The text of a manual · part 2 of 3
SCANTEAM PDF417 Programming Menu, pages 11 to 20
Pages 11 to 20 of 30
The original document is the PDF (141 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the HHP ST3400
Page 11
TRIGGER
SCANTEAM PDF417 Programming Menu
USE THIS PAGE To default this page to asterisked (*) values. To set the trigger mode to autotrigger. To set the trigger mode to manual trigger.
selections scan
AUTOTRIGGER ENABLE
I*
MANUAL TRIGGER ENABLE (2) (3)
II*
(For both hardware and serial triggering)
scan
ENTER
Notes: (1) * Denotes DEFAULT setting. (2) SCANTEAM 3000 and 3400 must be in manual trigger mode to use switched power option. (3) SCANTEAM 3000 and 3400 units that have a trigger default to Manual Trigger Enable. scan
DEFAULT scan
ESCAPE scan
EXIT
9
Page 12
SCANTEAM PDF417 Information/Examples
PREFIX/SUFFIX Prefix / Suffix
The scanner will transmit the decoded message after every successful bar code read. You have the option of adding characters before (prefix) and after (suffix) the bar code: Transmitted data frame –>
Prefix
Bar Code Message
Suffix
Characters for the prefix and suffix are selected by their hexadecimal ASCII value, up to 8 characters each. In addition, special characters are available for code identification and for error detection. Programming prefix/suffixes is flexible, allowing creative framing possibilities. These prefix/suffixes apply to all messages regardless of the symbology, and cannot be assigned for a specific symbology. The special characters for Code ID will change to indicate the decoded symbology. Note: HEX–ASCII and Symbology charts are shown below the Prefix/Suffix Examples. Special Characters and their explanations are on following (menu) page. Prefix/Suffix Examples: 1. The suffix defaults to a carriage return plus line feed: Bar Code Message <CR> <LF> If no suffix is desired, scan:
ENTER, II, EXIT
To clear a prefix, scan:
ENTER, I, EXIT
Where: ENTER (Prefix/Suffix) enters programming mode. II selects suffix programming and clears current suffix. EXIT saves changes and exits programming mode. 2. To frame a message with <STX> (start of transmission) and <ETX> (end of transmission): <STX> Bar Code Message <ETX> First program the prefix, then the suffix, by scanning:
ENTER, I, 0, 2, II, 0, 3, EXIT
Where: ENTER (Prefix/Suffix) enters programming mode. I selects prefix programming and clears current prefix. 02 represents the hexadecimal ASCII value for the <STX> character. II selects suffix programming and clears current suffix. 03 represents the hexadecimal ASCII value for the <ETX> character. EXIT saves changes and exits programming mode. HEX – ASCII CHART NUL 00 SOH 01 STX 02 ETX 03 EOT 04 ENQ 05 ACK 06 BEL 07 BS 08 HT 09 LF 0A VT 0B FF 0C CR 0D SO 0E SI 0F
SP 20 ! 21 ” 22 # 23 $ 24 % 25 & 26 ’ 27 ( 28 ) 29 * 2A + 2B , 2C – 2D . 2E / 2F
DLE 10 DC1 11 DC2 12 DC3 13 DC4 14 NAK 15 SYN 16 ETB 17 CAN 18 EM 19 SUB 1A ESC 1B FS 1C GS 1D RS 1E US 1F
0 1 2 3 4 5 6 7 8 9 : ; < = > ?
