Page 61

Data Formatter When Data Formatter is turned off, the bar code data will be output to the host as read (including prefixes and suffixes).

✱ On

Off

Require Data Format? When Data Formatter is required, all input data must conform to an edited format or the Cordless System will not transmit the input data to the host device.

✱ Don’t Require

Require

Data Format Editor See pages 4–10 and 4–12 through 4–13 for a description of this selection, commands, and examples. ✱ Default Data Format (none)

Enter Data Format ]

Clear One Data Format ]

Save Current Changes

Clear All Data Formats

] One or more two-digit numbers and Save are required after scanning this programming bar code. Refer to the Programming Chart (inside back cover).

Cordless System Manual

4–11

Page 62

Format Editor Commands Chart Key:

NN = number of characters 00–99 DEC SS = HEX ASCII character 00–7F HEX XX = HEX ASCII character (or function code: F1, F2 only) 00–7F HEX XXXX = 0000 – FFFF x5ms delay

Send Commands F1

Send all characters followed by “XX” key or function code, starting from current cursor position. Syntax = F1XX

F2

Send “NN” characters followed by “XX” key or function code, starting from current cursor position. Syntax = F2NNXX

F3

Send up to but not including “SS” character (Search and Send) starting from current cursor position, leaving cursor pointing to “SS” character followed by “XX” key or function code. Syntax = F3SSXX

F4

Send “XX” character “NN” times (Insert) leaving cursor in current cursor position. Syntax = F4XXNN

E9

Send all but the last “NN” characters from the current position. Syntax = E9NN

Move Commands F5

Move cursor ahead “NN” characters from current cursor position. Syntax = F5NN

F6

Move cursor back “NN” characters from current cursor position. Syntax = F6NN

F7

Move cursor to the beginning of the data string. Syntax = F7

EA Move cursor to the last valid character of the data string. Syntax = EA

Search Commands F8

Search ahead for “XX” character from current cursor position, leaving cursor pointing to “XX” character. Syntax = F8XX

F9

Search back for “XX” character from current cursor position, leaving cursor pointing to “XX” character. Syntax = F9XX

Miscellaneous Commands FA

Leading zero suppress on. Suppress leading zeroes from current cursor position until first non–zero character. Syntax = FA

FB Suppress “XX” character(s) (up to twenty) starting from current cursor position until suppress disable command “FC” or end of format. Syntax = FBXXFB, FBXXXXFB, FBXXXXXXFB, etc. FC Disable suppress filter and clear all suppressed characters. Syntax = FC FE Compare character in current cursor position to the character “XX.” If characters are equal, increment cursor. If characters are not equal, no format match. Syntax = FEXX EB Solicit auxiliary port mode On/Off (Toggle). Send characters out auxiliary port using F1, F2, F3, F4 commands. Syntax = EB EC Check for numeric character at current cursor position. If true, then continue format. If false, then no format. ED Check for non-numeric character at current cursor position. If true, then continue format. If false, then no format. EE Leading space suppress on. Suppress leading spaces from current cursor position until first non-space character. Syntax = EE EF Delay function. Syntax = EFXXXX

4–12

Cordless System Manual

Page 63

Data Formatter Example You are using an IBM PC AT and are scanning a UPC A bar code with a five digit addenda (shown below). The bar code has a total of 18 characters, including the number system, the check digits, and a space between the main bar code data and the addenda bar code data. UPC A with 5 digit addenda 56098

0 12345 67890 5

For your application, you don’t want the space between the main bar code data and the addenda bar code data transmitted. You also want the bar code data followed by a carriage return (CR). Refer to the Format Editor Commands Chart on page 4–12 to format the following example. The programming bar codes on page 4–11, and the alphanumeric bar codes on the inside back cover are used to program the data formatter. H H H H

Scan the Enter Data Format bar code (page 4–11). Scan the 03 bar codes for PC AT Terminal Type. Scan the 63 bar codes, the Hex value for UPC symbology. Scan the 0018 bar codes for the bar code length.

