Page 451

FST 200

Appendix C

Incorrect time specification The time specification for the timer is incorrect. Enter a number with no more than two places after the decimal and a maximum value of 655.35 seconds. Remember to enter the letter s for seconds.

Insufficient RAM bytes: There is not sufficient memory capacity available to start the FST software. The message shows how much more memory capacity is required in bytes.

Invalid absolute operand Operations in the ladder diagram have been assigned invalid absolute operands, eg. one-bit operand instead of multi-bit operand and vice versa.

Invalid absolute operand for .... ... stands for contact, coil, timer... Operations in the ladder diagram have been assigned invalid absolute operands, eg. one-bit operand instead of multi-bit operand and vice versa.

Invalid input, help on [F9] The input is invalid. Please press F9 for help.

Invalid input, help on [F9] You are attempting to provide impermissible input in the configuration of the software.

Invalid operand Programming in the statement list: The operand is not compatible with the operation. Refer to Appendix A1 Programming in the ladder diagram: Illegal NOP operand is only possible in conjunction with contacts.

Invalid operation You are attempting to apply an operation to an operand which is not permitted with this operand.

9610a

C-21

Page 452

FST 200

Appendix C

Invalid operation in arithmetic/logic box You are attempting to enter commands which are not permitted in the arithmetic/logic box, such as STEP, IF, THEN....PW, INC, DEC, CMP, CFM.

Invalid operator You are attempting to carry out a logical operation on an operand with an invalid operator. For instance, you are attempting to work with one-bit operands in the arithmetic/logic box. This is not permitted.

Invalid symbolic operand The operand you are attempting to enter may not be a hardware operand.

K K0...K255 expected You are attempting to manipulate an operand other than a constant in a constant operation.

L Ladder diagram file not yet translated. You wish to display states for a ladder diagram program (status display), although this program has not yet been translated into machine code or has not yet been loaded into the FPC. Please first load the program required to the controller.

Ladder diagram is empty. This message only appears in the event of a serious disk error. No data can be read.

LDR File not found. When attempting to import a ladder diagram, the system has determined that the file is corrupted or missing.

Last text will be overwritten. (Overflow) Insert anyway? You are attempting to insert a text although no more space is available. If you carry on and insert the text required, the last text displayed will be deleted.

C-22

9610a

Page 453

FST 200

Appendix C

Latest modifications will not be accepted You have made modifications to your program and wish to save them. However, there is not sufficient hard disk/floppy disk capacity available. This means that the most recent modifications cannot be accepted. Save the modified program on a hard disk/floppy disk that has sufficient space available.

LDR file will be saved to prevent loss. You have edited a very large number of rungs. The current status of the file will be saved to prevent data losses.

LIB path not present The \LIB directory does not exist in the project path. Create the relevant subdirectory.

Library checksum error A transmission error has occurred during loading of a library. Please repeat loading process. If the error occurs on several occasions, the library file is probably corrupted.

Linking impossible You have selected an incorrect file for importing.

Load corrupted from entry xxx An error has occurred during project loading. The number is counted from the top selected program in the program picklist (marked with an asterisk).

LOAD expected A multi-bit instruction in the arithmetic/logic box must begin with LOAD.

LOAD TO not permitted Only multi-bit operands that may be written to may be used at this point in the arithmetic/logic box, not C and IW.

9610a

C-23

Page 454

FST 200

Appendix C

M MAK file not installed This error message is issued if the XXX.MAK file has not been installed. Perhaps you are trying to work with the display editor, although this has not yet been provided for the controller type you are using.

MAK file not found This message appears when the file xxx.MAK is not found in the \LIB directory. This file is possibly corrupted, or you may have deleted it.

Maximum of 255 GOTO instructions permitted. A maximum of 255 GOTO instructions are permitted in a ladder diagram program (cf statement list program with 255 steps).

Maximum of 255 steps permitted A maximum of 255 steps are permitted in a statement list program (cf ladder diagram program with 255 GOTO instruction).

Memory error. Not enough free RAM A text block read routine has determined that there is not sufficient RAM for this operation. Have you loaded memory-resident programs?

Memory-resident program loaded. Please restart DOS You have loaded a memory-resident program in the FST environment. Do a soft or hard reset and call up FST again.

Missing comparator Statement list programming error: The second operator is missing from a multi-bit comparison.

Module library not found. File XXXBST.BIB is missing or corrupted.

Multi-bit operand expected Programming in the statement list: A one-bit operand may not follow a multi-bit operation.

C-24

9610a

Page 455

FST 200

Appendix C

Multiple GOTO label definition A GOTO label has been used in more than one rung.

Multiple step label definition : xxx You may only define a step label once. Check your program.

Multiple symbolic operand definition You are attempting to define a new symbolic identifier, but this has already been entered in full in the local or global allocation listing. The symbolic operand consequently has no uniquely assigned operands.

N Network output has no operand Programming in the function chart: An operand must be entered for each network output.

No coil may be deleted here. Programming in the ladder diagram: There must always be at least one coil or execution box in each current path.

