Page 28

Programming the Scanner

Symbology Programming ♦ Code ID Transmission and Symbology Enable ♦ PROGRAM

END(Exit)

Family Code Selection Code ID Transmission

Symbology Enable

Remember to scan “FIN” to terminate this selection. But if you select the “ Automatic discrimination ,” Scanner will terminate this selection automatically.

Parameter Selection

Option Code

Disable symbology ID transmission u

0

Enable prefix symbology ID transmission

1

Enable suffix symbology ID transmission

2

Enable both prefix and suffix symbology ID transmission

3

Automatic discrimination u

00

Code 128, UCC/EAN-128

01

UPC-A

02

UPC-E

03

EAN/CAN/JAN-13

04

EAN/CAN/JAN-8

05

Codabar/NW-7

06

Code 39/Code 32, HIBC

07

Code 2 of 5 Family, IATA

08

Code 93

09

Code 11

10

MSI/Plessey

11

UK/Plessey

12

Telepen

13

§ If your application is reading known, limited bar code symbologies, you may increase the reading speed and decrease the reading error possibility by enabling those known symbologies only. Furthermore, to add the “Symbology ID” into the transmitted data is also helpful for applications to identify the specific symbology ID. For example, to enable UPC-A and Code 39 only scan the following bar codes: “PROGRAM,” “Symbology Enable,” “0,” “2,” “0,” “7,” “FIN” and “END.” § To further ensure fast, accurate readings, you can complete more complex configurations via full-feature Data Editor. To configure the full-feature Data Editor, you ® must use the HHP SET which is a Windows 95/98/NT based software utility specially designed for the scanner.

3-12

Page 29

Programming the Scanner

Symbology Programming ♦ Code 39/Code 32 Settings♦ PROGRAM

END(Exit)

Family Code Selection Code 39 Family Setting

Code 39 Min. Length

Parameter Selection

Option Code

Select Standard Code 39 u

0

Select Full ASCII Code 39

1

Select Code 32 (Italian Pharmaceutical)

2

Disable start/stop symbol transmission u

3

Enable start/stop symbol transmission

4

Disable Code 32 leading A transmission u

5

Enable Code 32 leading A transmission

6

Disable MOD 43 check digit verification u

7

Enable MOD 43 check digit verification

8

Disable check digit transmission

9

Enable check digit transmission u

A

Default (04) u

FIN

Minimum length

(2 digits)

Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

Code 39 Max. Length

Default (99) u

FIN

Maximum length

(2 digits)

Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

3-13

Page 30

Programming the Scanner

Symbology Programming ♦ Codabar/NW-7 Setting ♦ PROGRAM

END(Exit)

Family Code Selection Codabar Setting

Codabar Min. Length

Parameter Selection

Option Code

Select Codabar standard format u

0

Select Codabar ABC format

1

Select Codabar CLSI format

2

Select Codabar CX format

3

Disable start/stop symbol transmission u

4

Enable ABCD/ABCD start/stop symbol transmission

5

Enable abcd/abcd start/stop symbol transmission

6

Enable ABCD/TN*E start/stop symbol transmission

7

Enable abcd/tn*e start/stop symbol transmission

8

Disable check digit verification u

9

Enable check digit verification

A

Disable check digit transmission

B

Enable check digit transmission u

C

Default (04) u

FIN

Minimum length

(2 digits)

Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

Codabar Max. Length

Default (99) u

FIN

Maximum length

(2 digits)

Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

3-14

Page 31

Programming the Scanner

Symbology Programming ♦ UPC-A & UPC-E Setting ♦ PROGRAM

END(Exit)

Family Code Selection UPC Family Setting

Parameter Selection

Option Code

Select UPC without supplement digits u

0

Select UPC with only 2 supplement digits

1

Select UPC with only 5 supplement digits

2

Select UPC with 2/5 supplement digits

3

Disable UPC-E ex-pansion u

4

Enable UPC-E expansion

5

Disable UPC standardization u

6

Enable UPC standardization

7

Disable UPC numeric system

8

Enable UPC numeric system u

9

Disable UPC-A check digit transmission

A

Enable UPC-A check digit transmission u

B

Disable UPC-E check digit transmission

C

Enable UPC-E check digit transmission u

D

Disable UPC “leading 1” portion u

E

Enable UPC “leading 1” portion

F

§ UPC-E & EAN-8 Expansion

: Expand the 7-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.

§ UPC-A/E Standardization

: Expand the 7-digit UPC-E and 12-digit UPC-A to 8-digit UPC-8 to 13-digit EAN-13 with 1 zero insertion.

