Quick Check 200 Series User's Guide, pages 21 to 30

Pages 21 to 30 of 84

The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC QC-200 and HHP QC-210

Page 21

4.0 Configuration/Programming The Quick Check 200 Series auto-recognizes or “autodiscriminates” seven bar code symbologies - - Codabar, Code 39, Interleaved 2/5, EAN/UPC, Code 128, MSI Code and Code 16K - - or alternately can check that symbols conform under any or all of several applications specifications; AIAG, BOOKLAND, CCBBA, Comp Tia/CTIA, SCC, SISAC, U.P.C.-COUPON CODE, dependent upon the QC200 Model. The QC200 also has a number of operator selectable test and configuration options. The QC200 user can program their unit for all of these options in two distinct ways. One is by simply scanning a specialized Code 128 called a Command Code. Predetermined Command Codes were used in the QC200 Quick Start section of this manual and are explained in a later section. The QC200’s options can also be programmed manually. The “heart” of the operation and manual programming of the Quick Check 200 Series is centered around its “Select” and “Scroll” buttons. All functions with the QC200 are controlled by their use. Generally, pressing the Select [0] Button moves the user from menu “level” to menu “level”. Pressing of the Scroll [<>] Button allows the user to pick an option within these levels. At the end of the manual are menu “flow charts” of the QC200 menu sequences. An explanation of what programmable selections are available follows. 4.1 Codes/Symbology Options The Quick Check 200 Series symbology selection configuration is set and controlled from within the QC200’s programming menu structure, this is entered after power up by pressing the Select [0] Button two times as demonstrated through the next steps: On power up, [Qc2xx aa/lll] is displayed. If you press the Scroll [<>] Button the results of the last scan is displayed (the QC200 always stores the last sample scan). If you press the Select [0] Button the following is displayed: 13

Page 22

[Reflectom’r>] This is the QC200’s static Reflectometer option, which is described later in this manual. Pressing the Select [0] Button again bypasses this and changes the LCD to: [- Specs - >] The “>” indicates to the user that pressing the Scroll [<>] Button will allow them to select between the different code “specifications” (generic symbologies vs. applications) preprogrammed into the QC200. If you press Scroll [<>] here, you are put into the “Codes” (generic symbologies) mode with a resulting LCD of: [ - Codes - >] Here you will be allowed to make certain modifications in the testing criteria used for the generic symbologies. These choices are also accepted or by-passed using the Select [0] and Scroll [<>] buttons. Pressing Select [0] will bring up the first set of options: Codabar Options displayed on the LCD are: [USS – Codabr>] or [Trad Codabr>] This choice is between the original constant character width Codabar font (with Monarch’s original print tolerances applied) and the compatible “rationalized” font described in AIM’s USS – Codabar specification (with the appropriate USS tolerances applied). NOTE: An “x” shown during Codabar decoding indicates a missing stop/start character. Code 39 Options displayed on the LCD are: [Cod39 no Ck>] or [Code39 w/Ck>] This choice is whether to test for Code 39’s optional Mod 43 Check Character (see AIM USS for Code 39). Interleaved 2/5 Options displayed on the LCD are: [Int25 no Ck>] or [Int25 w/Ck>] 14

Page 23

This choice is again whether to test for an optional Interleaved 2/5 Mod Check Character. UPC/EAN/JAN Options displayed on the LCD are: [UPC/EAN x.x>] where “x.x” represents a UPC/EAN magnification factor. The possible choices are .80, .85, .90, .95, 1.0, 1.2, 1.4, 1.6, 1.8 or 2.0 and are cycled through by repeatedly pressing the Scroll [<>] Button. The default setting is 1.0 or 100%. Code 128 Options displayed on the LCD are: [Cd128 Modes>] or [Cd128 Messg>] This choice is whether or not to have Special Extra Characters displayed and printed within the encoded message that show Code 128’s Starting Mode, Mode Changes and Shifts. Normally this information is totally transparent to the user but it may assist in analyzing reading or printing problems. When scanning Code 128 in the “Show Modes” setup, the LCD display and the printer “show” Code 128’s “Special Extra Characters” as well as information on the symbol’s check digit. Because of the nature of some of these characters, they are represented by special character “strings” as shown in the following table.

15

Page 24

CODE 128 CHARACTER TRANSLATION TABLE CHARACTER 00(NUL) 01(SOH) 02(STX) 03(ETX) 04(EOQ) 05(ENQ) 06(ACK) 07(BEL) 08(BS) 09(HT) 0A(LF) 0B(VT) 0C(FF) 0D(CR) 0E(SO) 0F(SI) 10(DLE) 11(DC1) 12(DC2) 13(DC3) 14(DC4)

LCD 0 1 2 3 4 5 6 7 8 9 A B C D E F 10 11 12 13 14

PRINTER <NL> <SH> <SX> <EX> <ET> <EQ> <AK> <BL> <SC> <HT> <LF> <VT> <FF> <CR> <SO> <SI> <DE> <D1> <D2> <D3> <D4>

CHARACTER 15(NAK) 16(SYN) 17(ETB) 18(CAN) 19(EM) 1A(SUB) 1B(ESC) 1C(FS) 1D(GS) 1E(RS) 1F(US) 7F(DEL)

