Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 10 of 12

Cordless System Manual: SCANTEAM 2070 Base, SCANTEAM 3470 CCD, SCANTEAM 5770 Laser, pages 91 to 100

Pages 91 to 100 of 112

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP ST3470

Page 91

Keyboard / Terminal and RS-232 (Host Port) Connector The cordless Base can output data to keyboard wedge terminals, CRT terminals, and personal computers. The Base also provides direct RS-232 output.

8

1

15

9

Terminal selection may be programmed using Section 1, the “Plug and Play” or Terminal Interface Selections. Output data can be configured for your application by using the System Manual, Sections 2 through 4 (Output Parameters, General Operating, and Symbology Menus). Keyboard / Terminal and RS-232 (Host Port) Connector: DB–15 Pin Female Pin

Signal Name

Description

1

GND

Power/Signal Ground

2

VCC

5 Volt DC Power Out

3

RXD

RS-232 Receive Data (input)

4

CTS

RS-232 Clear to Send (input)

5

KDATA

Keyboard Data from Keyboard

6

KCLK

Keyboard Clock from Keyboard

7

Reserved

Future use

8

Reserved

Future use

9

VIN

High Voltage Power (input, maximum = 14 VDC)

10

BSTRAP

MCU Bootstrap Mode Startup Signal (input)

11

TXD

RS-232 Transmit Data (output)

12

RTS

RS-232 Request to Send (output)

13

TDATA

Keyboard Data to Terminal

14

TCLK

Keyboard Clock to Terminal

15

Reserved

Future use

External Power Connector DC power to the cordless Base can come from an external power supply or from the terminal to which the Base is connected. External power is provided through a two-position barrel-type connector on the Base’s back panel. The input voltage range is 4 VDC to 14 VDC and the schematic diagram is shown below. Ground

+9 Volts DC (example)

Cordless System Manual

7–7

Page 92

4.5 in [11.5 cm]

Top View 4.0 in [10.2 cm]

Front View

1.4 in [3.6 cm]

3/4 View

Side View

7–8

Cordless System Manual

Page 93

6.00 in [15.24 cm] 4.72 in [11.99 cm]

Top View 3.06 in [7.77 cm]

1.45 in [3.68 cm]

Front View 8.28 in [21.03 cm]

1.60 in [4.06 cm]

3/4 View

Side View

Cordless System Manual

7–9

Page 94

Typical Performance at 20°C for SCANTEAM 3470LR

3.5” 4.0”

7.0”

7 mil 3.0

13 mil

1.5

4.5

Cm.

4

10.16

3

7.62

2

5.08

1

2.54

0

0

1

2.54

2

5.08

3

7.62

4

10.16

6.0

20 mil

ACAP

In.

7.0

40 mil

ACAP

8.0 ACAP = As close as possible.

In.

0

1

2

3

4

5

6

7

8

Cm.

0

2.54

5.08

7.62

10.16

12.7

15.24

17.78

20.32

Typical Depth of Field in Inches/Centimeters In. Cm. 12 30.48

Typical Performance at 20°C for SCANTEAM 5770STD

3.5”

7”

14”

20”

28”

34”

8

20.32

4

10.16

0

0

4

10.16

8

20.32

12

30.48

5 mil 2.5

3.5 7.5 mil 7.0

2.0 13 mil ACAP

14.0

20 mil

ACAP

20.0

40 mil

ACAP

28.0

55 mil

ACAP

34.0 ACAP = As close as possible.

In. Cm.

0 0

5 12.7

10 25.4

15 38.1

20 50.8

25 63.5

30 76.2

Typical Depth of Field in Inches/Centimeters

7–10

Cordless System Manual

35 88.9

Page 95

Typical Performance at 20°C for SCANTEAM 5770LR

37.5”

18.5”

78.5”

88.5”

In.

Cm.

20

50.8

16

40.64

12

30.48

8

20.32

4

10.16

0

0

4

10.16

8

20.32

12

30.48

16

40.64

20

50.8

32.5”

10 mil 10.5

18.5 15 mil

7.5

32.5 20 mil

7.5

37.5 40 mil

8.5

78.5 55 mil

8.5

88.5

In.

0

25

50

75

100

Cm.

0

63.5

127

190.5

254

Typical Depth of Field in Inches/Centimeters

Two additional depth of field measurements, using special reflective bar code targets, are shown below: Target X Dimension

Near Distance

Far Distance

70-mil reflective

68 inches (172.7 cm)

13.4 feet (4.08 m)

100-mil reflective

82 inches (208.3 cm)

17.4 feet (5.30 m)

Cordless System Manual

7–11

Page 96

7–12

Cordless System Manual

Page 97

Section 8

Maintenance and Troubleshooting

Maintenance The Cordless Scanning System provides reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks ensure dependable operation: Cleaning the Scan Window of the Cordless Scanner Scanning performance may degrade if the Cordless Scanner’s scan window is not clean. If the window is visibly dirty, or if the scanner isn’t scanning well, clean the scan window with a soft cloth or facial tissue dampened with water (or a mild detergent– water solution). If a detergent solution is used, rinse with a clean tissue dampened with water only.

