Page 31
6. To change which symbology has a W/N Ratio: Press ↑ or ↓ to set the cursor on the asterisk next to Fixed W/N Ratio and then press SELECT. A menu appears with Fixed W/N Ratio on top and asks you to choose the symbology name and the ratio amount. • To choose the symbology, press SELECT or → to move the cursor from the asterisk next to Symbgy to the name of the specific symbology. You can set the W/N ratio for only one symbology at a time. Now press ↑ or ↓ to display the symbology that you want to have a fixed W/N ratio. • To save the selection, press SELECT or ← to move the cursor back to the asterisk next to Symbgy. • To set the fixed W/N ratio amount, press ↓ to move the cursor to the asterisk next to Ratio. Then press SELECT or → to move the cursor to the numeric value. Use ↑ or ↓ to display the value you want. The value can range from 1.4 to 3.9 ± 0.2. • To save the selection, press SELECT or ← to move the cursor back to the asterisk next to Ratio. • To return to the previous menu, press POWER. 7. To change which symbology has a fixed message length: •
Press ↑ or ↓ to set the cursor on the asterisk next to Fixed Len and then press SELECT. A menu appears with Fixed Message Length on the top and asks you to choose the symbology name and the specific length. • To choose the symbology, press SELECT or → to move the cursor from the asterisk next to Symbgy to the name of the specific symbology. Now press ↑ or ↓ to display the symbology that you want to have a fixed message length. • To save the selection, press SELECT or ← to move the cursor back to the asterisk next to Symbgy. • To set the specific length, press ↓ to move the cursor to the asterisk next to Length. Then press SELECT or → to move the cursor to the numeric value. Now press ↑ and ↓ to display the value you want. The length can range from 0 to 255 characters. (See "Symbology Specifications" on page 3-3.) • To save the selection, press SELECT or ← to move the cursor back to the asterisk next to Length. • To return to the previous menu, press POWER. 8. To change other symbologies and their parameters, repeat step 5. on page 3-6. •
• •
To return to the previous menu, press POWER. To scan a symbol, set the wand on the symbol’s quiet zone.
Industry Applications You can enable only one application at a time. Your verifier may not have all the applications installed in it.
Quick Check® 600/800 Series User’s Guide
3-7
Page 32
♦ To select an application: 1. Display the menu that begins with Print Results (press POWER and SELECT). 2. Set the cursor on the asterisk next to Change Settings and then press SELECT. A menu that begins with Specifications appears. 3. With the asterisk next to Specifications, press SELECT. A menu that begins with Symbologies appears. A list containing the term Symbologies and the names of the applications appears. The application that is currently enabled has a ← to the right of the name. If a → is to the right of the term Symbologies, no application is enabled. 4. To enable another application, set the cursor next to the application name and then press SELECT. • When you select AIAG, SCC, Coupon Code or BOOKLAND, you are prompted to provide additional information. AIAG asks if you want Supplier or Customer. Use ↑ and ↓ to set the cursor on the asterisk next to the term you want and then press SELECT. • When you select SCC for the SCS/ITF, Coupon Code and BOOKLAND, you are prompted to provide a magnification factor. Use ↑ and ↓ to display the magnification factor you want to use and then press SELECT. 5. To return to the previous menu, press POWER. To scan a symbol, set the wand on the symbol’s quiet zone.
Changing the Test Criteria The test criteria apply to the standards used to evaluate the scanned symbols. You can select the following items: • • • •
ISO/IEC scan grade or pass/fail criteria for traditional parameters Character averaged decodability or ISO/IEC Decodability ISO/IEC grades in letters or numbers Number of scans used to determine the final ISO/IEC Symbol Grade
Scan Grade The Quick Check 600/800 Verifier acquires data using the ScanProfile Methodology specified in the ISO/IEC’s “Bar Code Print Quality Guideline.” The verifier then evaluates the acquired data and provides a scan grade (also called a scan profile grade). The default number of scans used to obtain the scan grade is one (with Extended Accuracy set to Off). You can obtain an averaged scan grade when the Extended Accuracy scanning option is On (set to a value >1).
