Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 3

SCANTEAM PDF417 Programming Menu, pages 1 to 10

Pages 1 to 10 of 30

The original document is the PDF (141 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the HHP ST3400

Page 1 read from a scan by OCR; it may hold reading errors

OLANTEAM

PDF417 Capable

CCD Reader a | ys Ny

PROGRAMMING MENU

WA

Welch Allyn

Page 2

NOTES

SCANTEAM PDF417 Programming Menu

The SCANTEAM PDF417 Programming Menu is used to program Decoded Output PDF417 Capable CCD Readers. The SAMPLE BAR CODES page (near the end of the programming menu) contains bar code symbols you may use to verify that you have programmed your SCANTEAM PDF417 scanner correctly.

Input Power Voltage Requirements Model 3000–X2 3000–X4 3400–X0X 3400–X2X 3400PDF/G–X2X 3700PDF/C–2331 3000–X1 3000–X3 3400–X1X 3400–X3X 3400PDF/G–X3X

Input Power Voltage 5 Volt ONLY

!

5 Volt Standard Cables or 12 Volt Special Cables

! Caution: DO NOT use SCANTEAM 3000 or 5500 12 Volt Interface Cables with the SCANTEAM 3400. DAMAGE TO YOUR 3400 WILL RESULT! Use the appropriate 3400 12 Volt Interface Cable. Disclaimer Welch Allyn reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Welch Allyn to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of Welch Allyn. Welch Allyn shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material.

This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Welch Allyn, Incorporated. E 1998 Welch Allyn, Inc. All rights reserved. Data Collection Web Addresss: http://dcd.welchallyn.com Windows is a trademark of Microsoft Corporation.

Page 3

SYSTEM

SCANTEAM PDF/PM Programming Menu

GUIDE

USE THIS PAGE As a general overview of the programming menu. The programming menu consists of two basic components as shown below. Programming Menu

CODE

Programming Menu

SELECTION II (RETAIL)

BAR CODE CHART II

USE THIS PAGE In combination with the adjoining menu pages to program the unit. The bar codes on this page correspond to symbols in shaded areas on adjoining menu pages. SCAN these bar codes in the sequence indicated on menu page to program desired selections and variables.

USE THIS PAGE

DIGITS

To select the pre–programmed asterisked (*) values by scanning DEFAULT symbol. To enable or disable listed code selections.

selections scan parameters scan scan

Version A Version D(2) Version E0 Version E1 Check Digit Xmit Number System Xmit Version E Expand 2–Digit Addenda 5–Digit Addenda

A B C D E F G H I

*Yes/No No* *Yes/No *Yes/No *Yes/No *Yes/No Yes/No* *Yes/No *Yes/No

II

EAN/JAN 13 EAN/JAN 8 Check Digit Xmit 2–Digit Addenda 5–Digit Addenda

A B C D E

*Yes/No *Yes/No *Yes/No *Yes/No *Yes/No

III

Enable

UPC ID = c (HEX 63)

I

EAN ID = d (HEX 64) UPC & EAN Addenda Req’d.

0 (YES)

5

1 (NO)

6

2

7

3

8

4

9 scan

ENTER scan

Yes/No*

DEFAULT Notes: (1) * Designates DEFAULT selections. (2) UPC Version D is not supported at this time.

scan

ESCAPE scan

EXIT

OTHERS

EXIT

ESCAPE DEFAULT

SAMPLE MENU PAGE

BAR CODE CHART

MENU PAGE Each menu page represents one section of the programming menu. Use individual menu pages in combination with the bar code chart on the back page foldout to program the decoder. USE THIS PAGE – A summary of the programming options (parameters) of each menu page. ENTER – Each menu page has its own unique ENTER bar code; scan this bar code to activate desired menu page. DEFAULT – The DEFAULT bar code allows the user to independently default menu pages to asterisked (*) values without affecting, in any way, the rest of the programming menu. Default values can be easily selected from the desired menu pages by scanning the bar code sequence ENTER, DEFAULT, EXIT. Individual defaults for a specific selection can be made by scanning ENTER, ROMAN NUMERAL, DEFAULT, EXIT. ESCAPE – Use this bar code to cancel current programming sequence. All parameters remain as they were. Scan ESCAPE to abort changes and exit from programming mode. EXIT – Scanning this bar code ends programming selection. Go from one menu page to another by scanning a new ENTER code (no need to scan EXIT between pages). Scan EXIT to save changes and end programming sequence. SELECTIONS/PARAMETERS – Lists all of the options available on each menu page. Following each option are symbols in shaded areas. These symbols correspond to bar codes on the adjoining bar code chart. NOTES – are provided to call out any unusual situations and/or refer you to necessary information or examples elsewhere in the menu or manual. Programming Note: Programming changes are in effect as soon as you make them! For example: changes to the beeper volume can be heard instantly. Likewise, changes to the baud rate parameters occur as soon as the “ENTER RS-232,” Roman Numeral “I,” and number (“0-6”) sequence has been scanned. EXIT will save the changes; ESCAPE will restore the original settings. Take care that programming parameters match your terminal settings.

