Page 61

If you save your customized default results, the unit automatically enters these changes in the Output Options, Display Options line. To change the upper and lower result lines using the Display Options menu, refer to "Changing the Output Options" on page 3-12. If you customize the display, you can use the SSTR Codes to review the data quickly. You can also use the Default SSTR Code to return the display to its factory default settings.

♦ To quickly review data using SSTR Codes: 1. Scan a symbol 2. Scan the SSTR Code that contains the parameter result you want to review. The parameter result appears on the lower line of the display. To review scan results not available using a SSTR Code (check character, error messages and calculating X), use the verifier’s arrow buttons to select them. Refer to “Reviewing Scan Results” on page 4-1 for instructions on reviewing data manually.

♦ To customize the result display: 1. Scan the Install UpperLine SSTR Code. The message Upper Line Result - INSTALL - appears. 2. Scan the SSTR Code for the result that you want displayed on the upper line after a scan. 3. Scan the Install LowerLine SSTR Code. The message Lower Line Result - INSTALL - appears. 4. Scan the SSTR Code for the result that you want displayed on the lower line after a scan. 5. Scan the Save Settings SSTR Code twice. After you scan this code once, the message, CONFIRM - Scan Again for YES appears. To save the display results, rescan the Save Settings Code. If you don’t want to save the results, scan any other code.

♦ To return the customized display to the default display: 1. Scan the Default SSTR Code. After you scan a symbol, the default display appears. If you set the test criteria option to ISO/IEC, it has the ISO/IEC defaults; if you set the test criteria to Traditional, it has the traditional defaults.

Using the Quick Check Verifier as a Reflectometer Your verifier is capable of functioning as a static reflectometer. This capability is especially useful to investigate the underlying reflectance characteristics of bar code symbols or for testing the reflectance of potential bar (for example, ink) and space (for example, substrate) components.

Quick Check® 600/800 Series User’s Guide

4 - 17

Page 62

When using the reflectance mode, the reflectance “seen” by the unit is continuously shown on the verifier’s display as both a two-digit reflectance percentage (from 0% to 99%) and on a graphic bar graph (gas gauge). For meaningful and consistent static reflectance values, you must calibrate the unit and hold the wand at the proper scan angle with its “foot” just touching the symbol. For information on proper scan technique and calibration, see Chapter 2, Quick Start Guide.

♦ To use the Quick Check Verifier as a static reflectometer: 1. Recalibrate the Quick Check Verifier if the calibration has not been performed recently. 2. Press SELECT to display the menu with the term Print Results on top. 3. Press ↓ to move the cursor next to Reflectom’r. 4. Press SELECT. The display changes to show the percent reflectance in large letters on the left of the display. The term Reflectance appears below the reading and a bar graph appears on the right of the display.

4 - 18

Quick Check® 600/800 Series User’s Guide

Page 63

5

Saving and Printing

Saving Data When you scan a bar code symbol and you do not have a printer connected to the Quick Check 600/800 Verifier, or a printer is connected but not turned on, you can store or save, the scan results in the verifier’s print buffer. You can print the stored results at a later time. There are two ways to save data, using the AutoPrint/Store feature or through the Print Results menu.

♦ To save scan data: 1. Set the AutoPrint/Store feature to On. Refer to the instructions in Chapter 3, Changing the Settings for changing the settings. 2. Scan a bar code symbol. The verifier automatically saves the results in its print buffer. OR 1. Scan a bar code symbol. 2. If the AutoPrint/Store feature is set to Off, press SELECT three times. • Pressing SELECT the first time displays a menu that begins with Print Results and the cursor is on the asterisk next to Print Results. • Pressing SELECT a second time displays a message stating that a printer is not attached and asks if you want to store the data. • Pressing SELECT a third time saves the data. The verifier saves the results in its print buffer.

Checking the Print Buffer During Operation When you turn on the Quick Check 600/800 Verifier, a message appears if there are records stored in its print buffer. You can also check the print buffer status during operation, called “on-demand checking.” The print buffer display provides both the percent of the memory used for the stored records and the number of scan or profile records in the memory. The amount of data you can store in the buffer depends on the symbology type and the number of encoded data characters. In some cases when you are saving scan profile data, memory may be almost full with data from just a few scans. In other cases, the buffer may contain data from hundreds of scans, but only be 50% full. The unit can store approximately 2000 scans of U.P.C.-A code. When the buffer reaches capacity, a full buffer message appears.