3-8
Quick Check® 600/800 Series User’s Guide
Page 33
You can obtain the scan grade result in two ways: • Set the verifier to use traditional print quality parameters to make a pass/fail judgment about the symbol and provide detailed measurements. • Set the verifier to use ISO/IEC methods to judge the symbol and report an ISO/IEC scan grade of A, B, C, D or F. The default setting is ISO/IEC scan grade C. All the test criteria options are available for you to select regardless of which scan grade method (ISO/IEC or traditional) you selected. For example, if you select the traditional pass/fail criteria, you can view and change the ISO/IEC grade letter or number option, even though it has no affect on the traditional criteria you selected.
Decodability Decodability is the percentage of the symbology’s safe decoding margin available for the scanner after printing errors. Lower margin values and corresponding lower grades indicate an increased susceptibility to decoding failure due to scanning errors. Scanning variations, such as acceleration, cause bar or space deviations due to uneven, too fast or too slow scanning and could yield lower margin values. You can choose the decodability method you want to use, ISO/IEC Decodability or character averaged decodability (Avg): • ISO/IEC Decodability is a graded measure of how close a given scan comes to a reference decode failure due to variations in bar and/or space widths. The default setting is ISO/IEC decodability. • Avg is the character-averaged value of decodability and is referred to as “D Margin” on a Quick Check 600/800 Verifier printout.
ISO/IEC grades For all symbologies, and most of the applications, you can view the test results, ISO/IEC scan grade and ISO/IEC symbol grades reported as letters (A, B, C, D, or F) or as numbers (4, 3, 2, 1, or 0). The default setting is letters, with A=4, B=3, C=2, D=1, and F=0. For some applications, such as AIAG, the grade level is specified by the application and you cannot change it. If you set an incorrect grade level, the application resets the correct one.
Number of Scans You use the #Scans/Symbol setting to specify the number of individual scan grades that you want used to calculate the final symbol grade. The term “#Scans/Symbol” is shorthand for the number of scan grades used to determine the final symbol grade. For further discussion and comparison to scan grades, refer to "Reviewing Scan Results" on page 4-1. You can select from the following settings: 1 through 10, 12, 15, 20, 30, 50, 100 and Var. The default #Scans/Symbol setting is 10.
Quick Check® 600/800 Series User’s Guide
3-9
Page 34
Consider the symbol grade as the average resulting from scans you take from all over the symbol. The ISO/IEC standard requires you to obtain ten scans of each symbol. For example, you might sample the symbol at ten different paths in the symbol, four in the upper portion, two in the middle and four in the lower portion. Multiple scans of the same symbol across different scan paths take advantage of the vertical redundancy of bar codes and give you a more accurate value of the symbol’s overall print quality.
♦ To change the test criteria: 1. Display the menu that begins with Print Results (press POWER and then SELECT). 2. Set the cursor on the asterisk next to Change Settings and then press SELECT. A menu that begins with Specifications appears. 3. Set the cursor on the asterisk next to Test Criteria and then press SELECT. A menu that begins with Passing appears. • To change the pass/fail criteria, set the cursor on the asterisk next to the term Passing and then press SELECT or →. The cursor moves to the right of Passing. Press ↑ and ↓ until the grade (Trad’l, ISO/IEC “A,” ISO/IEC “B,” ISO/IEC “C,” ISO/IEC “D,”) you want appears. To save the selection, press SELECT, POWER or ←. The cursor moves back to the asterisk next to Passing. • To change the Decodability, set the cursor on the asterisk next to Decodability and then press SELECT or →. The setting changes between ISO/IEC and Avg. • To change the Grades, set the cursor on the asterisk next to Grades and then press SELECT or →. The setting changes between Letters and Numbers. • To change the number of scans used to determine the final ISO/ IEC Symbol Grade, set the cursor on the asterisk next to #Scans/ Symbol and then press SELECT or →. The cursor moves to the right of the terms #Scans/Symbol. Press ↑ and ↓ until the numeric value you want (1 through 10, 12, 15, 20, 30, 50, 100 or Var) appears. To save the selection, press SELECT or ←. The cursor moves back to the asterisk next to #Scans/Symbol. When you exit any menu (press POWER), all the displayed parameter choices are saved. 4. To return to the previous menu, press POWER. To scan a symbol, set the wand on the symbol’s quiet zone.
