Page 31

Preamble characters may include Code ID and the ASCII characters (00–7F). These characters will be transmitted in the order in which the selections are programmed. Both preamble and postamble menuing must always start with a clean slate. Therefore, to clear all preambles, it is necessary only to complete the programming sequence SCAN ENTER, SCAN I, SCAN EXIT. If the Code ID is selected as a preamble, the wand will transmit a single lower case ASCII character to identify which symbology was decoded. For example, Code 3 of 9 is identified by a lower case “b,” while Code 128 is identified by a lower case “j.” The code identifier for each bar code symbology is listed below and appears immediately following the symbology name on the Symbology Selection Menu Page. SYMBOLOGY CODABAR Code 3 of 9 UPC EAN Interleaved 2 of 5 Code 2 of 5 MSI Code 11§ Code 93 Code 128

CODE ID a b c d e f g h i j

Postamble Postamble(s) are programmable data identifiers which follow the bar code messages. Up to five (5) postambles which include the ASCII characters (00–7F) can be programmed. Postamble characters will be transmitted in the order in which they are selected. Since postamble selections also begin with a clean slate, the programming sequence SCAN ENTER, SCAN II, SCAN EXIT will remove existing postambles from the decoder configuration. Programming the Scanner

4–7

Page 32

Function TX (Transmit) When this menu selection is enabled, and function codes are contained within the scanned data, the SCANTEAM 2380 transmits the key code to the terminal which corresponds to the decoded ASCII function code. ASCII function codes are represented by the HEX values (00–1F). When the Function Code Transmit selection is disabled, the scanner does not transmit the key codes which correspond to the HEX characters 01–1F unless they are in preambles or postambles. Instead, the characters 01–1F are stripped from the bar code data. Any keyboard function codes within data in the preamble and postamble will be sent to the terminal regardless of the parameter. Function codes in preambles and postambles are automatically translated to key codes. Note:

Care should be taken not to embed keyboard function codes that will cause an input inhibit condition within records, preambles, and postambles. Attempts to embed function codes may result in loss of data.

Example – Keyboard Function Codes (Commercial Application):

The SCANTEAM 2380 is connected to an IBM PC; Keyboard Function Codes within scanned data and the Preamble and Postamble on the COMM 1 section of the Programming Menu. The SCANTEAM 2380 is programmed as follows: Preamble: GS (1D)==>F10 key Postamble: CR (OD)==>ENTER key Full ASCII Code 3 of 9 Decoding: enabled Note:

When programming preambles and postambles you must scan a symbology before scanning in a scan code.

Consider the case of a Code 3 of 9 bar code symbol: 1 2 3 4 “HT” 5 6 7 8

The function emulated depends not only upon the Keyboard Function Code, but also upon the terminal being used with the SCANTEAM 2380. Appendix C lists, by terminal type, the key function emulated by each Keyboard Function Code. (The codes in the center column change.) 4–8

Programming the Scanner

Page 33

CASE 1 – Function Codes “Enabled”

With the Function Code Transmit selection enabled, the SCANTEAM 2380 outputs 1234HT5678 to the terminal as: F10

1 2 3 4 “TAB ”5 6 7 8 preamble

ENTER postamble

Notice that Keyboard Function Code, HT, has been translated and sent as the TAB key. CASE 2 – Function Codes “Disabled” (Commercial Application):

When the Function Code Transmit selection is disabled, the SCANTEAM 2380 outputs 1234HT5678 to the terminal as: F10

12345678

ENTER

Notice now that HT has been stripped from the data string. Note also, that Keyboard Function Codes contained within the Preamble and Postamble (F10 and ENTER) are not affected by the Function Code Transmit selection (XII) and so they are translated and sent. Keyboard Function Records

Keyboard Function Records are special incoming data records which originate from the Scanner. Keyboard Function Records are translated by the SCANTEAM 2380 and sent to the terminal as keyboard function keys. The function which is emulated depends upon both the Keyboard Function Record and the terminal selection. The key functions emulated by each Keyboard Function Record are listed according to terminal type in Appendix C. Keyboard Function Records differ from Keyboard Function Codes in the following ways: (1) Keyboard Function Records cannot be disabled by menu programming. (2) Keyboard Function Records cannot be embedded within other Scanner data; they are stand alone records, and if embedded, will be treated as normal data. Programming the Scanner

