For the HHP ST2070, HHP ST3870 and HHP ST5770

Page 63

3

Communications Menu

Introduction Use this section to program the communications parameters for the cordless system. This programming section contains the following menu selections: • Host Port Protocol/Communications (RS-232) • Auxiliary Port Protocol/Communications (RS-232)

3-1

Page 64

Host Port Protocol Default Host Port Protocol <Default All Host Port RS-232 Protocol>

Baud Rate Selection This selection sets the baud rate from 300 bits per second to 38,400 bits per second. Programming baud rate causes the data to be sent at the specified rate. The host terminal must be set up for the same baud rate as the cordless system to ensure reliable communication.

300

600

1200

2400

4800

9600

19200

*38400

3-2

Page 65

Host Port Protocol Parity Selection This selection provides a means of checking character bit patterns for validity. The cordless system can be configured to operate under Even, Odd, Mark,None, or Space parity options. The host terminal must be set up for the same parity as the cordless system to ensure reliable communication.

*None

Space

Mark

Even

Odd

Word Length Data Bits Selection This selection sets the Word Length at seven or eight bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications requiring use of the full ASCII set, select 8 data bits per character.

7 Data Bits

*8 Data Bits

3-3

Page 66

Host Port Protocol Word Length Stop Bits Selection This selection sets the Word length at one or two stop bits.

*1 Stop Bit

2 Stop Bits

3-4

Page 67

Host Port Communications Hardware Flow Control Selection This selection turns on hardware flow control that checks for a CTS signal before sending data. This option is useful when your application supports the CTS signal.

Note: This selection cannot be used with Serial Wedge Output Selection.

On

*Off

Serial Wedge Output Selection This selection selects the serial output direction required by your application. P1 and P2 are serial wedge designations printed on the serial wedge cable. Usually, one goes to the host and one goes to the terminal, depending on your specific application and the serial wedge cable.

To P1

To P1 and P2

To P2

*None (Host Port RS-232)

3-5

Page 68

Host Port Communications Host ACK Selection Some applications require that the host terminal (or server) approve or reject incoming bar code data and notify the operator of these actions. These applications require that the host maintain control over the response indicators emitted from the source scanner. Turning the Host ACK selection on, configures the cordless system scanners to respond to commands from the host system. The following criteria must be met for the Host ACK to work correctly: • The cordless system must be configured for “Host Port RS-232” (Terminal ID = 050) • Both the host terminal and the cordless system must have RTS/CTS handshaking ("Hardware Flow Control Selection" on page 3-5) enabled. • Host ACK must be enabled (page 3-7). • System performance degrades when using Host ACK at rates lower than 9600. • The host terminal software must be capable of interpreting the bar code data, make decisions based on the data content, and send out appropriate escape commands to the source scanner. Escape commands are addressed to the source scanner via “Application Work Groups.” Once a command is sent, all scanners in a group respond to that command. Because of this situation, it is recommended that each scanner is assigned to its own group. The commands to which the scanner responds are listed on page 3-8 and page 3-9. The <ESC> is a 1B hex. A typical command string is y <ESC> x, where “y” is the application work group number, “<ESC> x” is the escape command, and the comma is the terminator. Up to twenty commands may be strung together to create custom response sequences. An example of a command is listed below. 0<ESC>4<ESC>5<ESC>6, The above example will make a scanner in application work group zero beep low, medium, high. Once Host ACK is enabled, the system works as follows: • The scanner reads a code and sends data to the base/host system. No audible or visual indication is emitted, unless “Decode Beep” is enabled (page 3-10). The scanner read indicator goes out upon a successful read. • Scanner is suspended until 1) a valid escape string is received from the host system (via the base) or 2) the scanner “times out.” • Once condition 1 or 2 above has been met, the scanner is ready to scan again, and the process repeats. Time out is indicated by three rapid beeps at the same pitch. A time out occurs if the source scanner does not receive a valid escape command in 10 seconds. If a time out occurs, the operator should check the host system to understand why a response to the scanner was not received.

3-6

Page 69

Host Port Communications Host ACK Enable

On

*Off

3-7

Page 70

Host Port Communications Escape Commands The tables below list the escape commands that must be generated from the host system and the resulting action(s).

ST5770 Escape Commands Command

Action

<ESC> a

Beep (two high tones), illuminate green LED for two seconds

<ESC> b

Beep (three low tones), illuminate green LED nine times

<ESC> 1

Illuminate green LED for 135 milliseconds

<ESC> 2

Illuminate green LED for two seconds

<ESC> 3

Illuminate green LED for five seconds

<ESC> 4

One beep at low volume

<ESC> 5

One beep at medium volume

<ESC> 6

One beep at high volume

<ESC> 7

Beep (one medium tone), illuminate green LED two seconds

<ESC> 8

Beep (three low tones), illuminate green LED nine times

3-8

Page 71

Host Port Communications IT3870/IT3875 Escape Commands Command

Action

<ESC> a

Indicate as if successful menu change made

<ESC> b

Indicate as if unsuccessful menu change made

<ESC> 1

Illuminate green LED for 135 milliseconds (followed by at least 70 mSecs. dark time when multiple blinks)

<ESC> 2

Illuminate green LED for two seconds (followed by at least 500 mSecs. dark time when multiple blinks)

<ESC> 3

Illuminate green LED for five seconds (followed by at least 500 mSecs. dark time when multiple blinks)

<ESC> 4

One beep at low volume

<ESC> 5

One beep at medium volume

<ESC> 6

One beep at high volume

<ESC> 7

Indicate as successful decode and communication to host.

<ESC> 8

Indicate as unsuccessful decode and communication to host.

3-9

Page 72

Host Port Communications Decode Beep Selection Note: Decode Beep mode is active only when the programming selections Host ACK (page 3-6) or Data Format Required (page 5-27) are turned on. When Host ACK Selection is on, the scanner will only beep/blink in response to the Escape commands generated by the host. Should you also want the scanner to beep when a bar code has been successfully decoded and successfully communicated to the base, turn the Decode Beep Selection on. When Data Format Required is on, the scanner will only beep if the input data conforms to the edited format or triple beep if it does not meet the format requirements. Should you also want the scanner to beep when a bar code has been successfully read and sent to the host from the base, turn on the Decode Beep Selection.

On

*Off

3 - 10