Page 37
Programming the Scanner
Keyboard Interface Control ♦ Keyboard Layout (Language) Setting ♦ PROGRAM
END(Exit)
Family Code Selection Keyboard Layout
The “Universal Selection” is only for PC/AT, PS/VP, PS/2 and compatible ones in DOS or Windows environment which can perform unique output without Caps Lock on/off (Output Style) concern. All transmitted data will follow the original full ASCII form. You also need not worry about the upper/lower case control.
Parameter Selection
Option Code
USA (QWERTY) u
00
France (AZERTY)
01
Germany (QWERTZ)
02
United Kingdom - UK (QWERTY)
03
Canadian French (QWERTY)
04
Spain (QWERTY)
05
Sweden/Finland (QWERTY)
06
Portugal (QWERTY)
07
Norway (QWERTY)
08
Latin America (QWERTY)
09
Italy (QWERTY)
10
Netherlands (QWERTY)
11
Denmark (QWERTY)
12
Belgium (AZERTY)
13
Switzerland-Germany (QWERTY)
14
Iceland (QWERTY)
15
Universal (only available for IBM PC/AT, PS/VP in MS DOS and Windows Mode)
99
§ Please refer to the ASCII/HEX Table listed in Appendix A to determine HEX codes for characters, symbols, and functions to be used as premble or postamble. § To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-25 first. § Keyboard Interface Message String : Preamble
Data Length
Prefix Symbol ID
Scanned Data
Suffix Symbol ID
Postamble
Record Suffix
1-15 characters
2-3 digits
1 or 2 characters variable length
1 or 2 characters
1-15 characters
1 character
3-21
Page 38
Programming the Scanner
Keyboard Interface Control ♦ Record Suffix, Preamble, Postamble & Delay Setting ♦ PROGRAM
END(Exit)
Family Code Selection Record Suffix
Parameter Selection None
0
RETURNu
1
TAB
2
SPACE
3
ENTER (Numeric Key Pad)
4
User defined character (1 character)
Preamble
Option Code
5, (00-7F) FIN
None u
[00-7F], [FIN]
1-15 characters Maximum 15-character input; scan “FIN” to terminate this selection.
Postamble
FIN
None u
[00-7F], [FIN]
1-15 characters Maximum 15-character input; scan “FIN” to terminate this selection.
Character Frame Control
FIN
None u
(2 digits)
1-99 msec. Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.
Intermessage Delay
FIN
None u
(2 digits)
1-99 (x5) msec. Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.
Intercharacter Delay
FIN
None u
(2 digits)
1-99 msec. Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.
3-22
Page 39
Programming the Scanner
Keyboard Interface Control ♦ Caps Lock Control & Emulation Setting ♦ PROGRAM
END(Exit)
Family Code Selection Caps Lock Control
Function Key Emulation
Parameter Selection
Option Code
“Caps Lock Off” State u
0
“Caps Lock On” State
1
Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)
2
Enable ASCII 00-31 code as keyboard function code output u
0
Ctrl-Output
1
Refer to Appendix – Keyboard Function Code Table for details.
Key Pad Emulation
Upper/Lower Case
Disable key pad emulation u
0
Enable numeric output as key pad (Num Lock On) output
1
Normal case (neglect the upper/lower case control) u
0
Inverse case (change all characters output to inverse case)
1
Upper case (force all characters output as upper case)
2
Lower case (force all characters output as lower case)
3
§ Character Frame Control is used to adjust timing gap between bytes within one character data output by the scanner. Intercharacter Delay is a time delay between data characters output by the scanner. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters. § Intermessage Delay is a time delay between messages output by the scanner. Increasing this delay will help host applications process the incoming data on time. § The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines. While selecting the other host interfaces, these selections don’t perform the above functions. § Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “Caps Lock Off” state, then the scanner will perform normal data transmission. If the Caps Lock state is on, select “Caps Lock On” state. Select “Auto Detect,” the scanner will perform special transmission handshaking without changing the status of Caps Lock switch.
