The text of a manual · part 17 of 22
IMAGETEAM 3800/3900 Hand Held Linear Imager User's Guide, pages 129 to 138
Pages 129 to 138 of 180: Utilities; Default Charts
The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP IT3800 and HHP IT3900
Page 129
11 Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Chart on page 4-5 for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D. prefix for all symbologies. This is a temporary setting that will be removed when the unit is power cycled.
Add Code I.D. Prefix to All Symbologies
Show Software Revision Scan the bar code below to output the current software revision.
Show Revision
Show Data Format Scan the bar code below to show current data format settings.
Data Format Settings
11 - 1
Page 130
Specular Effect Reduction When the On code is scanned, the first pass read rate and voting threshold are increased. Default = Off.
On
* Off Note: If you want to further limit specular effects, reduce the scan speed using "Scan Rate" on page 3-1.
11 - 2
Page 131
12 Default Charts Resetting the Factory Settings If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want the factory settings restored, scan the Factory Default Settings bar code below.
Factory Default Settings The following chart lists the factory default settings (indicated by an asterisk (*) on the programming pages). Parameter
Default Setting
Page
Terminal I.D.
003 (Model -12)
2-2
Keyboard Country
USA
2-5
Keyboard Style
Regular
2-6
Control+ASCII Off
2-7
Turbo Off
2-7
Numeric Keypad Off
2-8
Auto Direct Connect Off
2-8
Keyboard Modifiers
Communication (RS-232) Selections Baud Rate
9600 bps
2-10
Word Length Data Bits
7
2-11
Word Length Stop Bits
1
2-11
Parity
Even
2-11
RTS/CTS off
2-13
XON/XOFF off
2-13
ACK/NAK off
2-13
RS-232 Handshaking
12 - 1
Page 132
Parameter
Default Setting
Page
Wand Emulation Connection
Code 39 Format
2-14
Wand Emulation Transmission Rate
25 inches/second
2-15
Wand Emulation Polarity
Black High
2-15
Wand Emulation Idle
High
2-16
Wand Emulation Selections
PDF417 Wand Emulation Selections Data Block Size
60
2-16
Data Between Blocks
50ms
2-17
Overall Checksum
Off
2-17
Scan Rate
270 scans/second
3-1
Beeper Volume
High
3-1
Beeper Tone
Normal
3-2
Scan Voting
Voting Normal
3-2
Quiet Zone
Don’t Reduce
3-2
Reread Delay
Short
3-3
Good Read Delay
No Delay
3-4
Trigger Mode
Manual/Serial (IT3800) Automatic (IT3900)
3-4
Serial Trigger Time Out
0 (infinite)
3-5
Output Selections
12 - 2
Page 133
Parameter
Default Setting
Page
Prefix
None
4-4
Suffix
None
4-4
Function Code Transmit
Enable
4-7
Data Formatter
On/None
5-5
Data Editing Selections
Secondary Interface Selections Code 39 Wand Emulation
Code 39 Format
6-1
Non Decoded Output Laser Emulation Transmission Rate
36 inches/second
6-2
Non Decoded Output Laser Emulation Polarity
White High
6-2
Non Decoded Laser Emulation Idle
High
6-3
Disabling the Secondary Interface
Disabled
6-3
Secondary Trigger Mode
Manual Trigger, Low Power Timeout 2 minutes
6-3
Codabar
On
7-2
Start/Stop
