The text of a manual · part 2 of 9
Quick Check 200 Series User's Guide, pages 11 to 20
Pages 11 to 20 of 84
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC QC-200 and HHP QC-210
Page 11
2.0 Overview
The Quick Check 200 Series is one of the HHP family of Quick Check bar code quality assurance devices. The Quick Check 200 Series is fully portable and compatible with all major bar code symbologies. It is effectively two instruments in one, both an easyto-use Pass/Fail quick tester and a powerful measuring tool for detailed testing and analysis of those same symbols. Testing criteria within the Quick Check 200 Series is based on the American National Standard X3.182-1990 “Bar Code Print Quality Guideline.” The Quick Check family of bar code verifiers was designed specifically to fully implement this guideline guaranteeing symbol compliance to the standard. They provide a baseline in measurement accuracy against which all verifiers, new and old, should be judged. The QC200 series determines print quality, wide to narrow ratios, print contrast and reflectance parameters, decodes and verifies character format as called for by application specifications. The quality information from the Quick Check 200 Series is presented through an easy to read liquid crystal display (LCD), light emitting diodes (LEDs), audible tones and through its optional accessory printer. The knowledge gained using the Quick Check 200 Series measurement modes is invaluable in educating the user about the critical optical characteristics of bar code symbols. The Quick Check 200 Series can verify the quality of: • EAN/UPC family of symbols with or without addendum Code 39 with or without check character • Interleaved 2 of 5 with or without check character • Codabar/USS Codabar with or without check character • Code 128 with all modes and characters displayed • MSI Code • Code 16K • IATA 2 of 5 • Regular 2 of 5 3
Page 12
2.1 Unpacking When you first receive your Quick Check 200 Series unit, you should carefully unpack it. Before attempting to use the instrument, inspect the contents of the package for any shipping damage. If there is evidence of shipping damage, please keep ALL packing materials and contact the delivery carrier AS SOON AS POSSIBLE for claim procedure. Confirm that you have the following items: QC200 Series model number ordered. AC Charger User’s Guide Manual Pack with: Test Symbols Warranty Card Gauge Ruler “X” Dimension Ruler
Please fill out the Warranty Card immediately. Also make a note of the serial number of the unit and the date purchased. 2.2 Charging the Battery NOTE: The battery you received with your Quick Check 200 unit may be discharged. Prior to initial use, the batteries should be charged for at least six (6) hours. The Quick Check 200 unit is designed to operate only using the supplied NiCad rechargeable battery pack. It is not intended to be powered directly from an adapter or AC outlet. The Quick Check 200 Series verifier is designed to make maximum use of its battery power. As a result, the unit will operate for a minimum of one (1) hour on a properly charged battery pack.
4
Page 13
!!! WARNING!!! DO NOT CONNECT YOUR QUICK CHECK TO ITS CHARGER OR PRINTER UNLESS A BATTERY PACK IS INSTALLED. TO DO SO WILL DAMAGE THE UNIT AND VOID ITS WARRANTY!! ALL UNITS HAVE HAD A PACK INSTALLED AT THE TIME OF MANUFACTURE. USE ONLY A HHP SUPPLIED NICAD TYPE RECHARGEABLE BATTERY PACK. USE OF OTHER PACKS OR BATTERIES AND ATTEMPTS TO RECHARGE THESE BATTERIES COULD CAUSE THE BATTERIES TO EXPLODE, CAUSING DAMAGE TO THE UNIT AND POSSIBLE PERSONAL INJURY!! DAMAGE CAUSED BY ATTEMPTS TO RECHARGE OTHER THAN THE SPECIFIED HHP QC200 SERIES BATTERY PACK WILL VOID ANY AND ALL QUICK CHECK 200 SERIES WARRANTIES. To charge the batteries: 1. Plug the AC charger into the power jack on the end of the Quick Check unit. 2. Plug the AC charger power unit into an appropriate VAC wall outlet. 3. Charge the batteries for a minimum of six (6) hours. After allowing the proper battery charge time, your Quick Check will be ready for operation. If you experience any problems during this set up procedure, carefully review the above steps and try again. If you still have problems, contact your dealer or HHP for assistance. 2.3 Command Code “Quick Start” The Quick Check 200 Series is a complete, self-contained hand held bar code verifier. Though we recommend you become 5
Page 14
thoroughly familiar with the device and this manual before use, those familiar with bar code verification can easily set-up and use the QC200 within a matter of minutes (after it has been unpacked and initially charged) following the next steps: 1. Carefully unpack and inspect the unit. (See section titled UNPACKING for details) 2. Plug the QCAC charger into the QC200 and an AC wall outlet and charge the unit for a minimum of six hours. (See sectional titled CHARGING THE BATTERY for details) 3. After charging, turn the unit on by pressing and releasing the POWER button. You should hear four beeps indicating the unit is ready. 4. Next, select one of the following pre-printed “Quick Start” Command Codes appropriate for your use of the QC200, carefully place the tip of the QC200 on the Command Code of choice and scan the code. 5. The unit will respond with four beeps and return to the start up, ready to scan state. 6. You have now totally programmed your QC200 and are ready to scan your sample codes. After each scan, the custom LCD display will show decode, symbology type, PCS or ANSI grade, bar growth/shrinkage indication and any parameter areas where errors exist. If the code has passed all tests, one beep will be heard and the green LED will flash. If errors have been found, three beeps will be heard, the red LED will flash and one or more of the parameter areas will be lit on the LCD (DIM, REF and /or FMT) to show in what test criteria area(s) the fault exists. Detailed information on proper scanning techniques and unit use can be found throughout this manual. If you have any problems during your “Quick Start,” please refer to the rest of this manual or call Hand Held Products’ Application Support. NOTE: Display Orientation (Right Handed vs. Left Handed) and Printer Interface selection ARE NOT set using the Command Code. Factory default settings for these are “Right Handed” and “QCHSP”.
