The text of a manual · part 11 of 12
Cordless System Manual: SCANTEAM 2070 Base, SCANTEAM 3470 CCD, SCANTEAM 5770 Laser, pages 101 to 110
Pages 101 to 110 of 112
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST3470
Page 101
Section 9
Customer Service
Obtaining Factory Service Welch Allyn provides service for all its products through a service center located at its manufacturing facilities in Skaneateles, New York. To obtain warranty or non–warranty service, return the unit to Welch Allyn (postage paid) with a copy of the dated purchase record attached. In the United States, please contact the Welch Allyn Product Service Department at the address/telephone number listed below to obtain a Return Material Authorization number (RMA #).
Welch Allyn, Inc. Data Collection Division Product Service Department 4619 Jordan Road P.O. Box 187 Skaneateles Falls, New York 13153–0187
Product Service Department Telephone: (315) 685–4278 or 685–4360 Fax: (315) 685–4156 For service in Europe, please contact your Welch Allyn representative (at appropriate address below) or your local distributor. Welch Allyn, Ltd. Block 1, Bracken Business Park Sandyford Co Dublin Ireland Telephone: Int+353–1–216–0070 Fax: Int+353–1–295–6353 U. K. Office Dallam Court Dallam Lane Warrington, Cheshire WA2 7LT England Telephone: Int+44 1925 240055 Fax: Int+44 1925 631280 For service in Asia, please contact your Welch Allyn representative (at address below) or your local distributor. Welch Allyn, Hong Kong Office 10/F Tung Sun Commercial Centre 194–200 Lockhart Road Wanchai, Hong Kong Telephone: Int+852–2511–3050 or 2511–3132 Fax: Int+852–2511–3557 Cordless System Manual
9–1
Page 102
Technical Support If, after reviewing the Troubleshooting Section, you still need assistance installing or troubleshooting your Cordless System, please call your Distributor or the nearest Welch Allyn technical support office.
North America: Telephone: (315) 685–2476 (8 a.m. to 5 p.m. EST) Fax number: (315) 685–4960 Email: dcd_techsupt@welchallyn.com Europe: United Kingdom Telephone: Int+44 1925 240055 Ireland Telephone: Int+353–1–216–0070 Asia: Telephone: Int+852–2511–3050 or 2511–3132 Limited Warranty Welch Allyn, Inc., hereby warrants its products to be functional and free from manufacturing defects at the time of delivery. Welch Allyn, Inc. further warrants that it will replace or repair, at its option, any unit that fails to perform according to Welch Allyn’s published specifications during a specified duration (see chart below) from the time of shipment by Welch Allyn, Inc. to the user at the time it is purchased from any of Welch Allyn Inc.’s Authorized Distributors. Any attempt on the part of the user to disassemble or service the equipment shall void the warranty. The warranty does not apply to product which have been damaged by improper handling, shipping, or misuse. The warranty does not apply, if, in the sole opinion of Welch Allyn, Inc., the unit has been damaged by accident, misuse, neglect, improper shipping and handling. Since the unit is sensitive to static, the responsibility to protect it from static damage is solely that of the user. The warranty is valid only if the unit has not been tampered with or serviced by any party unauthorized by Welch Allyn, Inc. as a repair facility. THE WARRANTIES SET FORTH HEREIN ARE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE BUYER ACKNOWLEDGES THAT NO OTHER REPRESENTATIONS WERE MADE OR RELIED UPON WITH RESPECT TO THE QUALITY AND FUNCTION OF THE CORDLESS SYSTEM HEREIN SOLD. In no event shall Welch Allyn, Inc. or its resellers be liable for any loss, inconvenience or damage whether direct, incidental, consequential or otherwise, and whether caused by negligence or other fault resulting from the breach of any express warranty except as set forth herein. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state or country to country. Limited Warranty Durations Cordless CCD Scanner
Cordless Laser Scanner
Cordless Base Unit
Nicad Battery
NiMH Battery
3 Years
3 Years
3 Years
1 Year
1 Year
9–2
Cordless System Manual
Page 103
Cordless System Manual
9–3
Page 104
9–4
Cordless System Manual
Page 105
Quick Start and Interface Menu Defaults The following chart lists the factory default Quick Start and Interface Menu settings (indicated by a “✱” on the programming menu pages).
Default Setting
Page Reference
United States
Page 2–6
Keyboard Layout
Layout 1 (Telephone)
Page 2–7
Keyboard Style
Regular
Page 2–8
Keyboard Style Modifiers
Control + ASCII Mode Off Turbo Mode Off Numeric Keypad Mode Off Auto Direct Connect Off
Page 2–9 Page 2–9 Page 2–9 Page 2–9
Output Delays Intercharacter Delay
00 (x5mS)
Page 2–10
Interfunction Delay
00 (x5mS)
Page 2–10
Intermessage Delay
00 (x5mS)
Page 2–10
25 ips Black High
Page 2–11 Page 2–11
Parameter Name Country Code Selections Keyboard Country
Keyboard & Delays Selections
Wand Emulation Selections Transmission Rate Output Polarity
Communications Menu Defaults The following chart lists the factory default Communications Menu settings (indicated by a “✱” on the programming menu pages).
Default Setting
Page Reference
Baud Rate
38400
Page 3–2
Parity
None
Page 3–3
Parameter Name Host Port Communications
Word Length Data Bits
8
Page 3–3
Word Length Stop Bits
1
Page 3–4
Serial Wedge Output
None (RS-232)
Page 3–4
Hardware Flow Control
Off
Page 3–4
Host ACK
Off
Page 3–5
Cordless System Manual
Page 106
Communications Menu Defaults The following chart lists the factory default Communications Menu settings (indicated by a “✱” on the programming menu pages).