Quick Check® 600/800 Series User’s Guide

5-1

Page 64

♦ To check the print buffer during operation: 1. Display the menu that begins with Print Results. If scan results are displayed on the verifier, press SELECT. If a menu (for example, a change setting menu) is displayed on the verifier, press POWER repeatedly. 2. Press POWER. 3. Press ↑. The on-demand print buffer display screen appears. The display provides the percent of the memory used for the stored records and the number of scan records in the memory. You can respond in one of three ways: a.) Cont., b.) Prnt or c.) Cir. The cursor is at the asterisk next to Continue. 3.a To continue obtaining scan results, press SELECT. The opening display appears. You can then scan a symbol. 3.b To print the stored records, press → to place the cursor on the asterisk next to Print. Then press SELECT. The stored records print. Once printed, the stored results are removed from the verifier’s memory; however, the results from the last scan remain in the buffer. (Press ← to display the last scan’s results.) 3.c To clear (delete) the records stored in the memory, press → twice to place the cursor on the asterisk next to Clear and then press SELECT. The stored results and the results from the last scan are deleted from the verifier’s memory.

Printing Data When a printer is attached to the verifier and turned on, you can print the current scan results stored in the buffer. For this discussion, “current data” are data from a scan that you just took and whose results are on the verifier’s display, or data from a scan that you will perform momentarily. “Stored data” are scan records stored or saved in the buffer. There are two ways to print current data, using the AutoPrint/Store feature or through the Print Results menu. There are also two methods to print stored data, through the Print Results menu or through the Print Buffer menu. To print results, the Printer type (QCP or QCHSP) in the Printer Options menu must match the type of printer you have connected to the verifier. If the connected printer and the displayed printer abbreviation do not match, the printout will be illegible.

♦ To print current data: 1. Connect the verifier and the printer and turn on both units. Be sure the Printer type setting in the Output Options, Print Options menu matches the type of printer to which the verifier is connected. Refer to "Changing the Output Options" on page 3-12 for instructions.

5-2

Quick Check® 600/800 Series User’s Guide

Page 65

2. Scan a bar code symbol. - If the AutoPrint/Store feature is set to On, the results print. - If the AutoPrint/Store feature is set to Off, press SELECT twice. After you press SELECT the first time, a menu that begins with Print Results appears and the cursor is on the asterisk next to Print Results. After you press SELECT a second time, a message appears that asks if you want to print all the stored results, print just the results of the last scan or if you want to clear the buffer. 3. Press ↓ to move the cursor next to Latest Result Only. 4. Press SELECT. The data prints.

♦ To print stored data: 1. Connect the verifier and the printer and turn on both units. Be sure the Printer type setting in the Output Options, Print Options menu matches the type of printer the verifier is connected to. Refer to "Changing the Output Options" on page 3-12 for instructions. 2. With any data displayed on the verifier, press SELECT three times. After you press SELECT the first time, a menu that begins with Print Results appears and the cursor is on the asterisk next to Print Results. After you press SELECT a second time, a message appears that asks if you want to print out all the stored results, print just the results of the last scan or if you want to clear the buffer. The cursor appears next to All Stored Results. After you press SELECT the third time, the stored data prints. OR 1. Display the print buffer message. Refer to "Checking the Print Buffer During Operation" on page 5-1 for instructions. 2. Use the arrow buttons to move the cursor to the asterisk next to Print. The stored data prints and clears the records from the buffer, but the data from the last scan remains in the verifier.

♦ To stop printing: 1. During printing, press and momentarily hold POWER on the verifier. Printing stops when the printer’s internal buffer is clear. OR 2. Wait until the printer stops automatically.

Deleting Stored Data You can delete stored data from the verifier’s memory using the Print Buffer menu or the Print Results menu.

Quick Check® 600/800 Series User’s Guide

5-3

Page 66

♦ To delete stored data: 1. Connect your printer to the verifier and turn on both units. The opening display appears. 2. A PRINT BUFFER message appears asking if you want to continue, print or clear. 3. Press ↓ and then → to move the cursor next to Clear. 4. Press SELECT. The results stored in the verifier and the data from the last scan are deleted. If you don’t want to clear the stored results, move the cursor next to Cont and press SELECT. OR 1. Connect your printer to the verifier and turn on both units. The opening display appears. 2. When you select the Print Results menu, a menu appears asking if you want to print All Stored Results, the Latest Stored Results Only or Clear Buffer!. 3. Press ↓ to move to select Clear Buffer!. 4. Press SELECT. The results stored in the verifier and the data from the last scan are deleted. If you don’t want to clear the stored results, move the cursor next to Cont and press SELECT.

Interfacing With a Computer You can use the QCViewerII software and print to a local or network printer, or connect the verifier to an RS-232 serial communication device using the larger port on the back of the unit and a QCDB09F cable. If you have the appropriate computer software, you can display the verifier data on your computer. Contact Hand Held Products for additional information about connecting the verifier to a computer.

