The text of a manual · part 5 of 7
SCANTEAM 2380 Wand Keyboard Wedge/Decoded Out Wand Technical Manual, pages 41 to 50
Pages 41 to 50 of 68
The original document is the PDF (254 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST2380
Page 41
FUNCTION
SELECTION
Set Check Digit To Required Set Check Digit To Transmit Set Full ASCII To Enabled Set Code 128 To Enabled Set Minimum Length To 6
D Yes E Yes F Yes VIII
Set Maximum Length To 12 Disable CODABAR(1) Disable I 2 of 5(1) Disable Code 11(1) Disable Code 93(1) Disable MSI (Plessey)(1) Leave Menu Page
VARIABLE
I III V VI VIII EXIT
Yes A 0 6 B 1 2 No No No No No
(1) – To maximize reading efficiency and security, all unused codes should be disabled. Because all industrial codes default to an enabled (YES) state, it is necessary to disable all codes except Code 39 and Code 128.
Programming the Scanner
4–17
Page 42
4.11
Keyboard Layouts and Delimiters
A delimiter is the unique keycode generated by a particular terminal key whenever it is depressed. Every key on the keyboard is assigned its own code. The terminal uses these codes to identify the key that was depressed, and the function that key represents. The SCANTEAM 2380 can be programmed to recognize these function keycodes as field delimiters. When field delimiters are used to separate bar code data, the terminal interprets the data codes produced by scanning a bar code symbol(s) as originating from the keyboard without the function key being depressed. Delimiters for a particular terminal can be determined by referring to the keyboard layouts provided on the Keyboard Layouts page of the programming menu. Refer to Figure 4.3 for an example of the keyboard layout for an NCR 7052/32 and 56 key terminal. C2
C5
C8
D1
D4
D7
E0
C3
C6
C9
D2
D5
C8
E1
C4
C7
D0
D3
D6
D9
E2
A0
A5
B0
B1
B2
B7
E3
A1
A6
B3
B8
E4
A2
A7
B4
B9
E5
A3
A8
B5
C0
E6
A4
A9
B6
C1
E7
Figure 4.3 NCR 7052/32 & 56 Key Terminal Note that certain keys are marked with a number and letter. These designations (i.e., the A1, A5, C3 etc.) are the delimiters associated with that particular function key. Once the delimiters have been programmed, the SCANTEAM 2380 automatically generates the proper keycode and sends it to the terminal just as though the terminal function key had been depressed.
4–18
Programming the Scanner
Page 43
5
MAINTENANCE AND TROUBLESHOOTING
5.1 Scanner Maintenance And Service All Welch Allyn SCANTEAM 2380 units are designed to provide reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks will contribute significantly to dependable scanner operation.
5.2 Cleaning The sapphire tip is designed to be maintenance free, but may be cleaned when necessary. The tip of the scanner must be kept clean to assure high first pass reading performance. Since a dirty tip can impair scanning performance, the tip should be examined whenever scanning performance begins to degrade or if the tip has become visibly dirty. If the tip becomes dirty, it should be cleaned by wiping with a soft cloth or facial tissue that has been dampened with a mild detergent and water solution. The scanner enclosure can also be cleaned using the same procedure. Note:
DO NOT use abrasive tissues or wipers as these will scratch the tip. NEVER use solvents (ie. alcohol or acetone) on the tip or to clean molded handle scanners since these may damage the finish.
Maintenance and Troubleshooting
5–1
Page 44
5.3 Inspection Cords And Connectors The scanner cord and the “Y” interface cable should be inspected periodically for wear and other signs of damage. A badly worn cord may interfere with the proper operation of the unit and may require replacement of the scanner. Damaged scanner cables and/or connector(s) can be repaired/replaced by Welch Allyn. Scanner Case The scanner enclosure should also be routinely examined for signs of damage. A badly dented enclosure may contact internal components and result in damage to or malfunction of the unit.
5.4 Troubleshooting If the scanner fails to operate properly, perform the following checks:
5–2
1)
Check the “Y” interface cable connection(s) to make sure the scanner is properly attached to the host P.C.
2)
If the unit has been programmed to “beep” on Reset, did it “beep”? Failure to beep indicates a possible internal wand problem. Contact Welch Allyn for assistance (refer to page 5–4).
3)
Confirm that the scanner has been programmed for the correct terminal.
4)
Confirm that the scanner is properly configured for the bar code symbology(s).
5)
Inspect the quality of the bar code symbols that are being used. Symbols that are of a low contrast, scratched or otherwise defaced may cause scanning problems. To verify scanner operation, test the system with a high quality bar code symbol. As an additional check, verify the quality of bar code symbols with a bar code verifier such as the Quick Check, available from Welch Allyn. Maintenance and Troubleshooting
Page 45
6)
Check the condition of the scanner tip. If the tip is scratched, the scanner may not read properly. If the tip is broken or cracked, the optics may also become damaged by dust or other foreign matter. Should either of these conditions be present, replace the scanner tip. The tip can be removed by inserting a thin coin into the tip locking ring and prying it off the end of the scanner. Do not touch or make contact with the exposed lens surface as permanent damage to the scanner optics may result. Welch Allyn recommends keeping a supply of spare tips on hand. If replacing the tip does not correct the scanning problem, it may be necessary to replace the entire wand unit.
