Page 46

Programming the Scanner

Advanced Operation Control This section allows the user to program the following parameters for advance operation control. The definitions of each parameter are described below. Reread Delay This feature is designed to inhibit the scanner from reading the same bar code within a certain period of time. The time period can be programmed for immediate, short, medium, or long time out duration. Another selection is Force Verification which will not allow reading of the same bar code twice even after a very long duration. It should also note that this feature is not available if you have selected Low Power Mode, Manual Trigger Mode, Level Mode or Diagnostic Mode.

Pluse Driven Duty The Pulse Driven Duty is designed to control the flashing frequency of the light source. For example, the 1/2 duty cycle means that the scanner turns on the light source at a time equal to 1/2 the duty cycle. Generally speaking, the higher scan rate will take the higher duty.

Debounce Time Control

Scan Voting Scan Voting is the number of times the same bar code is decoded before it is transmitted. This feature is useful when the bar codes being read are of poor quality. It should also be noted that this feature is not available if you have selected Low Power Mode, Manual Trigger Mode, Level Mode, or Diagnostic Mode.

Auto Power Off Duration The Auto Power Off Duration is a pre-defined power off time out counter for Level Mode and Alternative Mode. You can adjust this parameter to meet your own application requirement.

3-30

In an effort to stabilize the sometime erratic signals that occur during power transition, a time delay is added. Increasing the debounce time decreases reading errors, but also reduces reading performance a little.

Page 47

Programming the Scanner

Operation Control ♦ Reread Delay, Scan Voting ♦ PROGRAM

END(Exit)

Family Code Selection Reread Delay

Scan Voting

Auto Power Off Duration

Pulse Driven Duty

Debounce Time Control

Dollar Sign Control

Parameter Selection

Option Code

Disable

Long time out duration

0

4

Immediate time out duration

Force Verification

1

5

Short time out duration u

2

Medium time out duration

3

None

4 times

0

4

1 time

5 times

1

5

2 times u

2

3 times

3

Short (around 2 seconds)

0

Medium (around 3-4 seconds)

1

Long (around 5-6 seconds)

2

Extremely long (around 7-8 seconds) u

3

1/2 duty cycle u

0

2/3 duty cycle

1

3/4 duty cycle

2

4/5 duty cycle

3

None u

120 mseconds

0

4

20 mseconds

150 mseconds

1

5

50 mseconds

200 mseconds

2

6

100 mseconds

250 mseconds

3

7

Dollar sign output as “$” u

0

Dollar sign output as “Japanese Yen”

1 2

3-31

Page 48

Programming the Scanner

Condensed Data Editor ♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦ PROGRAM

END(Exit)

Family Code Selection Preamble

Parameter Selection

Option Code FIN

None u 1-15 characters (use hex value for each character)

[00-7F], [FIN]

Maximum 15-character input; scan “FIN” to terminate this selection.

Postamble

FIN

None u 1-15 characters (use hex value for each character)

[00-7F], [FIN]

Maximum 15-character input; scan “FIN” to terminate this selection.

Data Length Transmission

Disable u

0

Enable 2-digits data length transmission

1

If data length exceeds 99, 3-digit data length will be transmitted.

Code ID Transmission

Data Pass Control

Disable Code ID transmission u

0

Enable prefix Code ID transmission

1

Enable suffix Code ID transmission

2

Enable both prefix and suffix Code ID transmission

3

Disable u

0

Enable

1

If data verifier is false, the original scanned bar code data will be transmitted. § The Data Editor is a very powerful, Artificial-Intelligence based data editing expert system provided specifically for the 3060B/3080B/3220 bar code scanners. Through the Data Editor, you can process the scanned data prior to transmitting in many ways, such as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It also allow help you to arrange the transmission of scanned data to any specific format. § Due to the resources used by this system, the Full-feature Data Editor is only supported by HHP SET. Through HHP SET, all settings and configurations can be ® done on-screen, under Windows 95/98/NT environment. § A Condensed Version Data Editor is provided here in the manual and is utilized by scanning the programming bar codes.