§ UPC Lead 1 Numeric System : Enable to read UPC leading with the 1 numeric system, you must enable this option. WPC Selection (UPC/EAN/JAN/CAN) UPC-A UPC-E EAN/JAN/CAN-13 EAN/JAN/CAN-8

Basic Length 12 7 13 8

Disable Check Digit -1 -1 -1 -1

Disable Numeric System -1 -1 NC NC

With 2-digit Addendum +2 +2 +2 +2

3-15

With 5-digit Addendum +5 +5 +5 +5

Enable Standardization +1 +1 NC NC

Enable Expansion 0 +5 0 +5

Page 32

Programming the Scanner

Symbology Programming ♦ EAN/JAN/CAN & IATASetting ♦ PROGRAM

END(Exit)

Family Code Selection EAN/CAN/JAN Setting

IATA Setting

Parameter Selection

Option Code

Select EAN without supplement digits u

0

Select EAN with only 2 supplement digits

1

Select EAN with only 5 supplement digits

2

Select EAN with 2/5 supplement digits

3

Disable EAN-8 expansion u

4

Enable EAN-8 expansion

5

Disable EAN-13 check digit transmission

6

Enable EAN-13 check digit transmission u

7

Disable EAN-8 check digit transmission

8

Enable EAN-8 check digit transmission u

9

Disable ISBN/ISSN Conversion reading check u

A

Enable ISBN/ISSN Conversion reading check

B

Select 15-digit fixed length IATA checking u

0

Select variable length IATA

1

Disable check digit verification u

2

Enable check digit automatic verification

3

Enable S/N checking digit verification only

4

Enable CPN checking digit verification only

5

Enable CPN, Airline and S/N check digit verification

6

Disable start/stop symbol transmission u

7

Enable start/stop symbol transmission

8

Disable check digit transmission

9

Enable check digit transmission u

A

3-16

Page 33

Programming the Scanner

Symbology Programming ♦ Code 2 of 5 Family & German Post Code Setting ♦ PROGRAM

END(Exit)

Family Code Selection Code 25 Setting

Code 25 Min. Length

Parameter Selection

Option Code

Select any Code 2 of 5 u Select Standard/Industrial 2 of 5 only Select Matrix 2 of 5 only Select Interleaved 2 of 5 only Select Interleaved 2 of 5 S Code only Select IATA only Select China Postal Code only

0 1 2 3 4 5 6

Disable check digit verification u Enable check digit verification

7 8

Disable check digit transmission Enable check digit transmission u Default (06) u

9 A FIN (2 digits)

Minimum length Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

Code 25 Max. Length

Default (99) u

FIN

Maximum length

(2 digits)

Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

German Postal Setting

Disable u

0

Enable

1

§ The scanner can decode almost all Code 2 of 5 symbologies automatically. But we recommend that you select only one kind of Code 2 of 5 for reading, or set limited maximum and minimum reading length for reading, because the encoding algorithm of Code 2 of 5 is not very robust. To decode all Code 2 of 5 automatically or to read variable length Code 2 of 5 will increase the error reading rate.

3-17

Page 34

Programming the Scanner

Symbology Programming ♦ Code 11 & Code 93 Setting ♦ PROGRAM

END(Exit)

Family Code Selection Code 11 Setting

Code 11 Min. Length

Parameter Selection

Option Code

Select 1-check digit verification

0

Select 2-check digit verification u

1

Disable check digit transmission u

2

Enable 1-check digit transmission

3

Enable 2-check digit transmission

4

Default (04) u

FIN

Minimum length

(2 digits)

Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

Code 11 Max. Length

Default (99) u

FIN

Maximum length

(2 digits)

Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

Code 93 Setting

Code 93 Min. Length

Disable check digit transmission u Enable check digit transmission

0 1

Default (03) u

FIN

Minimum length

(2 digits)

Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

Code 93 Max. Length

Default (99) u

FIN

Maximum length

(2 digits)

Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

3-18

Page 35

Programming the Scanner

Symbology Programming ♦ MSI/Plessey, Code 128 & UCC/EAN 128 Setting ♦ PROGRAM

END(Exit)

Family Code Selection MSI/Plessey Setting

MSI/Plessey Min. Length

Parameter Selection

Option Code

Select MOD 10 check digit u

0

Select MOD 10-10 check digit

1

Select MOD 11-10 check digit

2

Disable check digit transmission

3

Enable 1-check digit transmission u

4

Enable 2-check digit transmission

5

Default (04) u

FIN

Minimum length

(2 digits)

Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

MSI/Plessey Max. Length

Default (99) u

FIN

Maximum length

(2 digits)

Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

Code 128/EAN-128 Setting

Code 128/EAN-128 Min. Length

Disable function code conversion u

0

Enable function code conversion

1

Default (04) u

FIN

Minimum length

(2 digits)

Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

Code 128/EAN-128 Max. Length

Default (99) u

FIN

Maximum length

(2 digits)

Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

3-19

Page 36

Programming the Scanner

Symbology Programming ♦ UK/Plessey & Telepen Setting ♦ PROGRAM

END(Exit)

Family Code Selection UK/Plessey Setting

UK/Plessey Min. Length

Parameter Selection

Option Code

Select UK/Plessey Standard Format u Select UK/Plessey CLSI Format

0 1

Disable Convert X to A-F u Enable Convert X to A-F

2 3

Disable check digit transmission u Enable check digit transmission Default (04) u Minimum length

4 5 FIN (2 digits)

Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

UK/Plessey Max. Length

FIN (2 digits)

Default (99) u Maximum length Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

Telepen Setting

Telepen Min. Length

Select Telepen Numeric mode u Select Telepen Full ASCII mode

0 1

Disable check digit transmission u Enable check digit transmission

2 3 FIN (2 digits)

Default (04) u Minimum length Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

Telepen Max. Length

FIN (2 digits)

Default (99) u Maximum length Scan 2 digits from the option code chart in Appendix, then scanner will terminate this selection automatically.

3-20