Page 21

SET–UP AND INSTALLATION

3

3.1 Chapter Description This chapter describes: • Unpacking the SCANTEAM 2380 • Connecting the SCANTEAM 2380 • Confirming scanner operation • Checking bar code labels

3.2 Preparation The SCANTEAM 2380 is shipped ready for use. Upon receipt, open the carton(s) and check the contents. Check the part numbers and confirm that each item on the packing list has been supplied. Thoroughly inspect each component for possible shipping damage. Any damage should be reported immediately to the carrier who delivered the shipment. Damage claims due to handling during shipment should be placed directly with the carrier. When all components have been identified and checked, prepare the wand for service using the following procedure.

3.3 Set–up And Installation Installation steps should be performed in the sequence that follows to insure proper set–up and operation of the 2380. 1) Position the host unit power switch to the “OFF” position.

Set–Up and Installation

3–1

Page 22

The proper “Y” Interface Cable connections are illustrated in Figure 3.1.

Mini–DIN

DIN

Mini–DIN

Configuration 1

DIN

OR

Configuration 2

Converter Cable configurations Figure 3.1 “Y” Interface Cable Connections a) If you are connecting to an AT/XT terminal, plug the mini–DIN end of the converter cable into the mini–DIN end of the “Y” interface cable (configuration 1). If you are connecting to a PS/2 terminal, plug the DIN end of the converter cable into the DIN end of the “Y” interface cable (configuration 2). b) Disconnect the keyboard plug from the host device and insert it into the mating connector on the short leg of the “Y” interface cable. c) Complete the cable installation by inserting the converter cable into the keyboard connector port on the host device. 2)

3–2

When the SCANTEAM 2380 is fully connected, restore power to the host unit by turning the power switch ON. Set–Up and Installation

Page 23

3.4 Scanner Checks 1) Confirm Scanner Operation If you are using a wand which has visible red illumination, the tip of the scanner should glow red indicating that the wand is operational. In addition, at power–up, the beeper in the scanner should issue one (1) “beep” (if the 2380 has been programmed to “beep” on reset). 2) Check Bar Code Labels Before using any bar code scanner, make sure the label is of good quality and that the window area of your scanner is clean. This is very important because any dirt or specks in the bar code symbol or on the scanner optics may prevent it from reading accurately. Even a label that is smudged during printing or gets wrinkled when it is applied to an item can cause a reading problem. This completes installation of the wand to the host system. The wand decoder must now be configured to the particular decoding application. Instructions for programming the SCANTEAM 2380 decoded output scanner keyboard wedge using the bar code menu are contained in Chapter 4.

Set–Up and Installation

3–3

Page 24 read from a scan by OCR; it may hold reading errors

34

Set-Up and Installation

Page 25

PROGRAMMING THE SCANNER

4

4.1 Introduction Before the SCANTEAM 2380 can be placed in operation, it must be configured to the particular application by scanning bar code symbols from the Programming Menu. As program sequences are decoded by the 2380, both the desired operating parameters and data format instructions are stored in nonvolatile memory on the decoder pc board. A beeper is used to indicate scanning activity. The following relationships apply: 1)

The internal beeper will emit two (2) beeps when entering or exiting the programming mode (i.e., immediately following a scan of the ENTER and EXIT labels, respectively).

2)

When operating in the programming mode, each successful programming entry (decoder selection) will be acknowledged by a single “good read” beep.

4.2 The Programming Menu The complete SCANTEAM 2380 Programming Menu consists of six (6) pages: five Menu Pages and the Bar Code Chart. The five menu pages are labeled: TERMINAL SELECTION, OUTPUT PARAMETERS AND FORMAT SELECTION, COMM 1, SCANCODE SELECTION and SYMBOLOGY SELECTION. These pages list the decoder parameters controlled from that menu page and indicate the scanning sequence required to make specific configuration selections. The symbols used to control the configuration process are printed on the Bar Code Chart. 4.2.1 Programming Menu Pages All SCANTEAM 2380 programming menus follow a similar layout and contain the same programming elements. A typical programming menu page is shown in Figure 4.1. Programming the Scanner

4–1

Page 26

Each page contains a listing of decoder parameters which can be controlled from that menu and the scanning sequence required to make specific configuration selections. The symbols used to program the scanner are printed on the Bar Code Chart.

OUTPUT PARAMETERS

& FORMAT SELECTION

SCANTEAM 2380 Programming Menu

1 scan

USE THIS PAGE To select the pre–programmed asterisked (*) values by scanning DEFAULT symbol. To add preambles and/or postambles to the bar code. To select function transmit enable. To select keyboard type. To set intercharacter, interfunction, and intermessage delays to specific values. To control scanning indicators. To enable the Append Buffer when Code 3 of 9 with append option is enabled.

selections ENTER

3 scan

DEFAULT scan variables scan

PREAMBLE (up to 5 chars max)

Code ID Other ASCII

A B

POSTAMBLE (up to 5 chars max)

ASCII values

A

FUNCTION XMIT

Enable

*Yes/No

KEYBOARD TYPE

Primary

01*

Secondary

02

Tertiary

03

2

4 INTERCHARACTER DELAY INTERFUNCTION DELAY INTERMESSAGE DELAY BEEPER

APPEND BUFFER scan

00–7F None* 00–7F None*

Quaternary

04 x5msecs

*00–99 x5msecs

*00–99 x5msecs

*00–99

Beep (on Reset)

A

*Yes/No

Beep (on Good Read)

B

*Yes/No

*Yes/No scan

6

NOTES: (1) * Designates DEFAULT selections. (2) To delete preambles Scan I then either another selection (roman numeral) or Exit. (3) To delete postambles Scan II then either another selection (roman numeral) or Exit. (4) See facing page for more information and examples.