3-23
Page 40
Programming the Scanner
Serial Interface Control ♦ Record Suffix, Handshaking & Time Out Setting ♦ PROGRAM
END(Exit)
Family Code Selection STX/ETX Control
Parameter Selection
Option Code
Disable STX/ETX transmission u
0
Enable STX/ETX transmission
1
STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
Record Suffix
None
0
CR (0DH) u
1
LF (0AH)
2
CRLF (0D0AH)
3
TAB (09H)
4
SPACE (20H)
5
EOT (04H)
6 7, (00-7F)
User defined character (1 character)
Preamble
FIN
None u
[00-7F],[FIN]
1-15 characters Maximum 15-character input; scan “FIN” to terminate this selection.
Postamble
FIN
None u
[00-7F],[FIN]
1-15 characters Maximum 15-character input; scan “FIN” to terminate this selection. §
Serial Interface Message String : STX
Preamble
Data Length
Prefix Symbol ID Scanned Data Suffix Symbol ID
1 character
1-15 characters
2-3 digits
1 or 2 characters variable length 1 or 2 characters 1-15 characters
3-24
Postamble
ETX
Record Suffix
1 character
1 character
Page 41
Programming the Scanner
Serial Interface Control ♦ Baud Rate & Data Frame Setting ♦ PROGRAM
END(Exit)
Family Code Selection Handshaking Protocol
Baud Rate (BPS)
Data Frame
Parameter Selection None (free running mode) u
0
RTS/CTS (hardware handshaking)
1
ACK/NAK (software handshaking)
2
Xon/Xoff (software handshaking)
3
38.4K BPS
2400 BPS
0
4
19.2K BPS
1200 BPS
1
5
9600 BPS u
600 BPS
2
6
4800 BPS
300 BPS
3
7
8, None, 1 u
7, Space, 1
0
8
8, Odd, 1
7, Mark, 1
1
9
8, Even, 1
7, None, 2
2
A
8, Space, 1
7, Odd, 2
3
B
8, Mark, 1
7, Even, 2
4
C
8, None, 2
7, Space, 2
5
D
7, Odd, 1
7, Mark, 2
6
E
7
7, Even, 1
Time Out Control
Option Code
None
1 second
0
3
200 mseconds
2 seconds
1
4
500 mseconds u
5 seconds
2
User defined value (seconds)
5 6, (2 digits)
§ When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data communication. This option is very helpful to ensure the reliability of data communication. § When the ACK/NAK Software Handshaking option is selected, the scanner waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after each data transmission. If the NAK is received, the scanner will re-send the data until receiving ACK. § The Time Out Control is a pre-defined delay time for the scanner to wait for handshaking, acknowledgment or non-acknowledgment from the host computer.
3-25
Page 42
Programming the Scanner
Wand Emulation Control ♦ Output Polarity, Singal State, Margin/Module Time, etc.♦ PROGRAM
END(Exit)
Family Code Selection Output Polarity
Parameter Selection
Option Code
High level (5Vdc) on Bar (low level on Space) u
0
Low level (0Vdc) on Bar (high level on Space)
1
Determine the output voltage level for both bar and space.
Initial Signal State
High Level (5Vdc) u
0
Low Level (0Vdc)
1
Determine the initial state of output voltage level.
Margin Time
Module Time
10 mseconds
30 mseconds
0
4
15 mseconds
50 mseconds
1
5
20 mseconds u
2
6
25 mseconds
100 mseconds Delay time before data transmission
Extremely short
Long
0
Short
Code 39 Emulation
3
1 Time base of minimum narrow bar
Medium u
Narrow/Wide Ratio
3
2
1:2 u
0
1:2.5
1
1:3
2
Disable standard Code 39 emulation u
0
Enable standard Code 39 skip emulation
1
Enable standard Code 39 replace emulation
2
§ [ Code 39 Skip ] : When this option is selected, all scanned data will be translated as Standard Code 39 wand emulation output. If any lower case characters are read, they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be skipped. § [ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set will be translated as Space.