No connection to the LDR. You are attempting to work in KOP Online Mode although - The connection to the controller is interrupted - The controller is switched off - An incorrect cable has been used - The controller or the interface is defective.

No data available or not translated The file for burning the EPROM must first be exported.

No display files found This error message is displayed in all functions (except for editing) if no display files are available when the function is selected.

No EPROM can be created for this display This error message is issued when the Burn EPROM function has been selected, but the current display type of the file selected does not permit EPROM operations.

9610a

C-25

Page 456

FST 200

Appendix C

No files in the project In the Project Backup routine you are attempting to backup or retrieve a project, although the project selected contains no files.

No files to rename in the project The Project Backup Rename function has determined that the project selected contains no files (programs).

No further boxes may be created as only five boxes are permitted per rung. For programing in the ladder diagram.

No further rungs are permitted. A maximum of 2000 rungs may be edited per LDR file.

No LDR file found in the library No ladder diagram files were found in the LIB project directory.

No more space for further columns. Ladder diagram programming: A maximum of 12 contacts may be connected in series.

No more statements possible after single execution part Statement list programming error: Only one execution part has been entered in a program. No further statement may be added after this in the same program.

No operator/operand or illegal operator/operand in logical operation You are attempting to associate an operand with an operator (or vice versa) in an operation where this is not permitted.

No program module can be created for this display You have selected the Create module function, but the current display type of the file selected does not permit the creation of modules.

C-26

9610a

Page 457

FST 200

Appendix C

No project found You are attempting to read a project from the floppy disk/hard disk during project backup, although no project is present.

No project found - please create it The program import routine requires that project directories and at least one project exist.

No projects found. The Project Backup Read function has determined that there are no projects to be read from the floppy disk/hard disk.

Not enough disk space available There is still not enough disk space available, even when the BAK file (backup copy) has been deleted.

Not enough disk space - BAK file will be deleted There is not enough disk space available for the file operations and/or write instructions to be executed. The BAK file (backup copy) of the file (in statement list, BASIC or ladder diagram) will be deleted.

Not enough free RAM The internal translator cannot be called, as there is insufficient RAM available for it. The internal syntax test may also be called if there is approximately 510 kB free RAM before the FST software is called.

Not enough free RAM. The line range specified will not be fully renumbered. Programming in BASIC: Renumbering of the line range specified will be cancelled as there is not enough memory available.

Not enough free RAM to read all directory entries. Not enough memory available to display all directory entries when reading and saving text blocks.

9610a

C-27

Page 458

FST 200

Appendix C

Not enough RAM available for the block operation. An error has occurred during a copy, move, delete or read block operation.

Not enough RAM. Program abort Link module: There is not enough free RAM available to link a module.

Not enough space for further parallel rung. Programming in the ladder diagram: A maximum of 10 contacts only may be used in parallel.

No valid FST identifier found on the disk. The FST identifier, which is held on the disk and is required for software installation, is not in order or there is more than one identifier.

Number of parameters is not correct. Error message from the allocation list: Hardware operand is not unique. No parameter will be generated or accepted automatically. You must enter the parameters in full

Numerical value expected Link module: Only digits are permitted here.

C-28

9610a

Page 459

FST 200

Appendix C

O Object file creation error. Program abort Link module: There is not sufficient capacity to create the object file and the program is aborted. Free up capacity on your hard disk and try again.

One-bit expression in brackets expected Statement list programming error: A one-bit expression must be entered in the nesting level specified.

One-bit operand expected Programming in the statement list: A multi-bit operand may not follow a one-bit operation.

Only multi-bit operands are allowed in arithmetics Programming in the statement list: You are attempting to calculate with one-bit operands, although this is only permitted with multi-bit operands.

Only values between 0 and 255 permitted Module numbers are only permitted from 0-255. You have entered an illegal value.

Operand does not exist You are attempting to find an operand which has not been entered in the allocation listing.

Operand for ... missing The ladder diagram operation is incomplete. The identifier is missing. ...stands for contact, coil, timer...= operations possible in ladder diagram.

Operand missing The ladder diagram operation is incomplete. The contact, coil etc has no operand.

9610a

C-29

Page 460

FST 200

Appendix C

Operand missing from allocation listing This message occurs in ladder diagram, function chart and in the arithmetic/logic box. It refers to the absence of a hardware operand.

Operand xxx not permitted in statement list. Incorrect operand definition. e.g.: FI. This operand definition would be permitted in a ladder diagram, but not in a statement list.

P Parallel coils may only be created before the GOTO command. This error message occurs during ladder diagram programming.

Parallel rung contains no contact You have set up a parallel rung without inserting a condition symbol.

Parallel rung is not yet empty. This error message occurs during ladder diagram programming.

Parallel rung results in invalid structure. This error message occurs during ladder diagram programming.

Parenthesized expression not closed This error occurs if the number of open brackets before a TO command is greater or smaller than the number of closing brackets.

PC-DOS utility program COMMAND.COM not found. The shell requires the COMMAND.COM or COMMAND.EXE file. Please copy this file into the FST directory.

Place pointer on a tab position The pointer P must be placed on the tab position to be deleted when deleting tab settings!

C-30