EXIT

5 Figure 4.1 Example of Programming Menu Page

4–2

Programming the Scanner

Page 27

The general elements found on each menu page include: (1) A “USE THIS PAGE” statement that indicates the programming options (capabilities) which appear on that menu page. (2) The SELECTIONS/VARIABLES table which lists primary programming selections, variables which can be used to modify the basic selection and the bar code scanning sequence that must be used to configure the scanner to these values. Three discrete bar code commands perform global menu selections and control movement between the different menu pages. These discrete commands include: (3) An ENTER command. Scanning this bar code symbol will activate that particular menu page. The ENTER code for each menu page is unique, and must be scanned before configuring commands from that page will be recognized by the scanner. (4) A generic DEFAULT command which, when scanned, causes all of the programming selections/variables which appear on that particular menu page to automatically default to the values marked by an asterisk(*). Entering a DEFAULT instruction before beginning to program brings all of the parameters on that page to a known value and thus helps to avoid programming confusion. (5) The EXIT command is used to conclude programming on the active menu page. The EXIT symbol must be scanned before moving to another page of the programming menu. Information regarding special bar code applications is often provided at the bottom of menu pages. These include: (6) The special NOTES used to explain unusual programming requirements and/or refer the user to necessary information or examples elsewhere in the menu or the 2380 manual. Programming the Scanner

4–3

Page 28

4.2.2 Facing Page The page facing the programming menu is frequently used to supplement or clarify material presented on the menu page and may contain programming examples. 4.2.3 The Bar Code Chart The SCANTEAM 2380 Bar Code Chart shown in Figure 4.2 is an integral part of the Programming Menu. It contains the printed bar code symbols which are scanned to program the desired selections.

BAR CODE CHART

SCANTEAM 2380 Programming Menu

USE THIS PAGE In combination with the adjoining menu pages to program the 2380. The bar codes on this page correspond to symbols in shaded areas on adjoining menu pages. SCAN these bar codes in the sequence indicated on menu page to program desired selections and variables.

ROMAN NUMERALS

I

LETTERS

A XI

ESCAPE

B XII

III

DEFAULT 1 (NO) EXIT

C XIII

IV

2 D

XIV V

3 E

XV

4 F

Figure 4.2 Bar Code Chart 4–4

OTHERS

0 (YES)

II

VI

DIGITS

Programming the Scanner

Page 29

Note that the chart contains symbol groupings that include ROMAN NUMERALS, LETTERS and NUMBERS. The sequence in which these symbols are scanned generates the programming instructions which enable or disable specific decoder functions. The right hand column of the Chart contains three (3) bar code symbols labeled DEFAULT, ESCAPE and EXIT. When these symbols are scanned specific instructions are instantaneously sent to the wand. The function of these commands is explained below. DEFAULT

Scanning this symbol installs default values (indicated by *’s) at the active programming level. For example, if the DEFAULT symbol is scanned immediately following Page ENTER, it defaults the entire menu page. If it is scanned following a major category selection like Codabar, it will default that whole category. If DEFAULT is scanned following a subcategory selection such as Code 128/Minimum Length, it will default just that subcategory. EXIT

Scanning the EXIT symbol produces a command which can be used to terminate programming on either menu page. The EXIT symbol must be scanned before moving to or attempting to program on a different menu page. When it is scanned, all configuration instructions for parameters appearing on that page will be stored in memory. ESCAPE

Scanning the ESCAPE symbol generates a command that will terminate a programming sequence before it is completed and without saving the configuration information. It can be used when a Selection and/or Variable has been scanned in error. The programming sequence must then be restarted.

Programming the Scanner

4–5

Page 30

Note:

The symbol “ § ” placed next to a programmable feature indicates that this feature is not supported in all wand models/software revisions.

4.3 DIRECT CONNECT TERMINAL SELECTION Menu Page This menu page is used to make a direct connect terminal selection An explanation of programmable selections follows. Direct Connect Terminal Selection The terminals that may be selected by scanning the appropriate direct connect bar code are IBM AT and compatibles, IBM XT and compatibles, and IBM PS/2 Model 30. The IBM AT, XT or PS/2 is configured by scanning the one bar code on this page, instead of scanning the ENTER code, the two digit terminal identifier code and the EXIT code on the TERMINAL SELECTION menu page.

4.4 TERMINAL SELECTION Menu Page This menu page lists the types of host devices which are supported by the 2380, and shows the scanning sequence that should be used to configure the scanner interface to be compatible with a particular host PC.

4.5 OUTPUT PARAMETERS & FORMAT SELECTION Menu Page This menu page contains parameter selections used to control the data message that will be sent from the scanner to the host. An explanation of programmable selections follows. Preamble Preambles are assigned using the programming menu. When the Preamble selection is enabled, any combination of up to five (5) identifiers are transmitted as a header immediately preceding scanned bar code data.

4–6

Programming the Scanner