The text of a manual · part 2 of 8
ValueTeam 3060 / 80, ImageTeam 3220 User's Guide, pages 10 to 18
Pages 10 to 18 of 71
The original document is the PDF (769 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP IT3220
Page 10
Getting Started
Outer Box Label
Outer Box Label
IMAGETEAM MID - RANGE LINEAR IMAGER , UNIVERSAL INTERFACE
Description
VALUETEAM 80mm BAR CODE SCANNER , UNIVERSAL INTERFACE
Description
P/N : 3220-12
Model Number
P/N : 3080B-12
Model Number
S/N : A1210001
Serial Number
S/N : A1220001
Serial Number
N344
N344
Made in Taiwan
Made in Taiwan
Product Label
Product Label N344
N344 Made in Taiwan
Made in Taiwan
P/N:3080B-12 S/N:A1220001
P/N:3220-12 S/N:A1210001
Complies with FCC Part 15 and Canadian ICES-003 Emission requirements. See User’s Manual for details
Complies with FCC Part 15 and Canadian ICES-003 Emission requirements. See User’s Manual for details
1-2
Page 11
Getting Started
To use the HHP SET with the IT3220, the user must have a serial adapter cable and a power supply. Please refer to Chapter 3 “Programming the Scanner” to understand all details of HHP SET. You will find HHP SET has totally changed the traditional ways of managing your bar code reading device.
The IT3220 and VT3060B/3080B models come with a main cable equipped with a RJ-45 phone plug, which can provide multiple host interface connections when combined with a host adapter cable. Please note that a separated cable adapter is needed to complete the cable connection for product installation.
HHP SET HHP SET is a unique software utility that has been designed to operate under Microsoft Windows 95/98, Windows NT , and Windows 2000, and provides the following functions: ™
®
®
®
®
§ User friendly on-screen configuration § Configuration download and upload § Program (Firmware) field upgrade § Check software revision § Full feature data editor
1-3
Page 12
Getting Started
1-4
Page 13
Terminal Interfaces
2. Terminal Interfaces
Keyboard Wedge Interface
The IT3220 and VT3060B/3080B scanners are easily configured to work with a variety of interfaces by installing the desired cable adapter and by programming the selected terminal interface. After identifying the communication interface you will use and obtaining the suitable interface adapter cable, you plug the RJ45 Phone Plug of the IT3220 or VT3060B/3080B main cable into the connector of the selected interface cable adapter. Please make sure the connector clicks into place securely.
The keyboard wedge interface allows data transmission from the scanner to the host through the existing keyboard port as traditional keyboard input.
3220 Main Cable
PC/AT, PS/2 Keyboard Wedge
For the keyboard wedge solution, the scanner must work with the existing keyboard concurrently. If you want to link the scanner to a computer keyboard port without a PC/AT or PS/2 keyboard, please select “Emulate External Keyboard.” This selection instructs the scanner to perform the power-on handshaking and routine reply between computer and keyboard.
Interface Cable Adapter
All scanners have been preset to the “IBM PC/AT, PS/2 Keyboard Wedge” interface. If you need to change the host interface, please refer to the “Host Interface Selection” described in Chapter 3 to find your desired interface. The following paragraphs provide the installation of the most popular host interfaces.
2-1
Page 14
Terminal Interfaces
Keyboard Wedge Installation
F PS/2 Keyboard Wedge Connection Plug the 5P DIN female connector of slave cable into the 5P DIN male connector of main cable of the scanner. Then connect the rest of the connectors to the computer keyboard port and PS/2 keyboard.
§ Turn off your computer system and unplug the keyboard. §
Plug the RJ45 phone plug of scanner’s main cable into the
F PC/AT Keyboard Wedge Connection
PC/AT or PS/2 cable converter. §
Plug the 6P Mini DIN male connector of slave cable into 6P Mini DIN female connector of main cable of the scanner. Then connect the rest of the connectors to the computer keyboard port and PC/AT keyboard.
Plug the male connector of the cable converter into the keyboard port of your computer.
§
Plug the male connector of keyboard into the female
RS-232 Serial Interface connector of the cable converter. §
Turn on your computer system. Open a text program, such as
RS-232 Serial interface is among one of the most popular applications of bar code scanners. Before connecting your scanner to the RS-232 communication port of host machine, please follow the procedures illustrated below.
Notepad or Microsoft Word and scan a bar code sample with the scanner and verify that correct data is displaying on the screen. Scanner Main Cable
To Computer Keyboard Port
Scanner Main Cable
To Computer Keyboard
To RS-232 Port
RS-232 Serial Interface Connection
PC/AT Keyboard Wedge Connection
2-2
Page 15
Terminal Interfaces
RS-232 Interface Installation
§ Scanning the RS-232 interface bar code above configures the scanner’s serial parameters to 9600 Baud, 8 data bits, no parity,
§ Verify the RS-232 port (COM1 or COM2) available on your and 1 stop bit, no handshaking.
computer system.