30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
@ 40 A 41 B 42 C 43 D 44 E 45 F 46 G 47 H 48 I 49 J 4A K 4B L 4C M 4D N 4E O 4F
P Q R S T U V W X Y Z [ \ ] ^ _
Code ID
50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
‘ a b c d e f g h i j k l m n o
70 p q 71 r 72 s 73 t 74 u 75 v 76 w 77 x 78 y 79 z 7A { 7B | 7C } 7D ~ 7E DEL 7F
60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F
SYMBOLOGY CHART Symbology
Code ID
ASCII
Symbology
ASCII
Symbology
Codabar a
61
Industrial 2 of 5 f
66
Code 49 l
6C
Code 39 b
62
MSI code g
67
Matrix 2 of 5 m
6D
UPC c
63
Code 11 h
68
Plessey code n
6E
EAN d
64
Code 93 i
69
Code 16K o
6F
Interleaved 2 of 5 e
65
Code 128 j
6A
PDF417 r
72
10
Code ID ASCII
Page 13
SCANTEAM PDF417 Programming Menu
PREFIX/SUFFIX (RS-232)
USE THIS PAGE To default this page to asterisked (*) values. To program prefix/suffix parameters.
selections scan parameters
PREFIX
I
Up to EIGHT hexadecimal pairs, 00 through FF *None
SUFFIX
II
Up to EIGHT hexadecimal pairs, 00 through FF *<CR> <LF> scan
ENTER
Notes: (1) DEFAULT is NO prefix and <CR> <LF> suffix.
Special Characters Hex Result Character 80
81
85
Insert Code ID The 80 hex will be replaced by a single character identifying the decoded barcode symbology. See the Symbology Chart, facing page. Insert AIM Symbology ID and Modifier The 81 hex will be replaced by a three character string: ]CM Where: ] is the symbology ID flag character C is the symbology ID character M is the modifier character See AIM Guidelines on Symbology Identifiers for more information. Insert LRC Checksum as two printable hexadecimal characters plus a space. When placed at the end of a transmitted message, the LRC checksum provides a modest amount of error detection. The checksum is computed as the Exclusive-Or of every transmitted character, after being initialized to zero. The LRC checksum can have any value 00 through FF hexadecimal, but not all characters in this range are printable. This option causes the LRC checksum to be transmitted as three characters; two hexadecimal numbers plus a space.
scan
DEFAULT scan
ESCAPE
86
Insert LRC Checksum as a single byte A single character is transmitted having a value 00 through FF hexadecimal.
scan
87 XX
Set LRC Checksum = XX (hexadecimal) For initializing the checksum to some value other than zero, XX can be any value 00 through FF hexadecimal. This option is set as the first prefix.
EXIT
11
Page 14
SCANTEAM PDF417 Information/Examples
CODE SELECTION I (INDUSTRIAL)
Note: Welch Allyn PDF Capable readers can autodiscriminate between 7 Symbologies. For maximum data security, disable the codes not used.
Symbology Option
Explanation
Codabar
S/S Xmit
Data in a Codabar symbol is framed by a start and a stop character. Since they are not considered part of the message, they are not ordinarily transmitted.
Check Char Req’d
For applications requiring enhanced security, a check character may be used. When enabled, the reader will assume that the last character is a check character, and will use it to verify the accuracy of the scanned data. If no error is detected, the data will be transmitted.
Xmit Check Char
When required, the check character will be verified, but will not normally be transmitted. Enable this option to transmit the checksum, when planning to verify transmitted data.
Concatenation
Codabar provides an option for concatenating messages of adjacent symbols. The reader can distinguish those messages which are concatenated from those that are not. Select “NO” to prevent concatenation.
Code 39
Concatenation Req’d With this option enabled the reader only responds to concatenated symbols. If a particular application will always use concatenation with Codabar, then this option is recommended. S/S Xmit Data in a Code 39 Symbol is framed by a start and a stop character. Since they are not considered part of the message they are not ordinarily transmitted. Check Char Req’d
For applications requiring enhanced security, a check character can be used. When enabled, the reader will assume that the last character is a check character, and will use it to verify the accuracy of the scanned data. If no error is detected, the data will be transmitted.
Xmit Check Char
When required, the check character will be verified, but will not normally be transmitted. Enable this option to transmit the checksum, when planning to verify transmitted data.