Reviewing the Printouts All the information presented on the printout is also available on the display after you scan a bar code symbol. Refer to Chapter 4, Reviewing Scan Data for information on displaying this data.

5-4

Quick Check® 600/800 Series User’s Guide

Page 67

QCP and QCHSP Printouts ***Quick Check 600*** 660 nm, 06 mil Scanner Interleaved 2/5 123456 - Extended Accuracy! Avg Bar Err = -.05X Wide/Nar Ratio = 2.5 Decodability = 53% Symbol Total = 055”X” Prnt Contr Sig = 92% Reflect(Light) = 86% Reflect(Dark) = 05% Symbol Contrst = 81% R(min)/R(max) = 06% Modulation = 91% EdgeContr(min) = 73% “Defects” = 05% Message Length = 06

OK! OK! <B> OK! OK! OK! <A> <A> <A> <A> <A> OK!, No Check Character, Bar Growth IN TOL “P C S” OK Traditional Tests -PASSFormat Tests -PASSISO/IEC Parameters Add’l P/F Checks Format Checks Profile Quality Grade Passing Level: ISO/IEC ==> ScanProfile PASSES

<B> <P> <P> <B> <C>

Symbol Grade Avg. 4.0 => A/06/660 After 002 of 010 Scans Name: Date:

Quick Check® 600/800 Series User’s Guide

5-5

Page 68

Printing Guidelines The verifier supports two different Hand Held Products serial printers: • Quick Check® Standard Speed Printer (QCP) • Quick Check® High Speed Printer (QCHSP) The QCP and QCHSP are both impact printers. When you first receive your printer, you should unpack it carefully. Before attempting to use it, inspect the contents of the package for any shipping damage. If there is evidence of damage, please keep ALL packing materials and contact the delivery carrier as soon as possible for the claim procedure. Confirm that you have the following items: • Printer • One roll of paper • Power supply For optimal printer performance, follow these general guidelines for any type of printer: • Never place the printer where it is exposed to direct sunlight. • Never apply power while you are plugging or unplugging an input connector. • Do not print without paper or a ribbon because this may damage the print head. • Do not subject the printer to temperatures below 5° C or above 40° C during operations or to a sudden change in temperature. • Insert the connectors so that a slight pressure seats the cable properly. Never force the connectors because this could damage the cable.

Using the QCP or QCHSP The QCP and QCHSP models are shown on page 5-7.

5-6

Quick Check® 600/800 Series User’s Guide

Page 69

Quick Check Printer (QCP) and Quick Check High Speed Printer (QCHSP) A three-position power switch on the printer’s front panel determines its function: Switch Position

Function

Down Left Center Down Right

Off On Paper Feed

A red light-emitting diode (LED) to the right of the power switch lights to indicate the On and Paper Feed states. The printer has a VAC transformer with an 8-foot cord. The power transformer cord has a transformer on one end and has a mating connector to the printer on the other end. An interface cable connects the printer directly to the verifier to provide easy exchange of scanning results. The connectors on each end of the cable are keyed so that they cannot be plugged in the wrong way.

Quick Check® 600/800 Series User’s Guide

5-7

Page 70

The printer has a replaceable cartridge ribbon. Replace the paper roll when it is empty.

♦ To turn on and off the QCP or QCHSP: 1. To turn on the printer, press the power switch into the On (center) position. 2. To turn off the printer, press the power switch into the Off (down left) position. After you turn off the printer, wait at least three seconds to turn on the power for the proper initialization procedure.

♦ To set up the QCP or QCHSP: 1. Place the printer on a hard, flat surface such as a table or desk top. 2. Press the power switch into the Off (down left) position. 3. Plug the power connector from the transformer into the printer. 4. Plug the transformer into a VAC wall outlet.

♦ To install or replace the QCP or QCHSP paper roll: 1. Press the printer power switch to the Off (down left) position. 2. Remove the printer cover by locating the four small grooves embossed on each side of the printer cover and tilting the cover open by pushing down gently on both sets of these grooves. 3. If necessary, remove the empty roll. Press and hold the power switch in the Paper Feed (down right) position to advance the paper about one inch beyond the paper cutter. Lift the empty roll from the printer housing. Do not pull paper out of the back of the printer as this will damage the mechanism. WARNING 4. Unroll several inches of paper from a new roll and cut a straight edge on the paper if it is jagged or wrinkled. (A straight edge helps guide the paper into the printer.)

5-8

Quick Check® 600/800 Series User’s Guide