3-32

Page 49

Programming the Scanner

Condensed Data Editor ♦ Data Formater ♦ PROGRAM

END(Exit)

Family Code Selection Symbology Selection

1st Insertion

2nd Insertion

3rd Insertion

4th Insertion

Parameter Selection

Option Code

2nd Option Code

FIN

Disable u Select one bar code symbology

(2 digits)

Select all bar code symbologies

00 automatic termination automatic termination

Disable u

FIN

Hex value for each

Enable

(2 digits)

character, (FIN)

2-digits identified position; max. 3 insertion characters position

1-3 characters to insert

Disable u

FIN

Hex value for each

Enable

(2 digits)

character, (FIN)

2-digits identified position; max. 3 insertion characters position

1-3 characters to insert

Disable u

FIN

Hex value for each

Enable

(2 digits)

character, (FIN)

2-digits identified position; max. 3 insertion characters position

1-3 characters to insert

Disable u

FIN

Hex value for each

Enable

(2 digits)

character, (FIN)

2-digits identified position; max. 3 insertion characters position

1-3 characters to insert

§ The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computer or terminal. It allows you to select desired bar code symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position. § While the Data Formatter is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbolology ID or Record Suffix. All of the above programmable parameters perform the same function depending on your setting. § Regarding the “Bar Code Selection” and “Position Calculation” of data formatter, please refer to page 3-37 for details. § To determine the hex value for the “Character,” refer to the ASCII/HEX Table listed in Appendix A.

3-33

Page 50

Programming the Scanner

Condensed Data Editor ♦ Data Verifier Setting ♦ PROGRAM

END(Exit)

Family Code Selection Verifier Control

Identified Data Length

Parameter Selection

Option Code

2nd Option Code

FIN

Disable u Select one bar code symbology

(2 digits)

automatic termination

Select all bar code symbologies

00 automatic termination

Disable u

FIN

Enable

(2 digits)

Determine the identified data length for verification.

1st Identified Character

2nd Identified Character

3rd Identified Character

Disable u

FIN

Enable

(2 digits)

2-digits checking position; 1 identified character position

Disable u

FIN

Enable

(2 digits)

2-digits checking position; 1 identified character position

Disable u

FIN

Enable

(2 digits)

2-digits checking position; 1 identified character position

[00-7F]

[00-7F]

[00-7F]

§ The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter. § All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the scanner will not transmit the data to the host computers or terminals, but will instead issue 3 long beeps for verification error and skip the scanned data. § The Data Verifier checks only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. § Regarding the “Bar Code Selection” and “Position Calculation” of Data Verifier, please refer to page 3-37 for details. § To determine the hex value for the “Character,” refer to the ASCII/HEX Table listed in Appendix A.

3-34

Page 51

Programming the Scanner

Condensed Data Editor ♦ Data Replacer Setting ♦ PROGRAM

END(Exit)

Family Code Selection Replacer Control

1st Replacement

2nd Replacement

3rd Replacement

Parameter Selection

Option Code

2nd Option Code

FIN

Disable u Select one bar code symbology

(2 digits)

automatic termination

Select all bar code symbologies

00 automatic termination

Disable u

FIN

Enable

(2 digits)

2-digits identified position; 1 replacement character position

Disable u

FIN

Enable

(2 digits)

2-digits identified position; 1 replacement character position

Disable u

FIN

Enable

(2 digits)

2-digits identified position; 1 replacement character position

[ 00-7F ]

[ 00-7F ]

[ 00-7F ]

§ The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for replacer control, and provides Multiple Position Replcement in the identified position. § All data must conform to the Identified Bar Code Symbologies, and one to three Identified Characters in the identified position While the Data Replacer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. § Regarding the “Bar Code Selection” and “Position Calculation” of Data Replacer, please refer to page 3-37 for details. § To determine the hex value for the “Character,” refer to the ASCII/HEX Table listed in Appendix A.

3-35

Page 52

Programming the Scanner

Condensed Data Editor ♦ Data Organizer Setting ♦ PROGRAM

END(Exit)

Family Code Selection Organizer Control

1st Organization

2nd Organization

Include/Exclude Control

Parameter Selection

Option Code

2nd Option Code

FIN

Disable u Select one bar code symbology

(2 digits)

automatic termination

Select all bar code symbologies

00 automatic termination

Disable u

FIN

Enable

(2 digits)

2-digits identified character position; Transmit data before/after this position position

Disable u

FIN

Enable

(2 digits)

2-digits identified position; Transmit data before/after this position position

Transmitted data excluding the data of identified positionu

0

Transmitted data including the data of identified position

1

Direction : 0 (Before) u 1 (After)

Direction : 0 (Before) u 1 (After)

§ The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for organizer control, and provides maximum two identified positions to send the data before or after. It also allows you to control the transmitted data including or excluding the data of identification position. Please refer to the application example listed in the next page for details. § While the Data Organizer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. § Reagrding the “Bar Code Selection” and “Position Calculation” of Data Organizer, please refer to the next page for details. § To determine the hex value for the “Character,” refer to the ASCII/HEX Table listed in Appendix A.

