Page 11

INTRODUCTION TO THE SCANTEAM 2380 SCANNER

1

1.1 Introduction The SCANTEAM 2380 Decoder Output Scanner Keyboard Wedge is a convenient and cost effective way of adding bar code data entry capability to the IBM (and IBM compatible) PC/XT/AT personal computers and IBM PS/2 Models 30, 50, 60 and 80. Additional interfaces are continually being developed; check with Welch Allyn or an authorized representative for availability. As described on page 1–4, the SCANTEAM 2380 is available in the following models: 2380/J and 2380/K with visible red illumination. All models of the 2380 are available with stainless steel scanner housings. The contents of this manual applies to these devices except where differentiated. The SCANTEAM 2380 is designed to read and decode any of nine (9) popular bar code symbologies and output the bar code data to the keyboard port in the same format the keyboard does.

1.2 Hardware Description The SCANTEAM 2380 system consists of the wand body and a 6’ (1.8m) coil (extended) interface cord. When connected as shown in Figure 1.1, the 2380 keyboard “wedge” device provides a transparent interface between the keyboard and the keyboard input port of the host device. Operation of the SCANTEAM 2380 with a particular computer is accomplished by installing the proper “Y” interface cable and programming the proper keyboard interface routine using the TERMINAL SELECTION sheet of the programming menu.

Introduction to the SCANTEAM 2380

1–1

Page 12

Once installed, the 2380 simply passes keyboard activity onto the host. Symbols decoded by the SCANTEAM 2380 are translated to corresponding keyboard keycodes and then sent to the keyboard input port of the terminal. Thus, the data appears as if it has been “keyed in” at the keyboard.

Figure 1.1 SCANTEAM 2380 Keyboard Wedge Connection Decoding capability is achieved through the use of an internal microprocessor. All SCANTEAM 2380 units are referred to as contact scanners since the tip of the wand must be in or near contact with the bar code label in order to read.

1–2

Introduction to the SCANTEAM 2380

Page 13

1.3 Software Description The standard SCANTEAM 2380 is configured for specific user applications by scanning bar code symbols from the printed programming menu which is supplied with the unit. System software will support the keyboard model normally supplied with the host device, and is capable of emulating keyboard “function keys.” The SCANTEAM 2380 may be programmed to autodiscriminate among the following bar code symbologies and their variations: CODABAR, Code 3 of 9, UPC, EAN/JAN, Code 2 of 5, Interleaved 2 of 5, Code 93, MSI, Code 128 and Code 11§. In addition to the bar code symbology selections, certain input/output parameters, message format and communications protocol are programmable using the wand with the programming menu. All programmable parameters are stored in non–volatile memory resident in the wand where they are permanently retained in the event of power interruption to the 2380 or the host device. §

This feature is not supported in all wand models/software revisions.

Introduction to the SCANTEAM 2380

1–3

Page 14

1.4 Wand Models The SCANTEAM 2380 decoded output scanner keyboard wedge is available in the following Welch Allyn industrial grade digital wand scanner models: SCANTEAM 2380/J and SCANTEAM 2380/K The 2380/J and 2380/K are “SRD” scanners, meaning they have a visible red LED illumination source. These units feature a durable body and a replaceable tip. The 2380 has a Welch Allyn logo on the scanner housing. Either of the models may be ordered with high, medium or low resolution scanning optics so as to meet special requirements imposed by the label substrate and printing method or environmental factors which affect bar code label quality. For additional assistance in selecting the SCANTEAM 2380 decoded output scanner keyboard wedge best suited to your bar code application, contact Welch Allyn or an authorized representative.

1–4

Introduction to the SCANTEAM 2380

Page 15

OPERATIONAL DESCRIPTION

2

2.1 Chapter Objectives This chapter describes: • Scanner identification key. • Overview of how the SCANTEAM 2380 works, including scanning aperture, depth of field and scanning velocity. • Reading and decoding a bar code symbol. Description of print contrast, high and low density bar code symbols. • Discussion of RS–232 interface and external power options.

2.2 Main Elements of the 2380 Bar Code System The major operational elements of the SCANTEAM 2380 decoded output scanner keyboard wedge include the scanner optics, the digitizing electronics and the decoding circuitry. The key components of the scanner optical system are the illumination source (LED) and the illumination sensor (photodiode). Both the LED and photodiode are positioned directly behind a specially designed lens in the scanner body. Cable connections are made directly to the board and exit the scanner body through a flexible strain relief at the end of the wand handle. The integral cable shield affords EMI and associated drain protection to output signals.

