The text of a manual · part 3 of 3
SCANTEAM PDF417 Programming Menu, pages 21 to 30
Pages 21 to 30 of 30
The original document is the PDF (141 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the HHP ST3400
Page 21
SCANTEAM PDF417 Programming Menu
DISABLE ALL SYMBOLOGIES
USE THIS PAGE To disable all symbologies.
selections scan
DISABLE ALL CODES (1, 2)
X scan
ENTER
Scan the Roman numeral X to disable ALL symbologies. CAUTION: You will not be prompted to verify this option. scan
Notes: (1) All retail, industrial, and stacked symbologies will be disabled. (2) For optimum scanning performance, disable all codes and only use those symbologies relevant to your application requirements.
X scan
EXIT
19
Page 22
SERIAL MENU SCANTEAM PDF417 Programming Menu
Using the Serial Menu The serial menu may be used any time in place of the bar code menuing. The serial menu is particularly useful for programming PDF capable machine mount readers that do not have a hardware trigger. Every programming menu code can be replaced by a two character serial command. A serial device programs the reader by sending the proper sequence of serial commands. Use the menu pages to select the programming variables your application requires. For every menu code, the equivalent two character serial command (and its corresponding ASCII decimal value) are given in the SERIAL MENU CHARTS on the following pages. Example 1 If you want PDF417 enabled and all other bar code symbologies disabled, use the following sequence of serial commands: E <Ctrl–X> T <Ctrl–Y> <SPC> <Ctrl–Y> F<Ctrl–X> K <Ctrl–Y> 0 <Ctrl–Y> <SPC > <Ctrl–Y> The above serial commands correspond to the selections and variables on the programming menu page: • ENTER code for Disable All Symbologies Menu Page • Confirm Selection • “Exit” code for that menu page • “Enter” code for stacked codes • PDF417 selection (Roman Numeral I) • “Yes” (Digit 0) to enable PDF417 decoding • “EXIT” code for that menu page.
Example 2 If you wish to set the Beeper Volume to its highest setting, use the BEEPER menu page. The correct sequence of serial commands would be: A <Ctrl–X> K <Ctrl–Y> 3 <Ctrl–Y> <SPC> <Ctrl–Y> The above serial commands correspond to the selections and variables on the programming menu page: • ENTER code for that menu page • “VOLUME” selection (Roman Numeral I) • “HIGH” (Digit 3) to select the high option • “EXIT” code for that menu page.
Special Notes: Take care not to confuse the letter O and the number 0. Note also that the DEFAULT code is represented by a period (.) followed by <Ctrl–Y>. ASCII (decimal) values are included on the SERIAL MENU CHARTS (below the corresponding serial command). RS-232 parameter changes are immediately affected. The connected host serial device must also change to the programmed selections accordingly. After changing baud rate it may be necessary to wait a short amount of time for the serial port to stabilize. For this reason bar code menuing is suggested for changing RS-232 parameters.
In manual trigger mode, two serial commands may be used to turn the trigger on / off. The commands are: ASCII 18 (decimal) Ctrl–R Trigger ON ASCII 20 (decimal) Ctrl–T Trigger OFF For PDF417, the Notify When Certain character is: ASCII 23 (decimal) Ctrl–W Notify When Certain 20
Page 23
PDF417 Programming Menu
SERIAL MENU CHART I
USE THIS PAGE In combination with the adjoining menu pages to program the PDF417 by sending serial commands from the host. The serial command sequences on this page correspond to the bar code symbols on the BAR CODE CHARTS.
ROMAN NUMERALS K <Ctrl–Y> 75 25
<– Serial Command –> <– ASCII (decimal) –>
VI
I
L <Ctrl–Y> 76 25
<– Serial Command –> <– ASCII (decimal) –>
<– Serial Command –> <– ASCII (decimal) –>
<– Serial Command –> <– ASCII (decimal) –>
S <Ctrl–Y> 83 25 IX
IV
O <Ctrl–Y> 79 25
R <Ctrl–Y> 82 25 VIII
III
N <Ctrl–Y> 78 25
Q <Ctrl–Y> 81 25 VII
II
M <Ctrl–Y> 77 25
P <Ctrl–Y> 80 25
<– Serial Command –> <– ASCII (decimal) –>
T <Ctrl–Y> 84 25 X
V
ENTER CODES: MENU PAGES A <Ctrl–X> 65 24
<– Serial Command –> <– ASCII (decimal) –>
BEEPER
G <Ctrl–X> 71 24 TRIGGER
B <Ctrl–X> 66 24 RS-232
<– Serial Command –> <– ASCII (decimal) –>
C <Ctrl–X> 67 24 PREFIX / SUFFIX
21
Page 24
PDF417 Programming Menu
SERIAL MENU CHART II
USE THIS PAGE In combination with the adjoining menu pages to program the PDF417 by sending serial commands from the host. The serial command sequences on this page correspond to the bar code symbols on the BAR CODE CHARTS.