Please note that the RS-232 settings of the host system must
§ Plug the RJ45 phone plug of the main cable into the RS-232 match the scanner’s RS-232 settings.
cable adapter.
§ If you are in the Windows environment, you may use the ®
§ Plug the 9-pin or 25-pin D-sub connector of cable converter
“Hyper Terminal” to test.
into the desired serial port on your system.
Standard RS-232 Pinouts
§ Attach the power outlet plug of the optional AC power adapter
PIN-1: VCC (5V) PIN-2: TD PIN-3: RD PIN-4: NC PIN-5: GND PIN-6: NC PIN-7: CTS PIN-8: RTS PIN-9: VCC (5V)
to the side power jack of the D-sub connector. You will hear the power-on beep twice to signal that the scanner is ready for bar code reading. Scan the “RS-232 Serial Interface” bar code to configure the scanner to perform the RS-232 serial interface operation.
(-)
(+)
9 Pin D-sub RS-232 Female Connector PIN-2: RD PIN-3: TD PIN-4: CTS PIN-5: RTS PIN-6: NC PIN-7: GND PIN-16: VCC (5V) PIN-25: VCC (5V)
RS-232 Serial Interface
(-)
(+)
Pin 25 D-sub RS-232 Female Connector 2-3
Page 16
Terminal Interfaces
USB Keyboard Interface The USB interface is one of the common standard peripheral interfaces for today’s computer system working under Windows 98 and Windows 2000 or above.
§ Make sure your computer has a USB port and the operating
Scanning the following bar code will program for the USB interface.
§ Plug the RJ45 phone plug of the scanner main cable into the
® system is Windows® 98, Windows NT® 5.0, and Windows® 2000 or above.
®
USB keyboard cable converter. § Plug the 4-pin USB Type A connector into the desired USB port of your computer. You will hear the power-on beep twice to signal that the power-on routine of the scanner is completed. § Whenever the scanner’s USB interface scanner is connected to any computer system for the first time, a string of “USB Manufacturer ID Message” will be prompted to register the scanner into the operating system.
USB Keyboard Interface
FuzzyScan Main Cable
To Computer USB Port
§ Please scan the “USB Keyboard Interface” bar code to configure the scanner into USB keyboard interface mode. The scanner is now ready to use. USB Keyboard Interface Connection
2-4
Page 17
Programming the Scanner
3. Programming the Scanner
§ Check Software Revision
§ Full-featured Data Editor
There are two ways to configure the IT3220 or the VT3060/3080 – either using HHP SET or the programming bar codes in this user’s guide. ™
These beneficial features are accomplished through outstanding software design and on-board advanced flash memory ASIC.
Via HHP SET HHP SET is a unique software utility designed to operate under Microsoft Windows 95, 98, NT or above. HHP SET offers a convenient and user-friendly way to program the scanner. ®
HHP SET at A Glance
®
Via Bar Code Programming Menu The bar code programming menu is designed for field programming convenience. Before you use the bar code programming menu, please take the time to review the command structure and various programming procedures.
HHP SET Main Screen
Host Interface Screen
Data Editor Screen
Bar Code Screen
HHP SET The innovative HHP SET utility provides the following features: § User Friendly On-screen Configuration § Configuration Download and Upload § Program (Firmware) Field Upgrade (Flash)
3-1
Page 18
Programming the Scanner
Configuration Download and Upload You can retrieve (Upload) the configurations from the scanner or send (Download) new configurations to the scanner. Of course, duplicating preset configurations is as easy as 1-2-3.
While you are asking HHP SET to do the “Download,” “Upload,” and “Diagnostic” with the scanner, HHP SET will ask you to use the scanner to scan the Host Link Command for initial handshaking with HHP SET and then perform your desired action.
Program Field Upgrade Internal program (firmware) change or modification is only one step away via the Field Upgrade feature of the utility.
HHP SET Host Link
Check Software Revision You can use the Check Revision feature to check the software revision number, to verify if the communication between your scanner and host system is good, and to check the operation of the beeper and the indicator light.
Software Installation You may download HHP SET from the IT3220 or VT3060B/3080B product pages from our web site at www.handheld.com. On-screen Configuration Compared with the traditional configurations done via bar code menus, HHP SET provides a GUI interface that allows the user to easily configure the scanner. The Save feature allows the configuration to be saved as a file. The Convert feature consolidates all programmable parameters for a certain application and prints the configuration list.
3-2