Changing the Scanning Options The scanning options apply to the general operation of the Quick Check 600/800 Verifier. You can change the following options:
3 - 10
Quick Check® 600/800 Series User’s Guide
Page 35
• Beeper Pitch (raise or lower) • Extended Accuracy • Decoding direction (both ways or forward only)
Beeper Pitch You can change the pitch of the verifier’s beeper. Higher pitches seem to sound louder. You can also turn off the tone. The default is 16. The range includes Off and 1 through 31.
Extended Accuracy The Extended Accuracy setting is the number of scans of the same symbol, taken at the same path in the symbol, that yields the scan grade. • With Extended Accuracy on, individual parameter measurements and results are averaged over successive scans of the symbol. Using the extended accuracy mode greatly reduces reading variability due to variations in scanning motion and minor scan path variations. When Extended Accuracy is on, you select the number of scans for the averaged result from 2 through 10, 12, 15, 20, 30, 50 and 100. • When Extended Accuracy is off (set to one), each scan of the symbol gives the measured results. The default is Extended Accuracy turned off. When you scan a symbol with Extended Accuracy on, a numeric counter appears on the display telling you how many additional scans of the same path you must obtain. After you satisfy the setting, the scan grade appears. If you do not scan the same symbol within five seconds, the unit assumes you do not want to satisfy the Extended Accuracy setting you chose and displays the scan results from that individual scan. If you scan a different symbol after your first scan, the Extended Accuracy counter resets. For further discussion and comparison of scan grade to symbol grade, refer to Chapter 4, Reviewing Scan Data.
Decode Direction You can set the Quick Check 600/800 Verifier to read bar code symbols from leftto-right, called “forward only,” or from either direction, called “Both Ways.” The BothWays setting (default) makes scanning easier and more flexible than forward-only scanning.
♦ To change the scanning options: 1. Display the menu that begins with Print Results (press POWER and SELECT). 2. Set the cursor on the asterisk next to Change Settings and then press SELECT. A menu that begins with Specifications appears.
Quick Check® 600/800 Series User’s Guide
3 - 11
Page 36
3. Set the cursor on the asterisk next to Scanning Options and then press SELECT. A menu that begins with Beeper Pitch appears. 4. To make any necessary changes: •
To change the beeper pitch, set the cursor on the asterisk next to Beeper and then press SELECT or →. The cursor moves to the right of the term Pitch. Press ↑ and ↓ until you hear the beeper pitch you want. To save the selection, press SELECT or ←. The cursor moves back to the asterisk next to Beeper. • To change the Extended Accuracy setting, set the cursor on the asterisk next to Extended Accur and press SELECT or →. The cursor moves to the right of Accur. Press ↑ and ↓ until the number of scans you want for the average appears. To save the selection, press SELECT or ←. The cursor moves to the asterisk next to Extended. • To change the decoding direction setting, set the cursor on the asterisk next to Decoding and then press SELECT or →. The setting changes between BothWays and FwdOnly!. • When you exit any menu, all the displayed parameter choices are saved. 5. To return to the previous menu, press POWER. To scan a symbol, set the wand on the symbol’s quiet zone.
Changing the Output Options The output options include the display options and the print options.
Display Options The display options include: • • • •
Upper Parameter Result Line display Lower Parameter Result Line display Error Override display LEDs either display ISO/IEC Grade or indicate bar growth or loss
The display options allow you to set the two types of results that are most important to you in the upper and lower parameter result lines so they appear immediately after a scan. (The upper parameter result line is the third line of the display and the lower line is the fourth or bottom line of the display.) Then, by pressing a few buttons, you can review all the other results.
