Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 9 of 12

Cordless System Manual: SCANTEAM 2070 Base, SCANTEAM 3470 CCD, SCANTEAM 5770 Laser, pages 81 to 90

Pages 81 to 90 of 112

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP ST3470

Page 81

Supported Interface Keys Supported Interface Keys

IBM, Telex (102)*

Telex (88)**

DEC VT

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

Reserved Enter F11 F12 F13 F14 F15 New Line F16 F17 F18 Tab/Field Forward Delete Field Exit Insert Clear Error Reset Home Print Back Space Back Tab F19 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

Reserved Enter PF10 PF11 PF12 Reserved Reserved New Line Field Forward Field Forward Reserved Field Forward Delete New Line Insert Erase Error Reset Reserved Print Back Space Back Field Reserved PF1 PF2 PF3 PF4 PF5 PF6 PF7 PF8 PF9 Home

Reserved Enter PF1 PF2 PF3 PF11 PF12 New Line PF4 TAB F13 F14 Remove New Line Insert Here Cursor Up Cursor Left Cursor Down Cursor Right Delete Print F15 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

* Terminal IDs 06, 07, and 08, Telex (all models) with 102 key keyboards ** Memorex Telex with 88 key keyboards *** DEC VT 220/320/340/420

Cordless System Manual

6–3

Page 82

Supported Interface Keys Esprit 200, 400 Supported Interface Keys ANSI

Esprit 200, 400 ASCII

Esprit 200, 400 PC

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab N/A New Line N/A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab Delete New Line Insert Escape F11 Home Print Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

6–4

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab N/A New Line N/A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

Cordless System Manual

Page 83

Supported Interface Keys Supported Interface Keys

Bull BDS–7 (Honeywell HDS–7)

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

Reserved Transmit Reserved Reserved Reserved Backtab Reserved Carriage Return Back Space Tab F11 F12 Delete Character Carriage Return Insert Clear Error Reset Home Delete Line Erase EOP Erase EOF Insert Line F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

Cordless System Manual

6–5

Page 84

6–6

Cordless System Manual

Page 85

Section 7

Product Specifications

SCANTEAM 2070 Cordless Base Product Specifications Parameter

Specification

Dimensions Height Width Length

1.4 inches (3.6 cm) 4.0 inches (10.2 cm) 4.5 inches (11.5 cm)

Weight

7.25 ounces (206 g) without cable

LED Indicators

One (1)

Beeper

None

Operating Voltage

+4.0 to 14.0 VDC

Power Consumption

325 mA (typical) @ 5 VDC

Noise Immunity

100 mV peak to peak

Temperature Ranges

Operating: –4° F to +122° F (–20° C to +50° C) Storage: –40° F to +158° F (–40° C to +70° C)

Humidity

0 to 95% relative humidity (non-condensing)

Housing Material

GE Cycloloy C2800 or C2950 Standard Flow

Sealing

IP 53 (Water and Dust Resistant)

Mechanical Shock

26 drops from 4 feet (1.2 m) to concrete

ESD Sensitivity

15 kV to any external surface

Reliability

MTBF = 50,000 hours (ground benign)

Radio Specifications Parameter

Specification

Frequency

2.400 to 2.4835 Ghz (ISM Band) Frequency Hopping Carrier

Data Rates

1 Mbps

Cordless System Manual

7–1

Page 86

SCANTEAM 3470 Cordless CCD Scanner Product Specifications Parameter

Specification

Dimensions Height Width Length

8.3 inches (21 cm) (with battery) 3.1 inches (7.8 cm) 4.7 inches (11.9 cm)

Weight

18 ounces (510 g) with battery pack

Light Source

630 to 660 nm Visible Red Light Emitting Diodes (LED)

Print Contrast

Minimum Reflective Difference = 37.5%

Scan Rate

113 scans per second (CCD scan engine)

LED Indicators

Two (2)

Beeper

Yes (volume programmable)

Skew Angle

±30 degrees (from perpendicular)

Pitch Angle

±7 degrees (left/right from perpendicular)

Operating Voltage

+4.3 to 6.0 VDC

Power Consumption

Operating: 400 mA (maximum) @ 4.8 VDC 210 mA (typical) while scanning Standby: 12 mA

Ambient Light

Total darkness to 100,000 Lux (sunlight)

Noise Immunity

100 mV peak to peak

Temperature Ranges

Operating: +32° F to +122° F (–0° C to +50° C) Storage: –22° F to +158° F (–30° C to +70° C)

Humidity

5 to 95% relative humidity (non-condensing)

Altitude

Sea level to 9,900 feet (3000 meters)

Housing Material

GE Cycloloy C2800 or C2950 Standard Flow

Sealing

IP 54 (Water and Dust Resistant)

Mechanical Shock

26 drops from 6 feet (1.8 m) to concrete

ESD Sensitivity

15 kV to any external surface

Reliability

MTBF = TBD hours (ground benign)

7–2

Cordless System Manual

Page 87

SCANTEAM 5770 Cordless Laser Scanner Product Specifications Parameter

Specification

Dimensions Height Width Length

8.3 inches (21 cm) (with battery) 3.1 inches (7.8 cm) 4.7 inches (11.9 cm)

Weight

18 ounces (510 g) with battery pack

Light Source

630 to 670 nm Visible Laser Diode (VLD)

Scan Rate

34 scans per second (laser scan engine)

Print Contrast

Minimum Reflective Difference = 40%

LED Indicators

Two (2)

Beeper

Yes (volume programmable)

Skew Angle

±65 degrees (from perpendicular): 5770/STD ±60 degrees (from perpendicular): 5770/LR

