Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 8

ValueTeam 3060 / 80, ImageTeam 3220 User's Guide, pages 10 to 18

Pages 10 to 18 of 71

The original document is the PDF (769 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP IT3220

Page 10

Getting Started

Outer Box Label

Outer Box Label

IMAGETEAM MID - RANGE LINEAR IMAGER , UNIVERSAL INTERFACE

Description

VALUETEAM 80mm BAR CODE SCANNER , UNIVERSAL INTERFACE

Description

P/N : 3220-12

Model Number

P/N : 3080B-12

Model Number

S/N : A1210001

Serial Number

S/N : A1220001

Serial Number

N344

N344

Made in Taiwan

Made in Taiwan

Product Label

Product Label N344

N344 Made in Taiwan

Made in Taiwan

P/N:3080B-12 S/N:A1220001

P/N:3220-12 S/N:A1210001

Complies with FCC Part 15 and Canadian ICES-003 Emission requirements. See User’s Manual for details

Complies with FCC Part 15 and Canadian ICES-003 Emission requirements. See User’s Manual for details

1-2

Page 11

Getting Started

To use the HHP SET with the IT3220, the user must have a serial adapter cable and a power supply. Please refer to Chapter 3 “Programming the Scanner” to understand all details of HHP SET. You will find HHP SET has totally changed the traditional ways of managing your bar code reading device.

The IT3220 and VT3060B/3080B models come with a main cable equipped with a RJ-45 phone plug, which can provide multiple host interface connections when combined with a host adapter cable. Please note that a separated cable adapter is needed to complete the cable connection for product installation.

HHP SET HHP SET is a unique software utility that has been designed to operate under Microsoft Windows 95/98, Windows NT , and Windows 2000, and provides the following functions: ™

®

®

®

®

§ User friendly on-screen configuration § Configuration download and upload § Program (Firmware) field upgrade § Check software revision § Full feature data editor

1-3

Page 12

Getting Started

1-4

Page 13

Terminal Interfaces

2. Terminal Interfaces

Keyboard Wedge Interface

The IT3220 and VT3060B/3080B scanners are easily configured to work with a variety of interfaces by installing the desired cable adapter and by programming the selected terminal interface. After identifying the communication interface you will use and obtaining the suitable interface adapter cable, you plug the RJ45 Phone Plug of the IT3220 or VT3060B/3080B main cable into the connector of the selected interface cable adapter. Please make sure the connector clicks into place securely.

The keyboard wedge interface allows data transmission from the scanner to the host through the existing keyboard port as traditional keyboard input.

3220 Main Cable

PC/AT, PS/2 Keyboard Wedge

For the keyboard wedge solution, the scanner must work with the existing keyboard concurrently. If you want to link the scanner to a computer keyboard port without a PC/AT or PS/2 keyboard, please select “Emulate External Keyboard.” This selection instructs the scanner to perform the power-on handshaking and routine reply between computer and keyboard.

Interface Cable Adapter

All scanners have been preset to the “IBM PC/AT, PS/2 Keyboard Wedge” interface. If you need to change the host interface, please refer to the “Host Interface Selection” described in Chapter 3 to find your desired interface. The following paragraphs provide the installation of the most popular host interfaces.

2-1

Page 14

Terminal Interfaces

Keyboard Wedge Installation

F PS/2 Keyboard Wedge Connection Plug the 5P DIN female connector of slave cable into the 5P DIN male connector of main cable of the scanner. Then connect the rest of the connectors to the computer keyboard port and PS/2 keyboard.

§ Turn off your computer system and unplug the keyboard. §

Plug the RJ45 phone plug of scanner’s main cable into the

F PC/AT Keyboard Wedge Connection

PC/AT or PS/2 cable converter. §

Plug the 6P Mini DIN male connector of slave cable into 6P Mini DIN female connector of main cable of the scanner. Then connect the rest of the connectors to the computer keyboard port and PC/AT keyboard.

Plug the male connector of the cable converter into the keyboard port of your computer.

§

Plug the male connector of keyboard into the female

RS-232 Serial Interface connector of the cable converter. §

Turn on your computer system. Open a text program, such as

RS-232 Serial interface is among one of the most popular applications of bar code scanners. Before connecting your scanner to the RS-232 communication port of host machine, please follow the procedures illustrated below.

Notepad or Microsoft Word and scan a bar code sample with the scanner and verify that correct data is displaying on the screen. Scanner Main Cable

To Computer Keyboard Port

Scanner Main Cable

To Computer Keyboard

To RS-232 Port

RS-232 Serial Interface Connection

PC/AT Keyboard Wedge Connection

2-2

Page 15

Terminal Interfaces

RS-232 Interface Installation

§ Scanning the RS-232 interface bar code above configures the scanner’s serial parameters to 9600 Baud, 8 data bits, no parity,

§ Verify the RS-232 port (COM1 or COM2) available on your and 1 stop bit, no handshaking.

computer system.

