The text of a manual · part 44 of 50
Festo Software Tools: Statement list and Ladder diagram for SF 3, FST 200 Manual, pages 431 to 440
Pages 431 to 440 of 496
The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Festo FPC-202
Page 431
FST 200
Appendix C
Appendix C C.1
Definition of terms The various sections of this manual frequently make use of terms which are product-specific and therefore not always widely known. Some of these terms are explained in the glossary below. - Arithmetic Overflow: Memory overflow in an arithmetic operation. The result of the arithmetic operation exceeds memory capacity.
- Baud rate: Transmission rate in data transfer between communicating systems.
- Compiled program: A source program that was prepared in a higher level programming language and has been translated into machine language. Compiled programs are executed much more quickly than interpreted programs, but they require more memory.
- Configuration: This is the routine for setting-up a system to agreed parameters. Data traffic can suffer interference if a number of connected devices are set up differently.
- Documentation: The FST software takes documentation to mean a printout of control programs containing all program modules, annotated with explanatory text, date, programmer, version number and many other items.
9610a
C-1
Page 432
FST 200
Appendix C
- Edge: An edge occurs when a signal state changes. A positive or rising edge occurs when the signal changes from state 0 to state 1. In the reverse case this is known as a negative or falling edge.
- Edge detection: Edge detection refers to the detection of a signal state change. Each processing cycle checks whether the signal state has changed since the previous pass.
- Editor: The Editor is the background program you use to create control programs, for instance. An Editor provides you with the necessary tools and is designed to fulfill its task precisely. An Editor with FST always includes a syntax test which checks the program entered for incorrect or invalid input.
- EEPROM An electrically erasable and interference-proofed program memory. This can be written and erased with the FST 200 software.
- Field bus: Serial bus system that connects spatially remote parts of a system or production process for the purposes of information exchange. Sensors, actuators and control units with varying degrees of complexity can be attached to the central stations of this process.
C-2
9610a
Page 433
FST 200
Appendix C
- Handshake (software): This is a check routine which takes place during data transmission. A stop signal (DC1) is sent and transmission is interrupted if the buffer of the receiving device is full. Once the receiving device’s buffer is empty again, another DC1 is sent as a start signal and transmission continues from the point of interruption.
- Hardware: This refers to the equipment and all the components belonging to it which, connected together make up a "dead" unit. The hardware does not become "alive" until the appropriate software is loaded.
- Installation: This is the name for the specified manner of correctly copying the FST software onto a hard disk.
- Multitasking: Ability of a computer or control system to process a number of programs or processes (tasks) in parallel or quasi parallel.
- Online Mode A mode of operation in which some functions or controller executions are displayed directly on the screen. It is possible to manipulate individual operand values.
9610a
C-3
Page 434
FST 200
Appendix C
- Processor: Integrated circuit which executes the instructions of a program step by step. - Program: For the purposes of the FST software, a program is a single control task. A number of programs can go together to make up a project.
- Project: For the purposes of the FST software, a project is a collection of a number of programs and program versions with documentation.
- RAM: (Random Access Memory) A semiconductor memory which can accommodate control programs, for instance. If there is no battery backup, the entire contents of memory will be lost when the supply voltage is switched off.
- Shift Overflow: Overflow in a Shift Operation (SHL, SHR). The bit shifted out by these operations is stored in the private flag FI7.
- Software: In general, a program which tells the hardware what it has to do under what conditions.
- Syntax: Syntax refers to the correct way of spelling and laying out program instructions.
- Window: A window is a delimited area of the screen in which special information or messages are displayed.
C-4
9610a
Page 435
FST 200
C.2
Appendix C
Text editor command set The text editor commands can be accessed through the function keys or cursor keys, and also by using key combinations with the CRTL key (see section 2.5). Send these CRTL sequences by holding down the Control key and pressing the appropriate character key. Simple CRTL commands CRTL-A CRTL-C CRTL-D CRTL-E CRTL-F CRTL-G CRTL-H CRTL-I CRTL-J CRTL-L CRTL-N CRTL-R CRTL-S CRTL-V CRTL-W CRTL-X CRTL-Y CRTL-Z
Jump to start of word on left Next page Cursor one position to right Cursor one line up Jump to start of next word Delete character Delete character to left of cursor position Same as tab Explanations of this text editor Repeat text search Insert line before current line Previous page Cursor one position to left Insert mode On/Off Move screen content down Cursor to next line Delete current line Scroll screen content up
Extended CRTL-K commands CRTL-KB CRTL-KC CRTL-KD CRTL-KF CRTL-KH CRTL-KK CRTL-KQ CRTL-KR Ctrl-KS Ctrl-KV Ctrl-KW Ctrl-KY 9610a
Mark start of block Copy block Save and close editor File commands menu Show block On/Off Mark end of block Cancel edit: Retrieve block Save file and resume Move block Save block Delete block
C-5
Page 436
FST 200
Appendix C
Extended CRTL-Q commands CRTL-QA CRTL-QB CRTL-QC CRTL-QD CRTL-QE CRTL-QF CRTL-QG CRTL-QI CRTL-QJ Ctrl-QK Ctrl-QL Ctrl-QR Ctrl-QS Ctrl-QX Ctrl-QY
Find and replace text Jump to start of block Jump to end of text Jump to end of line Jump to first screen Find text Delete to start of line Engage On/Off Jump to line no.xx Jump to end of block Restore line Jump to start of text Jump to start of line Jump to last line on screen Delete to end of line
Extended CRTL-O commands CRTL-OC CRTL-OE CRTL-OI CRTL-ON Ctrl-OT Ctrl-OV
C-6
Toggle cursor between line and block Edit tab settings Insert tab setting above cursor Delete tab setting above cursor Toggle status line Set default tab settings
9610a
Page 437
FST 200
C.3
Appendix C
Error messages Errors are not completely preventable - to err is human - in the operation of the FST software, in particular when it is being used with different FPCs. To help you in using the FST software, in the event of an error a message will appear, generally against a red background (in the message line or in a window). These error messages are intended to provide an indication of the possible cause of an error. The FST software error messages for all controller types are listed below, in alphabetical order and with a brief explanation.
