Page 139
13 Serial Programming Commands The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will program the IT3800/3900. For complete descriptions and examples of each serial programming command, refer to the corresponding programming bar code in this manual. The device must be set to an RS-232 interface (see page 1-8). The following commands can be sent via a PC com port using terminal emulation software.
Conventions The following conventions are used for menu and query command descriptions: parameter
A label representing the actual value you should send as part of a command.
[option]
An optional part of a command.
{Data}
Alternatives in a command.
bold
Names of menus, menu commands, buttons, dialog boxes, and windows that appear on the screen.
Menu Command Syntax Menu commands have the following syntax (spaces have been used for clarity only): Prefix Tag SubTag {Data} [, SubTag {Data}] [; Tag SubTag {Data}] […] Storage Prefix
Three ASCII characters: SYN M CR (ASCII 22,77,13).
Tag
A 3 character case-insensitive field that identifies the desired menu command group. For example, all RS-232 configuration settings are identified with a Tag of 232.
SubTag
A 3 character case-insensitive field that identifies the desired menu command within the tag group. For example, the SubTag for the RS-232 baud rate is BDR.
Data
The new value for a menu setting, identified by the Tag and SubTag.
13 - 1
Page 140
Storage
A single character that specifies the storage table to which the command is applied. An exclamation point (!) performs the command’s operation on the device’s volatile menu configuration table. A period (.) performs the command’s operation on the device’s non-volatile menu configuration table. Use the non-volatile table only for semi-permanent changes you want saved through a power cycle. (The non-volatile table allows only a limited number of writes.)
Query Commands Several special characters can be used to query the device about its settings.
^ ? *
What is the default value for the setting(s). What is the device’s current value for the setting(s). What is the range of possible values for the setting(s). (The device’s response uses a dash (-) to indicate a continuous range of values. A pipe (|) separates items in a list of non-continuous values.)
Tag Field Usage When a query is used in place of a Tag field, the query applies to the entire set of commands available for the particular storage table indicated by the Storage field of the command. In this case, the SubTag and Data fields should not be used because they are ignored by the device. SubTag Field Usage When a query is used in place of a SubTag field, the query applies only to the subset of commands available that match the Tag field. In this case, the Data field should not be used because it is ignored by the device. Data Field Usage When a query is used in place of the Data field, the query applies only to the specific command identified by the Tag and SubTag fields.
Concatenation of Multiple Commands Multiple commands can be issued within one Prefix/Storage sequence. Only the Tag, SubTag, and Data fields must be repeated for each command in the sequence. If additional commands are to be applied to the same Tag, then the new command sequence is separated with a comma (,) and only the SubTag and Data fields of the additional command are issued. If the additional command requires a different Tag field, the command is separated from previous commands by a semicolon (;).
13 - 2
Page 141
Responses The device responds to serial commands with one of three responses: ACK Indicates a good command which has been processed. ENQ Indicates an invalid Tag or SubTag command. NAK Indicates the command was good, but the Data field entry was out of the allowable range for this Tag and SubTag combination, e.g., an entry for a minimum message length of 100 when the field will only accept 2 characters. When responding, the device echoes back the command sequence with the status character inserted directly before each of the punctuation marks (the period, exclamation point, comma, or semicolon) in the command.
Examples of Query Commands In the following examples, a bracketed notation [ ] depicts a non-displayable response. Example #1:What is the range of possible values for Codabar Coding Enable? Enter: cbrena*. Response: CBRENA0-1[ACK] This response indicates that Codabar Coding Enable (CBRENA) has a range of values from 0 to 1 (off and on). Example #2: What is the default value for Codabar Coding Enable? Enter: cbrena^. Response: CBRENA1[ACK] This response indicates that the default setting for Codabar Coding Enable (CBRENA) is 1, or on. Example #3: What is the device’s current setting for Codabar Coding Enable? Enter: cbrena?. Response: CBRENA1[ACK] This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on.
13 - 3
Page 142
Example #4: What are the device’s settings for all Codabar selections? Enter: cbr?. Response: CBRENA1[ACK], SSX0[ACK], CK20[ACK], CCT1[ACK], MIN2[ACK], MAX60[ACK], DFT[ACK]. This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on; the Start/Stop Character (SSX) is set to 0, or Don’t Transmit; the Check Character (CK2) is set to 0, or Not Required; concatenation (CCT) is set to 1, or Enabled; the Minimum Message Length (MIN) is 2 characters; the Maximum Message Length (MAX) is 60 characters; and the Default setting (DFT) has no value.
Trigger Commands You can activate and deactivate the scanner with serial trigger commands. First, the scanner must be put in Manual/Serial Trigger Mode either by scanning the Manual/Serial Trigger Mode bar code (page 3-4), or by sending the Manual/ Serial Menu Command (page 13-8). Once the scanner is in serial trigger mode, the trigger is activated and deactivated by sending the following commands: Activate:
SYN T CR
Deactivate:
SYN U CR
The scanner scans until a bar code has been read, until the deactivate command is sent, or until the serial time out has been reached (see "Serial Trigger Time Out" on page 3-5 for a description, and the serial command on page 138).
