Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 5 of 8

ValueTeam 3060 / 80, ImageTeam 3220 User's Guide, pages 37 to 45

Pages 37 to 45 of 71

The original document is the PDF (769 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP IT3220

Page 37

Programming the Scanner

Keyboard Interface Control ♦ Keyboard Layout (Language) Setting ♦ PROGRAM

END(Exit)

Family Code Selection Keyboard Layout

The “Universal Selection” is only for PC/AT, PS/VP, PS/2 and compatible ones in DOS or Windows environment which can perform unique output without Caps Lock on/off (Output Style) concern. All transmitted data will follow the original full ASCII form. You also need not worry about the upper/lower case control.

Parameter Selection

Option Code

USA (QWERTY) u

00

France (AZERTY)

01

Germany (QWERTZ)

02

United Kingdom - UK (QWERTY)

03

Canadian French (QWERTY)

04

Spain (QWERTY)

05

Sweden/Finland (QWERTY)

06

Portugal (QWERTY)

07

Norway (QWERTY)

08

Latin America (QWERTY)

09

Italy (QWERTY)

10

Netherlands (QWERTY)

11

Denmark (QWERTY)

12

Belgium (AZERTY)

13

Switzerland-Germany (QWERTY)

14

Iceland (QWERTY)

15

Universal (only available for IBM PC/AT, PS/VP in MS DOS and Windows Mode)

99

§ Please refer to the ASCII/HEX Table listed in Appendix A to determine HEX codes for characters, symbols, and functions to be used as premble or postamble. § To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-25 first. § Keyboard Interface Message String : Preamble

Data Length

Prefix Symbol ID

Scanned Data

Suffix Symbol ID

Postamble

Record Suffix

1-15 characters

2-3 digits

1 or 2 characters variable length

1 or 2 characters

1-15 characters

1 character

3-21

Page 38

Programming the Scanner

Keyboard Interface Control ♦ Record Suffix, Preamble, Postamble & Delay Setting ♦ PROGRAM

END(Exit)

Family Code Selection Record Suffix

Parameter Selection None

0

RETURNu

1

TAB

2

SPACE

3

ENTER (Numeric Key Pad)

4

User defined character (1 character)

Preamble

Option Code

5, (00-7F) FIN

None u

[00-7F], [FIN]

1-15 characters Maximum 15-character input; scan “FIN” to terminate this selection.

Postamble

FIN

None u

[00-7F], [FIN]

1-15 characters Maximum 15-character input; scan “FIN” to terminate this selection.

Character Frame Control

FIN

None u

(2 digits)

1-99 msec. Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

Intermessage Delay

FIN

None u

(2 digits)

1-99 (x5) msec. Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

Intercharacter Delay

FIN

None u

(2 digits)

1-99 msec. Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

3-22

Page 39

Programming the Scanner

Keyboard Interface Control ♦ Caps Lock Control & Emulation Setting ♦ PROGRAM

END(Exit)

Family Code Selection Caps Lock Control

Function Key Emulation

Parameter Selection

Option Code

“Caps Lock Off” State u

0

“Caps Lock On” State

1

Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)

2

Enable ASCII 00-31 code as keyboard function code output u

0

Ctrl-Output

1

Refer to Appendix – Keyboard Function Code Table for details.

Key Pad Emulation

Upper/Lower Case

Disable key pad emulation u

0

Enable numeric output as key pad (Num Lock On) output

1

Normal case (neglect the upper/lower case control) u

0

Inverse case (change all characters output to inverse case)

1

Upper case (force all characters output as upper case)

2

Lower case (force all characters output as lower case)

3

§ Character Frame Control is used to adjust timing gap between bytes within one character data output by the scanner. Intercharacter Delay is a time delay between data characters output by the scanner. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters. § Intermessage Delay is a time delay between messages output by the scanner. Increasing this delay will help host applications process the incoming data on time. § The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines. While selecting the other host interfaces, these selections don’t perform the above functions. § Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “Caps Lock Off” state, then the scanner will perform normal data transmission. If the Caps Lock state is on, select “Caps Lock On” state. Select “Auto Detect,” the scanner will perform special transmission handshaking without changing the status of Caps Lock switch.