Parameter Result Lines On the parameter lines, you can display either the result defaults set at the factory, or results you select. • For traditional pass/fail criteria, the factory-set defaults are PCS and AvgBar. • For ISO/IEC criteria, the factory-set defaults are Decodability and Modulation.
3 - 12
Quick Check® 600/800 Series User’s Guide
Page 37
Additional results you can display and the criteria used include: • • • • • • • • • •
Symbol type Wide-to-narrow ratio (traditional) Light reflectance (traditional and ISO/IEC) Dark reflectance (traditional and ISO/IEC) Symbol contrast (ISO/IEC) Reflectance minimum/maximum (ISO/IEC) Edge contrast minimum (ISO/IEC) Defects (ISO/IEC) Message length Bar growth (traditional)
Error override allows you to set the verifier to replace the default or user-selected Upper and Lower Parameter Result lines with any error information or messages that might result from the bar code scan analysis. If more than two errors result from a scan, the first two appear on the display and you can scroll the display to view the other errors. The default for Error Override is NO. When you select ISO/IEC criteria, you can use the LED’s display feature to set the LEDs to indicate bar growth/loss or pass/fail grade and result grade. In addition, when you select ISO/IEC criteria, the five multi-colored LEDs normally indicate symbol pass or fail based on the ISO/IEC criteria. With the LED feature set to Bar Growth, the LEDs provide information on bar growth or loss, just as they would if you selected traditional pass/fail test criteria.
Print Options The print options allow you to select: • Printer type (QCP or QCHSP) • Printout form (long or short) • Automatic options, automatically print data when the unit is connected to a printer and turned on, automatically store data when the unit is not connected to a printer • Auto Print/Store with or without Profile You can use any one of the three optional accessory hardcopy printers, but you need to select the printer before you try to print. Supported printers include: • QCP (standard printer) • QCHSP (High-Speed Printer) Refer to Chapter 5, Saving and Printing for more information about these printers.
AutoPrint/Store The AutoPrint/Store option automatically prints or stores your data: • When you have the AutoPrint/Store feature turned on and a printer connected to your verifier and turned on, your scan results print automatically. You cannot store results when a printer is connected and turned on.
Quick Check® 600/800 Series User’s Guide
3 - 13
Page 38
• When you have the AutoPrint/Store feature turned on, but no printer is connected to your verifier, or your printer is connected, but is turned off, your scan results are automatically stored in the verifier’s memory. • When you have the AutoPrint/Store feature turned off, after each scan you need to instruct the verifier to print your data (if a printer is connected and turned on) or to store your data (if a printer is not connected or is turned off). The default is setting for AutoPrint/Store is ON.
Scan Profile The Quick Check 600/800 Verifier allows you to print the scan profile which is a record of the reflectance values seen by a scanner as it moves across a symbol. The scan profile is the basis of ISO/IEC evaluation and is usually presented in a graphic form. • When you use the AutoPrint/Store feature with Profile, you can choose to have the scan results stored so you can later print a graphic scan profile on a printout. • When you use AutoPrint/Store without Profile, the raw data is not stored.
♦ To change the output options: 1. Display the menu that begins with Print Results (press POWER and then SELECT). 2. Set the cursor on the asterisk next to Change Settings and then press SELECT. A menu that begins with Specifications appears. 3. Set the cursor on the asterisk next to Output Options and then press SELECT. A menu that contains Display Options and Printout Options appears. 4. To change the display options: • •
• • •
3 - 14
To change the display options, set the cursor on the asterisk next to Display Options and then press SELECT. A menu with four display options selections appears. To change the data displayed in the upper (3rd line) or the lower (4th line) parameter result line, set the cursor on the asterisk next to UpperLine and then press SELECT or →. The cursor moves to the right of the term. Press ↑ and ↓ until the name of the data that you want to show up on the parameter result line appears. To save the selection, press SELECT or ←. The cursor moves back to the asterisk next to the term. To change the error override feature, set the cursor on the asterisk next to Error Override and then press SELECT or → until the setting you want, YES (Y) or NO (N), appears. To change what the LEDs indicate, set the cursor on the asterisk next to LEDs and then press SELECT or → until the setting you want, P/F Criteria or Bar Growth!, appears. Press POWER to return to the menu that contains Display Options and Printout Options.
