The text of a manual · part 14 of 22
IMAGETEAM 3800/3900 Hand Held Linear Imager User's Guide: Symbologies, pages 111 to 118
Pages 111 to 118 of 180, from IMAGETEAM 3800/3900 Hand Held Linear Imager User's Guide
The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP IT3800 and HHP IT3900
Page 111
PDF417 Note: The following selections are for use with the 3800/3900PDF-12 scanner only.
<Default All PDF417 Settings>
PDF417
* On
Off
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the 2-digit value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 1-2750.
7 - 41
Page 112
PDF417, continued Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.
Minimum (Default =1)
Maximum (Default =2750)
Show GLI Blocks Turning Show GLI Blocks On causes GLI commands to be issued where located within their encoded data sequences. When on, the “\” is used as an escape character and natural occurrences of “\” in data are replaced by “\\”. Default = Off.
On
* Off
Scan Diagnostics When Scan Diagnostics is turned on, the scanner sends a report instead of the decoded message. Your terminal displays the diagnostic information first, then the data from the scanned code. Default = Off.
On
* Off
7 - 42
Page 113
PDF417, continued The following list shows the information that appears for the PDF417 symbology. Note: The higher the percentage of unused error correction (UEC), the easier it should be to read each code. PDF 417: x rows, x cols, xx data & xx chks (ECL = x), UEC = xxx% Rows = Number of rows Cols = Number of columns Data = Number of data words Chks = Number of check words ECL = Error Correction Level UEC = Unused Error Correction
PDF Learn Mode This setting tells the scanner to brighten the LED’s when you have an optimal distance between the scanner and the PDF417 code you are attempting to read. Because some PDF417 codes are more compact than others, the reading distance varies from code to code. When you turn on the PDF Learn Mode, the IT3800/3900’s light becomes very bright when you are at the best distance for reading the PDF417 code. Default = Off.
On
* Off
7 - 43
Page 114
MicroPDF417 Note: The following selections are for use with the 3800/3900PDF-12 scanner only.
<Default All MicroPDF417 Settings>
MicroPDF417
On
* Off
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the 2-digit value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 1-366.
7 - 44
Page 115
MicroPDF417, continued Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.
Minimum (Default =1)
Maximum (Default = 366)
7 - 45
Page 116
EAN•UCC Composite Symbology Note: The following selections are for use with the 3800/3900PDF-12 scanner only.
< Default All EAN•UCC Composite Symbology Settings >
EAN•UCC Composite Linear codes are combined with a unique 2D composite component to form a new class called EAN•UCC Composite Symbology. EAN•UCC Composite Symbology allows for the co-existence of symbologies already in use.
On
*Off
Enable UPC/EAN Version Turn on this selection to decode EAN•UCC composite symbols having a UPC or EAN primary component.
On
*Off
7 - 46
Page 117
EAN•UCC Composite Symbology, continued EAN•UCC Composite Symbology Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum length range = 11000 and Maximum length range = 1-2400. Defaults are Minimum = 1, Maximum = 2400. If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.
Minimum (Default = 1)
Maximum (Default = 2400)
7 - 47
Page 118
7 - 48