MENU PAGE FACING (Not Shown) The page facing the menu is often used to supplement or clarify the material presented on the front of each menu page. The information and examples found here are specific to the individual menu page and contain, in some cases, charts and diagrams that must be used in order to determine the correct programming sequence.

BAR CODE DATA CHART The bar codes on this chart are assigned to a ROMAN NUMERAL, LETTER, DIGIT, OR YES/NO symbol. These bar codes correspond to the symbols in shaded areas on the menu pages and are scanned in various combinations to enter programming sequences to the decoder. Bar codes on this page are meaningless unless an ENTER bar code from one of the menu pages is first scanned. When an ENTER bar code is scanned, the bar code chart becomes specific to that menu page and remains so until the EXIT bar code is scanned or another menu page is selected.

1

Page 4

SCANTEAM PDF417 Information/Examples

BEEPER Volume

This programming selection provides control of the reader’s beeper volume. The beeper volume may be set from low to high in four increments. Default = “2,” medium–high.

Beep on Power Up When enabled, the reader will double beep each time the system is reset. When disabled, the beeper will not sound whenever the system is reset. Default = enabled (“Yes”).

Beep on Good Read When enabled, the reader will beep once following a successful decode. When disabled, the beeper will not sound following the decode. Default = enabled (“Yes”).

PDF417: Ticking Indicates Scanning Progress When enabled, the reader will emit a ticking sound as it scans a PDF417 symbol. The rate of ticking is proportional to the rate of data collection. When disabled, you will not hear a ticking sound while scanning a PDF417 symbol. Default = enabled (“Yes”).

PDF417: Humming Indicates Decoder Is Busy When enabled, the reader will emit a humming sound while it is decoding a PDF417 symbol. When disabled, you will not hear a humming sound while decoding a PDF417 symbol. Default = enabled (“Yes”).

What the Beeper is Telling you: As audible feedback, the PDF Capable reader provides five different beeps: single beep, double beep, triple beep, tick, and hum. One beep signals a successful barcode read. Single Beep Two beeps in succession indicate either: Double Beep • •

Triple Beep

Tick a hardware reset (as when the unit is first powered on) ENTER/EXIT/ESCAPE programming mode (when using the programming menu pages). Three quick beeps in succession indicate an error condition, as when an illegal menu code is scanned, or when the serial input buffer overflows. Every character sent to the PDF Capable reader is stored in a buffer. If the characters arrive faster than the reader can process them, it is possible (though rare) that the input buffer will completely fill up, and an overflow occurs. The “Tick” has the shortest duration, and no perceivable pitch. It is used to indicate scanning progress while reading PDF417. A tick is initiated for every 32 PDF417 codewords read. A high rate of ticking corresponds to a high rate of data collection, thus good printing and good scanning technique are indicated by a high ticking rate. Refer to the PDF Technical manual for printing/scanning suggestions. In general, keep the scan line of the reader aligned with the rows of the symbol. Printing smaller X-dimension and larger Y-dimension (row height) aids scanning ability.

Hum

2

The “Hum” is a steady tone with a lower pitch and volume than the beep, and a variable duration. The PDF417 reader cannot scan while decoding PDF417. When a great deal of error correction is required, the reader may appear to be “locked up.” Humming indicates that the reader is busy decoding. Use the ticking option for PDF417 to learn how to scan for optimum performance. Careful scanning greatly decreases PDF417 decoding time.

Page 5

BEEPER

SCANTEAM PDF417 Programming Menu

USE THIS PAGE To default this page to asterisked (*) values. To set beeper volume. To program beep on power up and / or beep on good read. To program ticking or humming to indicate scanning / decoding progress for PDF417.

selections VOLUME scan

I parameters Low scan scan

0

Medium–Low

1

Medium–High

2*

High

3 *Yes / No

BEEP ON POWER UP

II

Enable

BEEP ON GOOD READ

III

Enable

*Yes / No

TICKING INDICATES SCANNING PROGRESS

IV

Enable

*Yes / No

V

Enable

*Yes / No

ENTER

(PDF417 only)

HUMMING INDICATES DECODER IS BUSY scan

(PDF417 only) Notes: (1) * Denotes DEFAULT settings.