Full ASCII
The Code 39 specification provides a means of encoding the full ASCII set of characters by using two-character sequences made up of one of the four Code 39 characters ($ + % /) followed by one of the 26 letters as shown in the Full ASCII Code 39 chart (on page 14). The reader cannot distinguish Code 39 labels encoded in full ASCII mode from those encoded in standard mode. Use this option to direct the decoder which mode to assume.
Append Option
The Code 39 specification provides a means of appending data messages. If the first data character of a Code 39 symbol is a SPACE, then data following the SPACE can be appended to a storage buffer. PDF Capable readers do not have an append buffer; therefore this function is not available. When append option is selected, any leading SPACE is removed from the transmitted message. For applications requiring enhanced data security, a check character can be used. When enabled, the reader will assume that the last digit is a check digit, and will use it to verify the accuracy of the scanned data. If no errors are detected the data will be transmitted.
Interleaved Check Digit Req’d 2 of 5
Xmit Check Digit
12
When required, the check digit will be verified, but will not normally be transmitted. Enable this option to transmit the check digit, when planning to verify the transmitted data.
Page 15
CODE
SCANTEAM PDF417 Programming Menu
SELECTION I (INDUSTRIAL)
USE THIS PAGE To select the pre-programmed asterisked (*) values by scanning DEFAULT symbol. To enable or disable listed code selections.
selections scan
CODABAR
I
ID = a (HEX 61)
CODE 39
II
ID = b (HEX 62)
INTERLEAVED 2 OF 5
III
ID = j (HEX 6A)
IV scan
Enable scan scan
*Yes/No
S/S Xmit
A
Yes/No*
Check Char. Req’d
Yes/No*
Xmit Check Char.
B C
*Yes/No
Concatenation
D E
Yes/No*
Min Length
F
*01–Max
Max Length
G
Min–60*
A
Yes/No*
Check Char. Req’d
B
Yes/No*
Xmit Check Char.
C
Yes/No*
Full ASCII
D
*Yes/No
Append Option
E
Yes/No*
Min Length
F
*01–Max
Max Length
G
Min–48*
Enable
ENTER
Yes/No*
Concatenation Req’d
S/S Xmit
ID = e (HEX 65)
CODE 128 parameters
*Yes/No
Enable scan
DEFAULT
*Yes/No
Check Digit Req’d
A
Yes/No*
Xmit Check Digit
B
Yes/No*
Min Length (2)
C
02–Max
Max Length
D
Min–80*
Min Length
A
*01–Max
Max Length
B
Min–80*
Enable
*Yes/No
Notes: (1) * Denotes DEFAULT settings. (2) The DEFAULT minimum length for Interleaved 2 of 5 codes is 4 characters.
scan
ESCAPE scan
EXIT
13
Page 16
SCANTEAM PDF417 Information/Examples
CODE SELECTION II (RETAIL)
Note: Welch Allyn PDF Capable readers can autodiscriminate between 7 Symbologies. For maximum data security, disable the codes not used.
Symbology Option
Explanation
UPC
Version A
Standard Version, used to encode a 12 digit number; the first digit is the number system character, the next ten are data characters, the last is a check character.
Version D
This Variable Length version is not supported by the PDF Capable reader.
Version E0
The Zero Suppression version for number system 0 compacts UPC data into six digits plus a check character.
Version E1
No longer supported by the UPC specification because of its similarity to EAN 13, this Zero Suppression version compacts UPC number system 1 data into six digits. The PDF Capable readers can be programmed to read UPC E1 as long as EAN 13 is disabled.
Check Digit Xmit
The check digit of a UPC symbol is normally transmitted, though the reader can be programmed to suppress the check digit.
Number System Xmit The number system character of a UPC symbol is normally transmitted, though the reader can be programmed to suppress the number system character.
EAN
Version E Expand
When this option is selected, the UPC E symbol is expanded into the standard 12 digit format.
Addenda
Two / five digit addendas are supported; it is recommended you leave them disabled unless they are specifically required. If an addenda will always be used it is recommended you enable the UPC and EAN ADDENDA REQUIRED Option. When enabled, symbols without the addenda will not read.