LCD 15 16 17 18 19 1A 1B 1C 1D 1E 1F *

PRINTER <NK> <SY> <EB> <CN> <EM> <SB> <ES> <FS> <GS> <RS> <US> <DL>

FCN1 FCN2 FCN3 FCN4 Mode A ModeB ModeC Shift

F1 F2 F3 F4 A B C Sh

<F1> <F2> <F3> <F4> <A:> <B:> <C:> <Xh>

* - No “special” displayed character for <DEL> Code 16K Options displayed on the LCD are: [Cd16K Modes>] or [Cd16K Messg>] Selection here is similar to that described under Code 128. When scanning a Code 16K symbol, the QC200 reports quality information on each individual row of the code. After the appropriate number of rows has been decoded, the QC200 will also output the complete Code 16K encoded message. Note that Code 16K uses many of the same special character “strings” as those listed for Code 128. An additional character, the “Pad” character is shown as Pd on the LCD and printouts.

16

Page 25

MSI Code Options displayed on the LCD are: [MSI NoUsrCk>] or [MSI Mod10Ck>] or [MSI Mod11CK>] which allows the selection of no user specified second check digit or a user specified second check digit of either the Modulo 10 or Modulo 11 type. NOTE: The MSI “System” Check Digit, which is inherent to the code, is displayed on the Quick Check’s LCD line after decode. In some cases it may not be shown as a “human readable” digit on printed samples. If, after the initial LCD output of “- Codes - >”, the Scroll [<>] Button is pressed twice, the operator is then prompted to select an application specification. 4.2 “Application”/Model Options A QC200 is preprogrammed with Industry Applications according to the Model selected. These application tests not only test the codes for generic print quality parameters, as applied by the applications, but also test for application specific formats, check characters and data identifiers. The selection of an application is accomplished by turning on the QC200. [QC2xx aa/lll] where “xx” identifies the model number. Continue by pressing the Select [0]button two (2) times. [ - Specs - >] is displayed. Press the Scroll [<>] button [ - Codes - >] is the next display. Continue by pressing the Scroll [<>] button until the Industry Application of choice is display. (message displays for each application are found on page 20) Then press the Select [0] button to accept this Industry Application. NOTE: Only one (1) Industry Application may be selected at a time.

17

Page 26

The available Industry Applications to select from include; AIAG [ - - AIAG - - >] – Automotive applications BOOKLAND [ - Bookland - >] – Book applications CCBBA [ - CCBBA - >] – Blood Bank applications Comp Tia/CTIA/ABCD [ - - ABCD - - >] – Computer applications HIBCC [ - HIBCC - >] – Health Care applications LOGMARS [ - LOGMARS - >] – Government applications SCC[ - - - SCC - - - >] – Retail (SCS/ITF, EAN-128, UCC 128 Serial) SISAC [ - SISAC - >] – Serial Coding applications U.P.C. [ Coupon Code >] – Coupon Coding applications If additional user information must be input when an application is selected, the user will be prompted to do so after the Select button [0] has been pressed. Those applications need additional input follow: AIAG the user must indicate whether they are the “supplier” of the bar code or the “customer” receiving the bar code (the AIAG application specification adjusts acceptance criteria accordingly). [AIAG Custmr >] or [AIAG Supplr >] Pressing the Select [0] Button accepts the choice, the Scroll [<>] Button bypasses. SCC This application requires the entry of a magnification factor for the Interleaved 2/5 symbols to be tested (thereby setting appropriate tolerances!). The user steps through the choices (>75%, 74%, 70%, 66%, 62%, 58%, 54%, 50%) using the Scroll [<>] Button. Selection is made using the Select [0] Button. BOOKLAND As with the UPC/EAN/JAN codes mentioned earlier, the Bookland codes (which are based on those symbols) require input of a magnification factor. Again, the possible choices are .80, .85, .90, .95, 1.0, 1.2, 1.4, 1.6, 1.8 or 2.0 and are cycled through by repeatedly pressing the Scroll [<>] Button. Default is 1.0 or 100%.

18

Page 27

Model Selections: QC200 – Symbologies only QC210 – Retail Model. Symbologies plus retail/book industry applications. (SCC;BOOKLAND;SISAC) QC220 – Health Model. Symbologies plus health industry applications. (SCC;HIBSS;CCBBA) QC230 – Industrial/Government Model. Symbologies plus industrial/government.(LOGMARS;AIAG;ABDC/CTIA;SCC) QC250 – All Industry Applications plus Symbologies 4.3 “Tests” Options After Power up and pressing the Select [0] Button three times, you are brought to the “Test” Programming Sections: [ - Tests - >] Pressing the Scroll [<>]Button once at this point will access the area of the QC200’s programming where test procedures are determined. Use of the Select [0] and Scroll [<>] buttons here will allow you to select the unit's pass/fail level criteria (Traditional vs. ANSI), use of a higher level of statistical accuracy for measurement of each scan path (NormalAccur vs. ExtendAccur), type of Decodability calculation to use (Avg DMargin vs. Decodability) and whether, when ANSI is the pass/fail criteria, letter or number grading is used (Ltr. Grades vs. Num. Grades). An explanation of these possible selections follow. “Trad’l P/F” vs. “ANSI PrQual> A” / “ANSI PrQual> B”/ “ANSI PrQual? C”/”ANSI PrQual> D” The Quick Check 200 Series can apply Pass/Fail criteria based on either the “Traditional” bar code print tolerances and PCS measurements or the “Graded” methodology specified in the ANSI Standard “Bar Code Print Quality – Guideline” X3.182. Upon any measurement scan, the QC200 beeps either once to indicate a passing symbol or three (3) times to indicate failure of one or more tests. Choose here whether to apply Traditional Pass/Fail criteria -- PCS value and Print Tolerances – or the graded <A> through <F> criteria and scales from ANSI’s Print Quality Guideline.

