Festo Software Tools: Statement list and Ladder diagram for SF 3, FST 200 Manual, pages 441 to 450
Pages 441 to 450 of 496
The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Festo FPC-202
Page 441
FST 200
Appendix C
DOS error. Invalid filename A filename with invalid characters has been entered in a block read or save operation.
DOS error. Too many files opened You have opened too many files by comparison with the "Files =" statement in your CONFIG. SYS. Increase the entry in the "Files =" statement in your CONFIG.SYS.
Double STEP statement Statement list programming error: Two step statements have been entered consecutively.
E
Empty statement You have not made an instruction specific when programming the statement list, i.e. IF, THEN or ELSE are entered in your program without a specifying conditional or execution instruction.
EPROM data corrupted Errors have been detected in a check on the data in the EPROM. Start a new programming attempt. Delete the data in the EPROM or replace it if the error occurs again. Try once again.
EPROM not empty or not present The EPROM inserted in the EPROM programmer is not deleted, or no EPROM is present in the programmer.
Error changing to the local directory This error occurs when you are working with floppy disks. The path must be changed when creating the project path. This message will appear if it is then not possible to change to the local directory (disk) because you have opened the floppy drive.
9610a
C-11
Page 442
FST 200
Appendix C
Error 21: Statement too long Code generator error message: The internal memory in the code generator is not large enough to process an STL statement. A long statement must be subdivided into a number of statements.
Error in receiver module of serial interface The serial interface has been set up with an incorrect interface driver or the FPC baud rate has been set incorrectly.
Error occurred At the end of a translation procedure, the system has determined that a syntax, semantic or other error (e.g. corrupted ladder diagram file) has occurred. The error list gives more precise information regarding the errors that have occurred.
Error opening file XXX It is probable that the disk is write-protected or the file is corrupted.
Error opening the error list The error list file cannot be found.
Execution module is empty Translation of an LDR program has established that the execution module of a current path consists only of an empty arithmetic and logic box.
F Faulty program load Error on loading a single program.
Faulty program read Error on reading a single program (BASIC only).
Faulty program syntax The translated program has a syntax error.
C-12
9610a
Page 443
FST 200
Appendix C
Field bus configuration read error An error has occurred when reading the configuration file created for the field bus operand.
Field bus operand not configured The field bus operand has not yet been entered in the configuration file for field bus operands.
File C:\CONFIG.SYS is write-protected and cannot be edited. The program has detected that it is not possible to install the software, as file C:\CONFIG.SYS cannot be edited.
File error. DOS error no. XXX The error number gives further information. For instance, you may have removed the disk from the floppy drive prematurely.
File error. File has become too large At the start of the editing procedure, the system has determined that there is too little space available on the drive for further data.
File error. File too large to edit At the start of the editing procedure, the system has determined that there is too little space available on the drive for further information.
File extension may not be modified. The default file extension (eg. .STL or .LDR) may not be edited when a text block is saved.
File not found. The file required for the translation of source programs into machine code cannot be found on the hard disk/floppy disk specified.
File read error The file specified cannot be found or is corrupted.
9610a
C-13
Page 444
FST 200
Appendix C
File save error The configuration cannot be saved. Causes: Hard disk is full, drive is open, \LIB directory has not been created.
Files may only be selected from the filenames displayed. You are attempting to import a file that is not displayed in the list. Select one of the files displayed.
File write error (EOF) An error was discovered when writing to the PC hard disk. The most frequent cause of error is a full hard disk (insufficient storage capacity).
File XXXTSYS.ERR not found This error may occur when the Show Errors function (DF or Error Status F6) is selected in Online Mode. The system has discovered that file XXXTSYS.ERR does not exist. This program is used for displaying errors from the controller and must be located in the FST directory.
First rung cannot be deleted. At least one rung must exist before you can program in the ladder diagram. You cannot delete the first rung.
FPC connection cannot be established Please check the connection to the controller (cable) and the baud rate setting on all FPCs which do not have automatic baud rate setting.
FPC type unknown, not supported or defective transmission This error message appears if an incorrect test system (FPC Online Mode) is used for the controller. This error also occurs if errors in transmission happen during the log-on phase.
C-14
9610a
Page 445
FST 200
Appendix C
FST program not available The FST utility program shown is not available.
Function keys file not found Filename: XXX.KEY FST file XXX.KEY is missing; either it does not exist or it is corrupted.
Function module output not connected or incorrectly connected Programming in the function chart: Check whether the output from the function module is connected and whether the wires are correct.
9610a
C-15
Page 446
FST 200
Appendix C
G GOTO incorrectly connected Programming in the function chart: Check whether the GOTO symbol is connected and whether the wires are correct.