Don’t Transmit
7-2
Check Character
Not Required
7-3
Concatenation
On
7-4
Codabar Message Length
Min 4, Max 60
7-5
Code 39
On
7-6
Start/Stop
Don’t Transmit
7-6
Check Character
Not Required
7-7
Codabar Selections
Code 39 Selections
12 - 3
Page 134
Parameter
Default Setting
Page
Code 39 Message Length
Min 0, Max 48
7-8
Code 39 Append
Off
7-8
Base 32
Off
7-8
Full ASCII
On
7-9
Interleaved 2 of 5
On
7-10
Check Digit
Not Required
7-10
Interleaved 2 of 5 Message Length
Min 4, Max 80
7-11
Strict Decoding
Off
7-11
Code 93
On
7-12
Code 93 Message Length
Min 0, Max 80
7-12
Code 2 of 5
On
7-13
Code 2 of 5 Message Length
Min 4, Max 48
7-13
IATA Code 2 of 5
On
7-14
IATA Code 2 of 5 Message Length
Min 4, Max 48
7-14
Matrix 2 of 5
On
7-15
Matrix 2 of 5 Message Length
Min 4, Max 80
7-15
Interleaved 2 of 5 Selections
Code 93 Selections
Code 2 of 5 Selections
IATA Code 2 of 5 Selections
Matrix 2 of 5 Selections
12 - 4
Page 135
Parameter
Default Setting
Page
Code 11
On
7-16
Check Digits Required
2
7-16
Message Length
Min 4, Max 80
7-17
Code 128
On
7-18
<GS> Substitution
Off
7-18
Code 128 Message Length
Min 0, Max 80
7-19
Telepen
On
7-20
Telepen Output
AIM Telepen
7-20
Telepen Message Length
Min 1, Max 60
7-21
UPC A
On
7-22
Check Digit
On
7-22
Number System
On
7-22
2-Digit Addenda
Off
7-23
5-Digit Addenda
Off
7-23
Addenda Required
Off
7-23
Addenda Separator
On
7-24
UPC Strict Decoding
Off
7-24
On
7-25
Code 11 Selections
Code 128 Selections
Telepen Selections
UPC A
UPC E UPC E0
12 - 5
Page 136
Parameter
Default Setting
Page
UPC E1
Off
7-25
UPC E Expand
Off
7-25
Check Digit
On
7-26
Number System
On
7-26
2-Digit Addenda
Off
7-27
5-Digit Addenda
Off
7-27
Addenda Required
Off
7-27
Addenda Separator
On
7-28
EAN/JAN 13
On
7-29
Check Digit
On
7-29
2-Digit Addenda
Off
7-30
5-Digit Addenda
Off
7-30
Addenda Required
Off
7-30
Addenda Separator
On
7-31
ISBN Enable
Off
7-31
EAN/JAN 8
On
7-32
Check Digit
On
7-32
2-Digit Addenda
Off
7-33
5-Digit Addenda
Off
7-33
Addenda Required
Off
7-33
Addenda Separator
On
7-34
EAN/JAN 13
EAN/JAN 8
12 - 6
Page 137
Parameter
Default Setting
Page
MSI
Off
7-35
Check Character
Validate Type 10, but Don’t Transmit
7-35
MSI Message Length
Min 4, Max 48
7-36
Plessey
Off
7-37
Plessey Message Length
Min 4, Max 48
7-37
RSS-14
Off
7-38
RSS-14 Limited
Off
7-38
RSS-14 Expanded
Off
7-39
RSS-14 Expanded Message Length
Min 4, Max 74
7-39
China Post Code
Off
7-40
China Post Code Message Length
Min 4, Max 80
7-40
MSI Selections
Plessey Selections
RSS-14 Selections
China Post Code
PDF417 Symbology Selections PDF417
On
7-41
PDF417 Message Length
Min 1, Max 2750
7-42
Show GLI Blocks
Off
7-42
Scan Diagnostics
Off
7-42
PDF Learn Mode
Off
7-43
12 - 7
Page 138
Parameter
Default Setting
Page
MicroPDF417
Off
7-44
MicroPDF417 Message Length
Min 1, Max 366
7-45
MicroPDF417 Selections
EAN•UCC Composite Symobology Selections EAN•UCC Composite Symbology
Off
7-46
Enable UPC/EAN Version
Off
7-46
EAN•UCC Composite Symbology Message Length
Min 1, Max 2400
7-47
12 - 8