Page 19
Programming the Scanner
§ General Transmission Control The available parameters include “Preamble,” “Postamble,” “Suffix,” “Symbol ID and Data Length Transmission,” and “Transmission Time Control.”
Data Editor Data Editor is an Artificial Intelligence-based Expert System used to format the scanned data before it is transmitted to the host system. The Data Editor Condensed Version has been embedded in the scanner. You gain access to desired Data Editor’s functions via scanning the menu’s bar code. The Full-Feature Data Editor is only available through HHP SET, which gives you the freedom of modifying the scanned data anyway you like, and allows you to integrate the scanner into any existing application.
§ Advanced Data Verification User can base the specific data format on the desired Bar Code Symbologies to select “Valid ASCII Domain,” “Valid Data Length Domain” and “Matched Data Value” to establish any desired filtering algorithm. This feature not only provides an on-scanner data filter without application software modification, but also reduces the error reading rate and improves data capture reliability.
Data Format Editor The ultra powerful data editing functions provided by Data Editor are controlled by user-defined rules. Through independent rules, users can easily get the following functionality:
§ Field Oriented Data Formatter The Field Oriented Data Formatter allows user to flexibly divide scanned data by “Delimiter” or “Length.” To use with “Added Field” and “Transmission Sequence Arrangement” features, the user can implement “Insert,” “Delete,” “Replace,” “Re-organize” and other data editing capabilities beyond your imagination.
3-3
Page 20
Programming the Scanner
Application Example The bar code label is a 16-digit Code 39 that contains a 6-digit date code, a 6-digit serial number, and a 4-digit unit price (in that order). The scanner can do the following for you without software modification: §
Configuration Procedure § Select “Using 1 Rule.” § Set “Applied Bar Code” to “Code 39.” § Set “Valid ASCII Range” to “Numeric.” § Select “Using Match 1.”
Check the bar code to see if it is Code 39 or not. Reject any
§ Set “Matched Data “ to “99,” and set “Start Position” to “1.” codes that are not Code 39. §
§
Check the bar code content to see if it is numeric or not.
Set “Field Divided By” of F1 to “Fixed Length” for “2.”
Reject any codes that are not all numeric as invalid. §
Set “Field Divided By” of F2 to “Fixed Length” for “4.”
Check the first two digits to see if they match “99.” Reject any
Set “Field Divided By” of F3 to “Fixed Length” for “6.” codes that do not match.
Set “Field Divided By” of F4 to “Fixed Length” for “2”
§ Output each of the three fields followed by a “TAB.” §
Then Data Editor assigns the remaining 2 digits as “Last
The date code output should skip “99” and replaced it with
Field (LF)” automatically. Please note that if the code 39 bar
“AA.” code label is printed with “Check Digit,” the last field will have 3 digits.
§ The serial number output should be led with “S/N:.” §
§ The first 2 digits of unit price output should be skipped. §
Set “Original Field” to “Divide scanned data into 4 fields.”
Set ”Added Field” to “Insert 3 Added Fields.”
The output sequence should be unit price, date code, and
Set “AF1” (Added Field 1) to “AA.” serial number.
Set “AF2” to “S/N:.” Set “AF3” to “TAB (Hex 09).”
§ Actual Bar Code label : 9 9 1 0 2 5 1 2 3 4 5 6 9 8 7 6 §
§ Desired Output : 76[TAB]AA1025[TAB]S/N:123456[TAB] Please use HHP SET to configure the full-feature Data Editor, and follow the procedures listed below. 3-4
Set “Transmission Sequence” to “LF,” “AF3,” “AF1,” “F2,” “AF3,” “AF2,” “F3,” and “AF3.”
Page 21
Programming the Scanner
Bar Code Programming Menu
System Command The System Command is the highest level bar code command that directs the scanner to perform immediate operations, such as entering programming mode (PROGRAM), exiting programming mode (EXIT), listing system information (SYSLIST), recovering to factory preset configurations (M_DEFAULT), and so on. Please note that all system commands will take a few seconds to complete the operations. The user must wait for the completion beeps before scanning another bar code.
The bar code commands are specially designed Proprietary bar code labels that allow you to set the scanner’s internal programming parameters. There are System Command, Family Code and Option Code for programming purpose. Each programmable family and bar code command label is listed on the same page with major system commands. The detailed explanations and special programming flowchart are printed on facing or following pages. You can read the explanation and set the scanner concurrently.
Family Code The Family Code is scanned to select the user desired programming family. More than one hundred programming families have been provided to meet any specific requirements.
A supplemental bar code command menu incorporates the bar code command labels of System Command and Option Code. As you set the scanner, open the bar code command menu to find the option code page. You may scan the desired family code and option code to set scanner. If you want to change the programming family for multiple settings, you need only turn over the programming page to the find next desired programming family.
Option Code The Option Codes is a set of bar code commands represented by “0–9,” “A–F,” and finishing selection (FIN). For most settings, you must select at least one option code following the family code selection to set the desired parameter for the selected programming family.
3-5
Page 22
Programming the Scanner
Programming Procedures As you scan the bar code command to select the desired parameters, this information is stored in the scanner’s internal Flash Memory ASIC or non-volatile memory. If you turn off the unit, the Flash Memory ASIC or non-volatile memory retains all programmed settings.
3-6
Page 23
Programming the Scanner
Program & End
System List & Master Default Scan “PROGRAM”
Scan “SYSLIST” Scanner lists the product information and
Scanner enters programming mode, and inhibits all non-programming functions.
revision number to host via selected host interface, then issues the completion beeping (3 short beeps).