19

Page 28

“NormalAccur” vs. “ExtendAccur” The Quick Check 200 Series is capable of scanning in a “Normal Accuracy” mode as well as in “Extended Accuracy”. In the “Extended Accuracy” Mode, ALL individual parameter measurements and results are averaged over eight (8) successive scans of a given scan path of the symbol under test, greatly reducing reading variability due to variations in scanning motion and minor scan path variations. This is not to be confused with ANSI’s recommended ten (10) scan symbol average, where ten (10) individual symbol scans have their final scan grade averaged. “Avg DMargin” vs. “Decodability” “Decodability” is an ANSI graded measure of how close a given scan comes to a reference decode failure due to variations in the bar and/or space widths. The Quick Check 200 Series has the ability to analyze a symbol using “Decodability Margin” (Avg DMargin in the QC200) as well as true “ANSI” Decodability (Decodability in the QC200). “Decodability Margin” is the character-averaged value of Decodability. Decodability is what percentage of the symbology’s safe decoding margin is left for the scanner after printing errors. Lower margin values and corresponding lower grades indicate an increased susceptibility to decoding failure due to scanning errors such as, for example, acceleration or bar or space size deviations. NOTE: Variations in scan speed affects ANSI Decodability. When hand scanning set this option to “Avg DMargin”. “Decodability” (ANSI Decodability) should only be used by those who have a very consistent and smooth scanning action or with automated scanning. The QC200 will “measure” your scanning and prompt you to “Scan Faster”, “Scan Slower” or “Scan Evenly” if it detects gross variations in your scan rates. “Ltr. Grades” vs. “Num. Grades” When the QC200 has been set to an ANSI grade for its test criteria, the user can have that ANSI grade reported as a letter or as a number ( 4.0=A, 3.0=B, 2.0=C, 1.0=D and 0.0=F) by selection either “Ltr. Grades” or “Num. Grades” here.

20

Page 29

4.4 “Config.” Options After Power up and pressing the Select [0] Button four times, you are brought to the “Config.” Programming Section: [ - Config. - >] Pressing the Scroll [<>] Button once at this point will access the area of the QC200’s programming where reporting configuration is determined. Use of the Select [0] and Scroll[<>] Buttons here will allow you to select the unit’s LCD orientation (Left Handed vs. Right Handed), raise or lower the beeper pitch or effect volume (Raise Pitch in single steps or Lower Pitch in single steps), select the HHP QC printer (HS Printer, VHS Printer or Std Printer) and finally save the settings in non-volatile RAM for future use. An explanation of these possible selections follows: “Left Handed” vs. “Right Handed” The QC200’s custom LCD display can have its text and read-outs oriented for either a left handed or right handed user. This automatic “flipping” of the LCD image makes the unit easy to use and read by all operators. Selection of either orientation is done here by pressing the Scroll [<>] Button. “Raise Pitch” Repeated pressing of the Scroll[<>] Button increases the pitch/volume of the QC200 beeper. “Lower Pitch” Repeated pressing of the Scroll[<>] Button increases the pitch/volume of the QC200 beeper. “Std Printer” vs. “HS Printer” vs. “VHS Printer” . The Quick Check 200 Series supports all three of Hand Held Products’ accessory printers. The QCP, QCHSP and QCSSP printer interface software is selected here by pressing the Scroll [<>] Button until the desired setting is shown on the LCD. To save these settings and the other previous selected options, the user again presses the Select [0] Button after leaving the desired accessory printer selection on the LCD. This brings the following message to the LCD:

21

Page 30

[SaveSetngs?>] Pressing the Select [0] Button will by-pass this (effectively answering “NO”), but pressing the Scroll [<>] Button will accept it, changing the LCD to : [**Confirm**>] This gives the user a last chance to change their minds and abort the changes. Again, pressing Select [0] will by-pass it, but pressing Scroll[<>] will accept it changing the LCD to: [ - Busy! - ] then to [Version yyyy] and finally to [QC2xx aa/lll] as the non-volatile memory is updated. The “yyyy” represents the base software’s “checksum”. This number can be used by Hand Held Products’ Service Department when identifying a QC200. (If the Select [0] Button is pressed after “SaveSetngs?>” or “**Confirm**>”, the LCD changes automatically to the “Version yyyy” message.

22