EAN / JAN 13
A superset of UPC, EAN 13 encodes a 13 digit number; 12 data digits and a check digit.
EAN / JAN 8
EAN encodes an 8 digit number; 7 data digits and a check digit.
Check Digit Xmit
The check digit of an EAN symbol is normally transmitted, though the reader can be programmed to suppress the check digit.
Addenda
Two and five digit addendas are supported; it is recommended you leave them disabled unless they are specifically required. If an addenda will always be used it is recommended you enable the UPC and EAN ADDENDA REQUIRED Option. When enabled, symbols without the addenda will not read.
FULL ASCII CODE 3 OF 9 CHART NUL %U SOH $A STX $B ETX $C EOT $D ENQ $E ACK $F BEL $G BS $H HT $I LF $J VT $K FF $L CR $M SO $N $O SI
14
DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
$P $Q $R $S $T $U $V $W $X $Y $Z %A %B %C %D %E
SP ! ” # $ % & ’ ( ) * + , – . /
SPACE /A /B /C /D /E /F /G /H /I /J /K /L – . /O
0 1 2 3 4 5 6 7 8 9 : ; < = > ?
0 1 2 3 4 5 6 7 8 9 /Z %F %G %H %I %J
@ A B C D E F G H I J K L M N O
%V A B C D E F G H I J K L M N O
P Q R S T U V W X Y Z [ \ ] ^ _
P Q R S T U V W X Y Z %K %L %M %N %0
‘ a b c d e f g h i j k l m n o
%W +A +B +C +D +E +F +G +H +I +J +K +L +M +N +O p +P q +Q r +R s +S t +T u +U +V v w +W x +X y +Y z +Z { %P | %Q } %R ~ %S DEL %T
Page 17
CODE
SCANTEAM PDF417 Programming Menu
SELECTION II (RETAIL)
USE THIS PAGE To select the pre-programmed asterisked (*) values by scanning DEFAULT symbol. To enable or disable listed code selections.
selections UPC scan
I
ID = c (HEX 63)
EAN
II
ID = d (HEX 64)
UPC & EAN ADDENDA REQ’D.
III parameters scan scan
Version A
A
*Yes/No
Version D (2) Version E0
B C
*Yes/No
Version E1
D
*Yes/No
Check Digit Xmit
E
*Yes/No
Number System Xmit
F
*Yes/No
Version E Expand
G
Yes/No*
2 Digit Addenda
H
Yes/No*
5 Digit Addenda
I
Yes/No*
EAN / JAN 13
A
*Yes/No
EAN / JAN 8
B
*Yes/No
Check Digit Xmit
C
*Yes/No
2 Digit Addenda
D
Yes/No*
5 Digit Addenda
E
Yes/No*
Enable
Notes: (1) * Denotes DEFAULT settings. (2) UPC Version D is not supported at this time.
No* scan
ENTER scan
DEFAULT
Yes/No* scan
ESCAPE scan
EXIT
15
Page 18
SCANTEAM PDF417 Information/Examples
CODE SELECTION III (STACKED)
Note: Welch Allyn PDF Capable readers can autodiscriminate between 7 Symbologies. For maximum data security, disable the codes not used.
Symbology Option
Explanation
PDF417
Up to 16 Macro PDF symbols encoding up to 13,000 characters of data can be combined in designated order and transmitted as a single data packet in the PDF417 readers. Disabling Macro PDF causes the data from every PDF417 symbol to be transmitted independently in the order scanned.
Macro PDF
Show Macro Control Enabling this feature causes Macro PDF Control Block Block contents to be included at the end of the encoded data except when all data messages have been successfully merged and are issued as a single data packet (see above). When enabled, the backslash “\” is used as an escape character and natural occurrences of “\” in data are replaced by “\\”. Show GLI Blocks
Enabling this feature causes GLI Commands to be issued where located within their encoded data sequences. When enabled, the “\” is used as an escape character and natural occurrences of “\” in data are replaced by “\\”.