Operational Description

2–1

Page 16

2.3 Scanner Identification Label The scanner identification label is located on the scanner’s cable. The identification corresponds to the configuration work sheet description. (Welch Allyn p/n 16206714)

2.4 Operating Theory The reading ability of the wand scanner is based on the detection of reflected illumination from the bars and spaces which form a bar code symbol. During a typical scanning operation, the tip of the scanner is moved across the bar code symbol. Illumination from the LED is focused on the bar code symbol. This is absorbed by the dark colored bars and reflected by the lighter background. The reflected portion re–enters the scanner through the lens where it is detected by the read sensor photodiode. The photodiode converts this into a series of analog pulses which are proportional in width to the bars and spaces in the symbol. These pulses are then digitized and sent to the microprocessor where they are decoded into the characters represented by the bar code symbol.

2.5 Factors Affecting Scanning Performance The following factors influence reading performance and should be considered when selecting a contact scanner for a particular bar code application. 2.5.1

Scanner Illumination Source

Wand type scanners are equipped with a visible red (660nm) source.

2–2

Operational Description

Page 17

Red illumination is compatible with most printing inks including most thermal papers. Because it provides a visual indication to the operator that the scanner is functioning, red illumination is considered to be more user friendly. Visual feedback to the operator is an important consideration when making a scanner selection. 2.5.2 Scanning Aperture Scanning performance is affected by the size of the scanning aperture and it is a significant factor to be considered when selecting a scanner. The scanning aperture defines the effective size of the area of the bar code symbol viewed by the scanner optics. It affects the relative ability of the scanning device to “see” or resolve bars and ignore printing defects. Large aperture systems typically cannot resolve high density bar code or the small printing features (voids within bars or dark specs within the light areas) that small aperture systems would. Thus, they are more compatible with low density bar code and more tolerant of printing defects characteristic of poorly printed labels. Small aperture systems (high resolution) are better able to resolve which makes them compatible with high density good quality symbol reading requirements. The SCANTEAM 2380 is available with circular apertures ranging from 6 to 8 mil. Most scanning applications can be satisfied with a 6 mil (high resolution) or a 8 mil (low resolution) aperture. When selecting an aperture, it is recommended that the aperture dimension be no less than 0.7 times the “X” (width of the narrowest bar code coding element) dimension to be read. An aperture size that is slightly smaller than the narrowest bar code element, 0.9 times “X,” provides optimum resolution of the bars and results in the generation of a digital signal which accurately represents the bar code. An 8 mil (0.2mm) aperture is often a good compromise when labels produced by different printing and label generation methods must be read with one scanner. In no case should the viewing aperture exceed 1.2 the “X” dimension. Operational Description

2–3

Page 18

2.5.3 Depth of Field Depth of field is the maximum perpendicular distance from the scanner tip to the bar code symbol surface at which the scanner is capable of operating effectively. In general, most of the SCANTEAM 2380 scanners have a depth of field of 0.065 inches (1.65mm) with a symbol appropriate for the scanner. A chart showing the relationships between depth of field, scanning aperture and bar code density appears on page A–1. In normal use, the wand is seldom held perpendicular to the surface of the bar code symbol. Rather, an operator tends to tilt the scanner. Useable scan angle is a function of tip geometry and depth of field. If the depth of field is too small, the scanner may fail to operate at extreme tilt angles (>35°). 2.5.4 Scanning Velocity The wand will operate at scan velocities from 2 to 50 inches/second (5 to 127cm per second) when the minimum bar/space size exceeds 7 mils (0.18mm). 2.5.5 High Density vs Low Density Bar Code Symbols Bar code density is a measure of the number of characters in a linear measure of bar code. The standard of measure is normally given in terms of the “X” dimension, the width of the narrowest bar code element. As bar code density increases, the width of the narrowest bar code element decreases. The scanning aperture should always be smaller than the narrowest element to assure optimum resolution and the generation of a digital signal which accurately represents the bar code.

2–4

Operational Description

Page 19

2.5.6 Print Contrast Print contrast is a measure of the relative difference in brightness between the bars and spaces of a symbol and is specified as the Minimum Reflectivity Difference (MRD). The MRD is the difference between the lowest minimum space reflectance value and the highest maximum bar reflectance value as measured across the entire symbol. MRD = Max (Rb max) – Min (Rs min) where:

Rs min = Minimum Space Reflectance Rb max = Maximum Bar Reflectance

The scanner will operate with a MRD as low as 37.5% with the proper aperture and appropriate symbol. A complete description of bar code specifications for factors which affect overall bar code quality are provided on page A–5.

Operational Description

2–5

Page 20

2–6

Operational Description