Page 129

11 Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Chart on page 4-5 for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D. prefix for all symbologies. This is a temporary setting that will be removed when the unit is power cycled.

Add Code I.D. Prefix to All Symbologies

Show Software Revision Scan the bar code below to output the current software revision.

Show Revision

Show Data Format Scan the bar code below to show current data format settings.

Data Format Settings

11 - 1

Page 130

Specular Effect Reduction When the On code is scanned, the first pass read rate and voting threshold are increased. Default = Off.

On

* Off Note: If you want to further limit specular effects, reduce the scan speed using "Scan Rate" on page 3-1.

11 - 2

Page 131

12 Default Charts Resetting the Factory Settings If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want the factory settings restored, scan the Factory Default Settings bar code below.

Factory Default Settings The following chart lists the factory default settings (indicated by an asterisk (*) on the programming pages). Parameter

Default Setting

Page

Terminal I.D.

003 (Model -12)

2-2

Keyboard Country

USA

2-5

Keyboard Style

Regular

2-6

Control+ASCII Off

2-7

Turbo Off

2-7

Numeric Keypad Off

2-8

Auto Direct Connect Off

2-8

Keyboard Modifiers

Communication (RS-232) Selections Baud Rate

9600 bps

2-10

Word Length Data Bits

7

2-11

Word Length Stop Bits

1

2-11

Parity

Even

2-11

RTS/CTS off

2-13

XON/XOFF off

2-13

ACK/NAK off

2-13

RS-232 Handshaking

12 - 1

Page 132

Parameter

Default Setting

Page

Wand Emulation Connection

Code 39 Format

2-14

Wand Emulation Transmission Rate

25 inches/second

2-15

Wand Emulation Polarity

Black High

2-15

Wand Emulation Idle

High

2-16

Wand Emulation Selections

PDF417 Wand Emulation Selections Data Block Size

60

2-16

Data Between Blocks

50ms

2-17

Overall Checksum

Off

2-17

Scan Rate

270 scans/second

3-1

Beeper Volume

High

3-1

Beeper Tone

Normal

3-2

Scan Voting

Voting Normal

3-2

Quiet Zone

Don’t Reduce

3-2

Reread Delay

Short

3-3

Good Read Delay

No Delay

3-4

Trigger Mode

Manual/Serial (IT3800) Automatic (IT3900)

3-4

Serial Trigger Time Out

0 (infinite)

3-5

Output Selections

12 - 2

Page 133

Parameter

Default Setting

Page

Prefix

None

4-4

Suffix

None

4-4

Function Code Transmit

Enable

4-7

Data Formatter

On/None

5-5

Data Editing Selections

Secondary Interface Selections Code 39 Wand Emulation

Code 39 Format

6-1

Non Decoded Output Laser Emulation Transmission Rate

36 inches/second

6-2

Non Decoded Output Laser Emulation Polarity

White High

6-2

Non Decoded Laser Emulation Idle

High

6-3

Disabling the Secondary Interface

Disabled

6-3

Secondary Trigger Mode

Manual Trigger, Low Power Timeout 2 minutes

6-3

Codabar

On

7-2

Start/Stop

Don’t Transmit

7-2

Check Character

Not Required

7-3

Concatenation

On

7-4

Codabar Message Length

Min 4, Max 60

7-5

Code 39

On

7-6

Start/Stop

Don’t Transmit

7-6

Check Character

Not Required

7-7

Codabar Selections

Code 39 Selections

12 - 3

Page 134

Parameter

Default Setting

Page

Code 39 Message Length

Min 0, Max 48

7-8

Code 39 Append

Off

7-8

Base 32

Off

7-8

Full ASCII

On

7-9

Interleaved 2 of 5

On

7-10

Check Digit

Not Required

7-10

Interleaved 2 of 5 Message Length

Min 4, Max 80

7-11

Strict Decoding

Off

7-11

Code 93

On

7-12

Code 93 Message Length

Min 0, Max 80

7-12

Code 2 of 5

On

7-13

Code 2 of 5 Message Length

Min 4, Max 48

7-13

IATA Code 2 of 5

On

7-14

IATA Code 2 of 5 Message Length

Min 4, Max 48

7-14

Matrix 2 of 5

On

7-15

Matrix 2 of 5 Message Length

Min 4, Max 80

7-15

Interleaved 2 of 5 Selections

Code 93 Selections

Code 2 of 5 Selections

IATA Code 2 of 5 Selections

Matrix 2 of 5 Selections

12 - 4

Page 135

Parameter

Default Setting

Page

Code 11

On

7-16

Check Digits Required

2

7-16

Message Length

Min 4, Max 80

7-17

Code 128

On

7-18

<GS> Substitution

Off

7-18

Code 128 Message Length

Min 0, Max 80

7-19

Telepen

On

7-20

Telepen Output

AIM Telepen

7-20

Telepen Message Length

Min 1, Max 60

7-21

UPC A

On

7-22

Check Digit

On

7-22

Number System

On

7-22

2-Digit Addenda

Off

7-23

5-Digit Addenda

Off

7-23

Addenda Required

Off

7-23

Addenda Separator

On

7-24

UPC Strict Decoding

Off

7-24

On

7-25

Code 11 Selections

Code 128 Selections

Telepen Selections

UPC A

UPC E UPC E0

12 - 5

Page 136

Parameter

Default Setting

Page

UPC E1

Off

7-25

UPC E Expand

Off

7-25

Check Digit

On

7-26

Number System

On

7-26

2-Digit Addenda

Off

7-27

5-Digit Addenda

Off

7-27

Addenda Required

Off

7-27

Addenda Separator

On

7-28

EAN/JAN 13

On

7-29

Check Digit

On

7-29

2-Digit Addenda

Off

7-30

5-Digit Addenda

Off

7-30

Addenda Required

Off

7-30

Addenda Separator

On

7-31

ISBN Enable

Off

7-31

EAN/JAN 8

On

7-32

Check Digit

On

7-32

2-Digit Addenda

Off

7-33

5-Digit Addenda

Off

7-33

Addenda Required

Off

7-33

Addenda Separator

On

7-34

EAN/JAN 13

EAN/JAN 8

12 - 6

Page 137

Parameter

Default Setting

Page

MSI

Off

7-35

Check Character

Validate Type 10, but Don’t Transmit

7-35

MSI Message Length

Min 4, Max 48

7-36

Plessey

Off

7-37

Plessey Message Length

Min 4, Max 48

7-37

RSS-14

Off

7-38

RSS-14 Limited

Off

7-38

RSS-14 Expanded

Off

7-39

RSS-14 Expanded Message Length

Min 4, Max 74

7-39

China Post Code

Off

7-40

China Post Code Message Length

Min 4, Max 80

7-40

MSI Selections

Plessey Selections

RSS-14 Selections

China Post Code

PDF417 Symbology Selections PDF417

On

7-41

PDF417 Message Length

Min 1, Max 2750

7-42

Show GLI Blocks

Off

7-42

Scan Diagnostics

Off

7-42

PDF Learn Mode

Off

7-43

12 - 7

Page 138

Parameter

Default Setting

Page

MicroPDF417

Off

7-44

MicroPDF417 Message Length

Min 1, Max 366

7-45

MicroPDF417 Selections

EAN•UCC Composite Symobology Selections EAN•UCC Composite Symbology

Off

7-46

Enable UPC/EAN Version

Off

7-46

EAN•UCC Composite Symbology Message Length

Min 1, Max 2400

7-47

12 - 8