Page 67
6 Secondary Interface By switching interface cables, the IT3800/3900 scanner can communicate with a portable data terminal (secondary interface), in addition to the host terminal (primary interface). Note: Secondary interfaces do not apply to the IT3800LX-15. The secondary interface can be programmed at any time.
Secondary Code 39 Wand Emulation In Wand Emulation mode, the scanner decodes the bar code then sends data in the same format as a wand scanner. The Code 39 Format converts all symbologies to Code 39. The Same Code Format transmits UPC, EAN, Code 128 and Interleaved 2 of 5 without any changes, but converts all other symbologies to Code 39. These codes set the transmission rate to 25 inches per second and the output polarity to black, high. Default = Code 39 Format.
* Wand Emulation Code 39 Format Wand Emulation Same Code Format Note for the 3800PDF model: When the 3800PDF interface is set to wand emulation, all PDF417 bar code data is transmitted as Code 128. Data from other symbologies follow the rules described above.
Secondary RS-232 Connection All communication parameters between the scanner and terminal must match for correct data transfer through the serial port using RS-232 protocol. RS-232 programmable selections are used by both the primary and secondary interfaces. Changing an RS-232 parameter (e.g., baud rate or parity), while in primary or secondary mode will affect both interfaces.
RS-232 Interface
6-1
Page 68
Secondary Non Decoded Output Laser Emulation Use this selection when connecting to a secondary terminal with integral decoding. This also sets the transmission rate to 36 scans per second and the polarity to white high.
Non Decoded Output
Non Decoded Output Laser Emulation Transmission Rate The Transmission Rate is limited by the terminal’s ability to receive data without dropping characters. Default = 36 scans/second.
* 36
100
Non Decoded Output Laser Emulation Polarity The Polarity can be sent as standard with white bars high, or reversed with black bars high. Default = White High.
* White High
Black High
6-2
Page 69
Non Decoded Laser Emulation Idle The idle describes the state of the scanner when no data is being transmitted. When in Non Decoded mode, you must set the scanner’s idle state to match the idle state for the device to which the scanner is connected. Default = High.
Low
* High
Disabling the Secondary Interface You can temporarily disable the secondary interface, but still retain the secondary interface settings in the scanner’s memory by scanning the Disable bar code below. To re-enable the secondary interface, scan the Enable bar code. Default =Disable.
* Disable
Enable
Secondary Trigger Mode Manual Trigger: You must press the scanner trigger to scan. When not scanning, idle power is maintained. Default = Manual Trigger.
* Manual Trigger
6-3
Page 70
Automatic Trigger: The scanner scans continuously at full power.
Automatic Trigger
Manual Trigger, Low Power: The scanner “sleeps,” using only 30 milliamps, until the trigger is pulled. When the trigger is pulled, the scanner wakes up and operates at normal power until there is no triggering for the time set with the Low Power Time Out bar code. Then, the scanner goes to “sleep” again. Low Power Time Out: Scan the Low Power Time Out bar code to change the time out duration. Then scan the time out duration (from 0-300 seconds) from the inside back cover and Save. Default = 2 minutes. Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Low Power Time Out bar code, scan the correct digits, and Save again.
Manual Trigger, Low Power
Low Power Time Out
Note: The Secondary Manual Trigger, Lower Power option is not available on the 3800LR-11 in Secondary Non-Decoded Out Laser Emulation Mode.