LETTERS A <Ctrl–Y> 65 25
<– Serial Command –> <– ASCII (decimal) –>
F <Ctrl–Y> 70 25
A
F
B <Ctrl–Y> 66 25
<– Serial Command –> <– ASCII (decimal) –>
G <Ctrl–Y> 71 25
B
G
C <Ctrl–Y> 67 25
<– Serial Command –> <– ASCII (decimal) –>
H <Ctrl–Y> 72 25
C
H
D <Ctrl–Y> 68 25
<– Serial Command –> <– ASCII (decimal) –>
I <Ctrl–Y> 73 25
D
I
E <Ctrl–Y> 69 25
<– Serial Command –> <– ASCII (decimal) –>
J <Ctrl–Y> 74 25
E
J
ENTER CODES: MENU PAGES D <Ctrl–X> 68 24
<– Serial Command –> <– ASCII (decimal) –>
INDUSTRIAL CODES
F <Ctrl–X> 70 24
22
STACKED CODES
E <Ctrl–X> 69 24 RETAIL CODES
<– Serial Command –> <– ASCII (decimal) –>
E <Ctrl–X> 69 24 DISABLE ALL CODES
Page 25
PDF417 Programming Menu
SERIAL MENU CHART III
USE THIS PAGE In combination with the adjoining menu pages to program the PDF417 by sending serial commands from the host. The serial command sequences on this page correspond to the bar code symbols on the BAR CODE CHARTS.
DIGITS 0 <Ctrl–Y> 48 25
<– Serial Command –> <– ASCII (decimal) –>
5 <Ctrl–Y> 53 25
0 (YES)
5
1 <Ctrl–Y> 49 25
<– Serial Command –> <– ASCII (decimal) –>
6 <Ctrl–Y> 54 25 6
1 (NO)
2 <Ctrl–Y> 50 25
<– Serial Command –> <– ASCII (decimal) –>
7 <Ctrl–Y> 55 25
2
7
3 <Ctrl–Y> 51 25
<– Serial Command –> <– ASCII (decimal) –>
8 <Ctrl–Y> 56 25
3
8
4 <Ctrl–Y> 52 25
<– Serial Command –> <– ASCII (decimal) –>
9 <Ctrl–Y> 57 25
4
9
OTHERS * <Ctrl–Y> 42 25
<– Serial Command –> <– ASCII (decimal) –>
<SPC> <Ctrl–Y> 32 25
ESCAPE
EXIT
. <Ctrl–Y> 46 25 DEFAULT
<– Serial Command <– ASCII (decimal)
23
Page 26
BAR CODE CHART I
PDF417 Programming Menu
USE THIS PAGE In combination with the adjoining menu pages to program your PDF417 scanner. The bar codes on this page correspond to symbols in shaded areas on adjoining menu pages. SCAN these bar codes in the sequence indicated on menu page to program desired selections and variables.
ROMAN NUMERALS
I
VI
II
VII
III
VIII
IV
IX
V
X
ENTER CODES: MENU PAGES
BEEPER
24
RS-232
TRIGGER
PREFIX/SUFFIX
Page 27
PDF417 Programming Menu
BAR CODE CHART II
USE THIS PAGE In combination with the adjoining menu pages to program your PDF417 scanner. The bar codes on this page correspond to symbols in shaded areas on adjoining menu pages. SCAN these bar codes in the sequence indicated on menu page to program desired selections and variables.
LETTERS
A
F
B
G
C
H
D
I
E
J
ENTER CODES: MENU PAGES
INDUSTRIAL CODES
RETAIL CODES
STACKED CODES
Page 28
PDF417 Programming Menu
BAR CODE CHART III
USE THIS PAGE In combination with the adjoining menu pages to program your PDF417 scanner. The bar codes on this page correspond to symbols in shaded areas on adjoining menu pages. SCAN these bar codes in the sequence indicated on menu page to program desired selections and variables.
DIGITS
0 (YES)
5
1 (NO)
6
2
7
3
8
4
9
OTHERS ESCAPE
EXIT
DEFAULT
Page 29
SAMPLE BAR CODES
SCANTEAM PDF417 Programming Menu
This page contains bar code symbols in some of the most commonly used symbologies. You may use these codes to test that your system is properly programmed for a particular symbology.
Code 39
TEST–SHEET Interleaved 2 of 5
1234567890 EAN–13
9780330290951 Codabar
0013557900
Code 128
CODE 128<BEL>
PDF417
WELCH ALLYN IS PDF CAPABLE!
UPC–A
5 add on
031323120786
56098
Page 30
PDF/PM
Rev D
Data Collection Division 4619 Jordan Road P.O. Box 187 Skaneateles Falls, New York 13153–0187