The following are the Editor Command Sequences: H H H H

Scan the FB (suppress characters command) bar codes, scan 20 (the Hex value for a space), and then scan FB to frame (complete) the command. Scan the F7 bar codes to move the cursor back to the beginning of the bar code data. Scan the F1 and 0D bar codes to send all the characters followed by a carriage return (CR= 0D in Hex value). Scan the Save bar code to end Format Editor selection.

Cordless System Manual

4–13

Page 64

4–14

Cordless System Manual

Page 65

Section 5

Symbology Menu

Introduction Use this section to program the Cordless System for Industrial and Retail Symbology selections. This programming section contains the following menu selections: • Matrix 2 of 5 • Codabar • Code 11 • Code 39 • Code128 • Code 93 • EAN • Interleaved 2 of 5 • UPC • Code 2 of 5

Programming Tip: If a symbology will not be used, we recommend turning it off to maximize the Cordless System’s decoding speed.

Cordless System Manual

5–1

Page 66

✱ Default All Codabar Settings ✱

Codabar Selection

✱ On

Codabar

Off

Transmit

Start / Stop Characters

✱ Don’t Transmit

Minimum ]

Message Length

Maximum ]

] A two-digit number and Save are required after scanning this programming bar code. Refer to the Programming Chart (inside back cover).

5–2

Cordless System Manual

Page 67

Codabar Selection, continued

Validate

Check Character

✱ Don’t Validate

Transmit

Check Character

✱ Don’t Transmit

Concatenation Codabar supports symbol concatenation. When you turn concatenation on, the reader will look for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two messages are concatenated into one with the “D” characters omitted. Character: Start

Stop Start

Stop

Codabar A12D

D34A

Select Require to prevent the reader from decoding a lone Codabar symbol.

✱ On

Concatenation

Off

Require

Concatenation

✱ Don’t Require

Cordless System Manual

5–3

Page 68

✱ Default All Code 39 Settings ✱

Code 39 Selection

✱ On

Code 39

Off

Transmit

Start / Stop Characters

✱ Don’t Transmit

Minimum ]

Message Length

Maximum ]

Validate

Check Character

✱ Don’t Validate

Transmit

Check Character

✱ Don’t Transmit

] A two-digit number and Save are required after scanning this programming bar code. Refer to the Programming Chart (inside back cover).

5–4

Cordless System Manual

Page 69

Code 39 Selection, continued

✱ On

Full ASCII

Off

On

Append

✱ Off

FULL ASCII CHART [ NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI

%U $A $B $C $D $E $F $G $H $I $J $K $L $M $N $O

DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

$P $Q $R $S $T $U $V $W $X $Y $Z %A %B %C %D %E

SP SPACE ! /A ” /B # /C $ /D % /E & /F ’ /G ( /H ) /I * /J + /K , /L – – . . / /O

0 1 2 3 4 5 6 7 8 9 : ; < = > ?

0 1 2 3 4 5 6 7 8 9 /Z %F %G %H %I %J

@ A B C D E F G H I J K L M N O

%V A B C D E F G H I J K L M N O

P Q R S T U V W X Y Z [ \ ] ^ _

P Q R S T U V W X Y Z %K %L %M %N %O

‘ %W a +A b +B c +C d +D e +E f +F g +G h +H i +I j +J k +K l +L m +M n +N o +O

+P p +Q q +R r +S s +T t +U u +V v +W w +X x +Y y +Z z %P { %Q | %R } %S ~ DEL %T

[ This chart is used for encoding the above characters in Full ASCII when using Code 39 bar codes. For example, to get a “<”, encode %G into the bar code symbol.

Cordless System Manual

5–5

Page 70

✱ Default All Code 93 Settings ✱

Code 93 Selection

✱ On

Code 93

Off

Minimum ]

Message Length

Maximum ]

] A two-digit number and Save are required after scanning this programming bar code. Refer to the Programming Chart (inside back cover).

5–6

Cordless System Manual