3-23

Page 40

Programming the Scanner

Serial Interface Control ♦ Record Suffix, Handshaking & Time Out Setting ♦ PROGRAM

END(Exit)

Family Code Selection STX/ETX Control

Parameter Selection

Option Code

Disable STX/ETX transmission u

0

Enable STX/ETX transmission

1

STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.

Record Suffix

None

0

CR (0DH) u

1

LF (0AH)

2

CRLF (0D0AH)

3

TAB (09H)

4

SPACE (20H)

5

EOT (04H)

6 7, (00-7F)

User defined character (1 character)

Preamble

FIN

None u

[00-7F],[FIN]

1-15 characters Maximum 15-character input; scan “FIN” to terminate this selection.

Postamble

FIN

None u

[00-7F],[FIN]

1-15 characters Maximum 15-character input; scan “FIN” to terminate this selection. §

Serial Interface Message String : STX

Preamble

Data Length

Prefix Symbol ID Scanned Data Suffix Symbol ID

1 character

1-15 characters

2-3 digits

1 or 2 characters variable length 1 or 2 characters 1-15 characters

3-24

Postamble

ETX

Record Suffix

1 character

1 character

Page 41

Programming the Scanner

Serial Interface Control ♦ Baud Rate & Data Frame Setting ♦ PROGRAM

END(Exit)

Family Code Selection Handshaking Protocol

Baud Rate (BPS)

Data Frame

Parameter Selection None (free running mode) u

0

RTS/CTS (hardware handshaking)

1

ACK/NAK (software handshaking)

2

Xon/Xoff (software handshaking)

3

38.4K BPS

2400 BPS

0

4

19.2K BPS

1200 BPS

1

5

9600 BPS u

600 BPS

2

6

4800 BPS

300 BPS

3

7

8, None, 1 u

7, Space, 1

0

8

8, Odd, 1

7, Mark, 1

1

9

8, Even, 1

7, None, 2

2

A

8, Space, 1

7, Odd, 2

3

B

8, Mark, 1

7, Even, 2

4

C

8, None, 2

7, Space, 2

5

D

7, Odd, 1

7, Mark, 2

6

E

7

7, Even, 1

Time Out Control

Option Code

None

1 second

0

3

200 mseconds

2 seconds

1

4

500 mseconds u

5 seconds

2

User defined value (seconds)

5 6, (2 digits)

§ When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data communication. This option is very helpful to ensure the reliability of data communication. § When the ACK/NAK Software Handshaking option is selected, the scanner waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after each data transmission. If the NAK is received, the scanner will re-send the data until receiving ACK. § The Time Out Control is a pre-defined delay time for the scanner to wait for handshaking, acknowledgment or non-acknowledgment from the host computer.

3-25

Page 42

Programming the Scanner

Wand Emulation Control ♦ Output Polarity, Singal State, Margin/Module Time, etc.♦ PROGRAM

END(Exit)

Family Code Selection Output Polarity

Parameter Selection

Option Code

High level (5Vdc) on Bar (low level on Space) u

0

Low level (0Vdc) on Bar (high level on Space)

1

Determine the output voltage level for both bar and space.

Initial Signal State

High Level (5Vdc) u

0

Low Level (0Vdc)

1

Determine the initial state of output voltage level.

Margin Time

Module Time

10 mseconds

30 mseconds

0

4

15 mseconds

50 mseconds

1

5

20 mseconds u

2

6

25 mseconds

100 mseconds Delay time before data transmission

Extremely short

Long

0

Short

Code 39 Emulation

3

1 Time base of minimum narrow bar

Medium u

Narrow/Wide Ratio

3

2

1:2 u

0

1:2.5

1

1:3

2

Disable standard Code 39 emulation u

0

Enable standard Code 39 skip emulation

1

Enable standard Code 39 replace emulation

2

§ [ Code 39 Skip ] : When this option is selected, all scanned data will be translated as Standard Code 39 wand emulation output. If any lower case characters are read, they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be skipped. § [ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set will be translated as Space.