Scan “END”
Scan “M_DEFAULT”
Scanner exits programming mode, and stores all parameters in Flash Memory ASIC or non-volatile memory,
Scanner returns all programmable parameters to factory preset configurations, then issues the completion beeping (3 short beeps).
then issues the completion beeping (3 short beeps).
Please note that the scanner will take 3-4 seconds to store parameters in internal Flash Memory ASIC or non-volatile memory after you scan the “END.” Please do not turn off the power before the completion beeping. It may destroy all configured parameters.
3-7
Page 24
Programming the Scanner
Selection Flow Diagrams EXAMPLE 1
EXAMPLE 2
Scan “PROGRAM”
Scan One of Family Codes
Scan One of Option Codes
Scan “PROGRAM”
Enter programming mode.
Select one of desired
Scan programming families.
One of Family Codes
(1st) Scan Several Option Codes several option codes of
“Single” or “Multiple”
Yes
Repeat Selection programming families.
of desired parameters. 1. Select one or several option codes of desired scans selection.
(2nd) Scan One or Several Option Codes parameters. 2. If it’s necessary, scan
Finish cycling selection.
“FIN” to terminate
(If necessary)
option code selection.
Yes Want to select another
Repeat Selection
Want to select another programming family?
programming family?
No Scan
Select one of desired
Select several option codes
Cycling select one or desired parameters as
Scan “FIN” If indicated
Enter programming mode.
No Scan “END”
Exit programming mode.
“END”
3-8
Exit programming mode.
Page 25
Programming the Scanner
Host Interface Selection ♦ TERMINAL ID ♦ PROGRAM
END(Exit)
Family Code Selection Host Interface Selection
♦ US/EUROPEAN VERSION ♦
Parameter Selection Standard/TTL RS-232 serial interface
00
IBM PC/XT, 286/XT keyboard wedge interface (Full Size Din)
01
IBM PS/2, 25-30 series keyboard wedge interface (Mini Din)
02
IBM PC/AT, PS/1, PS/VP series keyboard wedge interface (Mini Din) u
03
PC/AT, PS/2 keyboard replacement interface (without external keyboard)
10
General Notebook PC keyboard wedge interface (PC/AT, PS/2 Compatibles)
03
General Notebook PC keyboard direct-link interface (without external keyboard)
14
APPLE ADB keyboard wedge interface
49
Standard TTL RS-232 serial wedge interface
50
Wand emulation interface
61 ®
Host Interface Selection
®
USB keyboard interface (for Microsoft Windows 98, 2000 and Apple iMac)
C4
DOS/V keyboard wedge interface*
A2
NEC PC-98xx keyboard wedge interface*
A3
IBM ThinkPad keyboard direct-link interface (without external keyboard)*
A6
♦ JAPANESE VERSION ♦ § u FACTORY DEFAULT § For Notebook computer user, we suggest that the user try ID=10 first, then ID=14. § USB keyboard interface is only supported by Windows 98, Windows 2000 or above and Apple iMac system. § *Supported by Japanese Version only.
Option Code
All other interfaces are supported by both the US/Eurpoean and Japanese units.
3-9
Page 26
Programming the Scanner
User Defined Code ID This section allows the user to define and program a Code ID that is different from the Code ID default. To specify a one-character Code ID, scan in the 2-digit hex value for that character. Then scan “END”. The hex value can be determined by referring to the HEX/ASCII Reference Table on page A-6. To specify a two-character Code ID, scan the 2-digit hex values for each of the desired characters. Then scan “END.” If you only want to assign a one-character Code ID for UPC-E or EAN-8, scan the two-digit hex code for the desired character. Then Scan “FIN” and “END” bar codes. Note : To transmit the Code ID, you have to enable Code ID transmission in page 3-12.
3-10
Page 27
Programming the Scanner
Symbology Programming ♦ User Defined Code ID ♦ PROGRAM
END(Exit)
Family Code Selection Symbol ID : 1 character
Symbol ID : 2 character
Parameter Selection
Option Code
Option Code
Code 128 (default=B)
00
Scan hex value (2 digits)
UCC/EAN-128 (default=C)
01
Scan hex value (2 digits)
UPC-A (default=A)
02
Scan hex value (2 digits)
EAN/JAN/CAN-13 (default=F)
03
Scan hex value (2 digits)
Codabar/NW-7 (default=D)
04
Scan hex value (2 digits)
Code 39/Code 32 (default=G)
05
Scan hex value (2 digits)
Code 93 (default=H)
06
Scan hex value (2 digits)
Standard/Industrial 2 of 5 (default=I)
07
Scan hex value (2 digits)
Interleaved 2 of 5 (default=J)
08
Scan hex value (2 digits)
Matrix 2 of 5 (default=K)
09
Scan hex value (2 digits)
China Postal Code (default=L)
10
Scan hex value (2 digits)
German Postal Code (default=M)
11
Scan hex value (2 digits)
IATA (default=O)
12
Scan hex value (2 digits)
Code 11 (default=P)
13
Scan hex value (2 digits)
MSI/Plessey (default=R)
14
Scan hex value (2 digits)
UK/Plessey (default=S)
15
Scan hex value (2 digits)
Telepen (default=T)
16
Scan hex value (2 digits)
UPC-E (default=E0)
00
Scan hex value (2 or 4 digits) [FIN]
EAN-8 (default=FF)
01
Scan hex value [2 or 4 digits] [FIN]
§ To determine the hex value for the “Character,” refer to the ASCII/HEX Table found in Appendix A.
3-11