Please note that the RS-232 settings of the host system must

§ Plug the RJ45 phone plug of the main cable into the RS-232 match the scanner’s RS-232 settings.

cable adapter.

§ If you are in the Windows environment, you may use the ®

§ Plug the 9-pin or 25-pin D-sub connector of cable converter

“Hyper Terminal” to test.

into the desired serial port on your system.

Standard RS-232 Pinouts

§ Attach the power outlet plug of the optional AC power adapter

PIN-1: VCC (5V) PIN-2: TD PIN-3: RD PIN-4: NC PIN-5: GND PIN-6: NC PIN-7: CTS PIN-8: RTS PIN-9: VCC (5V)

to the side power jack of the D-sub connector. You will hear the power-on beep twice to signal that the scanner is ready for bar code reading. Scan the “RS-232 Serial Interface” bar code to configure the scanner to perform the RS-232 serial interface operation.

(-)

(+)

9 Pin D-sub RS-232 Female Connector PIN-2: RD PIN-3: TD PIN-4: CTS PIN-5: RTS PIN-6: NC PIN-7: GND PIN-16: VCC (5V) PIN-25: VCC (5V)

RS-232 Serial Interface

(-)

(+)

Pin 25 D-sub RS-232 Female Connector 2-3

Page 16

Terminal Interfaces

USB Keyboard Interface The USB interface is one of the common standard peripheral interfaces for today’s computer system working under Windows 98 and Windows 2000 or above.

§ Make sure your computer has a USB port and the operating

Scanning the following bar code will program for the USB interface.

§ Plug the RJ45 phone plug of the scanner main cable into the

® system is Windows® 98, Windows NT® 5.0, and Windows® 2000 or above.

®

USB keyboard cable converter. § Plug the 4-pin USB Type A connector into the desired USB port of your computer. You will hear the power-on beep twice to signal that the power-on routine of the scanner is completed. § Whenever the scanner’s USB interface scanner is connected to any computer system for the first time, a string of “USB Manufacturer ID Message” will be prompted to register the scanner into the operating system.

USB Keyboard Interface

FuzzyScan Main Cable

To Computer USB Port

§ Please scan the “USB Keyboard Interface” bar code to configure the scanner into USB keyboard interface mode. The scanner is now ready to use. USB Keyboard Interface Connection

2-4

Page 17

Programming the Scanner

3. Programming the Scanner

§ Check Software Revision

§ Full-featured Data Editor

There are two ways to configure the IT3220 or the VT3060/3080 – either using HHP SET or the programming bar codes in this user’s guide. ™

These beneficial features are accomplished through outstanding software design and on-board advanced flash memory ASIC.

Via HHP SET HHP SET is a unique software utility designed to operate under Microsoft Windows 95, 98, NT or above. HHP SET offers a convenient and user-friendly way to program the scanner. ®

HHP SET at A Glance

®

Via Bar Code Programming Menu The bar code programming menu is designed for field programming convenience. Before you use the bar code programming menu, please take the time to review the command structure and various programming procedures.

HHP SET Main Screen

Host Interface Screen

Data Editor Screen

Bar Code Screen

HHP SET The innovative HHP SET utility provides the following features: § User Friendly On-screen Configuration § Configuration Download and Upload § Program (Firmware) Field Upgrade (Flash)

3-1

Page 18

Programming the Scanner

Configuration Download and Upload You can retrieve (Upload) the configurations from the scanner or send (Download) new configurations to the scanner. Of course, duplicating preset configurations is as easy as 1-2-3.

While you are asking HHP SET to do the “Download,” “Upload,” and “Diagnostic” with the scanner, HHP SET will ask you to use the scanner to scan the Host Link Command for initial handshaking with HHP SET and then perform your desired action.

Program Field Upgrade Internal program (firmware) change or modification is only one step away via the Field Upgrade feature of the utility.

HHP SET Host Link

Check Software Revision You can use the Check Revision feature to check the software revision number, to verify if the communication between your scanner and host system is good, and to check the operation of the beeper and the indicator light.

Software Installation You may download HHP SET from the IT3220 or VT3060B/3080B product pages from our web site at www.handheld.com. On-screen Configuration Compared with the traditional configurations done via bar code menus, HHP SET provides a GUI interface that allows the user to easily configure the scanner. The Save feature allows the configuration to be saved as a file. The Convert feature consolidates all programmable parameters for a certain application and prints the configuration list.

3-2