The text of a manual · part 7 of 26
Cordless Scanning System, System Manual: SCANTEAM 2070 Base, IMAGETEAM 3870/75 Linear Imager, SCANTEAM 5770 Laser: Quick Start & Interface Menu, pages 54 to 62
Pages 54 to 62 of 232, from Cordless Scanning System, System Manual: SCANTEAM 2070 Base, IMAGETEAM 3870/75 Linear Imager, SCANTEAM 5770 Laser
The original document is the PDF (3.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST2070, HHP ST3870 and HHP ST5770
Page 54
Keyboard Style Modifiers This allows you to program special keyboard features, such as CTRL+ codes and Turbo Mode.
Control + ASCII Mode On: If you scan this selection, the cordless system sends key combinations for ASCII control characters for values 00-1F. Refer to page 8-1 for CTRL+ Values.
Control + ASCII Mode On
*Control + ASCII Mode Off
Turbo Mode: Selecting Turbo Mode On, (for the IBM AT only), programs the cordless system to send characters to the terminal faster.
Turbo Mode On
*Turbo Mode Off
Numeric Keypad Mode: Selecting Numeric Keypad Mode On sends numeric characters as if entered from a numeric keypad.
Numeric Keypad Mode On
*Numeric Keypad Mode Off
2 - 10
Page 55
Automatic Direct Connect: When Emulate External Keyboard has been selected (page 2-9), Automatic Direct Connect Mode keeps the integrated keyboard from becoming permanently disabled. (This selection disables the keyboard for the duration of the bar code transmission.)
Automatic Direct Connect Mode On
*Automatic Direct Connect Mode Off
Output Delays Selection This selection provides control of the time delays between data output by the cordless system to the host terminal. The actual delay is 5 milliseconds multiplied by the programmed value (00 - 99). Default = 00. Intercharacter Delay is the time delay between data characters output by the cordless system to the host terminal. Interfunction Delay is the time delay between function (key) codes output by the cordless system to the host terminal. Intermessage Delay is the time delay between data messages or records output by the cordless system to the host terminal. Example: You need a 45 millisecond delay. Scan the Intercharacter Delay bar code. Scan “0,” “9,” and Save on the Programming Chart (09 x 5ms = 45ms).
Intercharacter Delay (x5mS)1
Interfunction Delay (x5mS)1
Intermessage Delay (x5mS)1 1. A two-digit number and Save are required after scanning this programming bar code. Refer to the Programming Chart (inside back cover).
2 - 11
Page 56
Wand Emulation Selections Note: When in Wand Emulation mode, bar code data containing more than 48 characters may not be sent to the host device.
Transmission Rate Selection This programming selection sets the transmission rate from 10 ips (inches per second) to 300 ips if the cordless system is in Wand Emulation mode. Programming the transmission rate causes the data to be sent at the specified rate. The programmed transmission rate must be compatible with the device receiving the bar code data.
10
*25
40
80
120
150
200
300
2 - 12
Page 57
Output Polarity Selection This selection allows you to set the output logic convention for the digital output. The choices are White High and Black High.
White High
*Black High
2 - 13
Page 58
Power Settings Base Low Power Mode You may want the base unit to draw less power when it is being powered by a portable data terminal or laptop. Use Base Low Power mode to tell the base to draw less power.
*Off
On
Note: Using Base Low Power Mode increases latency in radio communications.
2 - 14
Page 59
Charge Pack Conservation Mode The scanner offers three low power modes: 1) No timeout, 2) Don’t check base network before timeout, and 3) Check base network before timeout. The lowest standby current is achieved with “No timeout” selected. Radio contact is maintained and workgroup configuration settings are maintained. “No timeout” is the default setting and is recommended if the scanner is active for most of the workday, and the charge pack is removed when the scanner is not in use.
No Timeout Product
Current
IT3870/ST5770
15 mA
IT3875
20 mA
*No Timeout
With Timeout Product
Prior to Timeout
After Timeout
IT3870/ST5770
20 mA
10 mA
IT3875
25 mA
15 mA
If “Don’t check base network before timeout” is selected and the scanner is idle. The timeout period is selectable in increments of 15 minutes up to one hour. On the next trigger-pull, the scanner begins the reassociation process to restore the radio link and the workgroup configuration settings. This setting is recommended if the scanner is left inactive for long periods of time during the workday or if the charge pack is left attached when the scanner is not in use.
Don’t Check for Network Base Before Timeout The “Check base network before timeout” mode is identical to the previous mode except that when the timeout period expires, the scanner tests whether it is still in radio contact with the base. This setting may be recommended if the charge pack is left attached and the base is powered off at the end of each working day.
Check for Network Base Before Timeout
2 - 15
Page 60
Timeout Period Selections
Timeout after 15 minutes
Timeout after 30 minutes
Timeout after 45 minutes
*Timeout after 1 hour
Low Power Timeout (IT3875 only) The IMAGETEAM 3875 enters a sleep mode when low power timeout occurs. When the scanner goes to sleep, the keypad is temporarily disabled. To wake the scanner from the sleep mode pull the trigger or press ENTER. Pressing the ENTER key wakes the system even if the executing script is not accepting keypad input.
2 - 16
Page 61
Factory Default and Revision Report Selections Reset Factory Settings Scanning the Factory Default Settings bar code resets the cordless system to the original factory settings, clearing any programming changes you may have made. You may reset the factory default settings for the current application group or for all application groups. The Current Application Group Default defaults only the settings described in Chapter 4 of this manual.
Factory Default Settings: Current Application Group The ALL Application Groups Default sets the terminal ID to 003, then changes all settings to factory default values. (See Chapter 12 for a listing of all the factory defaults.)
Factory Default Settings: ALL Application Groups
Revision Report Scan the Report Base Software Revision bar code to transmit the cordless base software revision level to the host terminal. The base software revision will be printed out as “Base software revision: X.XX, Radio: K.KK.” (The “Xs” and “Ks” will vary according to the firmware revision.)
Report Base Software Revision Scan the Report Scanner Software Revision bar code to transmit the cordless scanner software revision level to the host terminal.
Report Scanner Software Revision Scanner software and hardware revision for the IT3875 can be accessed through the System Info portion of System Setup described on page 4-5.
2 - 17
Page 62
2 - 18