Quick Check® 600/800 Series User’s Guide
Page 39
5. To change the printout options: •
To change the printout options, set the cursor on the asterisk next to Printout Options and then press SELECT. A menu with the printout options selections appears. • To change the printer type, set the cursor on the asterisk next to Printer Type and then press SELECT or → until the setting you want, QCP or QCHSP, appears. • To change the printout form, set the cursor on the asterisk next to Printout and then press SELECT or → until the setting you want, Long or Short, appears. • To change the AutoPrint and Store setting, set the cursor on the asterisk next to AutoPrint/Store and then press SELECT or → until the setting you want, On or Off appears. If you set the AutoPrint and Store setting On, you may want to use it with or without Profile. To change the Profile settings, set the cursor on the asterisk next to w/Profile?. Press SELECT or → until the setting you want, Yes or No, appears. 6. To return to the previous menu, press POWER. To scan a symbol, set the wand on the symbol’s quiet zone.
Resetting the Default Settings If you make changes to your Quick Check 600/800 Verifier’s settings, you can easily reset them to the factory installed defaults.
♦ To reset a unit: 1. Scan the special “Reset All Options” code located in Chapter 12, Special Codes. The unit reinstalls the factory default settings. 2. Recalibrate the unit. Refer to Chapter 2, Quick Start Guide for instructions.
Locking the Settings After you set all the options (specifications, test criteria, scanning options and output options) on the Quick Check 600/800 Verifier, you can “lock” the unit so that you or others cannot accidentally change the settings during routine use. If you lock the unit, you must unlock it to change any settings. Use the Special Codes provided in the back of this manual to lock and unlock the unit. The verifier is shipped in the unlocked mode.
♦ To lock the unit: 1. Customize your verifier by setting all the options the way you want them. 2. Scan the “Lock Specs and Tests” Special Code. The unit is now locked. You cannot change any option settings unless you unlock the unit or scan "Reset All Options" which sets the unit to its factory defaults.
Quick Check® 600/800 Series User’s Guide
3 - 15
Page 40
♦ To unlock the unit: 1. Scan the “Unlock Specs and Tests” Special Code. The unit is now unlocked. You can now change any option setting.
Using a Command Code A Command Code is a bar code symbol that allows you to customize the Quick Check 600/800 Verifier for your use. It is especially useful when you have one or two setups and you frequently switch between them. After you turn on the unit or when you want to change setups, just scan your customized Command Code for that type of operation and then begin your work.
About Command Codes There are two different types of Command Codes, Command- (Minus) Codes and Command+ (Plus) Codes. These codes differ in the type of information they store. • Command+ Codes let you store all the settings on the “Command Code Selections Lists” below. • Command- Codes allows you to store all the settings listed on the Command Code selection list except the beeper pitch, the decode direction and the output option settings (printer type, printout form and the AutoPrint/Store setting). Command Code Selections List Test Criteria Passing grade: (Choose One) Traditional or ISO/IEC “A,” ISO/IEC “B,” ISO/IEC “C,” ISO/IEC “D” Decodability: Avg or ISO/IEC Grades: Letters or Numbers Number or scans/symbol: (Choose one) 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 15, 20, 30, 50, 100, Var Scanning Options Beeper Pitch: (Choose One) Off or value between 1 and 31 Extended Accuracy: (Choose One) Off, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 15, 20, 30, 50, 100, Var Decoding Direction: BothWays or Forward Only Output Options Display Options UpperLine: (Choose One) Default or Average Bar Error, W/N Ratio, Decodability, RI & RD, P.C.S., Symbol Contrast, Rmin/Rmax, Modulation, EC(min), Defects, Message Type, Message Length or Check Character LowerLine: (Choose One) Default or Average Bar Error, W/N Ratio, Decodability,
3 - 16
Quick Check® 600/800 Series User’s Guide