3-26
Page 43
Programming the Scanner
Trigger Modes
Alternative Mode When this operation mode is selected, the scanner keeps the light source of the scanner turned on and disables the infrared sensor before the pre-defined auto power off duration. Because you do not have to press the trigger frequently, it is very convenient for multiple scanning. After each good read, the auto power off timer counter is reset. After the scanner turns off the light source, you must press the trigger to turn on the light source again. If there is no scanning operation in pre-defined auto power off duration, the scanner turns off the light source and enables the infrared sensor after the pre-defined auto power off duration
This section allows the user to select the trigger mode that is different from the Trigger Mode default. The operations of each trigger mode are described as below. Low Power Mode When this operation mode is selected, the scanner goes into idle state after scanning the bar code. You must press the trigger to wake up the scanner for operation. While the scanner is in the idle state, there is only maximum 500uA standby current for the entire reading device. It is very helpful for mobile data collection and application, which are concerned with power savings, but please keep a minimum of 120 milliseconds debounce time to stabilize the power transition.
Presentation Mode When this operation mode is selected, the scanner flashes the light source of the scanner without using the trigger. If the scanner detects an image similar to a bar code, the scanner forces on the light source automatically and scans. If the scanner cannot detect a bar code, it resets the light source immediately to blinking. Adjusting the Pulse Driven Duty Cycle can change the frequency of the blinking.
Manual Trigger Mode When this operation mode is selected, you must press the trigger to turn on the light source of the scanner before scanning the bar code. If you do not press the trigger, the light source will be turned off immediately. Please note that the scanner maintains standby current. You can adjust the debounce time to get faster triggering reading.
Auto Trigger Mode (Continued Power On) When this operation mode is selected, the light source of the scanner is forced on for continued operation without pressing the trigger switch. This mode is convenient for high speed bar code reading.
Level Mode (Auto Power Off)
Toggle Mode (Repeat Reading)
When this operation mode is selected, the scanner continues to turn on the light source of the scanner before a good read or pre-defined auto power off duration. If the scanner decodes a bar code successfully, it turns off the light source immediately. After the scanner turns off the light source, you must press the trigger to turn on the light source again. If there is no scanning operation performed during the pre-defined auto power off time, the scanner enters the idle state after the pre-defined auto power off duration.
The toggle mode is very similar to the Alternative Mode without the pre-defined auto power off duration concern. When this operation mode is selected, you must press the trigger to turn on the light source of the scanner. The scanner keeps the light source turned on until you press the trigger again.
3-27
Page 44
Programming the Scanner
Scanning Tolerance
8.Diagnostic Mode (Test Reading) This operation mode is specifically designed for diagnostic purposes. When this operation mode is selected, the light source of the scanner is forced on without regard for other programmable parameters, such as double scan verification, redundancy, and so forth.
(Print Quality Control) This parameter provides the user with a helpful tool to use when the printing quality of the bar code is poor. The regular image distortion acceptance of the scanner is designed to accept up to +/- 200% tolerance. With this feature you can increase the acceptable tolerance if you are using poorly printed or overly printed bar code labels. To reduce the error reading rate further, we also recommend that you limit the number of enabled symbologies to only those that you need to read, and to also limit the minimum and maximum reading of each enabled bar code symbology.
3-28
Page 45
Programming the Scanner
Operation Control ♦ Trigger Mode, Buzzer Tone, Scanning Tolerance ♦ PROGRAM
END(Exit)
Family Code Selection Operation Mode
Buzzer Tone Adjust
Scanning Tolerance
(Printing Quality Control)
Parameter Selection
Option Code
Low Power mode (Low Power triggering)
0
Manual trigger (External triggering) u
1
Level mode (Auto power off)
2
Alternative mode (Periodic power off)
3
Presentation mode (Pulse driven reading)
4
Auto trigger mode (Continued power on)
5
Toggle mode (Repeat reading)
6
Diagnostic mode (Test reading)
7
Buzzer tone - mute
0
Buzzer tone - low
1
Buzzer tone - medium u
2
Buzzer tone - high
3
Buzzer tone - extremely high
4
Good-read beep before data transmission u
5
Good-read beep after data transmission
6
Power-on beep u
7
No power-on beep
8
Regular (standard) printing quality u
0
Poor (critical) printing quality
1
Please note that if you select “Poor printing quality,” you should limit “Readable Bar Code Symbology” and “Minimum & Maximum Reading Length” of each symbology to avoid error reading.
§ The “Scanning Tolerance” is specially designed for the most popular symbologies, such as Code 39, UPC, and EAN.
3-29