The Cordless Scanner and Base housings may also be cleaned the same way. Inspecting Cords and Connectors Inspect the Cordless Base’s interface cable and connector for wear or other signs of damage. A badly worn cable or damaged connector may interfere with operation. Contact your Welch Allyn distributor for information about cable replacement. Cable replacement instructions on page 8–2. Examining the Cordless Scanner and Cordless Base Housings Routinely examine the Cordless Scanner and Cordless Base housings for signs of damage. A damaged housing may cause the internal components to move and may result in a malfunctioning unit. Care and Handling of the Battery Pack Proper handling of the batteries while recharging extends the useful life of the batteries. New battery packs are shipped uncharged. In order to break in the new battery, we suggest that you fully charge and discharge the packs approximately two to four times so they can reach their full rated capacity. If the battery pack is left plugged in for extended periods of time (for instance, several weeks) the contacts between the prongs may become dirty, causing charging problems. Clean the prongs with a cotton swab and rubbing alcohol to remove any accumulation of dirt.

!

Warning:

Do not submerge the Cordless Scanner or the Cordless Base in water. Their housings are not water–tight. Do not use abrasive wipers or tissues on the scan window: abrasive wipers may scratch the window. Never use solvents (alcohol or acetone) on the housings or the window: solvents may damage the finish or the window. Do not open the Cordless Scanner or the Cordless Base. There are no serviceable parts inside.

Cordless System Manual

8–1

Page 98

Replacing the Interface Cable The standard host interface cable is attached to the Cordless Base with a 15–pin D–type receptacle connector. Tighten the holding screws to properly seat the interface connector. The cable is designed to be field replaceable. Auxiliary Port cables use a 10-position modular plug. To remove the Aux Port cable, depress the dimple located on the bottom of the Base unit underneath the Aux Port and pull the cable from the unit. Notes: • Order replacement cables from Welch Allyn or from an authorized distributor. • When ordering a replacement cable, specify the cable part number of the original interface cable. Recharging and Replacing the Cordless Scanner’s Battery Pack When the battery pack needs to be recharged, the yellow LED on top of the scanner pulses in short, continuous blinks and the scanner won’t beep when you pull the trigger. Follow the instructions below to recharge and replace the Cordless Scanner battery pack.

➊ Detach the battery pack from

Yellow LED the bottom of the Cordless Scanner (see Figure at right).

➋ In North America, plug the battery pack directly into any common 120 Volt outlet.

➌ To charge more than one battery pack (or to charge the pack for all other countries), use the Charge Strip (available as an accessory).

Press Release Buttons (2 Places)

The LED on the bottom of the battery pack is red when the unit is charging; it shows green when it is fully charged and ready to use. (See Battery Pack Specifications, page 7–4 for charging time and expected hours of operation.)

➍ After the battery pack is fully charged, attach to the Cordless Scanner by pressing the pack firmly (align the prongs on the pack with the mating receptacles) in the base of the scanner until the release buttons click, holding the pack firmly in place.

➎ If the scanner wasn’t previously associated to a base, scan the Association Bar Code on the top of the Base. If the scanner was previously associated to a base, it will automatically re-associate. (The association process takes about ten seconds.)

8–2

Cordless System Manual

Page 99

To Reset Factory Settings If you are unsure of the programming options that have been set up in your Cordless System, or you’ve changed some options and now want the factory settings restored, refer to Main Menu Selections in Section 2 and scan the Factory Default Settings bar code.

Troubleshooting The Cordless System automatically performs self-tests whenever you turn it on. If your Cordless Scanner or Cordless Base is not functioning properly, review the following Troubleshooting Guide to isolate the problem. Troubleshooting Guide Is the power on? Is the Scanner’s red illuminated beam on? If the red scan beam on the Cordless Scanner isn’t illuminated, check that:

➊ the battery pack is connected properly to the Cordless Scanner. ➋ the battery pack is not low on power (check the low battery LED).

Is the Cordless System having trouble reading your bar codes? If the Cordless System isn’t reading bar codes well, check that:

➊ ➋ ➌ ➍ the bar codes aren’t smeared, rough, scratched, or exhibiting voids. the bar codes aren’t coated with frost or water droplets on the surface. the bar codes are enabled (see Section 5, Symbology Menu). the Cordless Scanner window is clean.

Is the bar code displayed but not “entered”? The bar code is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return key or the Tab key, for example). You need to program a suffix. Programming a suffix enables the Cordless System to output the scanned bar code plus the key you need (such as a “CR,” carriage return) to enter the bar code into your application. (See Suffix Selection in Section 4, Application Work Group Menu.)

Cordless System Manual

8–3

Page 100

Does the Cordless System read your bar code incorrectly? If the Cordless System reads a bar code (one beep for a good read), but the bar code is not displayed correctly on the host screen:

➊ The Cordless System may not be programmed for the appropriate terminal interface.

Example: You scan “12345” and the host displays “@es%.” Reprogram the Cordless System with the correct “Plug and Play” or Terminal Selection bar code (see Section 1).

➋ The Cordless System may not be programmed to output your bar code properly.

Example: You scan “12345” and the host displays “A12345B.” Reprogram the Cordless System with the proper Symbology selections (see Section 5, Symbology Menu).

The Cordless System won’t read your bar code at all? If the Cordless System will not read your bar code:

➊ Try scanning the Sample Bar Codes (found on the back cover of the System Manual). If the Cordless System reads the Sample Bar Codes, check that your bar code is readable. (See “Is the Cordless System having trouble reading your bar codes” on the previous page.) Verify that your bar code symbology is enabled. (See Sections 5, Symbology Menu.) If the Cordless System does not read the Sample Bar Codes either, continue to #2, below...

➋ If the Cordless System won’t read the Sample Bar Codes either: Verify that the bar code symbologies are enabled. (See Sections 5, Symbology Menu.) Scan the “Default All... ” bar code on each symbology menu page in Section 5 to enable most symbologies.

8–4

Cordless System Manual