single beep upon completion is called ”re-association.” This is done automatically, without having to scan an association label. Association List The Base keeps an association list of up to nine entries. This list maintains the associated scanners’ radio serial numbers and dynamic addresses. New dynamic addresses are assigned to the scanners each time a Base Reset occurs. This helps the Cordless System track the status of the different scanners in its network during the association and re-association process.
1–12
Cordless System Manual