Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 18 of 22

IMAGETEAM 3800/3900 Hand Held Linear Imager User's Guide: Serial Programming Commands, pages 139 to 146

Pages 139 to 146 of 180, from IMAGETEAM 3800/3900 Hand Held Linear Imager User's Guide

The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP IT3800 and HHP IT3900

Page 139

13 Serial Programming Commands The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will program the IT3800/3900. For complete descriptions and examples of each serial programming command, refer to the corresponding programming bar code in this manual. The device must be set to an RS-232 interface (see page 1-8). The following commands can be sent via a PC com port using terminal emulation software.

Conventions The following conventions are used for menu and query command descriptions: parameter

A label representing the actual value you should send as part of a command.

[option]

An optional part of a command.

{Data}

Alternatives in a command.

bold

Names of menus, menu commands, buttons, dialog boxes, and windows that appear on the screen.

Menu Command Syntax Menu commands have the following syntax (spaces have been used for clarity only): Prefix Tag SubTag {Data} [, SubTag {Data}] [; Tag SubTag {Data}] […] Storage Prefix

Three ASCII characters: SYN M CR (ASCII 22,77,13).

Tag

A 3 character case-insensitive field that identifies the desired menu command group. For example, all RS-232 configuration settings are identified with a Tag of 232.

SubTag

A 3 character case-insensitive field that identifies the desired menu command within the tag group. For example, the SubTag for the RS-232 baud rate is BDR.

Data

The new value for a menu setting, identified by the Tag and SubTag.

13 - 1

Page 140

Storage

A single character that specifies the storage table to which the command is applied. An exclamation point (!) performs the command’s operation on the device’s volatile menu configuration table. A period (.) performs the command’s operation on the device’s non-volatile menu configuration table. Use the non-volatile table only for semi-permanent changes you want saved through a power cycle. (The non-volatile table allows only a limited number of writes.)

Query Commands Several special characters can be used to query the device about its settings.

^ ? *

What is the default value for the setting(s). What is the device’s current value for the setting(s). What is the range of possible values for the setting(s). (The device’s response uses a dash (-) to indicate a continuous range of values. A pipe (|) separates items in a list of non-continuous values.)

Tag Field Usage When a query is used in place of a Tag field, the query applies to the entire set of commands available for the particular storage table indicated by the Storage field of the command. In this case, the SubTag and Data fields should not be used because they are ignored by the device. SubTag Field Usage When a query is used in place of a SubTag field, the query applies only to the subset of commands available that match the Tag field. In this case, the Data field should not be used because it is ignored by the device. Data Field Usage When a query is used in place of the Data field, the query applies only to the specific command identified by the Tag and SubTag fields.

Concatenation of Multiple Commands Multiple commands can be issued within one Prefix/Storage sequence. Only the Tag, SubTag, and Data fields must be repeated for each command in the sequence. If additional commands are to be applied to the same Tag, then the new command sequence is separated with a comma (,) and only the SubTag and Data fields of the additional command are issued. If the additional command requires a different Tag field, the command is separated from previous commands by a semicolon (;).

13 - 2

Page 141

Responses The device responds to serial commands with one of three responses: ACK Indicates a good command which has been processed. ENQ Indicates an invalid Tag or SubTag command. NAK Indicates the command was good, but the Data field entry was out of the allowable range for this Tag and SubTag combination, e.g., an entry for a minimum message length of 100 when the field will only accept 2 characters. When responding, the device echoes back the command sequence with the status character inserted directly before each of the punctuation marks (the period, exclamation point, comma, or semicolon) in the command.

Examples of Query Commands In the following examples, a bracketed notation [ ] depicts a non-displayable response. Example #1:What is the range of possible values for Codabar Coding Enable? Enter: cbrena*. Response: CBRENA0-1[ACK] This response indicates that Codabar Coding Enable (CBRENA) has a range of values from 0 to 1 (off and on). Example #2: What is the default value for Codabar Coding Enable? Enter: cbrena^. Response: CBRENA1[ACK] This response indicates that the default setting for Codabar Coding Enable (CBRENA) is 1, or on. Example #3: What is the device’s current setting for Codabar Coding Enable? Enter: cbrena?. Response: CBRENA1[ACK] This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on.

13 - 3

Page 142

Example #4: What are the device’s settings for all Codabar selections? Enter: cbr?. Response: CBRENA1[ACK], SSX0[ACK], CK20[ACK], CCT1[ACK], MIN2[ACK], MAX60[ACK], DFT[ACK]. This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on; the Start/Stop Character (SSX) is set to 0, or Don’t Transmit; the Check Character (CK2) is set to 0, or Not Required; concatenation (CCT) is set to 1, or Enabled; the Minimum Message Length (MIN) is 2 characters; the Maximum Message Length (MAX) is 60 characters; and the Default setting (DFT) has no value.

Trigger Commands You can activate and deactivate the scanner with serial trigger commands. First, the scanner must be put in Manual/Serial Trigger Mode either by scanning the Manual/Serial Trigger Mode bar code (page 3-4), or by sending the Manual/ Serial Menu Command (page 13-8). Once the scanner is in serial trigger mode, the trigger is activated and deactivated by sending the following commands: Activate:

SYN T CR

Deactivate:

SYN U CR

The scanner scans until a bar code has been read, until the deactivate command is sent, or until the serial time out has been reached (see "Serial Trigger Time Out" on page 3-5 for a description, and the serial command on page 138).

