Page 71

7 Symbologies Introduction Use this section to program the scanner for Industrial, Retail, and PDF417 Symbology selections. This programming section contains the following menu selections: All Symbologies

IATA Code 2 of 5

China Post Code

Interleaved 2 of 5

Codabar

Matrix 2 of 5

Code 2 of 5

MicroPDF417

Code 11

MSI

Code 39

PDF417

Code 39 PARAF

Plessey

Code 93

RSS-14

Code 128

Telepen

EAN/JAN

UPC

EAN•UCC Composite

All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On code.

All Symbologies On

All Symbologies Off

7-1

Page 72

Codabar <Default All Codabar Settings>

Codabar

* On

Off

Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit.

Transmit

* Don’t Transmit

7-2

Page 73

Codabar (continued) Check Character Codabar check characters are created using different “modulos.” You can program the scanner to read only Codabar bar codes with Modulo 16 check characters. Default = No Check Character.

No Check Character indicates that the scanner reads and transmits bar code data with or without a check character. When Check Character is set to Validate and Transmit, the scanner will only read Codabar bar codes printed with a check character, and will transmit this character at the end of the scanned data. When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data.

* No Check Character

Validate Modulo 16, but Don’t Transmit Validate Modulo 16 and Transmit

7-3

Page 74

Concatenation Codabar supports symbol concatenation. When you Enable concatenation, the scanner looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two messages are concatenated into one with the “D” characters omitted. Default = On. Character Start

Stop

Start

Stop

Codabar A12D

D34A

Select Require to prevent the scanner from decoding a lone Codabar symbol.

* On

Off

Require

Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the 2-digit value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 2-60.

7-4

Page 75

Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.

Minimum (Default =4)

Maximum (Default =60)

7-5

Page 76

Code 39 < Default All Code 39 Settings >

Code 39

* On

Off

Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit.

Transmit

* Don’t Transmit

7-6

Page 77

Code 39, continued Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character. When Check Character is set to Validate, but Don’t Transmit, the unit will only read Code 39 bar codes printed with a check character, but will not transmit the check character with the scanned data. When Check Character is set to Validate and Transmit, the scanner will only read Code 39 bar codes printed with a check character, and will transmit this character at the end of the scanned data. Default = No Check Character.

* No Check Character

Validate, but Don’t Transmit

Validate and Transmit

Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the 2-digit value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 0-48.

7-7

Page 78

Code 39, continued Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.

Minimum (Default =0)

Maximum (Default =48)

Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer. When this function is enabled, the scanner stores those Code 39 bar codes that start with a space (excluding the start and stop symbols), and does not immediately transmit the data. The scanner stores the data in the order in which the bar codes are read, deleting the first space from each. The scanner transmits the appended data when it reads a Code 39 bar code that starts with a character other than a space. Default = Off.

On

* Off

Base 32 Base 32 is a form of the Code 39 symbology used by Italian pharmacies. This is also known as PARAF.

On

* Off

7-8

Page 79

Code 39, continued Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = On. NUL %U

DLE $P

SP

SPACE 0

0

@

%V

P

P

‘

W p

+P

SOH $A

DC1 $Q

!

/A

1

1

A

A

Q

Q a

+A q

+Q

STX $B

DC2 $R

“

/B

2

2

B

B

R

R b

+B r

+R

ETX $C

DC3 $S

#

/C

3

3

C

C

S

S c

+C s

+S

EOT $D

DC4 $T

$

/D

4

4

D

D

T

T d

+D t

+T

ENQ $E

NAK $U

%

/E

5

5

E

E

U

U e

+E u

+U

ACK $F

SYN $V

&

/F

6

6

F

F

V

V f

+F v

+V

BEL $G

ETB $W

‘

/G

7

7

G

G

W

W g

+G w

+W

BS

$H

CAN $X

(

/H

8

8

H

H

X

X h

+H x

+X

HT

$I

EM

$Y

)

/I

9

9

I

I

Y

Y i

+I y

+Y

LF

$J

SUB $Z

*

/J

:

/Z

J

J

Z

Z j

+J z

+Z

VT

$K

ESC %A

+

/K

;

%F

K

K

[

%K k

+K

{

%P

FF

$L

FS

%B

,

/L

<

%G L

L

\

%L l

+L

|

%Q

CR

$M

GS

%C

-

-

=

%H

M

M

]

%M m

+M

}

%R

SO

$N

RS

%D

.

.

>

%I

N

N

^

%N n

+N

~

%S

SI

$O

US

%E

/

/O

?

%J

O

O

_

%0 o

+O

DEL %T

Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9.

* Full ASCII On

Full ASCII Off

7-9

Page 80

Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings >

Interleaved 2 of 5

* On

Off

Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit will only read Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data. When Check Digit is set to Validate and Transmit, the scanner will only read Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit.

* No Check Digit

Validate, but Don’t Transmit

Validate and Transmit

7 - 10