4–9

Page 34

(3) When Keyboard Function Records are entered, any Preambles/Postambles which may have been programmed will not be added to the output transmission. Example: Keyboard Function Records (Commercial Application)

The following examples illustrate the effect of Keyboard Function Records on data transmission. Scanner Data

In this example the SCANTEAM 2380 is connected to an IBM PC, and the function key F10 is to be emulated using a Keyboard Function Record entered through the Scanner. The symbology Full ASCII Code 3 of 9 has been enabled. When configured in this way, scanning a Code 3 of 9 label containing the following characters: /C31 will produce a decoded output of (#31). Keyboard Type This menu selection permits you to program the 2380 to output data using the following keyboard operating modes: NORMAL, CAPS LOCK, CRTL + AND SHIFT LOCK. NORMAL

This is the Primary Type keyboard selection. When NORMAL is enabled, the 2380 will output scanned data to the terminal in conventional bar code format. CAPS LOCK

When you are operating in CAPS LOCK mode, the 2380 should also be programmed for CAPS LOCK mode (i.e., CAPS LOCK enabled). CTRL + When the 2380 is programmed to operate in CTRL + mode, ASCII function codes 00 to 1F are sent to the terminal through a CTRL + sequence (i.e., “CR” = CTRL + M).

4–10

Programming the Scanner

Page 35

SHIFT LOCK

When you are operating in SHIFT LOCK mode, the 2380 should also be programmed for SHIFT LOCK mode (i.e., SHIFT LOCK enabled). Intercharacter Delay Intercharacter Delay is the time delay between data characters output by the 2380. The delay is in (X5) milliseconds and can be set to any value between 00 and 99 (X5ms). Interfunction Delay Interfunction delay is the time delay between “function key” characters output by the 2380. The delay is in (X5) milliseconds, and any value between 00 and 99 (X5ms) may be selected. Intermessage Delay Intermessage delay is the time delay between messages output by the 2380. The delay is in (X5) milliseconds and can be set to any value between 00 and 99 (X5ms). Beeper This programming selection permits control of the beeper located in the scanner as a means of indicating scanning activity to the operator. The BEEPER option described below is listed on the Programming Menu. Beep (On Reset) When “Beep” (On Reset) is enabled (YES), the beeper in the scanner will “beep once” to indicate that the wand is operational. This single “beep” can be interpreted as a SCANNER READY message from the wand. Beep (On Good Read)§ When “Beep” (On Good Read) is enabled (YES), the beeper in the scanner will “beep once” following a scan only if the bar code data has been accepted by the host. If the beeper does not sound, the scan should be repeated.

Programming the Scanner

4–11

Page 36

Append Buffer This scanner selection controls the status of the Append Buffer. When enabled, the Append Buffer stores messages (for example from a “barboard”), until a) it overflows, or b) a symbol without Append or in a new symbology is scanned. When either of these events occur, the contents of the buffer are transmitted, followed by the most recent scan. Note:

The Append Buffer must be enabled (YES), whenever the decoder is configured to read Code 93, Code 128 or Code 3 of 9 symbology with Append Option.

4.6 COMM 1 Menu Page§ The COMM 1 page of the Programming Menu is used to select a international keyboard and to reconfigure the 2380 for Intermec compatibility. An explanation of programmable selections follows. International Keyboards§ The SCANTEAM 2380 re–maps the keyboard layout appropriately for the selected international keyboard. International Keyboards are listed in the table below and appear on the COMM 1 page of the Programming Menu. International Keyboard

Code

France Germany Spain Switzerland Italy United States (USA)

A B C D E F (Default setting)

As a general rule, the following characters are not supported by the 2380 for international keyboards other than the United States: @ | $ # ^ ‘{ } [ ] = / Note:

4–12

PC users may need to program an Intercharacter Delay of at least 1 X 5ms when a keyboard other than the United States is selected.

Programming the Scanner

Page 37

Intermec Capability§ Scanning the “Yes” bar code allows the 2380 to be compatible with the Intermec keyboard function codes. Scanning the “No” bar code symbol causes the 2380 default keyboard codes in the preamble and postamble to remain active at all times. The default selection is “No.”