Pitch Angle

±55 degrees (left/right from perpendicular): 5770/STD ±65 degrees (left/right from perpendicular): 5770/LR

Operating Voltage

+4.3 to 6.0 VDC

Power Consumption

Operating: 400 mA (maximum) @ 4.8 VDC 210 mA (typical) while scanning Standby: 12 mA

Ambient Light

Total darkness to 100,000 Lux (sunlight)

Noise Immunity

100 mV peak to peak

Temperature Ranges

Operating: –4° F to +122° F (–20° C to +50° C) Storage: –22° F to +158° F (–30° C to +70° C)

Humidity

5 to 95% relative humidity (non-condensing)

Altitude

Sea level to 9,900 feet (3000 meters)

Housing Material

GE Cycloloy C2800 or C2950 Standard Flow

Sealing

IP 54 (Water and Dust Resistant)

Mechanical Shock

26 drops from 6 feet (1.8 m) to concrete

ESD Sensitivity

15 kV to any external surface

Reliability

MTBF = TBD hours (ground benign)

Cordless System Manual

7–3

Page 88

Battery Specifications The battery packs are designed with an integrated charging circuitry to allow them to be plugged directly into any common 120 Volt outlet [. Battery packs have an LED indicator to signal charging and fully-charged conditions. In order to break in the new battery, we suggest that you fully charge and discharge the packs approximately two to four times so they can reach their full-rated capacity. Parameter

Specification

NiCad (Nickel Cadmium) Capacity Number of Scans (between charges) Expected Hours of Operation ] Charge Time

120 Volt/60 hz

240 Volt

600 mAh 7,200 12 Hours 8 Hours

600 mAh 7,200 12 Hours 4 Hours @ 60 hz 5 Hours @ 50 hz

NiMH (Nickel Metal Hydride) Capacity Number of Scans (between charges) Expected Hours of Operation ] Charge Time for 800 mA/h

120 Volt/60 hz

240 Volt

1200 mAh 14,000 20 Hours 4 Hours

1200 mAh 14,000 20 Hours 4 Hours

Battery Charging (Input) Voltage

85 to 264 VAC @ 47 to 63 hz

[ ]

North America only. All other countries require a Charge Strip (available as an accessory). Usage Model = one (1) scan every five (5) seconds.

NiCad Battery Pack: Recommended Storage [[ Storage Time

Storage Temperature

Up to 6 months

–20° C to 45° C (–4° F to 113° F)

Up to 2 years

–20° C to 35° C ( –4° F to 95° F)

NiMH Battery Pack: Recommended Storage [[ Storage Time

Storage Temperature

Up to a month

–20° C to 55° C (–4° F to 131° F)

Up to 3 months

–20° C to 45° C (–4° F to 113° F)

Up to a year

–20° C to 35° C ( –4° F to 95° F)

Longer than a year

+10° C to 25° C (50° F to 77° F)

[[ When storing battery packs for longer than 6 months, recharge at least once a year (once every 6 months if possible) to prevent self–discharge from causing a drop in battery performance or electrolyte leakage.

7–4

Cordless System Manual

Page 89

Regulatory and Safety Agency Approvals Parameter Electromagnetic Emissions/Immunity U.S.A. Canada Europe Others:

Specification

FCC Part 15, Class B – Verified SOR 88/475, Class B – Verified EN 55022 (CISPR22) Class B EN 61000–3–2 & –3 ETS 300 826 Type Certified EMC 89/336/EEC EN 50082–1:1992 IEC 801–2:1991 IEC 801–3:1984 IEC 801–4:1988

Safety U.S.A. Canada Europe Mexico

UL Listed, C22.2 No. 950 / UL 1950 cUL Listed TÜV Rheinland GS Licensed, EN 60950 (IEC 950) NYCE Certified, NOM 19

RF Approvals U.S.A. Canada Europe Mexico

FCC Part 15.249 Certified RSS 210 Certified ETS 300 328 Certified NOM–EM–121–SCT1–1994 Certified

Patents

TBD

Cordless System Manual

7–5

Page 90

Cordless Base Back View

Keyboard/Terminal and RS-232 Connector (Host Port)

External Power Connector

Aux RS-232, Service Port, and Wand Emulation Output Connector

Auxiliary RS-232 / Wand Emulation Connector The auxiliary RS-232 / scanner connector supports wand emulation or the attachment of an RS-232 input device. The Aux port is compatible with all Welch Allyn contact and non-contact bar code scanners, including bar code contact wands, lasers, and CCDs which operate in RS-232 (TTL and True). Aux RS-232 Connector: 10 Pin Modular Receptacle Pin

Signal Name

Description

1

GND

Power/Signal Ground

2

TXD

Transmit Data (output)

3

RXD

Receive Data (input)

4

RTS

Request to Send (output)

5

CTS

Clear to Send (input)

6

VCC

5 Volt DC Power Out

7

WANDEM

TTL Wand Data (output)

8

VIN AUX

Power into Aux

9

VIN FLASH

12V Flash Radio (input)

10

N/C

No connection

1

10

Communication Parameters For Aux RS-232 Port Start Bit Data Bits Stop Bits

1 7 or 8 1 or 2

Parity

None, Mark, Space, Odd, or Even

Baud Rate

300, 600, 1200, 2400, 4800, 9600, 19200, 38400

Wand Emulation Mode When the Base is configured for Wand Emulation (ID 61 or 64), the Aux port will output wandem data on Pin 7 at the selected rates/polarity described on page 2–11 or in the Plug and Play section, page 2–2.

7–6

Cordless System Manual