13 - 4

Page 143

Menu Commands Selection Factory Default Settings

Setting

Serial Command

* Indicates default setting

# Indicates a numeric entry

Default

DEFALT

Terminal Interfaces Terminal ID

TERMID###

Program Keyboard Country

KBDCTY##

Keyboard Style

Keyboard Modifiers

Serial Port Connection

Baud Rate

*Regular

KBDSTY0

Caps Lock

KBDSTY1

Shift Lock

KBDSTY2

Emulate External Keyboard

KBDSTY5

Automatic Caps Lock

KBDSTY6

*Control + ASCII Off

KBDCAS0

Control + ASCII On

KBDCAS1

*Turbo Mode Off

KBDTMD0

Turbo Mode On

KBDTMD1

*Numeric Keypad Off

KBDNPS0

Numeric Keypad On

KBDNPS1

*Auto Direct Conn. Off

KBDADC0

Auto Direct Conn. On

KBDADC1

RS-232

PAP232

300 BPS

232BAD0

600 BPS

232BAD1

1200 BPS

232BAD2

2400 BPS

232BAD3

4800 BPS

232BAD4

*9600 BPS

232BAD5

19200 BPS

232BAD6

38400 BPS

232BAD7

13 - 5

Page 144

Selection

Word Length: Data Bits, Stop Bits, and Parity

RS-232 Handshaking

Wand Emulation Connection

Wand Emulation Transmission Rate

Wand Emulation Polarity

Wand Emulation Idle

13 - 6

Setting

Serial Command

* Indicates default setting

# Indicates a numeric entry

*7 Data, 1 Stop, Parity Even

232WRD3

7 Data, 1 Stop, Parity None

232WRD0

7 Data, 1 Stop, Parity Odd

232WRD6

7 Data, 1 Stop, Parity Mark

232WRD12

7 Data, 1 Stop, Parity Space

232WRD9

7 Data, 2 Stop, Parity Even

232WRD4

7 Data, 2 Stop, Parity None

232WRD1

7 Data, 2 Stop, Parity Odd

232WRD7

7 Data, 2 Stop, Parity Mark

232WRD13

7 Data, 2 Stop, Parity Space

232WRD10

8 Data, 1 Stop, Parity Even

232WRD5

8 Data, 1 Stop, Parity None

232WRD2

8 Data, 1 Stop, Parity Odd

232WRD8

8 Data, 1 Stop, Parity Mark

232WRD14

8 Data, 1 Stop, Parity Space

232WRD11

*RTS/CTS Off

232CTS0

RTS/CTS On

232CTS1

*XON/XOFF Off

232XON0

XON/XOFF On

232XON1

*ACK/NAK Off

232ACK0

ACK/NAK On

232ACK1

Same Code Format

WNDPAT0

*Code 39 Format

WNDPAT1

10

WNDSPD0

*25

WNDSPD1

40

WNDSPD2

80

WNDSPD3

120

WNDSPD4

150

WNDSPD5

200

WNDSPD6

*Black High

WNDPOL0

White High

WNDPOL1

Idle Low

WNDIDL0

*Idle High

WNDIDL1

Page 145

Selection

Setting

Serial Command

* Indicates default setting

# Indicates a numeric entry

PDF417 Wand Emulation Data Block Size

Delay Between Blocks

Overall Checksum

20

WNDBLK0

40

WNDBLK1

*60

WNDBLK2

80

WNDBLK3

5ms

WNDDLY0

*50ms

WNDDLY1

150ms

WNDDLY2

500ms

WNDDLY3

*Off

WNDCHK0

On

WNDCHK1

Output Selections Scan Rate

Beeper Volume

Beeper Tone

Scan Voting

Reduce Quiet Zone

Reread Delay

Good Read Delay

67 s/s

SCNPFM0

135 s/s

SCNPFM1

*270 s/s

SCNPFM2

Off

BEPLVL0

Low

BEPLVL1

Medium

BEPLVL2

*High

BEPLVL3

*Normal Beep

BEPBIP0

Short Beep

BEPBIP1

*Voting Normal

DECVLV0

Voting High

DECVLV1

*Don’t Reduce Quiet Zone

DECRQZ0

Reduce Quiet Zone

DECRQZ1

*Short

RRDDLY0

Medium

RRDDLY1

Long

RRDDLY2

Extra Long

RRDDLY3

*No Delay

GRDDLY0

Short Delay

GRDDLY1

Medium Delay

GRDDLY2

Long Delay

GRDDLY3

13 - 7

Page 146

Selection

Trigger Mode

Trigger Time Out

Setting

Serial Command

* Indicates default setting

# Indicates a numeric entry

Manual/Serial Trigger

TRGMOD0

Automatic Trigger

TRGMOD1

Manual Trigger, Low Power

TRGMOD2

Presentation Mode

TRGMOD3

Serial Trigger Time Out

TRGSTO####

Low Power Time Out

TRGLPT###

Prefix/Suffix Selections Add CR Suffix to All Symbologies

Prefix

Suffix

Function Code Transmit

VSUFCR Add Prefix

PREBK2

Clear One Prefix

PRECL2

Clear All Prefixes

PRECA2

Add Suffix

SUFBK2

Clear One Suffix

SUFCL2

Clear All Suffixes

SUFCA2

*Enable

RMVFNC0

Disable

Intercharacter Delay User Specified Intercharacter Delay

RMVFNC1 DLYCHR##

Delay Length Character to Trigger Delay

DLYCRX## DLY_XX##

Interfunction Delay

DLYFNC##

Intermessage Delay

DLYMSG##

Data Formatter Selections Data Format Editor

Data Formatter

Alternate Data Formats

13 - 8

*Default Data Format (None)

DFMDF3

Enter Format

DFMBK3

Clear One Format

DFMCL3

Clear All Formats

DFMCA3

Off

DFM_EN0

*On, but Not Required

DFM_EN1

On, Required

DFM_EN2

1

VSAF_1

2

VSAF_2

3

VSAF_3