3-26

Page 43

Programming the Scanner

Trigger Modes

Alternative Mode When this operation mode is selected, the scanner keeps the light source of the scanner turned on and disables the infrared sensor before the pre-defined auto power off duration. Because you do not have to press the trigger frequently, it is very convenient for multiple scanning. After each good read, the auto power off timer counter is reset. After the scanner turns off the light source, you must press the trigger to turn on the light source again. If there is no scanning operation in pre-defined auto power off duration, the scanner turns off the light source and enables the infrared sensor after the pre-defined auto power off duration

This section allows the user to select the trigger mode that is different from the Trigger Mode default. The operations of each trigger mode are described as below. Low Power Mode When this operation mode is selected, the scanner goes into idle state after scanning the bar code. You must press the trigger to wake up the scanner for operation. While the scanner is in the idle state, there is only maximum 500uA standby current for the entire reading device. It is very helpful for mobile data collection and application, which are concerned with power savings, but please keep a minimum of 120 milliseconds debounce time to stabilize the power transition.

Presentation Mode When this operation mode is selected, the scanner flashes the light source of the scanner without using the trigger. If the scanner detects an image similar to a bar code, the scanner forces on the light source automatically and scans. If the scanner cannot detect a bar code, it resets the light source immediately to blinking. Adjusting the Pulse Driven Duty Cycle can change the frequency of the blinking.

Manual Trigger Mode When this operation mode is selected, you must press the trigger to turn on the light source of the scanner before scanning the bar code. If you do not press the trigger, the light source will be turned off immediately. Please note that the scanner maintains standby current. You can adjust the debounce time to get faster triggering reading.

Auto Trigger Mode (Continued Power On) When this operation mode is selected, the light source of the scanner is forced on for continued operation without pressing the trigger switch. This mode is convenient for high speed bar code reading.

Level Mode (Auto Power Off)

Toggle Mode (Repeat Reading)

When this operation mode is selected, the scanner continues to turn on the light source of the scanner before a good read or pre-defined auto power off duration. If the scanner decodes a bar code successfully, it turns off the light source immediately. After the scanner turns off the light source, you must press the trigger to turn on the light source again. If there is no scanning operation performed during the pre-defined auto power off time, the scanner enters the idle state after the pre-defined auto power off duration.

The toggle mode is very similar to the Alternative Mode without the pre-defined auto power off duration concern. When this operation mode is selected, you must press the trigger to turn on the light source of the scanner. The scanner keeps the light source turned on until you press the trigger again.

3-27

Page 44

Programming the Scanner

Scanning Tolerance

8.Diagnostic Mode (Test Reading) This operation mode is specifically designed for diagnostic purposes. When this operation mode is selected, the light source of the scanner is forced on without regard for other programmable parameters, such as double scan verification, redundancy, and so forth.

(Print Quality Control) This parameter provides the user with a helpful tool to use when the printing quality of the bar code is poor. The regular image distortion acceptance of the scanner is designed to accept up to +/- 200% tolerance. With this feature you can increase the acceptable tolerance if you are using poorly printed or overly printed bar code labels. To reduce the error reading rate further, we also recommend that you limit the number of enabled symbologies to only those that you need to read, and to also limit the minimum and maximum reading of each enabled bar code symbology.

3-28

Page 45

Programming the Scanner

Operation Control ♦ Trigger Mode, Buzzer Tone, Scanning Tolerance ♦ PROGRAM

END(Exit)

Family Code Selection Operation Mode

Buzzer Tone Adjust

Scanning Tolerance

(Printing Quality Control)

Parameter Selection

Option Code

Low Power mode (Low Power triggering)

0

Manual trigger (External triggering) u

1

Level mode (Auto power off)

2

Alternative mode (Periodic power off)

3

Presentation mode (Pulse driven reading)

4

Auto trigger mode (Continued power on)

5

Toggle mode (Repeat reading)

6

Diagnostic mode (Test reading)

7

Buzzer tone - mute

0

Buzzer tone - low

1

Buzzer tone - medium u

2

Buzzer tone - high

3

Buzzer tone - extremely high

4

Good-read beep before data transmission u

5

Good-read beep after data transmission

6

Power-on beep u

7

No power-on beep

8

Regular (standard) printing quality u

0

Poor (critical) printing quality

1

Please note that if you select “Poor printing quality,” you should limit “Readable Bar Code Symbology” and “Minimum & Maximum Reading Length” of each symbology to avoid error reading.

§ The “Scanning Tolerance” is specially designed for the most popular symbologies, such as Code 39, UPC, and EAN.