DEFAULT scan

ESCAPE scan

EXIT

3

Page 6

RS-232

SCANTEAM PDF417 Information/Examples

Baud Rate This programming selection sets the baud rate from 600 bits per second to 38,400 bits per second. Programming baud rate causes the data to be sent at the specified rate. Default = 9600 bits per second.

Character Format This programming selection allows you to set the character format for number of data and parity bits. PDF capable products support seven or eight bits of data and zero or one parity bit per character. The number of start and stop bits is fixed at one each. If an application requires only ASCII characters 0 through 127 decimal (text, digits, and punctuation), select 7 data bits. For applications requiring use of the full ASCII set, select 8 data bits per character. Default = eight data bits, no parity, and one stop bit. Note: PDF417 data is checked for accuracy before it is transmitted. This does not guarantee that errors will not be introduced during data communication. A parity bit may be added to each transmitted character as a means of character validation. A checksum character may also be added to the message as a suffix, for even stronger security (see Prefix/Suffix menu page). The receiving device must be set up for precisely the same character format as the reader, to ensure reliable communication.

Data Flow Control Flow control may be necessary to handle the larger PDF417 messages. The PDF417 reader will normally transmit a message immediately following a successful decode. With flow control selected, the receiver can enable/disable the reader’s transmitter. Default = “None,” no data flow control option selected. For example: suppose the receiver stores transmitted characters in a 512-byte buffer, yet the PDF417 reader has a 1400-byte message to transmit. The receiver might take 510 characters into its buffer, then tell the reader to STOP transmitting. As the receiver processes the message, space becomes available in the 512-byte buffer and the receiver can tell the reader to START transmitting again. Two methods of flow control have been implemented in the PDF capable products: RTS/CTS hardware handshaking, and an XON/XOFF protocol. RTS/CTS Handshaking This option uses two signals in addition to the transmit and receive signals. The reader will have control of the RTS signal, the receiver controls the CTS signal. Whenever the reader has a message to send, it will raise the Request To Send (RTS) line. If the reader has no messages to send, the line will be held low. When the receiver wants to suspend transmission, the Clear to Send (CTS) line will be held low. The reader looks at the state of CTS prior to sending each character. When the receiver is willing to accept a message from the reader, it should raise the Clear To Send (CTS) line. The reader will resume sending messages, continuing where it left off when the CTS line was lowered. XON/XOFF Protocol This option uses only the transmit/receive lines between the reader and the receiver. When the receiver wants to suspend transmission, it will send the XOFF character (ASCII 19 decimal) to the reader. When the receiver wants to resume transmission, it will send the XON character (ASCII 17 decimal) to the reader. The reader will resume sending messages, continuing where it left off when the XOFF character was sent. No Read Notification If Manual Trigger is enabled and you activate and deactivate the trigger without successfully reading a bar code, you will receive the output sequence {Prefix} “NR” {Suffix}. This occurs when the trigger switch is pressed or when the scanner is triggered serially.

4

Page 7

RS-232

SCANTEAM PDF417 Programming Menu

USE THIS PAGE To default this page to asterisked (*) values. To set baud rate. To program character format. To program data flow control.

selections scan parameters scan

BAUD RATE

I

600 bits/second

0

1200 bps

1

2400 bps

2

CHARACTER FORMAT

DATA FLOW CONTROL

II

III

4800 bps

3

9600 bps

4*

19200 bps

5

38400 bps

6

7 Data, Space Parity, 1 Stop

0

7 Data, Mark Parity, 1 Stop

1

7 Data, Even Parity, 1 Stop

2

7 Data, Odd Parity, 1 Stop

3

8 Data, No Parity, 1 Stop

4*

8 Data, Mark Parity, 1 Stop

5

8 Data, Even Parity, 1 Stop

6

8 Data, Odd Parity, 1 Stop

7

None

0*

RTS/CTS Handshaking

1

XON/XOFF Flow Control

“NO READ” NOTIFICATION

IV

2 scan

ENTER scan

DEFAULT scan

Yes/No*

Notes: (1) * Denotes DEFAULT settings. (2) RS-232 parameter changes are affected immediately (i.e., before scanning the EXIT bar code.)

ESCAPE scan

EXIT

5

Page 8

WAND EMULATION

SCANTEAM PDF417 Information /Examples

Overview The basic operation of this interface is to transmit the decoded bar code data to a decoding device by emulating the digital output of a wand. The transmitted Digital Output Signal emulates Code 128 symbology. All of the wand scans, except the last, will contain the Code 128 Message Append character, FNC2. This character will alert the decoder to concatenate each of the wand scans and effectively reconstruct the entire large message. Large messages are broken down into data blocks that are transmitted as individual wand scans.

Characters per Data Block This programming selection allows you to set the size of the data block which will be transmitted as a wand scan.

Delay Between Data Blocks This sets the effective delay between sub-symbols.

