The text of a manual · part 15 of 22
IMAGETEAM 3800/3900 Hand Held Linear Imager User's Guide, pages 119 to 122
Pages 119 to 122 of 180: Cloning; Visual Menu
The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP IT3800 and HHP IT3900
Page 119
8 Cloning The cloning procedure reprograms the software in the “destination” scanner’s memory with software from the “source” scanner. Before using this procedure, determine which scanner will be the source (the scanner containing the desired software). The IMAGETEAM 3800/3900 supports cloning and can act as the source device. The software in the destination scanner will be updated from the source scanner. The destination scanner device must be the same model as the source.
Procedure 1. Use the cloning cable (42204559-01) to connect the two scanners for cloning. 2. Connect the destination scanner to one of the 10 pin modular connectors on the cloning cable. 3. Connect the source scanner (containing the new or updated software) to the remaining 10 pin modular connector on the cloning cable. 4. Connect the power supply to the 4 pin mini-DIN connector located on the cloning cable or the scanner cable. 5. Make sure both units are on, and then scan the “Clone Destination” bar code with the destination scanner.
Clone Destination Bar Code 6. Scan the Clone Source bar code below with the source scanner. The scanner’s “Good Read” LED begins blinking periodically indicating cloning is in process.
Clone Source Bar Code 7. When cloning is complete, the destination scanner will double beep. This procedure takes approximately two minutes. 8. Disconnect the destination scanner from the cloning cable. 9. To clone another scanner, repeat steps 1 through 8.
8-1
Page 120
Caution:
8-2
DO NOT scan the “source” bar code unless you are going to clone a scanner. If you mistakenly scan this bar code, reset the scanner by turning the power off and back on to regain normal operation.
Page 121
9 Visual Menu Visual Menu Introduction Visual Menu provides the ability to configure a scanning device by connecting the scanner to the com port of a PC. Visual Menu allows you to download upgrades to a scanner’s firmware, change programmed parameters, and create and print programming bar codes. Using Visual Menu, you can even set up the configuration for a scanner which is not attached to your PC. This enables one expert user to establish the configuration settings for all the devices your company uses, then save these configuration files for others. A configuration file can be e-mailed or, if you prefer, an expert user can create a bar code (or series of bar codes) which contains all the customized programming parameters, and mail or fax the bar code(s) to any location. Users in other locations can scan the bar code(s) to load in the customized parameters. To communicate with a scanner, Visual Menu requires that the PC have at least one available serial communication port and an RS-232 cable to connect the port to the device. A power supply, which plugs into the cable, is also required.
Visual Menu Operations The Visual Menu program performs the following operations: • Displays all configuration data, and saves the information to a file on your PC. • Configures the device to meet your specific requirements. Visual Menu has all the programming parameters which are available via programming bar codes in this User’s Guide. • Creates and prints a clone bar code which contains the program and configuration data from one device. This bar code can then be used to program additional devices with the same parameters. • Selects a device from a list, then performs offline or online file configuration for that device.
Temporary Visual Menu Configuration For quick download communication configuration, scan the Visual Menu bar code to temporarily configure the scanner for Visual Menu settings.
Visual Menu
9-1
Page 122
Installing Visual Menu from the Web 1. Access the HHP web site at www.hhp.com. 2. Click in the Quick Search text box and enter Visual Menu. 3. Click on Search Now. 4. Click on the entry for Visual Menu. 5. When prompted, select Save File, and save the files to the c:\windows\temp directory. 6. Once you have finished downloading the file, exit the web site. 7. Using Explorer, go to the c:\windows\temp file. 8. Double click on the Visualmenu.exe file. Follow the screen prompts to install the Visual Menu program. 9. To start Visual Menu, from the Start Menu click on Programs, Visual Menu, Visual Menu. Note: If you wish, you can create a shortcut to the Visual Menu executable on your desktop.
Upgrading USB Firmware After you use Visual Menu to upgrade your scanner’s firmware, you need to scan the following bar code to upgrade the USB firmware. You must have the USB interface selected. The upgrade takes about 10 seconds, during which a busy tone is generated.
Upgrade EZUSB Firmware
9-2