3-36

Page 53

Programming the Scanner

Select a Bar Code Symbology

Application Example

You can use the Condensed Data Editor for advanced transmission arrangement with one or all bar code symbologies. If you scan “00” to select all types, the scanner arranges all incoming data to meet your pre-defined format. If you want to select only one type bar code, please select one of the option codes listed below.

§ The bar code label is an all-numeric 16-digit Interleaved 2 of 5, which includes the information of 6-digit date code, 6-digit serial number, and 4-digit unit price, in that order. The data code always starts with a “9.” If a scanned bar code meets the above criteria, the data will be separated into three fields. Each field should end with a “TAB.” The first digit of the date code, which is a “9,” should be replaced with an “A.” The serial number should start with SN. The first 2 digits of the unit price should be skipped.

UPC-E : 03 UPC-A : 02 EAN/CAN/JAN-8 : 05 EAN/CAN/JAN-13 : 04 Code 32 : 07

Telepen : 13 Code 128 : 01 UCC/EAN 128 : 01 Code 39 : 07 Code 93 : 09

Codabar/NW-7 : 06 Code 25 Family : 08 Code 11 : 10 UK/Plessey : 12 MSI/Plessey : 11

§ Actual Bar Code read : 9 8 1 0 2 5 1 2 3 4 5 6 9 8 7 6 § Desired Output : A81025[TAB]SN123456[TAB]76[TAB]

Position Calculation

Programming Procedure

[Data Formatter]

If there is a 5-character input data string, refer to the following to calculate the actual position for insertion: X 00

X 01

X 02

X 03

[Important Notice] Please note that Condensed Data Editor will follow the preset working flow as below:

X 04

05

Verifier [Data Verifier, Data Replacer, Data Organizer]

X

X

X

X

X

X

X

X

X

X

00

01

02

03

04

05

06

07

08

09

10

Formatter

Replacer

Organizer

Consequently when you set the identified position in the Data Organizer, you must consider the inserted data that you have already set via Data Formatter.

If there is an 11-character data string, please refer to the following to calculate the actual position for identification. X

3-37

Page 54

Programming the Scanner

[Data Verifier]

A81025[TAB]SN123456[TAB]9876[TAB]. We still need delete the 98 from the string to get the desired output.

§ Scan “Program” to enter the programming mode. § Scan “Verifier Control” and set bar code symbology to “08” (Interleaved 2 of 5).

[Data Organizer]

§ Scan “Identified Data Length” and set the length to “16.”

§ Scan “1st Organization” and set the identified position to “16,” then set the data transmission to “0” (before).

§ Scan “Organizer Control” and set bar code symbology to “08.”

§ Scan “1st Identified Character” and set the identified position to “00,” then set the identified character to “39” (Hex value for 9).

The character position, which counts the added “SN” and TABs, is identified as 00, 01, 02,… so the 16th character is “9.” The

[Data Formatter] § Scan “Formatter Control” and set bar code symbology to “08.” include/exclude control, which will be set to 0 for exclude in the last step of instructions below, determines that the “9” in the 16th position will not be sent. All of the characters before the 16th position will be transmitted.

§ Scan “1st Insertion” and set the identified position to “06,” then inserted characters to “09” (Hex value for TAB), “53” (Hex value for S), “4E” (Hex value for N).

§ Scan “3rd Insertion” and set the identified position to “16,” then inserted character to “09.” Finally, you must scan the “FIN” (Finish) code to terminate this selection.

§ Scan “2nd Organization” and set the identified position to “17,” which is “8,” in this case, then set the data transmission to “1” to transmit all of the characters after position 17. Whether position 17 gets transmitted along with the string is determined by the include/exclude control, which, in this case, will be excluded in the next step.

[Data Replacer]

[Include/Exclude Control]

§ Scan “Replacer Control” and set bar code symbology to “08.”

§ Scan Include/Exclude Control.”

§ Scan “1st Replacement” and set the identified position to “00,” then replaced character to “41” (Hex value for A).

§ Scan “0” for transmitted data excluding the data of identified position.

At this point the data string is as following.

§ Scan “END” (Exit) to terminate the programming.

§ Scan “2nd Insertion” and set the identified position to “12,” then inserted character to “09.” Finally, you must scan the “FIN” (Finish) code to terminate this selection.