C.3.1 FST software messages A Absolute operand already exists. You are attempting to assign to a symbolic operand an absolute operand that has already been defined elsewhere.
Absolute operand is invalid The operand you are attempting to enter must not contain any impermissible characters.
Allocation listing is full. No further input possible. Insufficient RAM memory capacity available for further editing.
A maximum of 20 tab stops are permitted You are attempting to insert a further tab setting, although you have already reached the maximum number of 20.
Argument value #6 invalid Valid argument values are ’D’ for Download and ’U’ for Upload.
9610a
C-7
Page 438
FST 200
Appendix C
Associated goto instruction is missing / invalid The conditional part of a rung includes an identifier for a goto target which has not been specified as a goto target in any goto instruction.
Associated goto target is missing / invalid The goto instruction contains a goto target which does not occur as a goto label in any rung.
B Block operation not possible The block has not been marked (has the end of the block been defined?) or the marked block is not visible. Or you are attempting to carry out a block operation within a marked block.
Block operation will be cancelled. Additional information under [F9] An error has occurred during a copy, move, delete or read block operation.
C Cannot address output device A printing routine has determined that either the printer is not ready, or it is not possible to create a file. The disk may be full.
Cannot create directory, as file exists. The FST software install routine has determined that the FST directory specified exists as a file. Rename the file if necessary.
Cannot create directory C:\FESTO. There is probably a problem with your hard disk.
Cannot create directory C:\FESTO, as FESTO exists on C:\ as a file. The FST software install routine has determined that FESTO exists as a file on C:\. Rename the file if necessary.
C-8
9610a
Page 439
FST 200
Appendix C
Cannot create directories. There is probably a problem with your hard disk.
Cannot edit corrupt LDR file. The disk or the file is corrupted.
Cannot open file A file with the extension ’LOG’, ’FST’ or ’OBJ’ cannot be opened, because it is corrupted or missing.
Cannot open library The library needed for compiled programs cannot be opened.
Cannot open object file The loader program cannot find file *.OBJ.
Cannot save the file in full Modifications to the function key assignment cannot be saved, because there is no more space available on the floppy disk/hard disk.
Check sum test failed A checksum error was found when downloading an Intellec-Hex record from a controller.
Column is not yet empty. Programming in the ladder diagram: You are attempting to delete a column although you have not yet removed the contacts or boxes located in this column.
Comparator is already in the parentheses Statement list programming error: Only one comparison is permitted in a parenthesis level.
Conditional part has no contact Programming in the ladder diagram: The rung has not been assigned to a condition symbol.
9610a
C-9
Page 440
FST 200
Appendix C
Controller type unknown, not supported or faulty transmission Either you have connected an incorrect controller type, or errors have occurred in transmission.
Copy COMMAND.COM to B:\ The FST software install routine has determined that the COMMAND.COM file is not located in the FST directory.
Corrupt ladder diagram file The ladder diagram file was found to be corrupted on reading. The translation procedure or editor call is cancelled.
Could not create output file. Either corrupted data or no data were found on writing EPROM information to a file. This may be a drive error, DOS error or disk error.
D Disk/hard disk is full You are attempting to carry out a project backup procedure although there is no longer sufficient capacity available on the floppy disk/hard disk.
Display file is empty This error message is displayed in all functions (except for Edit) if the file specified when the function is selected is empty. Fill the file or select an existing file.
Display RAM Load not possible in this display You have selected the RAM load function, but the current display type of the file selected does not permit RAM mode.
DOS error. File is write-protected or invalid filename A block read or save operation has determined that the relevant file is write-protected or that a filename with invalid characters has been entered.
C-10
9610a