One Pass
If this option is enabled, any partial PDF417 scan will be cleared from memory upon a TRIGGER OFF. Normally PDF scans are saved in memory until either a DECODE or a new PDF417 label is scanned. It is not always possible for the reader to know when a new label is introduced.
Notify When Certain
If this option is enabled, the reader sends out a message (ASCII decimal 23) to notify the host system that a successful PDF417 decode is certain; no more scanning is required. For Example: in a machine mount system, a host computer moves a PDF417 label back and forth in front of the PDF Capable reader until the ASCII decimal 23 is received. At that point scanning is completed, and the decoded message will follow.
When To Decode
The PDF Capable reader must temporarily halt scanning in order to perform PDF417 decoding. A refined algorithm automatically predicts when enough information has been scanned to insure a successful decode. If the scanned data contains many errors, though, decoding cannot succeed and more scanning is required. In a machine mount system with a predetermined scan cycle, it may be an advantage to use Trigger-Off Decoding. When this option is enabled, the reader will not attempt to decode PDF417 until a TRIGGER OFF. During the predetermined scanning time, the reader is sure to be collecting data. The When To Decode default for the SCANTEAM 3700 is set to decode PDF bar code data at Trigger Off to protect against multiple reads of the same code through a single scan. Trigger Off occurs with a change in state of the external or serial trigger or when scanning white in the Autotrigger mode.
Scan Diagnostics
16
Enabling Scan Diagnostics causes progress reports to be issued during PDF417 scanning. Interim reports are in the cryptic form: “21x07=115+032=147 129 C” which reports: (#Rows)x(#DataColumns)=(#DataWords)+(#CheckWords) =(Total) (#Read) (Grade) The first five parameters describe the symbol being scanned while the final two report on the progress made in scanning it. Enabling Scan Diagnostics also enables a prolonged delay before attempting an array decode, allowing results to accumulate over several scans of the symbol. Upon successful array decode, a final report is issued in the form: “003 Eras + 001 Errs = >143 A” which presents the results of the error correction calculations. No Read Notification Refer to Page 4 for an explanation of the No Read Notification parameter.
Page 19
CODE
SCANTEAM PDF417 Programming Menu
SELECTION III (STACKED)
USE THIS PAGE To select the pre-programmed asterisked (*) values by scanning DEFAULT symbol. To enable or disable listed code selections.
selections PDF417 ID = r (HEX 72)
scan
I parameters scan scan *Yes/No
Enable Macro PDF (2)
A
*Yes/No
Show Macro Control Block (3) (5)
B
Yes/No*
Show GLI Blocks (3) (5) One Pass Option (4)
C
Yes/No* Yes/No*
Notify When Certain (4) When To Decode Trigger Off Decoding (4) (6)
scan
D E
ENTER
Yes/No*
F
Automatic (6) Scan Diagnostics (7) G “No Read” Notification (8) G
0* 1* scan
Yes/No* Yes/No*
Notes: (1) * Denotes DEFAULT settings. (2) Macro PDF storage not available on SCANTEAM 2000 and SCANTEAM 3000 decoders. (3) Enabling either “Show” option causes backslash characters occurring normally in encoded data to be issued twice (i.e., as “\\”). (4) This feature is best used for the SCANTEAM 3700 machine mount scanner. (5) Features available for Macro PDF only. (6) The default for the When To Decode option is Trigger Off Decoding for the SCANTEAM 3700. The default for the When To Decode option is Automatic for the SCANTEAM 3000 and SCANTEAM 3400. (7) This parameter applies to scanners configured for RS-232 output. (8) This parameter applies to 3400 scanners configured for wand emulation output.
DEFAULT scan
ESCAPE scan
EXIT
17
Page 20
Notes: The space below may be used for notes.
18
✍