4.7 SCANCODE SELECTION Menu Page This menu page is used to select K2 scancode capability, new keyboard scancode table, beep PC, numeric keypad and RX interrupt. An explanation of programmable selections follows. K2 Scancode Compatibility This selection only applies to customers using AT, XT, or PS/2’s. If this selection is enabled (YES), the 2380 will use the same scancodes as the Welch Allyn SCANTEAM 2300 (K2). If this selection is disabled, the 2380 will use the scancodes found in Appendix C. All other terminals use K2 scancode tables which also appear in Appendix C. New Keyboard Scancode Table If the SCANTEAM 2380 has been downloaded to contain another scancode table, programming this selection to “Yes” will cause the new scancode table to be used, rather than the normal scancode table. This menu selection is applicable for use with terminals not equipped with standard manufacturer’s keyboards (that is, international keyboards). Beep PC§ When this menu selection is enabled (YES), the 2380 will beep the PC on a good read. This selection must be disabled (“No”) when “Beep on Reset” (OUTPUT PARAMETERS) is enabled. Note:

The master DEFAULT bar code on this menu page does not return this parameter to its default setting.

Numeric Keypad§ When “main keyboard numbers ” is selected, numbers will be sent to the host terminal as if keyed in from the main keyboard. If “numeric keypad” is enabled, numbers will be sent as if keyed in from the numeric keypad. Note:

The master DEFAULT bar code on this menu page does not return this parameter to its default setting. Programming the Scanner

4–13

Page 38

RX Interrupt§ Occasionally, keyboard activity will cause the wand to beep intermittently or turn off. This menu selection will prevent this from happening.

4.8 SYMBOLOGY SELECTION (CODES) Menu Page This Menu Page is used to program decoding selections. The 2380 can be configured to recognize and decode up to nine (9) popular bar code symbologies by scanning the proper code enabling (Selection) symbols on this Programming Menu page. After a particular code has been enabled, scanning the associated (Variable) code(s) will further program that symbology’s decoding parameters. Keep in mind that at power–up (or upon reset), the wand will automatically configure operating parameters to the last programmed values. Code options which are enabled (YES) will become the active operating parameters unless they are changed by the proper configuration command. Code options with an asterisk (*) next to the (NO) will automatically be disabled unless they are changed by the proper configuration command. Note:

To obtain maximum security when scanning bar codes, it is recommended that only those symbologies actually being used be enabled. Symbologies not being used should be disabled. Additional data security can be achieved by programming the maximum and minimum character counts when they are known.

Minimum Length A two (2) number code which describes the minimum number of characters that will permitted in the bar code message. The code length must always be represented by two digits. For lengths less than 10 characters, a zero (0) should be used as a filler, for example, (05). Maximum Length A two (2) number code which describes the maximum number of characters that will be permitted in the bar code message.

4–14

Programming the Scanner

Page 39

4.9 Message Format The wand will transmit data automatically to the host as soon as a bar code symbol is scanned. Each data transmission consists of three main elements, 1) a PREAMBLE, 2) the MESSAGE consisting of the bar code data, and 3) a POSTAMBLE. The actual content of the data transmission will depend upon the Preamble and Postamble characters and the decoded bar code information. The transmission format is shown below. PREAMBLE where:

MESSAGE

POSTAMBLE

PREAMBLE = Assigned Preamble Character(s) MESSAGE = Bar Code Data POSTAMBLE = Assigned Postamble Character(s).

Programming the Scanner

4–15

Page 40

4.10

Configuration Example

The following example illustrates the proper programming sequence to configure wand parameters to specific operating values. Example: Configure the SCANTEAM 2380 to decode the following symbologies:

Symbology: Maximum Length: Minimum Length: Start/Stop Character: Check Character: Check Character: Full ASCII Symbology: Maximum Length: Minimum Length:

Code 3 of 9 (Code 39) 14 8 Transmit Required Transmit Yes Code 128 12 6

Refer to the Selections/Variables table on the SYMBOLOGY SELECTION page of the Programming Menu. Program these operating parameters following the scanning sequence below. FUNCTION

SELECTION

Enter SYMBOLOGY SELECTION Menu Page Set DEFAULT Values Set Code 3 of 9 Set Minimum Length To 8

ENTER DEFAULT II

Set Maximum Length To 14 Set Start/Stop Characters To Transmit Scanning sequence continued on next page. 4–16

Programming the Scanner

VARIABLE

A 0 8 B 1 4 C Yes