Note:
Other than the replaceable tip, the wand scanner contains no user serviceable parts and, therefore, the scanner case should not be opened. Opening the scanner voids the warranty.
If proper wand operation cannot be obtained after performing these checks, factory service may be required.
Maintenance and Troubleshooting
5–3
Page 46
5.5 Obtaining Factory Service in the United States Welch Allyn provides service for all its products through a service center located at its manufacturing facilities in Skaneateles, New York. To obtain warranty or non–warranty service, return the unit to Welch Allyn (postage paid) with a copy of the dated purchase record attached. Please contact the Welch Allyn Product Service Department at the address/telephone number listed below to obtain a Return Material Authorization number (RMA #). Welch Allyn, Inc. Data Collection Division Product Service Department 4619 Jordan Road P.O. Box 187 Skaneateles Falls, New York 13153–0187 Product Service Department Telephone: (315) 685–4278 or 685–4360 Fax: (315) 685–4156
Obtaining Factory Service in Europe For service in Europe, please contact your Welch Allyn representative (at appropriate address below) or your local distributor. Welch Allyn, Ltd. Block 1, Bracken Business Park Sandyford Co Dublin Ireland Telephone: Int+353–1295–0750 Fax: Int+353–1295–6353 U. K. Office Dallam Court Dallam Lane Warrington, Cheshire WA2 7LT England Telephone: Int+44 1925 240055 Fax: Int+44 1925 631280 5–4
Maintenance and Troubleshooting
Page 47
Obtaining Factory Service in Asia For service in Asia, please contact your Welch Allyn representative (at address below) or your local distributor.
Welch Allyn, Hong Kong Office 10/F Tung Sun Commercial Centre 194–200 Lockhart Road Wanchai, Hong Kong Telephone: Int+852–2511–3050 or 2511–3132 Fax: Int+852–2511–3557
Technical Support If you need assistance installing or troubleshooting your scanner, please call your Distributor or the nearest Welch Allyn technical support office. North America: Telephone: Fax: E–Mail:
(315) 685–2476 (8am to 6pm EST) (315) 685-4960 dcd_techsupt@mail.welchallyn.com
Europe: United Kingdom Telephone: Int+44 1925 240055 Ireland Telephone: Int+353–1216–0070 Asia: Telephone: Int+852–2511–3050 or 2511–3132
Maintenance and Troubleshooting
5–5
Page 48
5–6
Maintenance and Troubleshooting
Page 49
A
TECHNICAL SPECIFICATIONS
A.1 Scanner Performance Bar/Space Deviation: While scanning appropriate bar code symbols, the first bar elongation and inner bar/space errors over the depth of field are defined as follows. First Bar Elongation:
< +0.006 inch (0.15mm) –0.002 inch (0.05mm)
Inner Bar/Space Error:
< +0.002 inch (0.05mm)
A.2 Optical Specifications Effective Scanning Aperture:
6 – 10 mil
Light Source:
Red LED (Wavelength = 660 nm)
Depth of Field:
- - - - -
- -- - --
Tilt Angle:
- -
Technical Specifications
- -- - --
A–1
Page 50
A.3 Electrical Specifications The scanner will function but may not operate within the specified tolerances if the operating voltages indicated below are exceeded. Operating Voltage:
4.5 VDC – 5.5 VDC
Operating Current:
Maximum Typical
Power Supply Noise Rejection:
35 mA 20 mA
Withstands up to 100mV p–p noise and ripple
Scanner Connector Connector Size/Type: Two 6 pin Mini DIN, one male, one female 6 Pin Mini Din Female 2 1
3
6 Pin Mini Din Male
4
5
1
2
4
6
3
6
5
Connector Pin Assignments 6 Pin Mini DIN Female (connects to keyboard)
6 Pin Mini DIN Male (connects to terminal)
Pin
Color
Function
Pin
Color
Function
1 3 4 5 Metal Shield
Green White Red Yellow Cord Drain
Keyboard data Ground V+ Keyboard clock
1 3 4 5 Metal Shield
Blue White Red Black Cord Drain
Terminal data Ground V+ Terminal clock
Cable shield♦
Cable shield♦
♦ Shield Isolation: The resistance between the shield and the power supply common termination exceeds 1 meg ohm. The flashover voltage exceeds 40VDC. A 10KHz AC signal with an amplitude of 1.0 pp can be placed between the shield and the common termination with no operational affect.
A–2
Technical Specifications