6
Page 15
3.0 Detailed Operation The Quick Check 200 Series is a complete, self-contained hand held bar code verifier. The top panel features include a “POWER” button a “SELECT” button [0], a “SCROLL” [<>] button, a red and a green colored LED and a custom, multifunction, liquid crystal display (LCD). On the bottom of the instrument is the Serial Number label as well as two of the three case screws that must be removed for access to the internal battery. (WARNING: DO NOT attempt to replace the battery pack without first contacting Hand Held Products’ Service Department!) A port on the end allows connection to a recharger or optional printer. The following figures show the unit’s layout.
Figure A
7
Page 16
Quick Check 200 Control Buttons
3.1 Using the QC200 Before you turn the unit on and select a mode of operation, you should review the following to learn how to properly scan a bar code with it.
8
Page 17
To scan a bar code: 1. Hold the QC200 as you would a pen or pencil. The raised “finger grip ridges” on each side of the case near the optics/scanning tip are guides for finger placement. 2. Press the optics tip lightly against the surface to be scanned in the clear area (quiet zone) on either side of the bar code symbol. To maintain a proper scanning angle, be sure both the optics tip and the “reflectance guide” are flat on the surface to be scanned. 3. At about the same speed with which you would quickly underline one of the sentences in this text, and without interruption, move the QC200 evenly across the center (or approximate center) of the bar code. 4. Listen for a long beep tone quickly followed by a short beep tone signifying a good read. Note that a long beep followed by three short beeps indicates an error condition exists in the symbol scanned. NOTE: Practice your scanning technique until you can successfully scan each of the supplied test symbols on each attempt. Some of the supplied test symbols have “intentional errors” in them to show the user how error conditions are reported. 3.2 Power ON/OFF The Quick Check 200 Series is turned on by pressing the POWER button, to which it responds by emitting four quick beeps and first displays: [QC2xx aa/lll] where “xx” identifies the model number, “aa” is the aperture size designation in “mils” (one thousandths of an inch) and “lll” is the spectral response or wavelength of illumination in nanometers. If there are stored print records (and the unit is connected to a Quick Check AC Charger or Printer interface cable), the display then changes to: [BUF xx% Ful>] or it may read “LOW BATTERY!” or “RECALIBRATE!” if charging or reflectance calibration is needed. 9
Page 18
The Quick Check 200 Series shuts itself off after about a minute of inactivity. Alternately, the operator can shut the instrument off by pressing the button for about two seconds, until it beeps and clears the display. 3.3 Reflectance Scale Calibration The first time you use the unit or charge the battery pack and periodically during normal operation, the Quick Check 200 Series reflectance scale should be calibrated. Remove the QC200 Reflection Calibration Page (QCRFPG) from the manual and, with the unit at the proper scanning angle (so it rests on its “reflectance guide”), CAREFULLY scan the reference target symbol 10 times. Note that your first scan will yield a “triple” beep (one long, two short) as well as your tenth scan. NOTE: TO INSURE MAXIMUM REFLECTANCE-SCALE ACCURACY FOR THE HIGHEST ACCURACY IN DATA COLLECTION, YOUR QUICK CHECK PERFORMS A CONSISTENCY TEST WHILE THE TEN CALIBRATION SCANS ARE MADE. IF, DURING THOSE SCANS, IT DETECTS REFLECTANCE READINGS SIGNIFICANTLY DIFFERENT FROM THE PREVIOUS ONES RECORDED, IT WILL AGAIN “BEEP” THREE (3) TIMES AND THE LCD WILL PROMPT YOU TO AGAIN BEGIN THE REFLECTANCE CALIBRATION PROCEDURE. IF DURING THE MEASUREMENT OF A SAMPLE SYMBOL AN “XX” or “- -“ IS DISPLAYED OR PRINTED A REFLECTANCE VALUE, AND OUT OF RANGE READING HAS BEEN MADE. THE UNIT SHOULD BE RECALIBRATED AND THE SAMPLE SHOULD BE RESCANNED.
3.4 Initial Power Up Default Settings The Quick Check 200 Series powers up in whatever operating mode it was last left in. To facilitate “getting started”, we have programmed the QC200 so that it will default, the first time it is powered up and calibrated, to the settings listed. The many possible variations available to the QC200 user will be outlined in later sections of this guide.
10
Page 19
All codes Active (Auto-discrimination) Those Codes are: Code 39 Interleaved 2 of 5 EAN/UPC 100% Magnification Codabar Code 128 MSI 16K Other Configuration Settings: “NormalAccur” – Normal Accuracy “Trad’l P/F” – Traditional Tolerance Testing “Avg DMargin” – HHP Averaged Decodability Margin “Ltr. Grades” – If ANSI is invoked, Letter Grades used “Right Handed” – LCD Right Hand Orientation “HS Printer” – Printer Interface set for HHP QCHSP An explanation of each of the above default settings can be found in the CONFIGURATION/PROGRAMMING section.
11
Page 20
12