13 - 4
Page 143
Menu Commands Selection Factory Default Settings
Setting
Serial Command
* Indicates default setting
# Indicates a numeric entry
Default
DEFALT
Terminal Interfaces Terminal ID
TERMID###
Program Keyboard Country
KBDCTY##
Keyboard Style
Keyboard Modifiers
Serial Port Connection
Baud Rate
*Regular
KBDSTY0
Caps Lock
KBDSTY1
Shift Lock
KBDSTY2
Emulate External Keyboard
KBDSTY5
Automatic Caps Lock
KBDSTY6
*Control + ASCII Off
KBDCAS0
Control + ASCII On
KBDCAS1
*Turbo Mode Off
KBDTMD0
Turbo Mode On
KBDTMD1
*Numeric Keypad Off
KBDNPS0
Numeric Keypad On
KBDNPS1
*Auto Direct Conn. Off
KBDADC0
Auto Direct Conn. On
KBDADC1
RS-232
PAP232
300 BPS
232BAD0
600 BPS
232BAD1
1200 BPS
232BAD2
2400 BPS
232BAD3
4800 BPS
232BAD4
*9600 BPS
232BAD5
19200 BPS
232BAD6
38400 BPS
232BAD7
13 - 5
Page 144
Selection
Word Length: Data Bits, Stop Bits, and Parity
RS-232 Handshaking
Wand Emulation Connection
Wand Emulation Transmission Rate
Wand Emulation Polarity
Wand Emulation Idle
13 - 6
Setting
Serial Command
* Indicates default setting
# Indicates a numeric entry
*7 Data, 1 Stop, Parity Even
232WRD3
7 Data, 1 Stop, Parity None
232WRD0
7 Data, 1 Stop, Parity Odd
232WRD6
7 Data, 1 Stop, Parity Mark
232WRD12
7 Data, 1 Stop, Parity Space
232WRD9
7 Data, 2 Stop, Parity Even
232WRD4
7 Data, 2 Stop, Parity None
232WRD1
7 Data, 2 Stop, Parity Odd
232WRD7
7 Data, 2 Stop, Parity Mark
232WRD13
7 Data, 2 Stop, Parity Space
232WRD10
8 Data, 1 Stop, Parity Even
232WRD5
8 Data, 1 Stop, Parity None
232WRD2
8 Data, 1 Stop, Parity Odd
232WRD8
8 Data, 1 Stop, Parity Mark
232WRD14
8 Data, 1 Stop, Parity Space
232WRD11
*RTS/CTS Off
232CTS0
RTS/CTS On
232CTS1
*XON/XOFF Off
232XON0
XON/XOFF On
232XON1
*ACK/NAK Off
232ACK0
ACK/NAK On
232ACK1
Same Code Format
WNDPAT0
*Code 39 Format
WNDPAT1
10
WNDSPD0
*25
WNDSPD1
40
WNDSPD2
80
WNDSPD3
120
WNDSPD4
150
WNDSPD5
200
WNDSPD6
*Black High
WNDPOL0
White High
WNDPOL1
Idle Low
WNDIDL0
*Idle High
WNDIDL1
Page 145
Selection
Setting
Serial Command
* Indicates default setting
# Indicates a numeric entry
PDF417 Wand Emulation Data Block Size
Delay Between Blocks
Overall Checksum
20
WNDBLK0
40
WNDBLK1
*60
WNDBLK2
80
WNDBLK3
5ms
WNDDLY0
*50ms
WNDDLY1
150ms
WNDDLY2
500ms
WNDDLY3
*Off
WNDCHK0
On
WNDCHK1
Output Selections Scan Rate
Beeper Volume
Beeper Tone
Scan Voting
Reduce Quiet Zone
Reread Delay
Good Read Delay
67 s/s
SCNPFM0
135 s/s
SCNPFM1
*270 s/s
SCNPFM2
Off
BEPLVL0
Low
BEPLVL1
Medium
BEPLVL2
*High
BEPLVL3
*Normal Beep
BEPBIP0
Short Beep
BEPBIP1
*Voting Normal
DECVLV0
Voting High
DECVLV1
*Don’t Reduce Quiet Zone
DECRQZ0
Reduce Quiet Zone
DECRQZ1
*Short
RRDDLY0
Medium
RRDDLY1
Long
RRDDLY2
Extra Long
RRDDLY3
*No Delay
GRDDLY0
Short Delay
GRDDLY1
Medium Delay
GRDDLY2
Long Delay
GRDDLY3
13 - 7
Page 146
Selection
Trigger Mode
Trigger Time Out
Setting
Serial Command
* Indicates default setting
# Indicates a numeric entry
Manual/Serial Trigger
TRGMOD0
Automatic Trigger
TRGMOD1
Manual Trigger, Low Power
TRGMOD2
Presentation Mode
TRGMOD3
Serial Trigger Time Out
TRGSTO####
Low Power Time Out
TRGLPT###
Prefix/Suffix Selections Add CR Suffix to All Symbologies
Prefix
Suffix
Function Code Transmit
VSUFCR Add Prefix
PREBK2
Clear One Prefix
PRECL2
Clear All Prefixes
PRECA2
Add Suffix
SUFBK2
Clear One Suffix
SUFCL2
Clear All Suffixes
SUFCA2
*Enable
RMVFNC0
Disable
Intercharacter Delay User Specified Intercharacter Delay
RMVFNC1 DLYCHR##
Delay Length Character to Trigger Delay
DLYCRX## DLY_XX##
Interfunction Delay
DLYFNC##
Intermessage Delay
DLYMSG##
Data Formatter Selections Data Format Editor
Data Formatter
Alternate Data Formats
13 - 8
*Default Data Format (None)
DFMDF3
Enter Format
DFMBK3
Clear One Format
DFMCL3
Clear All Formats
DFMCA3
Off
DFM_EN0
*On, but Not Required
DFM_EN1
On, Required
DFM_EN2
1
VSAF_1
2
VSAF_2
3
VSAF_3