GOTO instruction already exists. Programming in the ladder diagram: You are attempting to assign a goto instruction which already exists.
GOTO instruction without GOTO target Ladder diagram: A GOTO statement has been entered in the execution part of a rung without specifying a GOTO target.
Goto label missing The conditional part contains the symbol for a GOTO target, the GOTO label (identifier) itself has not, however, been entered.
H Hard disk is full. Installation will be aborted. The FST software install routine has determined that there is not sufficient space available on your hard disk.
C-16
9610a
Page 447
FST 200
Appendix C
I Identical project name is not permitted. You have entered an existing project name during the Backup - Rename project function.
IF, ELSE or STEP expected Statement list programming error: A statement concluded with a THEN part can only be followed by: - an ELSE - a new statement or a new step
IF or STEP expected Statement list programming error: A completed statement must be followed by a new statement or a new step.
Illegal CI command range The FPC range identifier is incorrect. Permitted range identifiers are: P, B, C, F, K.
Illegal CI range parameter The program or module number is outside the permitted values (see CI description).
range of
Illegal CI range type The program to be loaded is type A, B, C, or I. The program name and the number must be retained for importing.
Illegal computer interface specified The serial interface is not COM1 or COM2.
Illegal default value The default value for the counter is not within the permitted range of values.
Illegal default value for the counter Maximum counter default value has been exceeded. 9610a
C-17
Page 448
FST 200
Appendix C
Illegal default value for the timer Timer default value too great (maximum 655.35 s).
Illegal file extension specified Permissible file extensions are ’FST’ and ’CFG’. ’OBJ’ is assumed as the file extension if no other file extension is specified.
Illegal library type The legal library types are ’A’, ’B’, ’F’ and ’K’.
Illegal / missing GOTO target The label to which your program is intended to jump does not exist.
Illegal module number Assignment of module numbers is controller-dependent. Module numbers for SF 3, FPC 202 c: CFM 0 - 255 SF 3: CMP 0 - 15, FPC 202 C: CMP 0 - 7
Illegal operand after TO or SHIFT You have used an invalid absolute operand after TO and SHIFT. Refer to the syntax diagrams in Appendix A of this manual for statement list programming.
Illegal operation, please reenter You are attempting to apply an operation to an operand which is not permitted with this operand.
Illegal parameter This error occurs when the length of the parameter is invalid. This error message will also appear if a string parameter has not been closed correctly.
Illegal project name You have used illegal characters when assigning the project name (refer to DOS manual).
Illegal program length The program is either longer than 32687 bytes or smaller than 8 bytes.
C-18
9610a
Page 449
FST 200
Appendix C
Illegal program type You are attempting to edit a program that was written in a programming language not suitable for the editor. It is not possible, for instance, to edit a statement list program with the BASIC Editor.
Illegal SF-3-LIB library type The library identifier is not ’L’ or ’l’.
Illegal symbolic operand Programming in the ladder diagram: A symbolic operand may not be an absolute operand and may only begin with an underscore (_ ) or a letter.
Illegal target for block operation. Programming in the ladder diagram: You may not copy or move to a marked block.
Illegal value Illegal values for the timer or counter, for instance.
Inconsistent CI range The import program has imported an FPC file or an FPC program, the file type or program type of which does not match the corresponding parameters in the file or program header.
Inconsistent CI range parameter The import program has imported an FPC file or an FPC program, the file name or program number of which does not match the corresponding parameters in the file or program header.
Incorrect diskette number # inserted. You have inserted the wrong disk during the FST software installation routine.
Incorrect number of arguments The communications program has not received all the arguments required to load the controller. 9610a
C-19
Page 450
FST 200
Appendix C
Incorrect numerical value. Valid range of values: xxx.yyy Link module: The valid range of values was exceeded when the numbers were entered.
Incorrect numerical value. Valid range of values: The valid range of values was exceeded when the numbers were entered.
Incorrect or unspecified FPC -CCU no. The FPC CCU numbers are dependent on the controller used. The permissible CCU numbers for the 404 are, for instance, 0, 1, 2, 3, 4 and 5.
Incorrect or unspecified FPC controller type Permissible FPC controller types are 1 := FPC101, 2 := FPC202, 3 := FPC202C, 4 := FPC404 and 5 := FPC405. This error message is also generated if, for example, an FPC101 program is to be loaded into an FPC404. This error occurs if the wrong FPC controller is connected to the serial interface.
Incorrect runtime library, please translate again The runtime library supplied with this software version no longer matches the existing version of the OBJ files.
Incorrect statement sequence Statement list programming error: You have entered two THEN statements consecutively or a THEN statement immediately after an ELSE statement.
Incorrect statement start Statement list programming error: You are starting a statement with an invalid instruction.