Parameter Name
Default Setting
Page Reference
Auxiliary Port Communications Baud Rate
38400
Page 3–6
Parity
None
Page 3–7
Word Length Data Bits
8
Page 3–7
Word Length Stop Bits
1
Page 3–8
Protocol
Record
Page 3–8
Aux Port I.D. Transmit
Off
Page 3–8
Hardware Flow Control Data Character SOR (Start of Record)
Off
Page 3–9
00 (NUL)
Page 3–9
EOR (End of Record)
0D (CR)
Page 3–9
SOB (Start of Block)
00 (NUL)
Page 3–9
EOB (End of Block)
04 (EOT)
Page 3–9
Aux Prefix / Suffix Aux Prefix (Incoming Data)
None
Page 3–10
Aux Suffix (Incoming Data)
None
Page 3–10
Aux Prefix (Outgoing Data)
None
Page 3–10
Aux Suffix (Outgoing Data)
CR
Page 3–10
On
Page 3–14
Aux Require Data Format?
Don’t Require
Page 3–14
Aux Data Format
None
Page 3–14
Aux Data Formatter Aux Data Formatter
Cordless System Manual
Page 107
Application Work Groups Menu Defaults The following chart lists the factory default Application Work Groups Menu settings (indicated by a “✱” on the programming menu pages).
Parameter Name
Default Setting
Page Reference
Output Selections (User Feedback) Application Work Goup
Group 0
Page 4–2
Beeper Volume
High
Page 4–3
Decode Beep
Off
Page 4–3
Scanner Voting
Off
Page 4–4
Laser Marker Beam
Off
Page 4–4
AIM I.D. Transmit Welch Allyn Code I.D. Transmit
Off Off
Page 4–5 Page 4–5
Prefix
None
Page 4–7
Suffix
CR
Page 4–7
Prefix / Suffix Selection
Data Formatter Selections Data Formatter
On
Page 4–11
Require Data Format?
Don’t Require
Page 4–11
Data Format
None
Page 4–11
Symbology Menu Defaults – Industrial The following chart lists the factory default Industrial Symbology Menu settings (indicated by a “✱” on the programming menu pages).
Parameter Name
Default Setting
Page Reference
Codabar Selection Codabar
On
Page 5–2
Start / Stop Characters
Don’t Transmit
Page 5–2
Message Length
Min = 2, Max = 60
Page 5–2
Check Character
Don’t Validate
Page 5–3
Check Character
Don’t Transmit
Page 5–3
Concatenation
On
Page 5–3
Concatenation
Don’t Require
Page 5–3
Cordless System Manual
Page 108
Symbology Menu Defaults – Industrial The following chart lists the factory default Industrial Symbology Menu settings (indicated by a “✱” on the programming menu pages).
Default Setting
Page Reference
Code 39
On
Page 5–4
Start / Stop Characters Message Length
Don’t Transmit Min = 0, Max = 48
Page 5–4 Page 5–4
Check Character
Don’t Validate
Page 5–4
Check Character
Don’t Transmit
Page 5–4
Full ASCII Append
On Off
Page 5–5 Page 5–5
Code 93
On
Page 5–6
Message Length
Min = 0, Max = 80
Page 5–6
On
Page 5–7
Parameter Name Code 39 Selection
Code 93 Selection
Interleaved 2 of 5 Selection Interleaved 2 of 5 Message Length
Min = 4, Max = 80
Page 5–7
Check Digit
Don’t Validate
Page 5–7
Check Digit
Don’t Transmit
Page 5–7
Lengths of 6, 14 or 16
Off
Page 5–7
Code 2 of 5
On
Page 5–8
Message Length
Min = 4, Max = 48
Page 5–8
Code 2 of 5 Selection
Matrix 2 of 5 Selection Matrix 2 of 5
On
Page 5–8
Message Length
Min = 4, Max = 80
Page 5–8
On
Page 5–9
Check Digits Required
2 Check Digits
Page 5–9
Message Length
Min = 4, Max = 80
Page 5–9
Code 128
On
Page 5–9
Message Length
Min = 0, Max = 80
Page 5–9
Code 11 Selection Code 11
Code 128 Selection
Cordless System Manual
Page 109
Symbology Menu Defaults – Retail The following chart lists the factory default Retail Symbology Menu settings (indicated by a “✱” on the programming menu pages).
Default Setting
Page Reference
EAN / JAN 8
On
Page 5–10
EAN / JAN 13
On
Page 5–10
Check Digit
Transmit
Page 5–10
UPC A
On
Page 5–11
Check Digit
Transmit
Page 5–11
Number System
Transmit
Page 5–11
UPC E0
On
Page 5–12
Check Digit
Transmit
Page 5–12
Number System
Transmit
Page 5–12
Version E Expand
Don’t Expand
Page 5–12
Off
Page 5–12
EAN / UPC Addenda
Don’t Require
Page 5–13
EAN Two Digit Addenda
Off
Page 5–13
Parameter Name EAN / JAN 8 / 13 Selection
UPC A Selection
UPC E0 Selection
UPC E1 Selection UPC E1
EAN / UPC Addenda Selection
EAN Five Digit Addenda
Off
Page 5–13
UPC Two Digit Addenda
Off
Page 5–13
UPC Five Digit Addenda
Off
Page 5–13
Cordless System Manual
Page 110
This programming chart contains alphanumeric bar codes used for setting additional programming options, such as the digits representing Symbology Message Length. Scan the programming selection bar code first, and then scan the bar code(s) representing the option you want to set. Programming selections that require options to be set are marked with a ] symbol.
0
1
2
3
4
5
6
7
8