Effective Output Scan Rate This sets the transmission rate of the Digital Output Signal. The available parameters assume a bar code density of .010 inches (10 mil).

Digital Output Signal Polarity This programming parameter allows you to set the output logic convention for the digital output. The choices are White High (Laser Output) and Black High. Default = Black High.

Overall Checksum When enabled, a computed check character will be added at the end of the entire message. The check character is the character which when Exclusive-ORed with every preceding character of the message yields a result of 0x00 (00H).

Note: PDF Wand Emulation Users Encrypted PDF symbols (Veritas or Hypercompression) are designed to be used with specific applications running on the host device or PC. If the host device or PC is not running the specific application, the control sequences contained in the encripted PDF symbol could affect the host device or PC. For example, when connected to a PC running Windows and not running the specified application, symptoms range from different application functions appearing on the screen to various Windows options opening over the application which is running. Concurrent with this, you may notice that the Caps Lock and/or Num Lock keys may be turned on or off on the PC keyboard. This same sequence of events also could occur when you use a wand to scan a linear bar code label containing control sequences. It is highly recommended that you only scan PDF bar code labels when the host device or PC is running the proper application. It is also recommended that if you are going to scan a label into the Windows environment via a keyboard wedge, you test the label for possible problems. The problems should be corrected before committing to that PDF label. If you are using a PDF encrypted or control code label, and you encounter the above problems in Windows, it is recommended that RS-232 be looked into as an option. Note: If you are using Wand Emulation interface and connected to a SCANTEAM 2000: If your application requires that the Caps Lock key on the PC be left on, you may notice that your PDF displays upper case characters as lower case and vice versa. To resolve this problem, program the SCANTEAM 2000 for a Caps Lock Keyboard style. Refer to the Output Parameters page in the SCANTEAM 2000 Programming Menu. The default keyboard style is set to Primary. In the PC environment, the Caps Lock Keyboard style is Secondary. (Enter, II, B, Exit).

6

Page 9

SCANTEAM PDF417 Programming Menu

WAND EMULATION

USE THIS PAGE To default this page to asterisked (*) values. To set data block size. To program delays between data blocks. To set transmission.

selections scan

CHARACTERS PER DATA BLOCK

I

DELAY BETWEEN DATA BLOCKS

EFFECTIVE OUTPUT SCAN RATE(1)

DIGITAL OUTPUT SIGNAL POLARITY OVERALL CHECKSUM

II

III

IV V parameters scan

20

0

40

1

60

2*

80

3

5 ms

0

50 ms

1*

150 ms

2

500 ms

3

15 inches per sec.

0

30 inches per sec.

1*

60 inches per sec.

2

120 inches per sec.

3

Black Hi

0*

White Hi

1

Disabled

0*

Enabled

1

Notes: (1) Assuming a bar code density of .010 inches (10 mil).

scan

ENTER scan

DEFAULT scan

ESCAPE scan

EXIT

7

Page 10

TRIGGER

SCANTEAM PDF417 Information/Examples

Generally, a TRIGGER ON causes the reader to begin decoding, and a TRIGGER OFF halts decoding. The meaning of TRIGGER ON and TRIGGER OFF depends on the trigger mode.

Autotrigger Enable In autotrigger mode, the reader scans continuously. It does not, however, output decoded messages continuously. Internal logic determines when to output a decoded message. This decision is based on several factors, including the state of TRIGGER ON/OFF. In the context of autotrigger mode, TRIGGER ON and TRIGGER OFF are defined as: TRIGGER ON – The scanner senses the presence of several black/white elements (does not yet know if pattern is decodable). TRIGGER OFF – The scanner senses the lack of black/white elements. The reader’s new autotrigger logic is aggressive, resulting in fast reads. It is not necessary to TRIGGER OFF to read a new code. However, to reread the same code twice, you need to TRIGGER OFF for about a quarter of a second or until the scanner senses the lack of black and white elements.

Manual Trigger Enable In manual trigger mode, a TRIGGER ON is required to activate scanning and decoding. In the context of manual trigger mode, TRIGGER ON/OFF are defined as: TRIGGER ON – (A) The trigger switch is pressed or (B) The serial TRIGGER ON command (ASCII 18 decimal) is sent to the reader. TRIGGER OFF – (A) The trigger switch is released or (B) The serial TRIGGER OFF command (ASCII 20 decimal) is sent to the reader. In manual trigger mode it is necessary to TRIGGER OFF following a successful decode before another code can be read. The scanning stops immediately following a successful decode, but the reader is not TRIGGERED OFF until one of the conditions above has been satisfied. Note: If the scanner is triggered serially, it is not necessary to send the TRIGGER OFF command following a successful decode.

8